True blue power TI1200 Series Installation Manual And Operating Instructions

INSTALLATION MANUAL AND
OPERATING INSTRUCTIONS
TI1200-( ) Series
Static Electrical Power Inverter
True Blue Power® is a division of Mid-Continent Instrument Co., Inc.
Mid-Continent Instrument Co., Inc. dba Mid-Continent Instruments and Avionics 9400 E. 34 Wichita, KS 67226 Rev B, July 23, 2012
th
Street N. Manual Number 9017680
True Blue Power, Wichita, KS
FOREWORD
This manual provides information intended for use by persons who, in accordance with current regulatory requirements, are qualified to install this equipment. If further information is required, please contact:
True Blue Power
c/o Mid-Continent Instrument Co., Inc.
Attn: Customer Service Dept.
9400 E. 34
th
St. N.
Wichita, KS 67226 USA
Phone 316-630-0101
Fax 316-630-0723
www.truebluepowerusa.com
www.mcico.com
We welcome your comments concerning this manual. Although every effort has been made to keep it free of errors, some may occur. When reporting a specific problem, please describe it briefly and include the manual part number, the paragraph/figure/table number, and the page number. Send your comments to:
True Blue Power
c/o Mid-Continent Instrument Co., Inc.
Attn: Technical Publications
9400 E. 34
th
St. N.
Wichita, KS 67226 USA
Phone 316-630-0101
Fax 316-630-0723
Copyright 2012
Mid-Continent Instrument Co., Inc.
REV. B July 23, 2012 2 Manual Number 9017680
True Blue Power, Wichita, KS
REVISION DETAIL
Rev.
Date Approved Detail
A 04/27/12 JRC Initial release. B 7/23/12 JDS/MKN Page 9; view overlaps. Page 15 (TS) and (TDS) 501 was 500.
REV. B July 23, 2012 3 Manual Number 9017680
True Blue Power, Wichita, KS
TABLE OF CONTENTS
SECTION 1 GENERAL DESCRIPTION
1.1 INTRODUCTION
1.2 TECHNICAL SPECIFICATIONS
1.2.1 ELECTRICAL ATTRIBUTES
1.2.2 PHYSICAL ATTRIBUTES
1.2.3 QUALIFICATIONS
SECTION 2 INSTALLATION CONSIDERATIONS
2.1 COOLING
2.2 EQUIPMENT LOCATION
2.3 ROUTING OF CABLES
2.4 LIMITATIONS
SECTION 3 INSTALLATION PROCEDURE
3.1 GENERAL INFORMATION
3.2 UNPACKING AND INSPECTING
3.3 CABLE HARNESS
3.3.1 WIRE GAUGE SELECTION
3.3.2 PIN ASSIGNMENT INFORMATION
3.3.3 HARNESS VERIFICATION
3.4 MOUNTING
3.5 INSTALLATION COMPLETION
SECTION 4 OPERATION
4.1 ELECTRICAL PERFORMANCE
4.2 PROTECTIVE FEATURES
SECTION 5 CONFORMANCE
5.1 CONTINUED AIRWORTHINESS STATEMENT
5.2 ENVIRONMENTAL QUALIFICATION STATEMENT
NUMBER LIST OF TABLES AND FIGURES
1.1 ELECTRICAL ATTRIBUTES TABLE
1.2 PHYSICAL ATTRIBUTES TABLE
1.3 PERFORMANCE TABLE
3.3 CONNECTOR PINOUT FIGURE
3.3 CONNECTOR PINOUT TABLE
3.4 EXAMPLE WIRING DIAGRAMS
3.5 TI1200 OUTLINE DRAWING FIGURE
4.1 TEMPERATURE PERFORMANCE
4.2 OUTPUT POWER VS VOLTAGE PERFORMANCE
4.3 OUTPUT POWER VS ALTITUDE PERFORMANCE
REV. B July 23, 2012 4 Manual Number 9017680
True Blue Power, Wichita, KS
SECTION 1 GENERAL DESCRIPTION
1.1 INTRODUCTION
The model TI1200 series Static Electrical Power Inverter is a lightweight power converter that translates a 20 to 36 VDC input to a 115 VAC output at 60 Hertz and provides 1200 watts (VA) of power. The alternating current output is defined as a pure sine wave with less than 2.5% of total harmonic distortion for clean, noise-free, harmonic-free power to supply nearly any common commercial or consumer load rated for a nominal input of 115VAC. The TI1200 series Inverter is FAA certified to TSO C73 and tested to rigorous environmental standards and levels of RTCA DO-160. The small size and light weight in conjunction with its installation flexibility (inside or outside the pressure vessel) make it an ideal choice for aircraft power needs while reducing the challenges associated with other similar products.
Highlighted features include short circuit protection, overload capability, low voltage shut-down, temperature monitoring, a self-resettable over-temperature disable, and a remote on/off function. The rugged extrusion that houses the unit is designed to help dissipate heat and provide mechanical strength against vibration or other possibilities of damage. Two independent fans allow for a smaller uni t and provide a quieter operation while keeping the internal components cool and extending the life of the unit.
1.2 TECHNICAL SPECIFICATIONS
1.2.1 ELECTRICAL ATTRIBUTES
Characteristics:
Input Voltage: Rated 28VDC nominal; 20-36VDC certified; see figure 4.2 Input Power: 60 amps; 0.2A at no load Output Voltage: 115VAC ±3% at 60 Hertz ±0.1% (single phase) Output Power: 1200 watts (1200 VA at power factor = 1) Output Waveform: Pure sine wave (less than 2.5% distortion) Power Factor: -0.8 to +0.8 Efficiency: 88% nominal Total Harmonic Distortion (THD): < 3%
Table 1.1
1.2.2 PHYSICAL ATTRIBUTES
Characteristics:
Weight: 7.25 pounds Dimensions: (not including connector mate)
Mating Connector (and cable clamp): MS3102A24-12S or equivalent (MCI P/N 9017235) Mounting: Base mount – orientation not critical
1.2.3 QUALIFICATIONS
Specifications:
Qualification: FAA TSO-C73 Environmental Qualification: RTCA DO-160G Environmental Category
Altitude: -15,000 ft to +55,000 ft; See Figure 4.3 Temperature: -55°C to +70°C (-67°F to +158°F); See Figure 4.1
12.00 inches long
6.32 inches wide
3.45 inches high
Table 1.2
F3(Y)S2BB[(RCC1)(UG)]XXXXXXZXXXXXBXXXXX
Table 1.3
REV. B July 23, 2012 5 Manual Number 9017680