Trotec TWP 7505 E operation manual

TWP 4005 E / TWP 7505 E / TWP 9005 E
EN
OPERATING MANUAL
SUBMERGED CLEAR WATER PUMP, NEAR-GROUND SUCTION
TRT-BA-TWP4005E-TWP7505E-TWP9005E-TC2018-62-002-EN

Table of contents

Other symbols used on the device:
Notes regarding the operating manual................................. 2
Safety .....................................................................................3
Information about the device................................................6
Transport and storage...........................................................7
Assembly and installation.....................................................7
Operation .............................................................................11
Errors and faults..................................................................12
Maintenance ........................................................................13
Technical annex...................................................................14
Disposal ...............................................................................16

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
General warning sign
This symbol indicates that you must be aware of the dangers that can occur when working with the device.
Device may start up without warning
This symbol indicates that the device may start up without warning when it is switched on.
Do not use damaged power cables or mains plugs
This symbol indicates that the device must no longer be operated if the power cable is damaged.
Staying in water prohibited
This symbol indicates that the device must not be operated with persons or animals in the water.
Do not use at freezing temperatures
This symbol indicates that the device must be protected from frost.
Keep out of the reach of children – not a toy
This symbol indicates that the device is not a toy and is thus not suitable for children.
Do not pull the mains plug by the power cable
This symbol indicates that you must not pull the mains plug out of the socket by the power cable.
Pull the mains plug
This symbol indicates that the mains plug must be removed from the socket when the device is not in use.
Not suitable for pumping potable water
This symbol indicates that the device is not suitable for pumping potable water.
Submerge pump at a slight angle
This symbol indicates that the pump must be submerged into the water at a slight angle to allow the remaining air to escape.
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
2 EN
You can download the current version of the operating manual and the EU declaration of conformity via the following link:
TWP 4005 E
http://hub.trotec.com/?id=40406
TWP 7505 E
https://hub.trotec.com/?id=42885
TWP 9005 E
https://hub.trotec.com/?id=42886

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
General safety
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
General safety warnings – Electrical safety
The device is to be supplied with a rated residual current of no more than 30mA by means of an RCD (Residual Current protective Device).
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk!
Should the connection line of the device be damaged, it must be replaced by the manufacturer, his customer service or similarly qualified personnel in order to avoid hazards.
Should there be a risk of flooding, install the plug connections in a flood-proof area. There is a risk of
electric shock!
Make sure that the mains voltage corresponds to the specifications on the nameplate.
Have all electrical installations carried out by an expert according to the national regulations and the device­specific requirements.
Do not use the power cable to drag the device.
EN 3
Hold onto the mains plug while pulling the power cable out of the mains socket.
Protect the power supply cable against heat, oil and sharp edges.
Only use splash-proof extension cables intended for outdoor use whilst observing the device's power input. Before using cable drums, always unroll the cable completely. Check the cable for damage.
Before performing any work on the device, in case of leaks in the water system, before taking work breaks or when not in use, remove the mains plug from the mains socket.
General safety warnings – Personal safety
Never use the device with persons or animals in the water or pumping medium or if they could access it. There is a
risk of electric shock!
Never insert any objects or limbs into the device.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Device-specific safety warnings for submerged pumps
Do not leave the device running unattended to ensure an early detection of when the device runs dry or switches off automatically. This would damage the device. Regularly check the float for proper functioning.
Please bear in mind, that the device is not suitable for continuous operation (e.g. for watercourses in garden ponds). Check the device for proper functioning on a regular basis.
Keep in mind, that lubricants are used within the device. These might potentially cause damages or contaminations if emitted. Do not use the device for drinking water or in garden ponds with either a fish population or valuable plants.
The device is not to be carried by holding it at the power supply cable or hose. Do not fasten it there either.
Do not place any objects on the device – not even to weight it down. The device will sink to the ground due to its own weight.
After the set-up of the device, its mains plug must be readily accessible during operation.
Wear sturdy shoes to protect yourself against electric shock.
Before taking the device into operation, have the following checked by an expert:
– earthing, neutral conductor and RCD must be
functioning properly and correspond to the national regulations,
– electrical plug connections must be protected from
moisture.
Provide appropriate frost protection.

Intended use

The device TWP 4005 E / TWP 7505 E/ TWP 9005 E is only suited for draining, conveying and pumping over the following media:
clear water
non-corrosive suds (e.g. leaking washing machine)
slightly chlorinated water
When doing so, the water must not contain any suspended matter exceeding a maximum particle size of 5mm.
The device is fully submersible (watertight encapsulation) and can be immersed up to 7m into the conveyed medium.
The water temperature must not exceed 35°C. The device may temporarily be used for e.g.:
pumping out flooded basements
emptying tanks and containers
the water withdrawal from wells and shafts
4 EN

Improper use

The device is not suitable for continuous operation (e.g. as recirculation pump for ponds).
Using the device in swimming pools and the like is prohibited.
The device is not suitable as permanent, automatic overflow protection of e.g. wells or fountains or for the regulation of the groundwater level. Use a stationary waste water pumping system for building and property drainage for these purposes.
The device is not suitable for increasing the pressure of existing water supply networks.
The device is not suitable for pumping potable water.
The device must not be used for aggressive, abrasive, caustic, combustible or explosive pumping media, e.g.:
– brine – sandy water – food – cleaning agents – fuels (e.g. petrol, diesel) – oils – greases – petroleum – nitro-cellulose thinner – waste water from lavatories and urinal installations
The device must not be used at freezing temperatures.
Any unauthorised modifications, alterations or structural changes to the device are forbidden.
Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the operating manual, especially the Safety chapter.

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Note
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Behaviour in the event of an emergency

1. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
2. Do not reconnect a defective device to the mains.

Overheating protection

The device is provided with a thermal protection circuit which is activated by overheating of the device and then switches the device off.
Allow the device to cool down and switch it off. Investigate the cause of overheating. Should the problem persist, please contact the customer service.
EN 5

Information about the device

1
2
3
4
5
6
7
8
10
9
Ø 25 mm
1''
1 ½''
Ø 32 mm
11

Device description

The submerged clear water pump TWP 4005 E / TWP 7505 E/
TWP 9005 E is suited for draining, conveying and pumping over
clear water with the contained suspended matter not exceeding a maximum particle size of 5mm.
The device comes with near-ground suction and can extract clear water up to a residual height of 3mm.
A float ensures the automatic switch-on and switch-off at a respectively defined height. Additionally, the switch-on/-off height can be finely adjusted within the specified range by means of a locking device, see technical data.
The water temperature must not exceed 35°C.
Info
The illustrations in this operating manual feature the device TWP4005E by way of example. However, the depicted operating steps and explanations also apply to the devices TWP7505E and TWP9005E unless otherwise mentioned.

Device depiction

No. Designation
1 Transport handle / attachment for nylon cord
2 Power cable
3 Float switch locking device
4 Float switch
5 Air intake opening
6 Connection with 1½"internal thread
7 Reducer
8 Elbow
9 Backflow preventer
10 Retainer (for backflow preventer)
11 Seal ring
6 EN