Trycom Technology TRP-C34H User Manual

TRP-C34H
Ethernet to 4 RS232/422/485 Converter
User’s Manual
Trycom Technology Co., Ltd
1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC
T el: 886-2-86781191, Fax: 886-2-86781172
Web: www.trycom.com.tw
Copyright
Copyright Notice: The information in this manual is subject to change without prior notice in order to improve reliability , design and function and dosed not represent a commitment on the part of the manufacturer. No part of this manual may be reproduced, copied, or transmitted in any form without the prior written permission of manufacturer. Acknowledgment Products mentioned in this manual are mentioned for identification purpose only. Products manes appearing in this manual may or may not be registered trademarks or copyright of their respective companies.
2
1. Introduction
TRP-C34H 4 RS232/422/485 Serial Server provides a transparent way of connecting Serial
devices over Ethernet. It can transmit data between the Serial and Ethernet interfaces bi-directionally. To establish automatic or remote data acquisition, TRP-C34H solution can easy to connect to 3 TRP-C08X which support 16 Real-COM/ TCP Port by USB cable with only one IP address.
By specifying the IP address and the TCP Port number, a host computer can access different Serial Devices such as Serial Modems, Serial Thermometers, Magnetic Card Readers, Barcode Scanners, Data Acquisition Systems, POS Terminals, Industrial PCs etc., over the Network, you can centralize Serial Device management and distribute the management to different hosts at the same time. TRP-C34H makes possible to access distant Serial Devices over Network as if they were directly connected to the Standard COM Port of a Personal Computer.
TRP-C34H supports different modes of operation allowing user to operate the system in different environments.
Real COM Mode.
TRP-C34H comes equipped with COM drivers that work with Operating Systems WIN 32bit XP /Vista/2003Server/2008 Server (32-bit & 64-bit), 2000 Server OS, Win 7 (32-bit & 64-bit), The driver establishes a transparent connection between host and serial device by mapping the IP: Port Number of the TRP-C34H’s Serial Port to a local COM Port on the host computer.
The important point is that Real COM Mode allows users to continue using RS-232/422/485 serial communications software like HyperTerminal and similar applications.
TCP Server Mode.
In TCP Server mode, TRP-C34H provides a unique IP: Port address on a TCP/IP network. TRP-C34H waits passively to be contacted by the host computer, allowing the host computer to establish a connection with and get data from the serial device. This operating mode supports up to 4 simultaneous connections, so that multiple hosts can collect data from the same serial device—at the same time.
TCP Client Mode.
In TCP Client mode, TRP-C34H can actively establish a TCP connection to a pre-defined host computer when serial data arrives. After the data has been transferred, TRP-C34H can automatically disconnect from the host computer by using the TCP alive check time or Inactivity time settings. This Operating Mode supports establishing the TCP connection up to 4 Destination Hosts.
3
UDP Mode.
Compared to TCP communication, UDP is faster and more efficient. In UDP mode, you can multicast data from the serial device to multiple host computers, and the serial device can also receive data from multiple host computers, making this mode ideal for message display applications.
TRP-C34H hardware support wide range power input , the 4 RS422/485 interface with surge, over current ,over voltage protection, the RS485 interface built-in hardware decoder ensure RS485 data without lost, Specify hardware can ensure on line RS485 device working fine.
The TRP-C34H has four synchronous D SUB 9 pin serial port for RS232 connection and 4 screw terminal block for RS422/485 and power connection. The Ethernet port support Auto-MDIX and Auto-select 10/100MB.
When TRP-C34H working at unstable voltage industrial environment, the hardware circuit detection can prevent the power fail cause of the boot fail and Re-Boot.
1-1. Features
z Wide input range DC power supply. z Supports Socket operation modes like TCP Server, TCP Client, and UDP using TCP/IP and
UDP protocols.
z Support Auto-MDIX twisted pair crossover detection and auto-correction. z Low cost solution and easy to support 6/8/10/12/14/16 RS-232/422/485 Serial Ports. z Each Port maximum connection 4 host PC at TCP Server and TCP Client Mode. z External P1/P2/P3 USB port, each port can connect TRP-C08S/C08U/C08H/C08X/C29U. z Maximum allowed bandwidth is 460 Kbps per Serial Port. z Supports Web Console, Telnet Console. z Runs in Stand Alone Mode. z Built in Restore Factory default push button. z Features Accessible Imps List to add or remove “legal” remote host IP Addresses to prevent
unauthorized access to TRP-C34H.
z Features Auto IP Address Report to periodically report the IP Address of TRP-C34H to the
assigned Host on Network.
z Auto direction RS485 flow control by hardware. z Surge protection and over current and over voltage on RS-422/485 data lines. z Virtual COM drivers for WIN 32bit XP /Vista/2003Server/2008 Server (32-bit & 64-bit), 2000
Server OS, Win 7 (32-bit & 64-bit).
z Fully compatible with Ethernet and TCP/IP protocol. z Supports 10/100 Mbps Ethernet. z Power/Link and 4 pair Serial RX/TX mode LED indicator. z Support screw terminal and standard external DC power adaptor.
4
z Din rail or panel mounts support.
1-2 . Specification.
z CPU:32 bit 170MHZ with MMU. z SDRAM:32MB. z FLASH:8MB. z Power Input Voltage: DC +10V to +30V. z LAN: Auto-MDIX, 10/100 Mbps Auto-detecting. z RS-232: RI,TX, RX, RTS, CTS, DTR, DSR, DCD, GND. z RS-422: TX+, TX-, RX+, RX-. z RS-485: Data +, Data –. z Data Rate: 75~921Kbps. z Parity: none, even, odd. z Data Bits: 5, 6, 7 or 8. z Stop Bits: 1, 1.5 or 2. z Configuration through Windows Admin Utility / Web Console / Telnet Console. z Supports Real COM mode using RFC 2217 protocol. z Protocol: ICMP, TCP/IP, UDP, DHCP, Boot, Telnet, DNS, SNMP, HTTP, SMTP, SNTP. z External P1/P2/P3 Port, each port can be connecting item below.
TRP-C08S :USB to 1 RS232 and 1 RS422/485 Isolated Converter.
TRP-C08H :USB to 2 RS232 and 2 RS422/485 Isolated Converter.
TRP-C08U :USB to 4 RS232 Isolated Converter.
TRP-C08X
:USB to 4 RS232/422/485 Converter.
TRP-C29U
:USB to 8 Digital Input and 8 Digital Output Remote I/O.
z Power supply: Screw terminal, or standard external DC adapter. z External P1, P2, P3 connector: USB A Type, support power consumption: 500mA/5V. z Serial interface: +/-15 KV ESD. z RS422/485 interface: Surge, over current, over voltage protection. z Power consumption: 12V/450 mA (without external device). z Operating Temperature: 0 to 65 °C. z Humidity: 0~90% Non-Condensing. z Dimensions: 145(L)*118(W)*26(H) /mm. z Weight: 728g (W/Packing).
5
1-3. TRP-C34H Support 3 TRP-C08X Diagram.
TRP-C34H is a system level solution with four RS232/422/485 serial ports connected to three TR-C08X to support 16 serial port interfaces,TRP-C08X connected to any of the P1/P2/P3 Ports of TRP-C34H to support 8/12/16 Serial Port interfaces. Each TRP-C08X can provide four RS232/RS422/RS485 Serial Ports.
1-4. TRP-C34H Support TRP-C08X/C08S/C08H/C08U/C29U Diagram.
TRP-C08X/TRP-C08H/TRP-C08U/TR-C29U connected to any of the P1/P2/P3 USB Ports of TRP-C34H to support 6/8/10/12/14/16 Serial Port interfaces or Maximum 24 Channel I/O with TRP-C29U.
6
2. Hardware Description.
2-1. Panel layout and Dimension.
mm/Unit.
Notice: User can only choose either external DC-Jack or Screw terminal DC input. Do not use
DC-Jack and screw terminal DC input simultaneously.
7
2-2. LED indicators. PWR LED: Blinking: Not Ready. ON: Stand By. LINK LED: Ethernet cable connection and data active. TX/RX LED: COMA~COMD RS232/422/485 Transiting/Receiving Indicator. DC Jack: Power Input DC +10V to +30V. (Pleas use the 5.5*2.1mm DC JACK).
2-3. Factory default.
*Push the factory restore button till the PWR LED off and then reboot.
Hardware Setting: COMA~COMD: RS232. Unlock Password: trycom. Model Name: SerialServer 4S. Basic configuration:
IP setting:
8
Port Setting: Port 1~4:115200bps,8-bit,None,RS232 Operating Mode: Real Com Mode. Accessible IPs: None Setting. Auto Warning: None Setting. IP Address Report: None Setting. Password: Factory: trycom
2-4. DIP Switches. There are 4 DIP switch allows the TRP-C34H adjust to RS232 or RS422/485 Inside of the box.
9
*Please use screwdriver and then open back of metal, adjust the switch to select RS232 or RS422/485.
2-5. Push Button.
If lost the password or IP, user can keep push button for restore factory default till the PWR LED off and then reboot.
2-6. Four RS232 D-SUB male PIN assignments.
2-7. Four RS422/485 Screw Terminal assignments.
10
3. Installing TRP-C34H Hardware.
STEP1: Please use screwdriver and then open back of metal, adjust the switch to select
RS232 or RS422/485 function.
STEP2: Connect the power source from DC-Jack or screw terminal, the PWR LED will
blinking, wait till boots PWR LED ON.
STEP3: Connect TRP-C34H with Ethernet port by RJ45 cable.
If the cable is properly connected the “LINK” LED will light up. *The TRP-C34H Support Auto-MDIX, A straight-through or crossover RJ45 cable can be used to make a connection directly to the HUB/Router/PC LAN port.
STEP4: Connect TRP-C34H to RS232 device by Null-Modem cable.
Connect TRP-C34H to RS422/485 by AWG #12~30 twisted pair wires.
3-1. RS485 Wiring.
The RS-485 mode supports the Transmit and Receive channels use twisted pair wire half-duplex operation.
3-2. RS422 Wiring.
The RS-422 mode supports 4 channels with full duplex operation use dual twisted pair wire half-duplex operation.
.
3-3. RS232 Wiring.
Refer to the Pin out table for connections.
11
4. How to configure TRP-C34H.
There are 3 ways to access the TRP-C34H. a. Serial Server Admin Utility.
b. WEB Server.
12
c. Telnet.
4-1. Installing Serial Server Admin Utility.
The “Serial Server Admin Utility” Support WIN XP/VISTA/2003 Server/2008 Server 32/64 bit, 2000 Server/Win 7.
13
Insert the TRP-Serial CD, find the ”Serial Server Admin Utility”.
When Installation is completed the wizard creates a Serial Server Admin Utility shortcut on the Desktop as shown below.
Double Click on the Serial Server Admin Utility then Right click on the main window or go to Server Manager in Menu Bar and select Search Devices to find the TRP-C34H on the network.
By default all the devices searched are locked and can be seen under the status column of the Server Manager Window in order to protect from unauthorized configuration changes.
In order to configure the device, it has to be Unlocked first. Unlock password: trycom
After the device has been Unlocked, the device can be configured for all Network, Serial, Operating settings. Select the device to be configured, Right Click on the selected device and click on configure to go to Configuration menu. (Double clicking on selected device can also open the Configuration menu).
Loading...