TRSYS ER3E, ER3E, ER3J, ER3J, ER3G Datasheet

...
ER3A THRU ER3J
SURFACE MOUNT SUPERFAST RECTIFIER
VOLTAGE - 50 to 600 Volts CURRENT - 3.0 Amperes
FEATURES
l For surface mounted applications l Low profile package l Built-in strain relief l Easy pick and place l Superfast recovery times for high efficiency l Plastic package has Underwriters Laboratory
Flammability Classification 94V-O
l Glass passivated junction l High temperature soldering:
260/10 seconds at terminals
MECHANICAL DATA
Case: JEDEC DO-214AB molded plastic Terminals: Solder plated, solderable per MIL-STD­750, Method 2026
SMC/DO-214AB
Polarity: Indicated by cathode band Standard packaging: 16mm tape (EIA-481) Weight: 0.007 ounce, 0.21 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%.
Maximum Recurrent Peak Reverse Voltage V Maximum RMS Voltage V Maximum DC Blocking Voltage VDC Maximum Average Forward Rectified Current, at TL=75 Peak Forward Surge Current 8.3ms single half sine­wave superimposed on rated load(JEDEC method) Maximum Instantaneous Forward Voltage at 3.0A VF 0.95 1.25 1.7 Volts Maximum DC Reverse Current TA=25 At Rated DC Blocking Voltage TA=100
SYMBOLS ER3A ER3B ER3C ER3D ER3E ER3G ER3J UNITS
50 100 150 200 300 400 600 Volts
RRM RMS
I
(AV)
I
FSM
IR 5.0
35 70 105 140 210 280 420 Volts 50 100 150 200 300 400 600 Volts
3.0 Amps 100 Amps
A
200 Maximum Reverse Recovery (Note 1) TRR 35.0 nS Typical Junction capacitance (Note 2) CJ 45.0
F
P
Typical Thermal Resistance (Note 3) RJL 16 /W Operating and Storage Temp TJ,T
-50 to +150
STG
NOTES:
1. Reverse Recovery Test Conditions: IF=0.5A, IR=1.0A, Irr=0.25A
2. Measured at 1 MHz and Applied reverse voltage of 4.0 volts
3. 8.0mm2 (.013mm thick) land areas RATING AND CHARACTERISTIC CURVES ER3A THRU ER3J
Fig. 1-REVERSE RECOVERY TIME CHARACTERISTIC Fig. 2-MAXIMUM AVERAGE FORWARD AND TEST DIAGRAM CURRENT RATING
Fig. 3-TYPICAL REVERSE CHARACTERISTICS Fig. 4-TYPICAL FORWARD CHARACTERISTICS
Fig. 5-MAXIMUM NON-REPETITIVE PEAK FORWARD Fig. 6-TYPICAL JUNCTION CAPACITANCE
SURGE CURRENT