Trueheat RCT & RCR IO Manual Page 18 of 20
TROUBLESHOOTING
For all technical queries regarding troubleshooting please contact Comcater Technical Support:
Phone: 1800 810 161 Email: techsupport@comcater.com.au
Problem Probable Causes Corrective Action
Burner will not light
Pilot is not lit
Light the pilot as per
instructions shown on the
inside of the door or on Page
14 of this manual
Gas Control is set to “Pilot”
Once a pilot has been
established, ensure that the
gas control dial is set to
“Hi-Flame” for open burners
& griddle burners or the
desired set point temperature
for ovens.
No gas supplied to unit
Verify that the gas line is
connected, ensure all manual
or automatic shutoff valves are
open, including emergency gas
shut-offs. Note: some exhaust
systems have a gas supply
interlock fitted, that will
disrupted gas supply to the
equipment if the exhaust hood
isn’t operating.
Pilot will not light
Pilot injector has a blockage
or
Gas pressure is too low
When the pilot is lit, the flame
is too small to activate the
thermocouple and hold the
pilot on.
The repair is beyond the scope
of the operator, please call
Comcater service to organise a
technician.
Pilot lights, but will not stay lit
When the pilot is lit, the flame
is good, but the pilot won’t stay
lit, or drops out during service.
The repair is beyond the scope
of the operator, please call
Comcater service to organise a
technician.