O W N E RS HI P, SAFETY PRECAUTIONS, DISPOSAL OF OLD REFRIGERATOR, CFC DISPOSAL
3-4
SITE PREPARATION, ELECTRICAL REQUIREMENTS, ANTI-SWEAT FOAM END PANELS
5-8
PLAN VIEWS
9-16
ANTI-TIP BRACKET INSTALLATION, LEVELING THE UNIT, JOINING KIT INSTALLATION
17-2 6
REFRIGERATOR AND FREEZER BASIC ELECTRONIC CONTROL OPERATIONS, SHOWROOM MODE
37-34
DUAL ZONE BASIC ELECTRONIC CONTROL OPERATIONS, SHOWROOM MODE
35-42
SHELVING, REFRIGERATOR STORAGE, FREEZER STORAGE, REMOVING THE DOORS,
KICK PLATE INSTALLATION
43-46
STAINLESS STEEL EQUIPMENT CARE & CLEANING, GENERAL MAINTENANCE, CONDENSATION,
DATA TAG, WARRANTY STATEMENT, CONTACT US
47-50
NOTE:
AS WE STRIVE FOR CONTINUOUS IMPROVEMENTS, FEATURES AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
TEC_TM_009 Rev. B
December 31, 2019 Page 1 of 50
30 & 36 INCH REFRIGERATOR, FREEZER & DUAL ZONE COLUMN
30” REFRIGERATOR
BEVERAGE COLUMN
STAINLESS GLASS DOOR
30” REFRIGERATOR
COLUMN
STAINLESS SOLID DOOR
30” REFRIGERATOR
COLUMN
STAINLESS GLASS DOOR
30” FREEZER
COLUMN
STAINLESS SOLID DOOR
30” DUAL ZONE
WINE COLUMN
STAINLESS GLASS DOOR
36” REFRIGERATOR
COLUMN
STAINLESS SOLID DOOR
36” REFRIGERATOR
COLUMN
STAINLESS GLASS DOOR
36” FREEZER
COLUMN
STAINLESS SOLID DOOR
Commercial refrigeration refined for the home, envied in the industry,
and crafted—gorgeously—in America.
TRUE RESIDENTIAL
®
December 31, 2019 Page 2 of 50
TEC_TM_009 Rev. B
O w n e r s h i p
3 - 4
s a f e t y p r e c a u t i O n s
D i s p O s a l O f t h e O l D r e f r i g e r a t O r
c f c D i s p O s a l
TEC_TM_009 Rev. B
PRESERVE THE MOMENT
December 31, 2019 Page 3 of 50
®
OWNERSHIP
THIS APPLIANCE IS NOT INTENDED FOR USE BY
PERSONS (INCLUDING CHILDREN) WITH REDUCED
PHYSICAL, SENSORY OR MENTAL CAPABILITIES,
OR LACK OF EXPERIENCE AND KNOWLEDGE,
UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR
INSTRUCTION CONCERNING USE OF THE APPLIANCE
BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
TO INSURE THAT YOUR UNIT WORKS PROPERLY
FROM THE FIRST DAY, IT MUST BE INSTALLED
PROPERLY.
NOTE: WE HIGHLY RECOMMEND A TRAINED
REFRIGERATION MECHANIC AND ELECTRICIAN
INSTALL YOUR TRUE RESIDENTIAL® CA BI NE T.
THE COST OF A PROFESSIONAL INSTALLATION IS
MONEY WELL SPENT.
• Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
• Keep hands away from the “pinch point” areas
(gaps between the doors and between the doors
and cabinet). Small areas are not necessarily safe.
• Unplug the refrigerator before cleaning and
making repairs.
• Setting temperature control to OFF only removes
power from the refrigeration system, it does not
remove power from other circuits. For example,
temperature control and lights.
NOTE: WE STRONGLY RECOMMEND THAT ANY
SERVICING BE PERFORMED BY A QUALIFIED
INDIVIDUAL.
Before you start to install your True Residential®
Cabinet, carefully inspect it for freight damage. If
damage is discovered, immediately file a claim with
the delivery freight carrier. True is not responsible
for damage incurred during shipment. This appliance
is intended to be used in household and similar
applications such as:
• Staff kitchen areas in shops, offices and other
working environments;
• Bed and breakfast type environments;
• Catering and similar non-retail applications.
Any questions about the installation please
contact your True dealer or True Technical Service
Department at 844-746-9423. Please have your
model and serial numbers available when you call our
Service Department.
SAFETY PRECAUTIONS
• This refrigerator must be properly installed
and located in accordance with the installation
instructions before it is used.
• Do not allow children to climb, stand or hang on
the shelves in the refrigerator. They could seriously
injure themselves or damage the refrigerator.
PROPER DISPOSAL OF THE OLD
REFRIGERATOR
DANGER: Risk of child entrapment. Before you throw
away your old refrigerator or
freezer:
• Take off the doors
• Leave the shelves in place
so that children may not
easily climb inside
DANGER: Risque de
piégeage de l´enfant.
Avant de jeter votre vieux
réfrigérateur ou congélateur:
• Enlevez les portes.
• Laissez les étagéres en place de sorte que les
enfants ne puissent pas facilement monter à
l´intérieur.
CFC DISPOSAL
Your old refrigerator may have a cooling system that
used CFCs (chlorofluorocarbons). CFCs are believed
to harm stratospheric ozone. If you are throwing away
your old refrigerator, make sure the CFC refrigerant
is removed for proper disposal by a qualified service.
If you intentionally release this CFC refrigerant you
can be subject to fines and imprisonment under
provisions of the environment legislation.
TRUE RESIDENTIAL
®
December 31, 2019 Page 4 of 50
TEC_TM_009 Rev. B
s i t e p r e p a r a t i O n
5 - 8
e l e c t r i c a l r e q u i r e m e n t s
a n t i - s w e a t f O a m e n D p a n e l s
TEC_TM_009 Rev. B
PRESERVE THE MOMENT
December 31, 2019 Page 5 of 50
®
SITE PREPARATION
25 25/32"
655mm
FLUSH INSTALL
TR-30REF-R-SG-A
R
TR-30REF-R-SG-A
• Rough Opening dimensions. (See figure 1)
• For FLUSH installations the front face of the unit will be flush with the surrounding cabinets. (See figure 2)
• For PROUD (Standard) installations, the front face of the unit will extend beyond cabinets. (See figure 3)
NOTE: IT IS NOT RECOMMENDED TO INSTALL UNITS SIDE BY SIDE WITH HINGES TOUCHING EACH
OTHER. IF YOU PLAN TO INSTALL UNITS HINGE TO HINGE, CALL TECH SUPPORT AT 844-746-9423 FOR
INSTALLATION INSTRUCTIONS.
TR-3 0TR-3 6
FLUSH OPENING DIMENSIONSPROUD OPENING DIMENSIONS
WidthDepthHeight
30 ¼"25 ⁄"84 ¼"
* BECAUSE OF THE WEIGHT OF THIS UNIT, IT IS RECOMMENDED TO CONSULT A FLOORING EXPERT PRIOR TO INSTALLATION. THE
FLOORING BENEATH THE UNIT SHOULD BE R ATED TO SUPPORT AT LEAST 150 POUNDS PER SQUARE FOOT.
WidthDepthHeight
29 ¾"23 ⁄"84"
TR-30 – FRONT VIEW
FIGURE 1 - ROUGH OPENING
FLUSH OPENING DIMENSIONSPROUD OPENING DIMENSIONS
WidthDepthHeight
36 ¼"25 ⁄"84 ¼"
WidthDepthHeight
35 ¾"23 ⁄"84"
TR-30 – TOP VIEW
FIGURE 2 - FLUSH INSTALL
& ELECTRICAL AREA
Electrical located
in this area.
25 25/32"
655mm
8"
(204 mm)
2"
(51 mm)
841/4"
(2140 mm)
FLUSH
INSTALL
FLUSH INSTALL
(2134 mm)
77"
(1956 mm)
293/4"
(756 mm)
301/4"
(769 mm)
PROUD
INSTALL
FLUSH
INSTALL
TRUE RESIDENTIAL
®
84"
PROUD
INSTALL
FIGURE 3 - PROUD INSTALL
23 25/32"
604mm
PROUD INSTALL
NOTE: DIMENSIONS MAY VARY BY ± 1/8”
December 31, 2019 Page 6 of 50
TR-30 – TOP VIEW
TEC_TM_009 Rev. B
TR-30 – TOP VIEWTR-30 – FRONT VIEW
29 9/16"
135°
20 11/16"
525mm
90°
55 1/4"
1403mm
23 25/32"
604mm
29 15/32"
748mm
31 15/32"
799mm
29 9/16"
751mm
135°
20 11/16"
525mm
TR-30DZW-R-SG-A
25 25/32"
655mm
27 29/32"
709mm
30 15/32"
774mm
2 9/16"
65mm
3 15/16"
100mm
135°
20 19/32"
523mm
23 25/32"
604mm
55 1/4"
1403mm
29 15/32"
748mm
31 15/32"
799mm
90°
29 9/16"751mm
TR-30REF-R-SS-A
R
36"
3 15/16"
100mm
27 29/32"
709mm
25 25/32"
655mm
30 15/32"
774mm
2 9/16"
65mm
90°
23 25/32"
604mm
35 9/16"
903mm
61 1/4"
1556mm
37 15/32"
952mm
35 15/32"
901mm
135°
24 13/16"
631mm
TR-36REF-R-SS-A
R
135°
24 13/16"
631mm
TR-36REF-R-SS-A
90°
23 25/32"
604mm
35 9/16"
903mm
61 1/4"
1556mm
37 15/32"
952mm
35 15/32"
901mm
135°
24 13/16"
631mm
TR-36REF-R-SS-A
90°
23 25/32"
604mm
35 9/16"
903mm
61 1/4"
1556mm
37 15/32"
952mm
35 15/32"
901mm
135°
24 13/16"
631mm
TR-36REF-R-SS-A
135°
20 19/32"
523mm
23 25/32"
604mm
55 1/4"
1403mm
29 15/32"
748mm
31 15/32"
799mm
90°
29 9/16"751mm
TR-30REF-R-SS-A
30"
762mm
67 29/32"
1725mm
DOOR
HEIGHT
72 5/8"
1845mm
83 15/16"
2132mm
TR-30 – SIDE VIEW
30 15/32"
774mm
27 29/32"
709mm
25 25/32"
655mm
2 9/16"
65mm
3 15/16"
100mm
TR-36 – TOP VIEWTR-36 – FRONT VIEW
TEC_TM_009 Rev. B
December 31, 2019 Page 7 of 50
67 29/32"
1725mm
DOOR
HEIGHT
NOTE: DIMENSIONS MAY VARY BY ± 1/8”
915mm
TR-36 – SIDE VIEW
2 9/16"
83 15/16"
2132mm
72 5/8"
1845mm
65mm
3 15/16"
100mm
30 15/32"
774mm
27 29/32"
709mm
25 25/32"
655mm
ELECTRICAL REQUIREMENTS
TR-3 0/T R-36
For all built-in models, the electrical supply should be
located within the shaded area shown in the illustration.
Follow the National Electrical Code and local codes
and ordinances when installing the receptacle. A
dedicated circuit, supplying only this appliance is
required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
person in order to avoid a hazard.
• POWER SUPPLY 115 V AC, 60 HZ
• CIRCUIT BREAKER 15 AMP
• RECEPTACLE 3-PRONG GROUNDING-TYPE
NOTES:
• THE OUTLET MUST BE CHECKED BY A
QUALIFIED ELECTRICIAN TO BE SURE THAT
IT IS WIRED WITH THE CORRECT POLARITY.
• VERIFY THAT THE OUTLET IS PROPERLY
GROUNDED.
TR-30/TR-36 – FRONT VIEW
ROUGH OPENING &
ELECTRICAL AREA
Electrical located
in this area.
8"
(204 mm)
293/4"
(756 mm)
301/4"
(769 mm)
PROUD
INSTALL
FLUSH
INSTALL
2"
(51 mm)
(2140 mm)
84"
(2134 mm)
PROUD
INSTALL
77"
(1956 mm)
841/4"
FLUSH
INSTALL
ANTI-SWEAT FOAM END PANELS
When installing two units side-by-side, it is recommended to leave a 5⁄8 " gap between the cabinets, to ensure
that moisture does not develop. Anti-sweat foam end panels can be purchased from our parts department by
calling (844) 849-6226, or emailing trueresidentialparts@truemfg.com. If installing anti-sweat foam end panels,
we recommend that a panel be applied to each of the units being joined together.
TRUE RESIDENTIAL
®
December 31, 2019 Page 8 of 50
TEC_TM_009 Rev. B
PLAN VIEWS
t r - 3 0 / t r - 4 2
t r - 3 0 / t r - 4 8
9 - 16
t r - 3 0 / t r - 3 0
t r - 3 0 / t r - 3 0 / t r - 3 0
t r - 3 6 / t r - 3 6
t r - 3 6 / t r - 3 0
TEC_TM_009 Rev. B
PRESERVE THE MOMENT
December 31, 2019 Page 9 of 50
®
TR-30 / TR-42
TR-42,30DZW
R
23 25/32"
604mm
PROUD INSTALL
TR-42,30DZW
R
TR-42,30DZW
30 15/32"
TR-42,30DZW
R
FLUSH OPENING DIMENSIONSPROUD OPENING DIMENSIONS
WidthDepthHeight
72¼"25 ⁄"84 ¼"
WidthDepthHeight
71¾"23 ⁄"84"
NOTE: DIMENSIONS MAY VARY BY ± 1/
8
"
FLUSH VS. PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
23 25/32"
604mm
PROUD INSTALL
PLAN VIEW
72 1/32"
1829mm
ROUGH OPENING & ELECTRICAL AREA
30 1/8"
71 3/4" PROUD INSTALL
72 1/4" FLUSH INSTALL
77"
7" TYP
2"
PROUD
INSTALL
84 1/4"
84"
FLUSH
INSTALL
774mm
2 9/16"
27 29/32"
65mm
709mm
25 25/32"
655mm
83 15/16"
2132mm
TRUE RESIDENTIAL
3 15/16"
100mm
®
December 31, 2019 Page 10 of 50
TEC_TM_009 Rev. B
TR-30 / TR-48
TR-48,30DZW
R
23 25/32"
604mm
PROUD INSTALL
TR-48,30DZW
R
TR-48,30DZW
TR-48,30DZW
R
FLUSH OPENING DIMENSIONSPROUD OPENING DIMENSIONS
WidthDepthHeight
78¼"25 ⁄"84 ¼"
WidthDepthHeight
77¾"23 ⁄"84"
NOTE: DIMENSIONS MAY VARY BY ± 1/
8
"
FLUSH VS. PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
23 25/32"
604mm
PROUD INSTALL
PLAN VIEW
78 1/32"
1982mm
ROUGH OPENING & ELECTRICAL AREA
77 3/4" PROUD INSTALL
78 1/4" FLUSH INSTALL
30 1/8"
77"
7" TYP
2"
PROUD
INSTALL
84 1/4"
84"
FLUSH
INSTALL
30 15/32"
2 9/16"
65mm
774mm
27 29/32"
709mm
25 25/32"
655mm
83 15/16"
2132mm
TEC_TM_009 Rev. B
3 15/16"
December 31, 2019 Page 11 of 50
100mm
TR-3 0 / T R-30
TR-30REF,30DZW
R
23 25/32"
604mm
PROUD INSTALL
TR-30REF,30DZW
R
TR-30REF,30DZW
30 15/32"
TR-30REF,30DZW
R
FLUSH OPENING DIMENSIONSPROUD OPENING DIMENSIONS
WidthDepthHeight
60¼"25 ⁄"84 ¼"
WidthDepthHeight
59¾"23 ⁄"84"
NOTE: DIMENSIONS MAY VARY BY ± 1/
8
"
FLUSH VS. PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
23 25/32"
604mm
PROUD INSTALL
PLAN VIEW
60 1/32"
1525mm
ROUGH OPENING & ELECTRICAL AREA
30 1/8"
59 3/4" PROUD INSTALL
60 1/4" FLUSH INSTALL
77"
7" TYP
2"
PROUD
INSTALL
84 1/4"
84"
FLUSH
INSTALL
774mm
2 9/16"
65mm
27 29/32"
709mm
25 25/32"
655mm
83 15/16"
2132mm
TRUE RESIDENTIAL
®
December 31, 2019 Page 12 of 50
3 15/16"
100mm
TEC_TM_009 Rev. B
TR-30 / TR-30 / TR-30
TR-30REF,30FRZ,30DZW
R
23 25/32"
604mm
PROUD INSTALL
TR-30REF,30FRZ,30DZW
R
TR-30REF,30DZW
R
TR-30REF,30FRZ,30DZW
R
FLUSH OPENING DIMENSIONSPROUD OPENING DIMENSIONS
WidthDepthHeight
90¼"25 ⁄"84 ¼"
WidthDepthHeight
89 ¾"23 ⁄"84"
FLUSH VS. PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
23 25/32"
604mm
PROUD INSTALL
PLAN VIEW
90 1/32"
2287mm
ROUGH OPENING & ELECTRICAL AREA
30 1/8" 30 1/8"
89 3/4" PROUD INSTALL
90 1/4" FLUSH INSTALL
7" TYP
2"
77"
84"
PROUD
INSTALL
84 1/4"
FLUSH
INSTALL
30 15/32"
2 9/16"
65mm
774mm
27 29/32"
709mm
25 25/32"
655mm
83 15/16"
2132mm
TEC_TM_009 Rev. B
December 31, 2019 Page 13 of 50
3 15/16"
100mm
TR-3 6 REF / TR-36REF
TR-36REF, TR-36REF
TR-36REF,36REF
R
TR-36REF,36REF
R
FLUSH OPENING DIMENSIONSPROUD OPENING DIMENSIONS
WidthDepthHeight
72¼"25 ⁄"84 ¼"
WidthDepthHeight
71¾"23 ⁄"84"
NOTE: DIMENSIONS MAY VARY BY ± 1/
8
"
FLUSH VS. PROUD INSTALL
23 25/32"
604mm
PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
ROUGH OPENING & ELECTRICAL AREA
36 1/8"
71 3/4" PROUD INSTALL
72 1/4" FLUSH INSTALL
77"
8" TYP
2"
PROUD
INSTALL
84 1/4"
84"
FLUSH
INSTALL
PLAN VIEW
83 15/16"
2132mm
72 1/32"
1829mm
2 9/16"
65mm
30 15/32"
774mm
27 29/32"
709mm
25 25/32"
655mm
TRUE RESIDENTIAL
3 15/16"
100mm
®
December 31, 2019 Page 14 of 50
TEC_TM_009 Rev. B
TR-3 6 REF / TR-30R EF
84 1/4"
INSTALL
TR-36REF, TR-30REF
TR-36REF,30RFRZ
TR-36REF,30REF
R
FLUSH OPENING DIMENSIONSPROUD OPENING DIMENSIONS
WidthDepthHeight
66¼"25 ⁄"84 ¼"
WidthDepthHeight
65¾"23 ⁄"84"
NOTE: DIMENSIONS MAY VARY BY ± 1/
8
"
FLUSH VS. PROUD INSTALL
23 25/32"
604mm
PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
ROUGH OPENING & ELECTRICAL AREA
30 1/8"
65 3/4" PROUD INSTALL
66 1/4" FLUSH INSTALL
77"
8" TYP
2"
PROUD
INSTALL
84"
FLUSH
PLAN VIEW
2 9/16"
65mm
66 1/32"
1677mm
30 15/32"
774mm
27 29/32"
709mm
25 25/32"
655mm
83 15/16"
2132mm
TEC_TM_009 Rev. B
3 15/16"
December 31, 2019 Page 15 of 50