Trotec TTK 95 E Operating Manual

Page 1
TTK 95 E
EN
OPERATING MANUAL
DEHUMIDIFIER
TRT-BA-TTK95E-TC-001-EN
Page 2

Table of contents

The current version of the operating manual can be found at:
Errors and faults..................................................................10
Maintenance ........................................................................12
Technical annex...................................................................15
Disposal ...............................................................................17

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
TTK 95 E
http://hub.trotec.com/?id=39477

Legal notice

This release replaces all previous versions. No part of this publication may be reproduced without written permission from TrotecGmbH&Co.KG. The same applies for electronically processing, duplicating or spreading the publication. Subject to technical changes. All rights reserved. Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer. Product names are registered.
Changes to construction in the interests of constant improvements to the product, as well as changes to the shape and colour are reserved.
The scope of delivery may vary from product images. This document was created with all due care. TrotecGmbH&Co.KG accepts no liability whatsoever for possible mistakes or omissions.
© TrotecGmbH&Co.KG
Warning!
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution!
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
1 EN
Operating manual – dehumidifier TTK 95 E
Page 3

Warranty and liability

The device complies with the fundamental health and safety requirements of the applicable EU regulations and was tested at the factory for perfect functionality multiple times.
However, if faults in the functionality occur and cannot be remedied with the measures in the chapter Errors and faults, please get in touch with your dealer or distributor.
When making a warranty claim, supply the device number (see the rear of the device).
When manufacturer's instructions or legal regulations have not been followed, or after unauthorised changes to the device are made, the manufacturer is not responsible for the resulting damages. Changes to the device or unauthorised replacement of individual parts can drastically impact the electrical safety of this product and will result in the loss of the warranty. Liability does not extend to damages to people or property caused by the device being used other than as described in the instructions in this operating manual. Subject to changes to technical design and model changes as part of constant development and product improvement without prior notice.
No liability is accepted for damages resulting from improper use. In such a case, any warranty claims will be voided also.

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Let the device dry out after a wet clean. Do not operate it when wet.
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
Do not sit on the device.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. Defective power cables pose a serious health risk.
Observe the storage and operating conditions (see chapter Technical data).
Ensure that the air inlet and outlet are not obstructed.
Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects.
Only transport the device in an upright position with an emptied condensation tank or drain hose.
Discharge the collected condensate before transport and storage. Do not drink it. Health hazard!
EN 2
Operating manual – dehumidifier TTK 95 E
Page 4

Intended use

Only use the device for drying and dehumidifying room air, while adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry.
Intended use comprises:
dehumidifying and drying:
– living rooms, bedrooms, bathrooms and basements – laundries, holiday homes, camper vans, boats
maintaining the dryness of:
– storage spaces, archives, laboratories, garages – bathrooms, wash rooms, changing rooms etc.

Improper use

Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, alterations or structural changes to the device are forbidden.
Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the operating manual, especially the Safety chapter.
Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning!
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning!
The device is not a toy and does not belong in the hands of children.
Warning!
Do not leave the packaging lying around. Children may use it as a dangerous toy.
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

Behaviour in the event of an emergency

1. In an emergency, disconnect the device from the mains feed-in: Switch the device off and disconnect the power cable from the mains socket. Hold onto the mains plug while doing so.
2. Do not reconnect a defective device to the mains.
3 EN
Operating manual – dehumidifier TTK 95 E
Page 5

Information about the device

1
2
3
4
5
6
7
8
9

Device description

The device uses the principle of condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter, the evaporator and to the condenser located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime. The dehumidified, cooled air is slightly warmed at the condenser and blown out again. The drier air thus conditioned mixes with the air in the room. The humidity in the room where the device is positioned is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the condensed water either drops continuously or only during the defrost phase through the integrated drain nozzle into the condensation tank below. It is fitted with a float to measure the filling level.
The device has a control panel for operating and controlling the functions.
Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not installed correctly, the condensation tank indicator light (see chapter Operating elements) on the control panel is illuminated. The device switches off. The condensation tank indicator light only goes out again once the emptied condensation tank is reinserted.
Optionally, the condensed water can be drained by attaching a hose at the condensation connection.
The device can reduce the relative humidity of a room to approx. 30 %.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the room temperature may rise slightly.

Device depiction

EN 4
Operating manual – dehumidifier TTK 95 E
No. Designation
1 Control panel
2 Condensation tank with filling level indicator
3 Air inlet with air filter
4 Condensation drain hose connection
5 Power cable winder
6 Air filter
7 Wheels
8 Transport handle
9 Air outlet
Page 6

Transport and storage

A
B
C
C
D

Assembly and installation

Transport

Before transporting the device, proceed as follows:
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
To make the device easier to transport, it is fitted with wheels.
Do not use the power cable to drag the device.
Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
Set up the device in an upright position after transport.
Leave the device to rest for 12-24hours, so the refrigerant can accumulate within the compressor. Wait 12-24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.

Storage

Before storing the device, proceed as follows:
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
Empty and clean the condensation tank prior to storage.
When the device is not being used, observe the following storage conditions:
dry and protected from frost and heat
in an upright position where it is protected from dust and direct sunlight
with a cover to protect it from invasive dust if necessary
Place no further devices or objects on top of the device to prevent it from being damaged.

Scope of delivery

Device
Air filter
Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.

Start-up

When positioning the device, observe the minimum distance from walls or other objects as described in chapter Technical Data.
5 EN
Operating manual – dehumidifier TTK 95 E
Page 7
Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service.
Set the device up in an upright and stable position.
Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges.
Make sure that extension cables are completely unrolled.
When positioning the device, keep a sufficient distance to heat sources.
Make sure that no curtains or other objects interfere with the air flow.
When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations.
Inserting the air filter
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
Inserting the condensation tank
Ensure that the float inside the condensation tank is inserted correctly.
Ensure that the condensation tank is empty and inserted correctly.
Connecting the power cable
Insert the mains plug into a properly secured mains socket.
Make sure that the air filter is installed before switching the device on.
EN 6
Operating manual – dehumidifier TTK 95 E
Page 8

Operation

111012 13 14
1923
15 16 17 18
202122
Avoid open doors and windows.
After being switched on, the device operates fully automatically.
The fan permanently runs in dehumidification mode even after the set nominal value has been reached until the device is switched off.
Operating elements
No. Designation Meaning
10 Swing function button Switches the automatic movement of the
ventilation flap on or off
11 Increase value button Setting the desired relative room humidity
Setting the number of hours for the timer function
12 Current room humidity
indication
13 Room humidity segment
display
14 Defrost indication Is displayed when automatic defrosting is
15 Fan speed indication Indication of the fan speed:
16 Swing function indication Is displayed when the swing function is
17 Ventilation button Setting the fan speed:
Indicates that the current relative room humidity is being displayed Disappears when the desired relative room humidity is being set
Indicates the current relative room humidity Indicates the desired relative room humidity during setting
in progress
= low
= high (laundry drying function)
activated
= low
= high (laundry drying function)
18 Power button Power button:
Switches the device on or off
19 Timer button Starts programming for the timer function
20 Condensation tank full
indication
21 Timer indication Is displayed when the timer is activated
22 Desired room humidity
indication
23 Decrease value button Setting the desired relative room humidity
Is displayed when the condensation tank is full or not installed correctly
Indicates the number or hours set ON = automatic switch-on enabled OFF = automatic switch-off enabled
Is displayed while the desired relative room humidity is being set
Setting the number of hours for the timer function
7 EN
Operating manual – dehumidifier TTK 95 E
Page 9
Switching the device on
Once you have completely installed the device as described in the Start-up chapter, you can switch it on.
1. Press the power button(18).
ð The unit starts to dehumidify.
Setting the operating mode
Setting the desired relative room humidity
You can change the desired relative room humidity at any time.
1. Press the increase value (11) or decrease value button(23) to set the desired relative room humidity. Setting is possible in the range between 30 % and 90 % in steps of 5 %.
ð The desired relative room humidity is shown on the room
humidity indication(13) for approx.5seconds. Then the
current relative room humidity is displayed again.
Setting the fan speed
You can choose between low and high fan speed (laundry drying function) at any time.
1. Press the fan button(17) to select either low or high fan speed (laundry drying function).
ð The selected fan speed is indicated on the fan speed
indication(15).
Dehumidification
The device keeps running until reaching the desired relative room humidity. Then the compressor switches off and the fan keeps running. Once the desired relative room humidity is exceeded, the compressor switches back on.
The desired relative room humidity can be set within a setting range from 30 % to 90 % in steps of 5 % at any time.
You can choose between low and high fan speed (laundry drying function).
Setting the timer
The timer has two modes of operation:
automatic switch-on upon expiry of a preset number of hours.
automatic switch-off upon expiry of a preset number of hours.
The number of hours can be between 1 and 24 and can be adjusted in increments of 1h.
Note
Do not leave the operating device unattended in a freely accessible room with an activated timer.
Automatic switch-on
1. Switch off the device.
2. Press the timer button(19).
ð The number of hours flashes on the timer
indication(21).
3. Press the increase value (11) or decrease value button(23) to set the desired number of hours.
4. Wait for approx. 5seconds in order to save the setting.
ð The characters ON and the number of hours left until
switch-on appear on the timer indication(21).
ð The timer setting equals the desired number of hours. ð The device starts after the set time has passed.
Note regarding automatic switch-on:
Pressing the power button(18) deactivates the automatic switch-on function.
Automatic switch-off
ü The device is switched on.
1. Press the timer button(19).
ð The number of hours flashes on the timer
indication(21).
2. Press the increase value (11) or decrease value button(23) to set the desired number of hours.
3. Wait for approx. 5seconds in order to save the setting.
ð The characters OFF and the number of hours left until
switch-off appear on the timer indication(21).
ð The timer setting equals the desired number of hours. ð The device switches off after the set period of time.
Auto stop function
If the water tank is full, not inserted correctly or the desired relative room humidity has been reached, the device will stop automatically.
Swing function
Using the swing function, you can activate continuous movement of the ventilation flap. This enables an even distribution of the air current in the room.
1. Press the swing function button(10).
ð The ventilation flap moves up and down continuously.
2. Press the swing function button(10) again to deactivate the swing function. The ventilation flap opens completely.
EN 8
Operating manual – dehumidifier TTK 95 E
Page 10
Operation with hose attached to the condensation connection
For continuous operation or unattended dehumidification, please connect a suitable condensation drain hose to the device.
ü A suitable hose (diameter: 13mm) is ready for use. ü The device is switched off.
1. Remove the sealing cap from the hose connection.
2. Remove the rubber plug.
4. Guide the other hose end to a suitable drain or sufficiently dimensioned collection container. Please observe that the hose must not be kinked.
3. Push one end of the hose onto the hose connection.
Remove the hose if you want to collect the condensate in the condensation tank again. Allow the hose to dry prior to storage. The hose can be connected in any operating mode for continuous operation.
9 EN
Operating manual – dehumidifier TTK 95 E
Page 11
Automatic defrost
At low ambient temperatures (below 12°C), ice may form at the evaporator during dehumidification. The device will then carry out an automatic defrost. Dehumidification is briefly interrupted during defrosting.
Info
We do not recommend operating the device at temperatures below 5°C.
The duration of the defrost process can vary. Do not switch off the device during automatic defrost. Do not remove the mains plug from the mains socket.
The defrost indication(14) is illuminated during automatic defrosting.
Drying laundry
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe the minimum distances specified in the technical data.
For drying laundry the following values should be selected:
cupboard dry = 46 % relative humidity
iron dry = 58 % relative humidity
slightly dried = 65 % relative humidity
If necessary, use a measuring device to determine the humidity level.
1. Select the highest fan speed by use of fan button(17).
ð The function for drying laundry is activated.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
If necessary, remove the condensation drain hose and any residual fluid from it.
Empty the condensation tank, if need be.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Check the filling level of the condensation tank and empty it if necessary. The condensation tank full indication(20) must not light up.
Check the condensation tank for correct seating.
Wait for 10minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec.
The device is running, but no condensate forms:
Check the float in the condensation tank for dirt. If necessary, clean the condensation tank. The float must be able to move freely.
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Ensure that the relative room humidity complies with the technical data.
Check the preselected desired room humidity level. The relative humidity in the room must be above the selected range. If necessary, reduce the preselected desired room humidity.
Check the air filter for dirt. If necessary, clean or replace the air filter.
From the outside, check the condenser for dirt (see chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
EN 10
Operating manual – dehumidifier TTK 95 E
Page 12
The device is loud or vibrates:
Check whether the device is set up in a stable and upright position.
Condensate is leaking:
Check the device for leaks.
The compressor does not start:
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Ensure that the relative room humidity complies with the technical data.
Check the preselected desired room humidity level. The relative humidity in the room must be above the selected range. If necessary, reduce the preselected desired room humidity.
Check whether the overheating protection of the compressor has tripped. Disconnect the device from the mains and let it cool down for approx. 10minutes before reconnecting it.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or loses power:
Check the air inlets and air filter for dirt. Remove external dirt.
From the outside, check the device for dirt (see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company for cooling and air-conditioning or by Trotec.
Note
Wait for at least 3 minutes after maintenance and repair work. Only then switch the device back on.
Your device still does not operate correctly after these checks?
Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair.
11 EN
Operating manual – dehumidifier TTK 95 E
Page 13

Maintenance

Maintenance intervals

Maintenance and care interval before every
start-up
Empty condensation tank and drain hose X
Check the air inlets and outlets for dirt and foreign objects and clean if necessary
Clean the exterior X X
Visually check the inside of the device for dirt
Check the air filter for dirt and foreign objects and clean or replace if necessary
Replace air filter X
Check for damage X
Check the attachment screws X X
Test run X
X X
X X
as needed at least every
2 weeks
X X
at least every 4 weeks
at least every 6 months
at least annually

Maintenance and care log

Device type: .............................................
Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Empty condensation tank and drain hose
Check the air inlets and outlets for dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and foreign objects and clean or replace if necessary
Replace air filter
Check for damage
Check the attachment screws
Test run
Remarks:
Device number: ....................................
1. Date: ................................
Signature: ............................
5. Date: ................................
Signature: ............................
9. Date: ................................
Signature: ............................
13. Date: ..............................
Signature: ............................
EN 12
2. Date: ................................
Signature: ............................
6. Date: ................................
Signature: ............................
10. Date: ..............................
Signature: ............................
14. Date: ..............................
Signature: ............................
Operating manual – dehumidifier TTK 95 E
3. Date: ................................
Signature: ............................
7. Date: ................................
Signature: ............................
11. Date: ..............................
Signature: ............................
15. Date: ..............................
Signature: ............................
4. Date: ................................
Signature: ............................
8. Date: ................................
Signature: ............................
12. Date: ..............................
Signature: ............................
16. Date: ..............................
Signature: ............................
Page 14

Activities required before starting maintenance

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.

Refrigerant circuit

The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air-conditioning or by Trotec.

Cleaning the air filter

Warning of electrical voltage
Maintenance tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec.

Cleaning the housing

Clean the device with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air-conditioning or by Trotec.
5. Put the air filter back in.
Note
Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be deformed or rounded. Before reinserting the air filter, make sure that it is undamaged and dry!
The air filter has to be cleaned as soon as it is dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults).
1. Remove the air filter from the device.
2. Clean the filter using a slightly damp, soft, lint-free cloth. If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent.
13 EN
Operating manual – dehumidifier TTK 95 E
Page 15
3. Allow the filter to dry completely. Do not insert a wet filter into the device!
4. Reinsert the air filter into the device.
In doing so, make sure that the float is positioned correctly. Also make sure that the condensation tank is inserted correctly, otherwise the device cannot be switched back on.

Emptying the condensation tank

If the condensation tank is full or not installed correctly, the condensation tank full indication(20) will light up on the control panel. The compressor and fan will switch off. An acoustic signal will sound for 5seconds.
1. Take the condensation tank out of the device.

Activities required after maintenance

If you want to continue using the device:
Leave the device to rest for 12-24hours, so the refrigerant can accumulate within the compressor. Wait 12-24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
Store the device according to the Storage chapter.
2. Empty the condensation tank over a drain or sink.
3. Rinse the tank with clear water. Clean the tank regularly using a mild cleaning agent (no detergent!).
4. Refit the condensation tank into the device. Make sure not to damage the float when inserting or removing the condensation tank.
EN 14
Operating manual – dehumidifier TTK 95 E
Page 16

Technical annex

SCHEMATICWIRINGDIAGRAM
N
(
/
1
<(
/
/2:
*5((1
%52:1
&2035(6625
2/3
%/$&.
5('
5('
<(//2:
7$/9
%/8(
%/
8
(
%
/8
(
&$3$&,725
)86(
&$3$&,725
%/8(
%/
$
&.
:+,7(
:+,7(
+,
/2
&1
&1&1&1
&1
&21752/%2$5'
&2
0
7VHQVRU
$&&25'
+VHQVRU
12
N N
N
67(33,1*
02725
)$1
02725
0,&52
6:,7&+

Technical data

Parameter Value
Model TTK95E
Max. dehumidification performance 30 l / 24 h
Dehumidification performance @ 30°C and 80% RH
Air volume flow 200 m3/h
Ambient temperature 5°C to 32°C
Operating range relative humidity 30 % to 80 % RH
Mains connection 1/N/PE ~ 230 V/ 50 Hz
Power input 0.6 kW
Nominal current 2.6 A
Refrigerant R134a
Amount of refrigerant 215 g
Condensation tank capacity 5.3 l
Sound pressure level (1m distance) 47 dB(A)
Dimensions (length x width x height) 240 x 368 x 560 (mm)
Minimum distance to walls and other objects
D: front:
Weight 16 kg
A: top: B: rear: C: side:
28 l / 24 h
20 cm 20 cm 20 cm 20 cm
Wiring diagram
15 EN
Operating manual – dehumidifier TTK 95 E
Page 17

Spare parts drawing and list




























47












Info
The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual.
EN 16
Operating manual – dehumidifier TTK 95 E
Page 18
No. Spare part No. Spare part No. Spare part
1 BASE PAN 18 CAPACITOR(30uf/450V FOR COMPRESSOR (3)) 35 POWR WIRING BUCKLE
2 TURING WHEEL 19 FIX METAL 36 REAR PANEL
3 COMPRESSOR ASS'Y(35D042-B1) 20 GEAR 37 DRAIN BUCKET
4 RUBBER 21 STRIKE 38 DRAIN BUCKET
5 SUCTION PIPE 22 CAPILLARY TUBE 39 TANK LID
6 DISCHARGE PIPE 23 SENSOR 40 HANDLE
7 PLATE 24 FIX TUBE 41 VAN AIR DEFLEETOR
8 DRAINAGE PAN 25 CAPACITOR(1uF450V for motor(12)) 42 LNTAKE GRILLE
9 EVAPORATOR ASS'Y 26 ELECTRIC BOX 43 SOFT CAP
10 CONDENSER ASS'Y 27 PROTECT COVER 44 PLUG
11 FAN CASING BOX 28 CONTROL BOARD 45 SOFT CAP
12 FAN MOTOR(WF4-012D2-82D-NHAF) 29 PC BOARD 46 TOP COVER
13 BLOWER WHEEL 30 FIX METAL 47 HANDLE
14 FAN TANK 31 SENSOR (FOR EVAPORATOR ASS'Y(9)) 48 FIX TUBE
15 DISCHARGE GRILLE 32 POWER SUPPLY CORD COMPLETET ASS'Y 49 Y TUBE
16 MICRO SWITCH 33 DECORATIVE PLARES 50 OVER LOAD PROTECTOR(B90-135D-241A)
17 FIX TUBE 34 DECORATIVE PLARES

Disposal

In the European Union, electronic equipment must not be treated as domestic waste, but must be disposed of professionally in accordance with Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012 on waste electrical and electronic equipment (WEEE). At the end of its life, please dispose of this device according to the valid legal requirements.
The device uses an environmentally and ozone-neutral cooling agent (see Technical Data).
Dispose of the refrigerant appropriately and according to the national regulations.
17 EN
Operating manual – dehumidifier TTK 95 E
Page 19
Page 20
Trotec GmbH & Co. KG
Grebbener Str. 7 D-52525 Heinsberg