Trueheat RCB Infrared Gas Broiler—September 2017 Page 16 of 16
TROUBLESHOOTING
For all technical queries regarding troubleshooting please contact Comcater Technical Support:
Phone: 1800 810 161 Email: techsupport@comcater.com.au
Problem Probable Causes Corrective Action
Burner will not light
Pilot is not lit
Light the pilot as per
instructions shown on the
inside of the door or on Page
13 of this manual
Gas Control is set to “Pilot”
Ensure that the gas control dial
is set to “Hi-Flame”
No gas supplied to unit
Verify that the gas line
connections are connected,
ensure all shutoff valves are
open, including emergency gas
shut-offs. Note: some exhaust
systems have a gas supply
interlock fitted, that will
disrupted gas supply to the
equipment if the exhaust hood
isn’t operating.
BROILER isn’t getting
Hot, (Infrared hoods are
not glowing)
Gas Control is set to the
“Low flame” setting
Ensure the gas control knob is
set to the “Hi flame” setting,
low flame is used as a standby
or rest feature only.
When the gas control is set to
the “Low flame Setting the
infrared hoods will not glow.
Large or small infrared hoods are
incorrectly aligned or haven’t
been fitted after cleaning.
When the BROILER is cool to
touch, remove the cooking
grates and ensure that all
hoods are present and
correctly positioned per
diagram on page 13.
If in doubt Contact Service
Gas pressure is too low
Isolating the problem requires
additional troubleshooting
beyond the scope of the
operator. Contact Service