Trotec TTR 57 E Operating Manual

Page 1
TTR 57 E
EN
OPERATING MANUAL
DEHUMIDIFIER
TRT-BA-TTR57E-TC2018-46-001-EN
Page 2

Table of contents

You can download the current version of the operating manual and the EU declaration of conformity via the following link:

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
TTR 57 E
https://hub.trotec.com/?id=42658

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Let the device dry out after a wet clean. Do not operate it when wet.
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
Do not sit on the device.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
2 EN
dehumidifier TTR 57 E
Page 3
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk!
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
Make sure that the air inlet and outlet are not obstructed.
Make sure that the suction side is kept free of dirt and loose objects.
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
Only transport the device in an upright position with an emptied condensation tank or drain hose.
Discharge the collected condensate before transport and storage. Do not drink it. Health hazard!

Intended use

Only use the device for drying and dehumidifying room air, while adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry.
Intended use comprises:
dehumidifying and drying:
– living rooms, bedrooms, bathrooms and basements – laundries, holiday homes, camper vans, boats
maintaining the dryness of:
– storage spaces, archives, laboratories, garages – bathrooms, wash rooms, changing rooms etc.

Improper use

The device is not intended for industrial use.
Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, alterations or structural changes to the device are forbidden.
Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the operating manual, especially the Safety chapter.
Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.
EN 3
dehumidifier TTR 57 E
Page 4

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

Behaviour in the event of an emergency

1. Switch off the device.
2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
3. Do not reconnect a defective device to the mains.

Information about the device

Description of the device

The TTR57E operates on the desiccant principle, without compressor or refrigerant.
The fully automatic control and the condensation tank with integrated overflow protection ensure fault-free operation.
The fan sucks in damp room air via the air inlet with air filter, the condenser and the desiccant wheel located behind it.
Within the internal regeneration circuit the air is led via a heating element, it dries the desiccant wheel and leads the moist, warm air through the condenser. At the cooler condenser, heat is withdrawn from the room air and cooled below dew point. The water vapour contained in the room air precipitates in form of condensate. The condensate drops into the condensation tank. Optionally, the condensate can be discharged via a condensation hose connected to the connection opening.
The drier air, thus conditioned, is fed back to the room air via the air outlet. The drier air mixes with the air in the room. The relative humidity in the room where the device is positioned is reduced by the constant circulation of the room air.
A float is attached inside the condensation tank, which in case of a filled condensation tank interrupts the dehumidification. When switching off, the device emits an acoustic signal and the Tank Full LED on the control panel is illuminated (see chapter Operating elements). The indicator light only goes out again once the emptied condensation tank is reinserted.
The device can reduce the relative humidity of a room to approx. 40%.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry.
4 EN
dehumidifier TTR 57 E
Page 5

Device depiction

2
1
3
4
5
1
2
6
7
8
5
3

Transport and storage

Note
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

To make the device easier to transport, it is fitted with a carry handle.
Before transporting the device, observe the following:
Switch the device off.
– Due to the follow-up time of the internal components,
the device only switches off completely after approx. 2 minutes.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Do not use the power cable to drag the device.
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
No. Designation
1 Control panel
2 Handle
3 Air outlet
4 Colour LEDindication for humidity level
blue=humidity >70% green=humidity 50%–70% red=humidity<50%
5 Condensation tank
6 Air inlet with air filter
7 Power cable
8 Connection opening for condensation hose
After transporting the device, observe the following:
Set up the device in an upright position after transport.
Leave the device to rest for one hour before switching it back on. Otherwise the device could be damaged and no longer work properly. Any warranty claims will be voided in this case.

Storage

Before storing the device, proceed as follows:
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
Empty and clean the condensation tank prior to storage.
Hold onto the mains plug while pulling the power cable out of the mains socket.
When the device is not being used, observe the following storage conditions:
dry and protected from frost and heat
in an upright position where it is protected from dust and direct sunlight
with a cover to protect it from invasive dust if necessary
Place no further devices or objects on top of the device to prevent it from being damaged.
EN 5
dehumidifier TTR 57 E
Page 6

Assembly and installation

A
B
C
C
D
26256

Scope of delivery

1x Device
1x Air filter
1x Activated carbon filter
1x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.

Start-up

When positioning the device, observe the minimum distance from walls or other objects as described in the Technical data chapter.
Make sure that no curtains or other objects interfere with the air flow.
When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations.
Notes regarding the dehumidification performance
The dehumidification performance depends on:
the layout of the room
the room temperature
the relative humidity
The higher the room temperature and relative humidity, the greater the dehumidification performance.
For use in living rooms, a relative humidity of approx. 50 to 60% is sufficient. In storage facilities and archives, the humidity should not exceed approx. 50%.
Inserting the air filter
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
Make sure that the air filter is installed before switching the device on.
No. Operating element
6 Air filter
Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service.
Set the device up in an upright and stable position.
Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning
25 HEPA filter (optional)
26 Activated carbon filter
the device in the middle of the room. Use cable bridges.
Make sure that extension cables are completely unrolled.
When positioning the device, keep a sufficient distance to heat sources.
6 EN
dehumidifier TTR 57 E
Page 7
Opening the ventilation flaps
16 17 18 19 20
21 22
23 24
13 14 15
9 10 11 12
1. Prior to switching the device on, open the ventilation flaps at the air outlet.
Inserting the condensation tank
Ensure that the float inside the condensation tank is inserted correctly.
Ensure that the condensation tank is empty and inserted correctly.
Connecting the power cable
Insert the mains plug into a properly secured mains socket.

Operation

After being switched on, the device operates fully automatically – depending on the selected operating mode or until the float indicates that the condensation tank is full and the device switches itself off.
Avoid open doors and windows.
Operating elements
No. Designation Meaning
9 low LED Indication of low fan speed
10 med LED Indication of medium fan speed
11 high LED Indication of high fan speed
12 Segment display Indicates the room temperature
(0 to 50°C) Indicates the ambient air's relative humidity (35% to 95%RH) Indicates the set humidity level when pressing the Humidity button Indicates the preselected hours for approx.8seconds when pressing the Timer button
13 Speed button Sets the fan speed
14 On LED Illuminated in green = operation
indication Flashes red = device tilted (over)
15 Drying LED Laundry drying mode indication
16 Drying button Starts laundry drying mode
17 Humidity button Sets the target humidity value:
continuous operation (CO), 40%, 50%, 60%, 70%
18 On/Off button Switches the device on or off
19 Timer button Starts programming the timer function
20 Ventilation
button
Starts ventilation mode
EN 7
dehumidifier TTR 57 E
Page 8
No. Designation Meaning
21 Auto button Starts automatic mode
> 70% RH = high fan speed 55%–70% RH = low fan speed < 55% RH = The device switches off for 30minutes and will then check the relative humidity level again Automatic start-up at more than 55%RH
22 Tank Full LED Condensation tank full or not positioned
correctly indication
23 Timer LED Timer function indication
24 Ventilation LED Ventilation mode indication
Switching the device on
Once you have completely installed the device as described in the Start-up chapter, you can switch it on.
Note
Wait for 3 minutes before you switch the device back on (e.g. after draining the condensation tank).
1. Use the On/Off button(18) to switch the device on.
ð The device starts to dehumidify.
Setting the operating mode
Ventilation mode
The device can be set to three fan speeds: low, med and high.
Low:
The device operates at a low fan speed and low heating capacity to save energy and keep the operating noise to a minimum. The heating switches off when the relative humidity in the ambient air falls below the set nominal value. If the humidity increases to above the set value, the heating will switch on again. The indication for the room humidity level on the front of the device is deactivated.
Med:
The device operates at normal fan speed and high heating capacity.
High:
The device operates at high fan speed and high heating capacity.
Select the fan speed as follows:
1. Press the Speed button(13) until the low LED(9) is illuminated.
2. Repeatedly press the Speed button(13) until the med LED(10) is illuminated.
3. Repeatedly press the Speed button(13) until the high LED(11) is illuminated.
Setting the desired relative room humidity
You can adjust the desired relative room humidity. The selected room humidity level is indicated on the segment display(12). You can select the following settings: (CO), 40%,50%,60% and 70%. To do so, please proceed as follows:
1. Press the Humidity button(17).
ð The selected room humidity level is indicated on the
segment display(12).
2. Press the Humidity button(17) again until the desired value is shown on the segment display(12).
Continuous operation
The device dehumidifies the air constantly and regardless of the relative humidity.
The desired relative room humidity cannot be adjusted in this operating mode.
1. Use the On/Off button(18) to switch the device on.
2. Press the Humidity button(17) until the segment display(12) shows continuous operation(CO).
For reasons of safety, the device switches off automatically for 30minutes after 8hours of continuous operation. After the 30minutes have passed, the cycle starts again and the device switches back on for another 8hours.
Ambient temperature above 36°C
If the ambient temperature exceeds 36°C, the heating switches off for 30minutes while the fan keeps running. After the 30minutes have passed, the device checks the room humidity and temperature. If the room humidity is higher than the previously selected value, the device switches back on for another 8hours. If the room humidity is lower than this value or if the ambient temperature is higher than 36°C, the device switches off again for another 30minutes.
8 EN
dehumidifier TTR 57 E
Page 9
Colour LED for current room humidity
Regardless of the operating mode, the colour LED indicates the current relative room humidity by means of 3 different colours.
LED colour Meaning
Blue
Relative room humidity above 70%
Green
Optimal relative room humidity between 50% and 70%
Red
Relative room humidity below 50%
Setting the timer
For the device to switch on or off automatically after a predefined number of hours (1 to 24) you can programme the timer. The timer can be programmed in increments of 1hour (1to 24h).
Note
Do not leave the operating device unattended in a freely accessible room with an activated timer.
Operation with hose attached to the condensation connection
At a high humidity level it is recommendable to constantly drain the condensate via a hose, for otherwise the condensation tank has to be emptied too frequently.
To do so, proceed as follows:
ü A suitable hose (diameter: 11mm) is ready for use. ü The device is switched off.
1. Remove the condensation tank(5).
Automatic switch-on
1. Switch the device off.
2. Press and hold the Timer button(19) until the segment display(12) shows the desired duration in hours.
ð The Timer LED(23) is illuminated. ð The number of hours is shown on the segment
display(12).
ð After the predefined time, the device switches itself on.
Automatic switch-off
ü The device is switched on.
1. Press and hold the Timer button(19) until the segment display(12) shows the desired duration in hours.
ð The Timer LED(23) is illuminated. ð The number of hours is shown on the segment
display(12).
ð After the predefined time, the device switches itself off.
2. Push one end of the hose onto the hose connection.
EN 9
dehumidifier TTR 57 E
Page 10
3. Put the condensation tank(5) back in.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Wait for approx. 2 minutes.
– Due to the follow-up time of the internal components,
the device only switches off completely after approx. 2 minutes.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Empty the condensation tank, if need be.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.

Available accessories

4. Guide the other hose end to a suitable drain or sufficiently dimensioned collection container. Please note that the hose must not be kinked.
Drying laundry
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe the minimum distances specified in the technical data.
For drying laundry the following values should be selected:
cupboard dry = 46 % relative humidity
iron dry = 58 % relative humidity
slightly dried = 65 % relative humidity
If necessary, use a measuring device to determine the humidity level.
Warning
Only use accessories and additional equipment specified in the operating manual. Using insertion tools or accessories other than those specified in the operating manual may cause a risk of injury.
Designation Article number
HEPA filter TTR 57 E 7.710.000.051
10 EN
dehumidifier TTR 57 E
Page 11

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Check the condensation tank for correct seating.
The device comes equipped with a tilt protection, it switches off automatically when tilted. The On LED(14) is illuminated in green during operation. When On LED(14) flashes red, check whether device is in an upright position on a level surface.
Check the room temperature. Observe the device's permissible operating range according to the technical data.
At an ambient temperature above 36°C, the heating is switched off automatically making condensate formation impossible.
Wait for 10minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec.
The device is running, but there is no formation of condensate:
Check the float in the condensation tank for dirt. If necessary, clean the condensation tank. The float must be able to move freely.
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Ensure that the relative room humidity complies with the technical data.
Check the air filter for dirt. If necessary, clean or replace the air filter.
From the outside, check the condenser for dirt (see chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec.
The device gets very warm, is loud or loses power:
Check the air inlets and air filters for dirt. Remove external dirt.
From the outside, check the device for dirt (see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company for cooling and air­conditioning or by Trotec.
Note
Wait for at least 3 minutes after maintenance and repair work. Only then switch the device back on.
Your device still does not operate correctly after these checks?
Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright position.
Condensate is leaking:
Check the device for leaks.
EN 11
dehumidifier TTR 57 E
Page 12

Maintenance

Maintenance intervals

Maintenance and care interval before every
start-up
Check air inlets and outlets for dirt
X X
and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and
X X
foreign objects and clean or replace if necessary
Replace the air filter
Check for damage
X
Check the attachment screws
Test run
Empty the condensation tank and drain hose
as needed at least every
2weeks
X X
X X
X X
X
at least every 4weeks
at least every 6months
X
at least annually
X
12 EN
dehumidifier TTR 57 E
Page 13

Maintenance and care log

Device type: .............................................
Device number: ....................................
Maintenance and care interval
Check air inlets and outlets for dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and foreign objects and clean or replace if necessary
Replace the air filter
Check for damage
Check the attachment screws
Test run
Empty the condensation tank and drain hose
Comments
1. Date: ...................................
Signature: ................................
5. Date: ...................................
Signature: ................................
9. Date: ...................................
Signature: ................................
13. Date: .................................
Signature: ................................
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
2. Date: ....................................
Signature: .................................
6. Date: ....................................
Signature: .................................
10. Date: ..................................
Signature: .................................
14. Date: ..................................
Signature: .................................
3. Date: ....................................
Signature: .................................
7. Date: ....................................
Signature: .................................
11. Date: ..................................
Signature: .................................
15. Date: ..................................
Signature: .................................
4. Date: ....................................
Signature: .................................
8. Date: ....................................
Signature: .................................
12. Date: ..................................
Signature: .................................
16. Date: ..................................
Signature: .................................
EN 13
dehumidifier TTR 57 E
Page 14

Activities required before starting maintenance

Cleaning the air filter

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air­conditioning or by Trotec.
5. Put the air filter back in.
Note
Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be deformed or rounded. Before reinserting the air filter, make sure that it is undamaged and dry!
Note
Neither the activated carbon filter nor the HEPA filter(optional) can be cleaned. Both filters must be replaced if required.
The air filter has to be cleaned as soon as it is dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults).
The lifetime of the activated carbon filter or HEPA filter depends on the ambient conditions and the application period of the device.
1. Remove the air filter from the device.
2. Clean the filter using a slightly damp, soft, lint-free cloth. If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent.
14 EN
dehumidifier TTR 57 E
Page 15
3. Allow the filter to dry completely. Do not insert a wet filter into the device!
4. Reinsert the air filter into the device.

Emptying the condensation tank

When the condensation tank(5) is full or not inserted correctly, the device stops dehumidification operation and switches itself off. The Tank Full LED(22) lights up and an acoustic signal is emitted.
1. Take the condensation tank(5) out of the device.
3. Rinse the condensation tank(5) with clear water. Regularly clean the condensation tank(5) using a mild cleaning agent (no dish detergent!).
4. Refit the condensation tank(5) into the device. Make sure not to damage the float when inserting or removing the condensation tank(5).
ð In doing so, make sure that the float is positioned
correctly.
ð In doing so, make sure that the condensation tank(5) is
inserted correctly, for otherwise the device cannot be switched back on.
2. Empty the condensation tank(5) over a drain or sink.

Activities required after maintenance

If you want to continue using the device:
Leave the device to rest for one hour before switching it back on. Otherwise the device could be damaged and no longer work properly. Any warranty claims will be voided in this case.
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
Store the device according to the Storage chapter.
EN 15
dehumidifier TTR 57 E
Page 16

Technical annex

Technical data

Parameter Value
Model TTR 57 E
Max. dehumidification performance
Dehumidification performance at 30°C and 80%RH
Air flow rate 185 m3/h
Operating range (temperature) 1°C to 32°C
Operating range (relative humidity)
Mains connection 1/N/PE~220 –240V/50Hz
Max. power input 730 W
Heating capacity of heating element
Nominal current consumption 3.7A
On-site fusing 10 A
Condensation tank capacity 5 l
Sound pressure level 47 dB(A)
Weight 7.5 kg
Dimensions (length x width x height) 340x 232x 511 mm
Minimum distance to walls and other objects
B: rear C: side
D: front
A: top
9 l/ 24h
8.5l
35% to 90%
650W
60 cm 20 cm 20 cm 50 cm

Disposal

The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
16 EN
dehumidifier TTR 57 E
Page 17
Trotec GmbH & Co. KG
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400 +49 2452 962-200
info@trotec.com www.trotec.com