True Systems pT2-500D Operation Manual

pT2-500D
PRECISION DYNAMIC MICROPHONE PREAMPLIFIER with Direct Input and Low-Frequency Adjust Control
500 series compatible module
OPERATION MANUAL
Version 1.0
pT2-500D Microphone Preamplifier OPERATION MANUAL
Version 1.0
2
©2011 TRUE SYSTEMS
CERTIFICATION
Declaration of Conformity
Sunrise Engineering and Design Inc. hereby declares the True Systems pT2-500D single channel microphone preamplifier module to be in material conformity with the following EC directives and related standards:
2006/95/EC Low Voltage Directive
2004/108/EC EMC Directive
EN60065: 1998 Safety requirements for audio equipment
EN55103-1: 1997 Electromagnetic compatibility of audio equipment: Emission
EN55103-2: 1997 Electromagnetic compatibility of audio equipment: Immunity
Technical files are maintained at corporate headquarters of Sunrise Engineering and Design Inc., 1630 S. Research Loop, Suite 150, Tucson, Arizona 85710, U.S.A
RoHS
Certificate of Compliance
This is to certify that the True Systems pT2-500D is RoHS compliant and meet the requirements and specified limits of restricted substances according 2002/95/EC directive.
WEEE
pT2-500D is marked with the WEEE symbol to comply with the European Union’s Waste Electrical & Electronic Equipment (WEEE) Directive 2002/96/EC. The symbol indicates that this product should not be treated as household waste. It must be disposed and recycled separately as electronic waste. Please assist to keep our environment clean.
Above declarations are void by modification of the device without approval, or unau­thorized servicing.
Tucson, 09-01-2011
Tim Spencer, president
pT2-500D Microphone Preamplifier OPERATION MANUAL
Version 1.0
3
©2011 TRUE SYSTEMS
Important symbols:
This symbol appearing on the product or in this manual indicates the
presence of dangerous voltage within the product enclosure that presents the risk of electric shock injury. When this symbol appears next to an operation discussed in this manual, only qualified technical personnel should perform that operation.
This symbol indicates important operating or maintenance instructions that
should be read carefully. Failure to observe these instructions could result in damage to this product or other equipment.
WARNINGS:
While no hazardous voltage is present within this product during normal operation, please observe the following warnings regarding any AC-powered equipment into which this product is installed:
To reduce the risk of electric shock injury, do not remove the access covers on AC-powered equipment. Refer servicing to qualified personnel.
This unit is intended for indoor operation only
Do not operate this unit in the presence of rain, liquids or condensing
moisture.
Do not expose the unit to dripping or splashing liquids.
Do not place liquid-filled objects on the unit.
Do not defeat the earth ground connection in the AC power cable.
Do not defeat intended AC power connection polarization.
Do not use a damaged or excessively worn cord to connect the equipment
to AC power.
CAUTIONS:
Severe damage to pT2-500D will occur if incorrect power supply
voltages are applied to the card edge connector. Please consult the “CONNECTIONS” section in this manual for proper power supply specifications/connections.
Disclaimer: Product failure caused by improper voltage application cannot be covered under warranty.
Liquid entering the product enclosure is likely to cause performance
degradation or failure. Failures due to moisture entering the enclosure cannot be covered under warranty. Should liquid spill on the unit, immediately disconnect it from the AC power source and contact TRUE Systems for servicing instructions
This product is designed to operate in an ambient temperature range of
10°C to 50°C (50°F to 122°F).
pT2-500D Microphone Preamplifier OPERATION MANUAL
Version 1.0
4
©2011 TRUE SYSTEMS
CERTIFICATIONS…………………………………………………………...
CE RoHS WEEE
2
SAFETY and OPERATING PRECAUTIONS…………………………….
3
TABLE of CONTENTS……………………………………………………...
4
PRODUCT OVERVIEW……………………………………………………..
New Type 2 Circuit Design Features
5
INSTALLATION……………………………………………………………...
Unpacking Card Rack Installation
Card Edge Connections
Ventilation
6
OPERATION………………………………………………………………….
Connections
Output Microphone Input Instrument Input and Thru (DI)…………………………………………………..
A Word About Cables…………………………………………………………………… Cable Types
Instrument cables Microphone and Line Level cables
Front Panel Layout………………………………………………………………………. Controls
Gain, LO/HI Low Frequency Adjust Phantom Power
Instrument Input Level Indicators
7
8 9
10
SPECIFICATIONS…………………………………………………………...
11
TROUBLESHOOTING………………………………………………………
12 13
WARRANTY & SERVICE INFORMATION……………………………..
Registration and Warranty Service and Support……………………………………………………………………..
14
15
pT2-500D Microphone Preamplifier OPERATION MANUAL
Version 1.0
5
©2011 TRUE SYSTEMS
Thanks for using our product! We appreciate the confidence you place in TRUE Systems by purchasing the
pT2-500D
microphone preamplifier/instrument DI. We design our products to deliver stunning musical accuracy, uniquely useful features, exceptional value, and reliability. Every aspect of this product design was determined by careful listening tests and extensive user feedback. Please feel free to contact us with questions or comments.
The
pT2-500D
utilizes our Type 2 design to achieve ultra-resolution musicality and provide optimum performance with dynamic mics, ribbon mics, and self-powered tube mics. We’ve eliminated the components required for phantom power in order to provide higher input impedance and reduced distortion and noise. More preamp gain is typically required by dynamic and ribbon microphones, so we’ve provided up to 76dB – in two ranges selected for easy control.
Lo-F Adjust (low frequency adjustment control):
The Lo-F Adjust selector allows nuanced attenuation of low-end signal content. The five
frequency selections are reciprocal to proximity effect characteristics of various commonly-used microphone types, and can be particularly effective in removing low frequency “mud“ from vocals and bass instruments.
FEATURES
API™ 500 series module format Totally Balanced Topology for:
insensitivity to ground noise/loops
Insensitivity to EMI, both external and from adjacent modules/power supplies
reduced distortion
Rail-to-Rail design for:
higher internal headroom
higher maximum input level without pad (up to +21dBu)
higher output level without transformer and excessive power supply current
0.1% precision resistors for:
exceptional Common-Mode and Output Signal Balance performance
excellent unit-to-unit sonic consistency
“Real DI” IN and THRU jacks for:
Easy hookup to amps for simultaneous DI and amp’d tracking or live sound
Easy hookup to other DI’s or effects for simultaneous tracking or live sound
Detented, continuous Gain Control and Dual Gain Ranges for:
easy gain resetability
easy gain setting over wide gain ranges
Steel Enclosure for:
protection from EMI and RFI
protection from ESD and handling contamination/damage
Lo-F Adjust control 4-Level Signal Meter
Loading...