4-20mA Loop Powered Adapters for DPM 951 and DPM 952
DMLP 952-ADP for DPM 952-R
DMDV-952-ADP
DMLP 951-ADP for DPM 951-R
1 2 3 4 1 2 3 4
1- Span/ Gain adjustment
2- Zero/ offset adjustment
3- Input Connections
1 2 3
Characteristics
Accuracy (± 1 digit)
Linearity
Span adjustment range 150 1999
Sample Rate 3 Per sec
Temperature Stability 300 ppm/°C
Operating Temperature 0 50 °C
Loop Volt Drop 4.2 4.7 5.2 V
1 = Earth Connection
2 = 4 to 20mA – input
3 = 4 to 20mA + input
Min Typ Max Unit
0.5 1 %
0.5
4- Decimal Point selection DIP switches (SW 1 -3)
and Span range configuration (Sw4)
(– = Switch DOWN (off ) • = Switch UP (on ))
Display Switches …… 1 2 3 4
1999 = ▼ ▼ ▼ -
199.9 = ▲ ▼ ▼ -
19.99 = ▼ ▲ ▼ -
1.999 = ▼ ▼ ▲ -
-------------------------------------------------------------------
Max Span range 150 to 1000
Max Span range 1000 to 1999
±1
- - - ▲
- - - ▼
Instructions for fitting 4 to 20mA loop powered adapter to DPM951 or DPM 952
Configure DPM 951 or DMP 952 module for supply voltage, and annunciators. Configure
annunciators as required (mA, A, mv, V etc) refer to DPM 951/ 952 instructions. Configure SW4 for
the maximum span range required (150 to 1000, or 1000 to 1999), also set SW 1 to 3 for the decimal
place configuration required. Configure the module for a 5V supply – solder Lin k 6 on the rea r of the
PCB, leave links 1 to 5 unsoldered.

Annunciator
uration
Confi
6 5 3 2 1
4
Annunciator
Confi
uration
4
6
5
(Rear of DPM 952) (Rear of DPM 951)
1) Fit the adapter board onto the rear of the DPM 951 or DPM 952 module (depending on
adaptor model).
(View from rear of unit)
2) Connect the complete module to your 4 to 20mA signal wires, also connect an Earth/
Ground connection to the appropriate terminal.
3) Input your minimum signal (or 4mA), Calibrate the unit to indicate zero or your required
value (using the Zero/ offset adjustment potentiometer). Input your maximum signal (or
20mA) calibrate the span of the unit at your maximum signal, adjusting the span until the
unit displays your required value at the maximum signal level (using the Span/ Gain
adjustment potentiometer). Test the unit with your actual 4 to 20mA signal, re-adjust if
necessary.
Trumeter Company Ltd, Milltown Street, Radcliffe, Manchester
Tel: (44) (0)161 724 6311 Fax: (44) (0)161 724 9455
Trumeter Ireland, PO Box 5050, Drogheda, Ireland
Tel: (353) (0)41 983 7755 Fax: (353) (0)41 983 7753
Trumeter Company Inc.,1020 North West 6 St reet, Deerfield Beach
Tel: (1) 954 725 6699 Fax: (1) 954 725 5599
Trumeter Canada, 190 Brittania Road East , Unit 5, Mississauga,
Tel (1) 905 890 0622 Fax: (1) 905 890 7994
Trumeter Deutschland, Postfach 1215, D-71141, Steinenbronn, Deutschland
Trumeter, 99 rue Parmentier, BP 304, 59666 Villeneuve d'Ascq Cedex, France
Tel: (49) (0) 7157 20801 Fax: (49) (0) 7157 20813
Tel: (33) (0) 3 20 59 16 26 Fax: (33) (0) 3 20 59 16 27
M26 1NX, England