Trotec TTK 90 E Operating Manual

Page 1
TTK 90 E
EN
OPERATING MANUAL
DEHUMIDIFIER
TRT-BA-TTK90E-TC-004-EN
Page 2

Table of contents

You can download the current version of the operating manual and the EU declaration of conformity via the following link:

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Notice
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
TTK 90 E
https://hub.trotec.com/?id=41398

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Let the device dry out after a wet clean. Do not operate it when wet.
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
Do not sit on the device.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
1 EN
Operating manual – dehumidifier TTK 90 E
Page 3
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk.
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
Ensure that the air inlet and outlet are not obstructed.
Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects.
Only transport the device in an upright position with an emptied condensation tank or drain hose.
Discharge the collected condensate before transport and storage. Do not drink it. Health hazard!

Intended use

Only use the device for drying and dehumidifying room air, while adhering to and following the technical data.
Intended use comprises:
dehumidifying and drying:
– living rooms, bedrooms, bathrooms and basements – laundries, holiday homes, camper vans, boats
maintaining the dryness of:
– storage spaces, archives, laboratories, garages – bathrooms, wash rooms, changing rooms etc.

Improper use

Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, alterations or structural changes to the device are forbidden.
Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the operating manual, especially the Safety chapter.
Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.
EN 2
Operating manual – dehumidifier TTK 90 E
Page 4

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Notice
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

Behaviour in the event of an emergency

1. Switch the device off.
2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
3. Do not reconnect a defective device to the mains.

Information about the device

Description of the device

The device uses the principle of condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter, the evaporator and to the condenser located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime. The dehumidified, cooled air is slightly warmed at the condenser and blown out again. The drier air thus conditioned mixes with the air in the room. The humidity in the room where the device is positioned is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the condensed water either drops continuously or only during the defrost phase through the integrated drain nozzle into the condensation tank below. It is fitted with a float to measure the filling level.
The device has a control panel for operating and controlling the functions.
Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not installed correctly, the condensation tank indicator light (see chapter Operating elements) on the control panel is illuminated. The device switches off. The condensation tank indicator light only goes out again once the emptied condensation tank is reinserted.
Optionally, the condensed water can be drained by attaching a hose at the condensation connection.
The device can reduce the relative humidity of a room to approx. 30 %.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the room temperature may rise slightly.
3 EN
Operating manual – dehumidifier TTK 90 E
Page 5

Device depiction

1
2
6
7
8
5
3
4
No. Designation
1 Air outlet
2 Wheels
3 Condensation drain hose connection
4 Air filter
5 Transport handle
6 Condensation tank
7 Air inlet
8 Control panel
EN 4
Operating manual – dehumidifier TTK 90 E
Page 6

Transport and storage

A
B
C
C
D

Assembly and installation

Notice
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

To make the device easier to transport, it is fitted with wheels.
To make the device easier to transport, it is fitted with a carry handle.
Before transporting the device, observe the following:
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Do not use the power cable to drag the device.
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
Set up the device in an upright position after transport.
Leave the device to rest for 12to24hours, so the refrigerant can accumulate within the compressor. Wait 12to24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.

Scope of delivery

1x Device
1x Air filter
1x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.

Start-up

When positioning the device, observe the minimum distance from walls or other objects as described in the Technical data chapter.

Storage

Before storing the device, proceed as follows:
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
Empty and clean the condensation tank prior to storage.
Drain any possibly remaining condensate.
When the device is not being used, observe the following storage conditions:
dry and protected from frost and heat
in an upright position where it is protected from dust and direct sunlight
with a cover to protect it from invasive dust if necessary
Place no further devices or objects on top of the device to prevent it from being damaged.
5 EN
Operating manual – dehumidifier TTK 90 E
Page 7
Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service.
Set the device up in an upright and stable position.
Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges.
Make sure that extension cables are completely unrolled.
When positioning the device, keep a sufficient distance to heat sources.
Make sure that no curtains or other objects interfere with the air flow.
When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations.
Inserting the air filter
Notice
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
Make sure that the air filter is installed before switching the device on.
Inserting the condensation tank
Ensure that the float inside the condensation tank is inserted correctly.
Ensure that the condensation tank is empty and inserted correctly.
Connecting the power cable
Insert the mains plug into a properly secured mains socket.
EN 6
Operating manual – dehumidifier TTK 90 E
Page 8

Operation

9
10
11
12
13 14
15 16
1718
19
20
21
Avoid open doors and windows.
After being switched on, the device operates fully automatically.
The fan permanently runs in dehumidification mode even after the set nominal value has been reached until the device is switched off.
Operating elements
No. Designation Meaning
9 Condensation tank full
LED
10 Automatic defrost LED Illuminated during automatic
11 High fan speed LED Illuminated when a high fan
12 Low fan speed LED Illuminated when a low fan
13 Timer LED Illuminated when the timer is
14 Arrow button up Setting the relative humidity
15 Arrow button down
16 °C/°F button Setting the temperature unit
17 Humidity level segment
display
18 Temperature/hours
segment display
19 Timer button Switching the timer function on
Illuminated when the condensation tank is full or not installed correctly
defrosting
speed is set (function for drying laundry)
speed is set
programmed
level (30 to 90 %RH in increments of 5%)
(°C or °F)
Indicates the current relative room humidity Indicates the desired relative room humidity during setting
Indicates the current temperature in °C or in °F Indicates the number of hours during timer programming
or off Setting the number of hours for the timer (1 to 12h)
No. Designation Meaning
20 Fan speed button Setting a low or high fan speed
(function for drying laundry)
21 Power button Switching the device on or off
Switching the device on
Once you have completely installed the device as described in the Start-up chapter, you can switch it on.
1. Press the Power button(21).
ð The device will start up.
Setting the operating mode
Setting the desired relative room humidity
Setting is possible in the range between 30% and 90 % in increments of 5%.
1. Press the arrow buttons(14, 15) to adjust the relative room humidity.
ð The desired relative room humidity will be indicated on the
humidity level segment display(17).
Setting the fan speed
Using this function you can choose between a low and a high fan speed (function for drying laundry).
1. Press the fan speed button(20) to select either high or low fan speed.
ð The LED for high(11) or low(12) fan speed lights up
depending on the selected setting.
Dehumidification
The device keeps running until reaching the desired relative room humidity. Once the desired relative room humidity is exceeded, the compressor switches back on.
The desired relative room humidity can be set within a setting range from 30 % to 90 % in steps of 5% at any time.
Setting the timer
For the device to switch on or off automatically after a predefined number of hours (1 to 24h) you can programme the timer.
The timer can be programmed in increments of 1hour (1to 24h).
Notice
Do not leave the operating device unattended in a freely accessible room with an activated timer.
7 EN
Operating manual – dehumidifier TTK 90 E
Page 9
Automatic switch-on
1/2''
1. Switch off the device.
2. Press the timer button(19) to activate the timer.
ð The timer LED(13) is illuminated. ð The number of hours is shown on the segment
display(18).
3. Press the arrow buttons(14, 15) to set the number of hours.
ð The number of hours flashes on the segment
display(18).
4. Wait for approx. 5seconds in order to save the setting.
ð After the predefined time, the device switches itself on. ð The set operating time will be indicated for a few seconds
on the segment display(18). Afterwards, the current temperature is displayed again.
Note regarding automatic switch-on:
Pressing the power button(21) deactivates the automatic switch-on function.
Automatic switch-off
ü The device is switched on.
1. Press the timer button(19) to activate the timer.
ð The timer LED(13) is illuminated. ð The number of hours is shown on the segment
display(18).
2. Press the arrow buttons(14, 15) to set the number of hours.
ð The number of hours flashes on the segment
display(18).
ð After the predefined time, the device switches itself off. ð The set operating time will be indicated for a few seconds
on the segment display(18). Afterwards, the current temperature is displayed again.
Note regarding automatic switch-off:
Pressing the power button(21) deactivates the automatic switch-off function.
Operation with hose attached to the condensation connection
For continuous operation or unattended dehumidification, please connect the supplied condensation drain hose to the device.
ü A suitable hose (diameter= 1/2inch) is ready for use. ü The device is switched off.
1. Unscrew the cover from the condensation drain hose connection(3).
2. Remove the rubber plug.
3. Keep the cover and rubber stopper for later use.
4. Push one end of the hose onto the hose connection.
EN 8
Operating manual – dehumidifier TTK 90 E
Page 10
5. Guide the other hose end to a suitable drain or sufficiently dimensioned collection container. Please observe that the hose must not be kinked.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
If necessary, remove the condensation drain hose and any residual fluid from it.
Empty the condensation tank, if need be.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
Remove the hose if you want to collect the condensate in the condensation tank again. Allow the hose to dry prior to storage. The hose can be connected in any operating mode for continuous operation.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator during dehumidification. The device will then carry out an automatic defrost. Dehumidification is briefly interrupted during defrosting. The fan keeps running.
The automatic defrost LED(10) is illuminated throughout the defrost process.
The duration of the defrost process can vary. Do not switch the device off during automatic defrost. Do not remove the mains plug from the mains socket.
Drying laundry
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe the minimum distances specified in the technical data.
For drying laundry the following values should be selected:
cupboard dry = 46 % relative humidity
iron dry = 58 % relative humidity
slightly dried = 65 % relative humidity
If necessary, use a measuring device to determine the humidity level.
1. Press the fan speed button(20) to set the high fan speed.
ð The LED for high fan speed(11) will be illuminated. ð The function for drying laundry is activated.
9 EN
Operating manual – dehumidifier TTK 90 E
Page 11

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Check the condensation tank for correct seating.
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Wait for 10minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec.
The device is running, but there is no formation of condensate:
Check the float in the condensation tank for dirt. If necessary, clean the condensation tank. The float must be able to move freely.
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Ensure that the relative room humidity complies with the technical data.
Check the air filter for dirt. If necessary, clean or replace the air filter.
From the outside, check the condenser for dirt (see chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or loses power:
Check the air inlets and air filters for dirt. Remove external dirt.
From the outside, check the device for dirt (see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company for cooling and air­conditioning or by Trotec.
Notice
Wait for at least 3 minutes after maintenance and repair work. Only then switch the device back on.
Your device still does not operate correctly after these checks?
Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright position.
Condensate is leaking:
Check the device for leaks.
The compressor does not start:
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Ensure that the relative room humidity complies with the technical data.
Check whether the overheating protection of the compressor has tripped. Disconnect the device from the mains and let it cool down for approx. 10minutes before reconnecting it.
EN 10
Operating manual – dehumidifier TTK 90 E
Page 12

Maintenance

Maintenance intervals

Maintenance and care interval before every
start-up
Empty condensation tank and drain hose
Check the air inlets and outlets
X X
for dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and
X X
foreign objects and clean or replace if necessary
Replace air filter
Check for damage
X
Check the attachment screws
Test run
as needed at least every
2 weeks
X
X X
X X
X X
at least every 4 weeks
at least every 6 months
X
at least annually
X
11 EN
Operating manual – dehumidifier TTK 90 E
Page 13

Maintenance and care log

Device type: .............................................
Device number: ....................................
Maintenance and care interval
Empty condensation tank and drain hose
Check the air inlets and outlets for dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and foreign objects and clean or replace if necessary
Replace air filter
Check for damage
Check the attachment screws
Test run
Remarks:
1. Date: ................................
Signature: ............................
5. Date: ................................
Signature: ............................
9. Date: ................................
Signature: ............................
13. Date: ..............................
Signature: ............................
2. Date: ................................
Signature: ............................
6. Date: ................................
Signature: ............................
10. Date: ..............................
Signature: ............................
14. Date: ..............................
Signature: ............................
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
3. Date: ................................
Signature: ............................
7. Date: ................................
Signature: ............................
11. Date: ..............................
Signature: ............................
15. Date: ..............................
Signature: ............................
4. Date: ................................
Signature: ............................
8. Date: ................................
Signature: ............................
12. Date: ..............................
Signature: ............................
16. Date: ..............................
Signature: ............................
EN 12
Operating manual – dehumidifier TTK 90 E
Page 14

Activities required before starting maintenance

Cleaning the air filter

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air­conditioning or by Trotec.
5. Put the air filter back in.
Notice
Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be deformed or rounded. Before reinserting the air filter, make sure that it is undamaged and dry!
The air filter has to be cleaned as soon as it is dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults).
1. Take the condensation tank out of the device.
2. Remove the air filter.
3. Clean the filter using a slightly damp, soft, lint-free cloth. If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent.

Refrigerant circuit

The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air­conditioning or by Trotec.
4. Allow the filter to dry completely. Do not insert a wet filter into the device!
13 EN
Operating manual – dehumidifier TTK 90 E
Page 15
5. Put the air filter back in.
6. Refit the condensation tank into the device.

Emptying the condensation tank

If the condensation tank is full or not installed correctly, the condensation tank full LED(9) will be illuminated. The compressor and fan will switch off.
1. Take the condensation tank out of the device.
2. Empty the condensation tank over a drain or sink.
3. Rinse the condensation tank with clear water. Regularly clean the condensation tank using a mild cleaning agent (no detergent!).
4. Refit the condensation tank into the device. Make sure not to damage the float when inserting or removing the condensation tank. In doing so, make sure that the float is positioned correctly. In doing so, make sure that the condensation tank is inserted correctly, for otherwise the device cannot be switched back on.
EN 14
Operating manual – dehumidifier TTK 90 E
Page 16

Activities required after maintenance

If you want to continue using the device:
Leave the device to rest for 12to24hours, so the refrigerant can accumulate within the compressor. Wait 12to24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
Store the device according to the Storage chapter.

Technical annex

Technical data

Parameter Value
Model TTK90E
Max. dehumidification performance
Dehumidification performance at 30°C and 80% RH
Air volume flow 240 m3/h
Ambient temperature 5°C to 35°C
Operating range for relative humidity
Mains connection 230V/ 50Hz
Power consumption 520 W
Nominal current 2.3 A
Type and rating of fuse T3.15AL / 250V
Refrigerant R-410A
Amount of refrigerant 160 g
GWP factor 2088
CO2 equivalent 0.33 t
Condensation tank capacity 5.2 l
Sound pressure level 50 dB(A)
Dimensions (length x width x height)
Minimum distance to walls and other objects
B: rear: C: side:
D: front:
Weight 14 kg
30 l / 24 h
28.4 l / 24 h
30% to 100 %RH
253 x 340 x 540 (mm)
A: top:
50 cm 50 cm 50 cm 50 cm

Disposal

The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
The device is operated with fluorinated greenhouse gas which can be dangerous for the environment and contribute to global warming when emitted to the atmosphere.
Further information is provided on the nameplate.
Dispose of the refrigerant appropriately and according to the national regulations.
15 EN
Operating manual – dehumidifier TTK 90 E
Page 17
Page 18
Trotec GmbH & Co. KG
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400 +49 2452 962-200
info@trotec.com www.trotec.com
Loading...