True Residential TR36FRZRSSA Installation manual

TRUE RESIDENTIAL
®
TR-30 / TR-36
INSTALLATION / USER GUIDE
PRESERVE THE MOMENT
®
THANK YOU
FOR YOUR PURCHASE
June 6, 2019
IN D E X
O W N E RS HI P, SAFETY PRECAUTIONS, DISPOSAL OF OLD REFRIGERATOR, CFC DISPOSAL
1-2
SITE PREPARATION, ELECTRICAL REQUIREMENTS
3-6
PLAN VIEWS
7-13
ANTI-TIP BRACKET INSTALLATION, LEVELING THE UNIT
14 -17
BASIC ELECTRONIC CONTROL OPERATIONS REFRIGERATOR AND FREEZER
18-25
BASIC ELECTRONIC CONTROL OPERATIONS DUAL ZONE
26-33
SHELVING, REFRIGERATOR STORAGE, FREEZER STORAGE, REMOVING THE DOORS,
KICK PLATE INSTALLATION
34-36
STAINLESS STEEL EQUIPMENT CARE & CLEANING, GENERAL MAINTENANCE, CONDENSATION,
DATA TAG, WARRANTY STATEMENT, CONTACT US
37- 4 0
NOTE:
AS WE STRIVE FOR CONTINUOUS IMPROVEMENTS, FEATURES AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
June 6, 2019
I of 40
30 & 36 INCH REFRIGERATOR, FREEZER & DUAL ZONE COLUMN
30” REFRIGERATOR
COLUMN
STAINLESS SOLID DOOR
30” REFRIGERATOR
COLUMN
STAINLESS GLASS DOOR
30” FREEZER
COLUMN
STAINLESS SOLID DOOR
30” DUAL ZONE
WINE COLUMN
STAINLESS GLASS DOOR
36” REFRIGERATOR
COLUMN
STAINLESS SOLID DOOR
36” REFRIGERATOR
COLUMN
STAINLESS GLASS DOOR
36” FREEZER
COLUMN
STAINLESS SOLID DOOR
Commercial refrigeration refined for the home, envied in the industry,
and crafted—gorgeously—in America.
II of 40
June 6, 2019
O w n e r s h i p
1 - 2
s a f e t y p r e c a u t i O n s
D i s p O s a l O f t h e O l D r e f r i g e r a t O r
c f c D i s p O s a l
PRESERVE THE MOMENT
June 6, 2019 Page 1 of 44
®
OWNERSHIP
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
TO INSURE THAT YOUR UNIT WORKS PROPERLY FROM THE FIRST DAY, IT MUST BE INSTALLED PROPERLY.
NOTE: WE HIGHLY RECOMMEND A TRAINED REFRIGERATION MECHANIC AND ELECTRICIAN INSTALL YOUR TRUE RESIDENTIAL® CA BI NE T. THE COST OF A PROFESSIONAL INSTALLATION IS MONEY WELL SPENT.
• Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
• Keep hands away from the “pinch point” areas
(gaps between the doors and between the doors
and cabinet). Small areas are not necessarily safe.
• Unplug the refrigerator before cleaning and
making repairs.
• Setting temperature control to OFF only removes
power from the refrigeration system, it does not
remove power from other circuits. For example,
temperature control and lights.
NOTE: WE STRONGLY RECOMMEND THAT ANY
SERVICING BE PERFORMED BY A QUALIFIED
INDIVIDUAL.
Before you start to install your True Residential®
Cabinet, carefully inspect it for freight damage. If
damage is discovered, immediately file a claim with
the delivery freight carrier. True is not responsible
for damage incurred during shipment. This appliance
is intended to be used in household and similar
applications such as:
• staff kitchen areas in shops, offices and other
working environments;
• bed and breakfast type environments;
• catering and similar non-retail applications.
Any questions about the installation please
contact your True dealer or True Technical Service
Department at 844-746-9423. Please have your
model and serial numbers available when you call our
Service Department.
SAFETY PRECAUTIONS
• This refrigerator must be properly installed
and located in accordance with the installation
instructions before it is used.
• Do not allow children to climb, stand or hang on
the shelves in the refrigerator. They could seriously
injure themselves or damage the refrigerator.
PROPER DISPOSAL OF THE OLD REFRIGERATOR
DANGER: Risk of child entrapment. Before you throw
away your old refrigerator or
freezer:
• Take off the doors
• Leave the shelves in place
so that children may not
easily climb inside
DANGER: Risque de
piégeage de l´enfant.
Avant de jeter votre vieux
réfrigérateur ou congélateur:
• Enlevez les portes.
• Laissez les étagéres en place de sorte que les
enfants ne puissent pas facilement monter à
l´intérieur.
CFC DISPOSAL
Your old refrigerator may have a cooling system that
used CFCs (chlorofluorocarbons). CFCs are believed
to harm stratospheric ozone. If you are throwing away
your old refrigerator, make sure the CFC refrigerant
is removed for proper disposal by a qualified service.
If you intentionally release this CFC refrigerant you
can be subject to fines and imprisonment under
provisions of the environment legislation.
TRUE RESIDENTIAL
®
June 6, 2019 Page 2 of 44
3 - 5
s i t e p r e p a r a t i O n
e l e c t r i c a l r e q u i r e m e n t s
PRESERVE THE MOMENT
June 6, 2019 Page 3 of 44
®
SITE PREPARATION
25 25/32"
655mm
FLUSH INSTALL
TR-30REF-R-SG-A
R
TR-30REF-R-SG-A
Rough Opening dimensions. (See figure 1)
For FLUSH installations the front face of the unit will be flush with the surrounding cabinets. (See figure 2)
For PROUD (Standard) installations, the front face of the unit will extend beyond cabinets. (See figure 3)
NOTE: IT IS NOT RECOMMENDED TO INSTALL UNITS SIDE BY SIDE WITH HINGES TOUCHING EACH OTHER. IF YOU PLAN TO INSTALL UNITS HINGE TO HINGE, CALL TECH SUPPORT AT 844-746-9423 FOR INSTALLATION INSTRUCTIONS.
TR-3 0 TR-3 6
FLUSH OPENING DIMENSIONS PROUD OPENING DIMENSIONS
Width Depth Height
30 ¼" 25
* BECAUSE OF THE WEIGHT OF THIS UNIT, IT IS RECOMMENDED TO CONSULT A FLOORING EXPERT PRIOR TO INSTALLATION. THE
FLOORING BENEATH THE UNIT SHOULD BE R ATED TO SUPPORT AT LEAST 150 POUNDS PER SQUARE FOOT.
⁄" 84 ¼"
Width Depth Height
29 ¾" 23
⁄" 84"
TR-30 – FRONT VIEW
FIGURE 1 - ROUGH OPENING
FLUSH OPENING DIMENSIONS PROUD OPENING DIMENSIONS
Width Depth Height
36 ¼" 25
⁄" 84 ¼"
Width Depth Height
35 ¾" 23
⁄" 84"
TR-30 – TOP VIEW
FIGURE 2 - FLUSH INSTALL
& ELECTRICAL AREA
Electrical located
in this area.
8"
(204 mm)
2"
(51 mm)
841/4"
(2140 mm)
FLUSH
INSTALL
25 25/32"
655mm
FLUSH INSTALL
(2134 mm)
77"
(1956 mm)
293/4"
(756 mm)
301/4"
(769 mm)
PROUD
INSTALL
FLUSH
INSTALL
TRUE RESIDENTIAL
®
84"
PROUD
INSTALL
FIGURE 3 - PROUD INSTALL
23 25/32"
604mm
PROUD INSTALL
NOTE: DIMENSIONS MAY VARY BY ± 1/8”
June 6, 2019 Page 4 of 44
TR-30 – TOP VIEW
TR-30 – TOP VIEW
29 9/16"
135°
20 11/16"
525mm
90°
55 1/4"
1403mm
23 25/32"
604mm
29 15/32"
748mm
31 15/32"
799mm
29 9/16"
751mm
135°
20 11/16"
525mm
TR-30DZW-R-SG-A
25 25/32"
655mm
27 29/32"
709mm
30 15/32"
774mm
2 9/16"
65mm
3 15/16"
100mm
135°
20 19/32"
523mm
23 25/32"
604mm
55 1/4"
1403mm
29 15/32"
748mm
31 15/32"
799mm
90°
29 9/16" 751mm
TR-30REF-R-SS-A
R
36"
3 15/16"
100mm
27 29/32"
709mm
25 25/32"
655mm
30 15/32"
774mm
2 9/16"
65mm
90°
23 25/32"
604mm
35 9/16"
903mm
61 1/4"
1556mm
37 15/32"
952mm
35 15/32"
901mm
135°
24 13/16"
631mm
TR-36REF-R-SS-A
R
135°
24 13/16"
631mm
TR-36REF-R-SS-A
90°
23 25/32"
604mm
35 9/16"
903mm
61 1/4"
1556mm
37 15/32"
952mm
35 15/32"
901mm
135°
24 13/16"
631mm
TR-36REF-R-SS-A
TR-36 – TOP VIEW
TR-30 – FRONT VIEW
30"
67 29/32"
1725mm
DOOR
HEIGHT
762mm
72 5/8"
1845mm
83 15/16"
NOTE: DIMENSIONS MAY VARY BY ± 1/8”
2132mm
TR-36 – FRONT VIEW
915mm
83 15/16"
2132mm
72 5/8"
1845mm
67 29/32"
1725mm
DOOR HEIGHT
June 6, 2019 Page 5 of 44
135°
20 19/32"
523mm
23 25/32"
604mm
55 1/4"
1403mm
29 15/32"
748mm
31 15/32"
799mm
90°
29 9/16"
751mm
TR-30REF-R-SS-A
2 9/16"
90°
23 25/32"
604mm
35 9/16"
903mm
61 1/4"
1556mm
37 15/32"
952mm
35 15/32"
901mm
135°
24 13/16"
631mm
TR-36REF-R-SS-A
65mm
3 15/16"
100mm
TR-30 – SIDE VIEW TR-36 – SIDE VIEW
30 15/32"
774mm
27 29/32"
709mm
25 25/32"
655mm
2 9/16" 65mm
3 15/16"
100mm
30 15/32"
774mm
27 29/32"
709mm
25 25/32"
655mm
ELECTRICAL REQUIREMENTS TR-3 0/T R-36
For all built-in models, the electrical supply should be
located within the shaded area shown in the illustration.
Follow the National Electrical Code and local codes
and ordinances when installing the receptacle. A
dedicated circuit, supplying only this appliance is
required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
person in order to avoid a hazard.
• POWER SUPPLY 115 V AC, 60 HZ
• CIRCUIT BREAKER 15 AMP
• RECEPTACLE 3-PRONG GROUNDING-TYPE
NOTES:
• THE OUTLET MUST BE CHECKED BY A QUALI­FIED ELECTRICIAN TO BE SURE THAT IT IS WIRED WITH THE CORRECT POLARITY.
• VERIFY THAT THE OUTLET IS PROPERLY GROUNDED.
TRUE RESIDENTIAL
®
June 6, 2019 Page 6 of 44
TR-30/TR-36 – FRONT VIEW
ROUGH OPENING &
ELECTRICAL AREA
Electrical located
in this area.
8"
(204 mm)
293/4"
(756 mm)
301/4"
(769 mm)
PROUD
INSTALL
FLUSH
INSTALL
2"
(51 mm)
(2134 mm)
PROUD
INSTALL
77"
(1956 mm)
841/4"
(2140 mm)
FLUSH
INSTALL
84"
p l a n V i e w s
t r - 3 0 / t r - 4 2
t r - 3 0 / t r - 4 8
7 - 11
t r - 3 0 / t r - 3 0
t r - 3 0 / t r - 3 0 / t r - 3 0
t r - 3 6 / t r - 3 6
t r - 3 6 / t r - 3 0
PRESERVE THE MOMENT
June 6, 2019 Page 7 of 44
®
TR-30 / TR-42
TR-42,30DZW
R
23 25/32"
604mm
PROUD INSTALL
TR-42,30DZW
R
TR-42,30DZW
30 15/32"
TR-42,30DZW
R
FLUSH OPENING DIMENSIONS PROUD OPENING DIMENSIONS
Width Depth Height
72¼" 25
⁄" 84 ¼"
Width Depth Height
71¾" 23
⁄" 84"
NOTE: DIMENSIONS MAY VARY BY ± 1/
8
"
FLUSH VS. PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
23 25/32"
604mm
PROUD INSTALL
PLAN VIEW
72 1/32"
1829mm
ROUGH OPENING & ELECTRICAL AREA
30 1/8"
71 3/4" PROUD INSTALL
72 1/4" FLUSH INSTALL
77"
7" TYP
2"
PROUD
INSTALL
84 1/4"
84"
FLUSH
INSTALL
774mm
2 9/16"
27 29/32"
65mm
709mm
25 25/32"
655mm
83 15/16"
2132mm
TRUE RESIDENTIAL
3 15/16" 100mm
®
June 6, 2019 Page 8 of 44
TR-30 / TR-48
TR-48,30DZW
R
23 25/32"
604mm
PROUD INSTALL
TR-48,30DZW
R
TR-48,30DZW
TR-48,30DZW
R
FLUSH OPENING DIMENSIONS PROUD OPENING DIMENSIONS
Width Depth Height
78¼" 25
⁄" 84 ¼"
Width Depth Height
77¾" 23
⁄" 84"
NOTE: DIMENSIONS MAY VARY BY ± 1/
8
"
FLUSH VS. PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
23 25/32"
604mm
PROUD INSTALL
PLAN VIEW
78 1/32" 1982mm
ROUGH OPENING & ELECTRICAL AREA
77 3/4" PROUD INSTALL
78 1/4" FLUSH INSTALL
30 1/8"
77"
7" TYP
2"
PROUD INSTALL
84 1/4"
84"
FLUSH
INSTALL
30 15/32"
2 9/16"
65mm
774mm
27 29/32"
709mm
25 25/32"
655mm
83 15/16"
2132mm
3 15/16"
100mm
June 6, 2019 Page 9 of 44
TR-3 0 / T R-30
TR-30REF,30DZW
R
23 25/32"
604mm
PROUD INSTALL
TR-30REF,30DZW
R
TR-30REF,30DZW
30 15/32"
TR-30REF,30DZW
R
FLUSH OPENING DIMENSIONS PROUD OPENING DIMENSIONS
Width Depth Height
60¼" 25
⁄" 84 ¼"
Width Depth Height
59¾" 23
⁄" 84"
NOTE: DIMENSIONS MAY VARY BY ± 1/
8
"
FLUSH VS. PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
23 25/32"
604mm
PROUD INSTALL
PLAN VIEW
60 1/32"
1525mm
ROUGH OPENING & ELECTRICAL AREA
30 1/8"
59 3/4" PROUD INSTALL
60 1/4" FLUSH INSTALL
77"
7" TYP
2"
PROUD INSTALL
84 1/4"
84"
FLUSH
INSTALL
774mm
2 9/16"
65mm
27 29/32"
709mm
25 25/32"
655mm
83 15/16"
2132mm
TRUE RESIDENTIAL
®
June 6, 2019 Page 10 of 44
3 15/16"
100mm
TR-30 / TR-30 / TR-30
TR-30REF,30FRZ,30DZW
R
23 25/32"
604mm
PROUD INSTALL
TR-30REF,30FRZ,30DZW
R
TR-30REF,30DZW
R
TR-30REF,30FRZ,30DZW
R
FLUSH OPENING DIMENSIONS PROUD OPENING DIMENSIONS
Width Depth Height
90¼" 25
⁄" 84 ¼"
Width Depth Height
89 ¾" 23
⁄" 84"
FLUSH VS. PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
23 25/32"
604mm
PROUD INSTALL
PLAN VIEW
90 1/32" 2287mm
ROUGH OPENING & ELECTRICAL AREA
30 1/8" 30 1/8"
89 3/4" PROUD INSTALL
90 1/4" FLUSH INSTALL
7" TYP
2"
77"
84" PROUD INSTALL
84 1/4"
FLUSH
INSTALL
30 15/32"
2 9/16"
65mm
774mm
27 29/32"
709mm
25 25/32"
655mm
83 15/16"
2132mm
June 6, 2019 Page 11 of 44
3 15/16"
100mm
Loading...
+ 33 hidden pages