Trotec TTK 96 E, TTK 127 E Operating Manual

TTK 96 E / TTK 127 E
EN
OPERATING MANUAL
DEHUMIDIFIER
TRT-BA-TTK96E-TTK127E-TC-001-EN

Table of contents

Legal notice

This release replaces all previous versions. No part of this publication may be reproduced without written permission from Trotec. The same applies for electronically processing, duplicating or spreading the publication. Subject to technical changes. All rights reserved. Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer. Product names are registered.
Changes to construction in the interests of constant improvements to the product, as well as changes to the shape and colour are reserved.
The scope of delivery may vary from product images. This document was created with all due care. Trotec accepts no liability whatsoever for possible mistakes or omissions.
© Trotec

Notes regarding the operating manual

Symbols

Hazardous electric current!
Warns about hazards from electric current which can lead to injuries or even death.
Danger!
Warns of a hazard which can lead to personal injury.
Caution!
Warns of a hazard which can lead to property damage.
The current version of the operating manual can be found at:
TTK 96 E

Warranty and liability

The device complies with the fundamental health and safety requirements of the applicable EU regulations and was tested at the factory for perfect functionality multiple times.
However, if faults in the functionality occur and cannot be remedied with the measures in the chapter Errors and faults, please get in touch with your dealer or distributor.
When making a warranty claim, supply the device number (see the rear of the device).
When manufacturer's instructions or legal regulations have not been followed, or after unauthorised changes to the device are made, the manufacturer is not responsible for the resulting damages. Changes to the device or unauthorised replacement of individual parts can drastically impact the electrical safety of this product and leads to the forfeit of the warranty. Liability does not extend to damages to people or property caused by the device being used other than as described in the instructions in this operating manual. Subject to changes to technical design and model changes as part of constant development and product improvement without prior notice.
No liability is accepted for damages resulting from improper use. In such a case, any warranty claims be voided also.
http://download.trotec.com/?sku=1120000101&id=1
TTK 127 E
http://download.trotec.com/?sku=1120000126&id=1
1 EN
Operating manual – dehumidifier TTK 96 E / TTK 127 E

Safety

Carefully read this manual before starting / using the device and keep it within reach.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Ensure that the air inlet and outlet are not obstructed.
Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects.
Never reach or put objects into the device.
Do not cover or transport the device during operation.
Do not use the device with wet or damp hands.
Ensure that all electric cables outside of the device are protected from damage (e.g. from animals). Never use the device if the cable or power connection is damaged!
Only use extensions to the connecting cable which are appropriate to the device power consumption, the length of its cable and its use. Completely unroll extension cables. Avoid electrical overload.
Only transport the device in an upright position with an emptied condensation tank.
Dispose of the collected condensate. Do not drink it. Health hazard!
Pull the plug from the socket if the device is not in use.
Unplug the device from the mains before starting with maintenance, service or repair work.

Intended use

Only use the device TTK 96 E / TTK 127 E for drying and dehumidifying room air, while adhering to and following the technical data.
Intended use comprises:
drying and dehumidifying:
– living rooms, bedrooms or basements – laundries, holiday homes.
maintaining the dryness of:
– storage spaces, archives, laboratories, garages – changing rooms etc.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the operating manual, especially the Safety chapter.

Residual risks

Hazardous electric current!
Work on the electrical components must only be carried out by an authorised specialist company!
Hazardous electric current!
Before any work on the device, remove the mains plug from the mains socket!
Danger!
The device is not a toy and does not belong in the hands of children.
Danger!
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Danger!
Do not leave the packaging lying around. Children may use it as a dangerous toy.
Caution!
To avoid damages to the device, do not operate the device without an air filter inserted!

Behaviour in the event of an emergency

1. In an emergency, disconnect the device from the mains feed-in: Switch the device off and disconnect it from the mains.
2. Do not reconnect a defective device to the mains.

Improper use

Do not place the device TTK 96 E / TTK 127 E on wet or flooded ground. Do not use the device outdoors. Do not place any objects, e.g. wet clothing, on the device for drying.
Any unauthorised changes, modifications or alterations to the device are forbidden.
EN 2
Operating manual – dehumidifier TTK 96 E / TTK 127 E

Information about the device

1
2
3
11
10
9
8
7
4
12
6
5

Description of the device

The device TTK 96 E / TTK 127 E uses the principle of condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter, the evaporator and to the condenser located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator fins as either condensation or rime. The dehumidified, cooled air is slightly warmed and blown out again. The drier air thus conditioned mixes with the air in the room. The humidity in the room where the device is positioned is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the condensed water either drops continuously or only during the defrost phase through the integrated drain nozzle into the condensation tank below. It is fitted with a float to measure the filling level.
The device has a control panel for operating and controlling the functions.
Once the maximum fill level of the condensation tank is reached, the condensation tank indicator light (see chapter Operating elements) on the control panel is illuminated. The device switches off. The condensation tank indicator light only goes out again once the emptied condensation tank is reinserted.
Optionally, the condensed water can be drained by attaching a hose (Ø = 14mm) at the condensation connection.
The device can reduce the relative humidity of a room to approx. 35%.
Because of the heat radiation generated during operation, the room temperature may rise slightly.

Device depiction

No. Designation
1 Transport handle
2 Air outlet
3 Power cable holder
3 EN
Operating manual – dehumidifier TTK 96 E / TTK 127 E
4 Wheels
5 Hose adapter for condensation drain hose
6 Condensation drain hose
7 Power cable
8 Condensation hose connection with sealing cap
9 Air inlet with air filter
10 Filling level indication
11 Condensation tank
12 Control panel

Transport and storage

Transport

To make the device easier to transport, it is fitted with wheels. Before transporting the device, proceed as follows:
1. Pump out any possibly remaining condensate. Check for dripping condensation.
2. Pull the plug from the mains socket. Do not use the power cable to drag the device.
3. Only wheel the device on a level and smooth surface.

Storage

Leave the device to rest for 24hours before storing it. Then empty and clean the condensation tank, the filter and the device prior to storing.
When the device is not being used, observe the following storage conditions:
Dry.
In an upright and stable position.
Protected from dust and direct sunlight.
With a cover to protect it from invasive dust, if necessary.
3. Remove the power cable holder(3), the condensation drain hose(6) and the hose adapter(5) from the condensation tank.
4. Put the condensation tank back in.
5. Press the holder into the provided recess.

Assembly

Scope of delivery
1x dehumidifier
1x air filter
1x power cable holder
1x hose adapter for condensation drain hose
1x condensation drain hose (l = 60cm, Ø = 14mm)
Assembling the power cable holder
1. Unpack the device and remove the cardboard box as well as any other outer packaging.
2. Remove the condensation tank.
ð The holder should click into place.
6. Check the holder for tight fit.
ð If needed, you may now wind the power cable around the
holder.
EN 4
Operating manual – dehumidifier TTK 96 E / TTK 127 E

Set-up and installation

On
Off
Full
Auto defrost
13 14 17 18 19 20
212223242526
15 16
27

Operation

Positioning
When positioning the device, observe the minimum distance from walls or other objects as described in chapter Technical Data.
Set the device up in a level and stable position.
When positioning the device, keep a sufficient distance to heat sources.
When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations.
After being switched on, the device operates fully automatically.
The fan is running continuously until the device is switched off.
Avoid open doors and windows.
Operating elements
No. Designation Meaning
13 FILTER LED Illuminated when the filter needs to be
cleaned.
14 Auto defrost LED Illuminated when the device carries out an
automatic defrost.
15 CONT. LED Illuminated when the device runs in
continuous operation.
16 TURBO LED Illuminated when the fan runs at maximum
power.
17 FULL LED Illuminated when the condensation tank is
full. See chapter Emptying the condensation tank
18 Off LED Illuminated when the timer is programmed for
automatic switch-off.
19 On LED Illuminated when the timer is programmed for
automatic switch-on.
20 Display Indicates the current humidity level.
Indicates the selected humidity value during the humidity setting. Indicates the number of hours during the timer setting.
21 POWER button Switches the device on or off.
22 Selection button Selection button for the humidity level (35%
to 85% in increments of 5%) or the timer function (0 to 10h in increments of 0.5hours or 10 to 24h in increments of 1h)
23 TIMER button Switches the timer function on or off.
24 TURBO button Sets the fan stage.
Stage 1 = normal Stage 2 = function for drying laundry
25 CONT. button Switches continuous operation on or off.
26 FILTER button Resets the cleaning cycle for the filter.
27 COMFORT button Switches comfort mode on or off.
5 EN
Operating manual – dehumidifier TTK 96 E / TTK 127 E
Loading...
+ 11 hidden pages