This release replaces all previous versions. No part of this
publication may be reproduced without written permission from
Trotec. The same applies for electronically processing,
duplicating or spreading the publication. Subject to technical
changes. All rights reserved. Trademarks are used without
guarantee that they may be used freely and primarily following
the spelling of the manufacturer. Product names are registered.
Changes to construction in the interests of constant
improvements to the product, as well as changes to the shape
and colour are reserved.
The scope of delivery may vary from product images. This
document was created with all due care. Trotec accepts no
liability whatsoever for possible mistakes or omissions.
Declaration of conformity ...................................................14
Notes regarding the operating manual
Symbols
Hazardous electric current!
Warns about hazards from electric current which can
lead to injuries or even death.
Danger!
Warns of a hazard which can lead to personal injury.
Caution!
Warns of a hazard which can lead to property damage.
The current version of the operating manual can be found at:
TTK 96 E
Warranty and liability
The device complies with the fundamental health and safety
requirements of the applicable EU regulations and was tested at
the factory for perfect functionality multiple times.
However, if faults in the functionality occur and cannot be
remedied with the measures in the chapter Errors and faults,
please get in touch with your dealer or distributor.
When making a warranty claim, supply the device number (see
the rear of the device).
When manufacturer's instructions or legal regulations have not
been followed, or after unauthorised changes to the device are
made, the manufacturer is not responsible for the resulting
damages. Changes to the device or unauthorised replacement
of individual parts can drastically impact the electrical safety of
this product and leads to the forfeit of the warranty. Liability
does not extend to damages to people or property caused by the
device being used other than as described in the instructions in
this operating manual. Subject to changes to technical design
and model changes as part of constant development and
product improvement without prior notice.
No liability is accepted for damages resulting from improper
use. In such a case, any warranty claims be voided also.
http://download.trotec.com/?sku=1120000101&id=1
TTK 127 E
http://download.trotec.com/?sku=1120000126&id=1
1EN
Operating manual – dehumidifier TTK 96 E / TTK 127 E
Safety
Carefully read this manual before starting / using the
device and keep it within reach.
•Do not use the device in potentially explosive rooms.
•Do not use the device in aggressive atmosphere.
•Set the device up in an upright and stable position.
•Ensure that the air inlet and outlet are not obstructed.
•Ensure that the side of the device where the air inlet is
found is kept free of dirt and loose objects.
•Never reach or put objects into the device.
•Do not cover or transport the device during operation.
•Do not use the device with wet or damp hands.
•Ensure that all electric cables outside of the device are
protected from damage (e.g. from animals). Never use the
device if the cable or power connection is damaged!
•Only use extensions to the connecting cable which are
appropriate to the device power consumption, the length of
its cable and its use. Completely unroll extension cables.
Avoid electrical overload.
•Only transport the device in an upright position with an
emptied condensation tank.
•Dispose of the collected condensate. Do not drink it. Health
hazard!
•Pull the plug from the socket if the device is not in use.
•Unplug the device from the mains before starting with
maintenance, service or repair work.
Intended use
Only use the device TTK 96 E / TTK 127 E for drying and
dehumidifying room air, while adhering to and following the
technical data.
Intended use comprises:
•drying and dehumidifying:
– living rooms, bedrooms or basements
– laundries, holiday homes.
•maintaining the dryness of:
– storage spaces, archives, laboratories, garages
– changing rooms etc.
Personnel qualifications
People who use this device must:
•be aware of the dangers that occur when working with
electric devices in damp areas.
•have read and understood the operating manual, especially
the Safety chapter.
Residual risks
Hazardous electric current!
Work on the electrical components must only be
carried out by an authorised specialist company!
Hazardous electric current!
Before any work on the device, remove the mains plug
from the mains socket!
Danger!
The device is not a toy and does not belong in the
hands of children.
Danger!
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Danger!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Caution!
To avoid damages to the device, do not operate the
device without an air filter inserted!
Behaviour in the event of an emergency
1. In an emergency, disconnect the device from the mains
feed-in: Switch the device off and disconnect it from the
mains.
2. Do not reconnect a defective device to the mains.
Improper use
Do not place the device TTK 96 E / TTK 127 E on wet or flooded
ground. Do not use the device outdoors. Do not place any
objects, e.g. wet clothing, on the device for drying.
Any unauthorised changes, modifications or alterations to the
device are forbidden.
EN2
Operating manual – dehumidifier TTK 96 E / TTK 127 E
Information about the device
1
2
3
11
10
9
8
7
4
12
6
5
Description of the device
The device TTK 96 E / TTK 127 E uses the principle of
condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as either condensation or rime. The
dehumidified, cooled air is slightly warmed and blown out again.
The drier air thus conditioned mixes with the air in the room.
The humidity in the room where the device is positioned is
reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
The device has a control panel for operating and controlling the
functions.
Once the maximum fill level of the condensation tank is
reached, the condensation tank indicator light (see chapter
Operating elements) on the control panel is illuminated. The
device switches off. The condensation tank indicator light only
goes out again once the emptied condensation tank is
reinserted.
Optionally, the condensed water can be drained by attaching a
hose (Ø = 14mm) at the condensation connection.
The device can reduce the relative humidity of a room to approx.
35%.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.
Device depiction
No.Designation
1Transport handle
2Air outlet
3Power cable holder
3EN
Operating manual – dehumidifier TTK 96 E / TTK 127 E
4Wheels
5Hose adapter for condensation drain hose
6Condensation drain hose
7Power cable
8Condensation hose connection with sealing cap
9Air inlet with air filter
10Filling level indication
11Condensation tank
12Control panel
Transport and storage
Transport
To make the device easier to transport, it is fitted with wheels.
Before transporting the device, proceed as follows:
1. Pump out any possibly remaining condensate. Check for
dripping condensation.
2. Pull the plug from the mains socket. Do not use the power
cable to drag the device.
3. Only wheel the device on a level and smooth surface.
Storage
Leave the device to rest for 24hours before storing it. Then
empty and clean the condensation tank, the filter and the device
prior to storing.
When the device is not being used, observe the following
storage conditions:
•Dry.
•In an upright and stable position.
•Protected from dust and direct sunlight.
•With a cover to protect it from invasive dust, if necessary.
3. Remove the power cable holder(3), the condensation drain
hose(6) and the hose adapter(5) from the condensation
tank.
1. Unpack the device and remove the cardboard box as well as
any other outer packaging.
2. Remove the condensation tank.
ð The holder should click into place.
6. Check the holder for tight fit.
ð If needed, you may now wind the power cable around the
holder.
EN4
Operating manual – dehumidifier TTK 96 E / TTK 127 E
Set-up and installation
On
Off
Full
Auto defrost
13 1417181920
212223242526
15 16
27
Operation
Positioning
When positioning the device, observe the minimum distance
from walls or other objects as described in chapter Technical
Data.
•Set the device up in a level and stable position.
•When positioning the device, keep a sufficient distance to
heat sources.
•When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.
•After being switched on, the device operates fully
automatically.
•The fan is running continuously until the device is switched
off.
•Avoid open doors and windows.
Operating elements
No.DesignationMeaning
13FILTER LEDIlluminated when the filter needs to be
cleaned.
14Auto defrost LEDIlluminated when the device carries out an
automatic defrost.
15CONT. LEDIlluminated when the device runs in
continuous operation.
16TURBO LEDIlluminated when the fan runs at maximum
power.
17FULL LEDIlluminated when the condensation tank is
full. See chapter Emptying the condensation
tank
18Off LEDIlluminated when the timer is programmed for
automatic switch-off.
19On LEDIlluminated when the timer is programmed for
automatic switch-on.
20DisplayIndicates the current humidity level.
Indicates the selected humidity value during
the humidity setting.
Indicates the number of hours during the
timer setting.
21POWER buttonSwitches the device on or off.
22Selection buttonSelection button for the humidity level (35%
to 85% in increments of 5%) or the timer
function (0 to 10h in increments of 0.5hours
or 10 to 24h in increments of 1h)
23TIMER buttonSwitches the timer function on or off.
24TURBO buttonSets the fan stage.
Stage 1 = normal
Stage 2 = function for drying laundry
25CONT. buttonSwitches continuous operation on or off.
26FILTER buttonResets the cleaning cycle for the filter.
27COMFORT buttonSwitches comfort mode on or off.
5EN
Operating manual – dehumidifier TTK 96 E / TTK 127 E
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.