Trotec TTK 53 E Operating Manual

Page 1
TTK 53 E / TTK 72 E
EN
OPERATING MANUAL
DEHUMIDIFIER
TRT-BA-TTK53E-TTK72E-TC2016-09-004-EN
Page 2

Table of contents

You can download the current version of the operating manual and the EU declaration of conformity via the following link:

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
TTK 53 E
https://hub.trotec.com/?id=42189
TTK 72 E
https://hub.trotec.com/?id=41804

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Let the device dry out after a wet clean. Do not operate it when wet.
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
Do not sit on the device.
2 EN
dehumidifier TTK 53 E / TTK 72 E
Page 3
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk!
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
Make sure that the air inlet and outlet are not obstructed.
Make sure that the suction side is kept free of dirt and loose objects.
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
Only transport the device in an upright position with an emptied condensation tank or drain hose.
Discharge the collected condensate before transport and storage. Do not drink it. Health hazard!

Intended use

Only use the device for drying and dehumidifying room air, while adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry.
Intended use comprises:
dehumidifying and drying:
– living rooms, bedrooms, bathrooms and basements – laundries, holiday homes, camper vans, boats
maintaining the dryness of:
– storage spaces, archives, laboratories, garages – bathrooms, wash rooms, changing rooms etc.

Improper use

The device is not intended for industrial use.
Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, alterations or structural changes to the device are forbidden.
Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the operating manual, especially the Safety chapter.
Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.
EN 3
dehumidifier TTK 53 E / TTK 72 E
Page 4

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

Behaviour in the event of an emergency

1. Switch off the device.
2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
3. Do not reconnect a defective device to the mains.

Information about the device

Description of the device

The device uses the principle of condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter, the evaporator and to the condenser located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime. The dehumidified, cooled air is slightly warmed at the condenser and blown out again. The drier air thus conditioned mixes with the air in the room. The humidity in the room where the device is positioned is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the condensed water either drops continuously or only during the defrost phase through the integrated drain nozzle into the condensation tank below. It is fitted with a float to measure the filling level.
The device has a control panel for operating and controlling the functions.
Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not installed correctly, the condensation tank indicator light (see chapter Operating elements) on the control panel is illuminated. The device switches off. The condensation tank indicator light only goes out again once the emptied condensation tank is reinserted.
Optionally, the condensed water can be drained by attaching a hose at the condensation connection.
The device can reduce the relative humidity of a room to approx. 30%.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the room temperature may rise slightly.
4 EN
dehumidifier TTK 53 E / TTK 72 E
Page 5

Device depiction

1
2
3
4
5
6
7
8
9
2
3
10
No. Designation
1 Control panel
2 Transport handle
3 Wheels
4 Air inlet with air filter
5 Condensation drain hose connection
6 Condensation tank
7 Air filter
8 Condensation drain hose
9 Air outlet
10 Colour LED for current room humidity
EN 5
dehumidifier TTK 53 E / TTK 72 E
Page 6

Transport and storage

A
B
C
C
D

Assembly and installation

Note
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

To make the device easier to transport, it is fitted with wheels.
Before transporting the device, observe the following:
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Do not use the power cable to drag the device.
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
Set up the device in an upright position after transport.
Leave the device to rest for 12to24hours, so the refrigerant can accumulate within the compressor. Wait 12to24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.

Scope of delivery

1x Device
1x Condensation drain hose, length: 0.3 m, diameter: 10 mm
1x Air filter
1x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.

Start-up

When positioning the device, observe the minimum distance from walls or other objects as described in the Technical data chapter.

Storage

Before storing the device, proceed as follows:
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
Empty and clean the condensation tank prior to storage.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Drain any possibly remaining condensate.
When the device is not being used, observe the following storage conditions:
dry and protected from frost and heat
in an upright position where it is protected from dust and direct sunlight
with a cover to protect it from invasive dust if necessary
Place no further devices or objects on top of the device to prevent it from being damaged.
Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service.
Set the device up in an upright and stable position.
Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges.
Make sure that extension cables are completely unrolled.
6 EN
dehumidifier TTK 53 E / TTK 72 E
Page 7
When positioning the device, keep a sufficient distance to heat sources.
Make sure that no curtains or other objects interfere with the air flow.
When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations.
Inserting the air filter
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
Make sure that the air filter is installed before switching the device on.
Inserting the condensation tank
Ensure that the float inside the condensation tank is inserted correctly.
Ensure that the condensation tank is empty and inserted correctly.
Connecting the power cable
Insert the mains plug into a properly secured mains socket.
EN 7
dehumidifier TTK 53 E / TTK 72 E
Page 8

Operation

12 13 14 16 17
24 23 22 21 20
15
18
11
19
Notes:
Avoid open doors and windows.
After being switched on, the device operates fully automatically.
The fan permanently runs in dehumidification mode until the set nominal value is reached. The fan keeps running for approx. 3minutes and then switches off.
Operating elements
No. Designation Meaning
11 TIMER button Starts programming for the timer
function
12 Plus arrow button Setting the relative room humidity
Setting the number of hours for the timer function
13 Segment display Indicates the relative room
humidity level Indicates the desired relative room humidity during setting Indicates continuous operation CO in dehumidification mode Indicates the number of hours during timer programming
14 Minus arrow button Setting the relative room humidity
Setting the number of hours for the timer function
15 Operating modes
indication
Indication of active operating mode: Automatic = Automatic mode Continuous = Dehumidification (additionally continuous operation) Dry Clothes = Laundry drying
function Air Clean = Ventilation
No. Designation Meaning
16 MODE button Selection button for operating
modes:
Automatic mode Dehumidification (additionally
continuous operation)
Laundry drying function Ventilation
17 STAND-BY button Power button:
Switches the device on or off
18 OPERATION indication Illuminated when the device is
switched on
19 AUTOMATIC indication Automatic mode is active
20 CONTINUOUS indication Dehumidification mode is active
Continuous operation is active
21 DRY CLOTHES
Laundry drying mode is active
indication
22 AIR CLEAN indication Ventilation mode is active
23 TANK FULL indication Illuminated when the
condensation tank is full
24 TIMER indication Illuminated when the timer is
programmed
Switching the device on
Once you have completely installed the device as described in the Start-up chapter, you can switch it on.
1. Press the STAND-BY button(17).
ð The device starts in automatic mode.
Setting the operating mode
Setting the relative room humidity
You can only change the relative room humidity in dehumidification mode.
1. Press the arrow buttons(12, 14) to adjust the relative room humidity. Setting is possible in the range between 30% and 80% in increments of 5%.
ð The desired relative room humidity is indicated in the
segment display(13) for approx.5seconds. Then the current relative room humidity is displayed again.
8 EN
dehumidifier TTK 53 E / TTK 72 E
Page 9
Dehumidification
The device keeps running until reaching the preselected relative room humidity. Then the compressor switches off and the fan keeps running and switches off with a delay. Once the preselected relative room humidity is exceeded, the compressor and ventilation switch back on.
The relative room humidity can be preselected in this operating mode. Setting is possible in the range between 30% and 80% in increments of 5%.
The fan runs at low speed and the fan speed cannot be changed.
1. Press the MODE button(16).
ð The indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the CONTINUOUS indication(20) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ð Dehumidification mode is selected. ð The CONTINUOUSindication (20) is illuminated.
4. Press the arrow buttons(12, 14) to adjust the relative room humidity.
5. Wait for approx. 5seconds in order to save the setting.
Automatic mode
The relative room humidity is preset to 55 % and cannot be changed.
If the relative room humidity lies between 55 % and 70 %, the fan automatically switches over to low speed.
Below a relative room humidity of 55%, the compressor switches off.
Above a relative room humidity of 70 %, the fan runs at the highest level.
1. Press the MODE button(16).
ð The indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the AUTOMATIC indication(19) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ð Automatic mode is selected. ð The AUTOMATICindication (19) is illuminated.
Laundry drying function
The device may be used to dry clothes in a more timely manner. When positioning the device or a clothes horse, please observe the minimum distances specified in the technical data.
The device dehumidifies the air constantly and regardless of the relative room humidity. The fan runs at the highest speed.
The relative room humidity and the fan speed cannot be set in this operating mode.
1. Press the MODE button(16).
ð The indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the DRY CLOTHES indication(21) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ð The laundry drying function is selected. ð The DRY CLOTHESindication (21) is illuminated.
Ventilation
The fan runs at low speed. The compressor does not run.
1. Press the MODE button(16).
ð The indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the AIR CLEAN indication(22) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ð Ventilation mode is selected. ð The AIR CLEANindication (22) is illuminated.
Continuous operation
The device dehumidifies the air constantly and regardless of the relative room humidity.
The fan runs at low speed and the fan speed cannot be changed.
1. Press the MODE button(16).
ð The indication of the currently selected operating mode
flashes.
2. Press the MODE button(16) until the CONTINUOUS indication(20) flashes.
3. Wait for approx. 5seconds in order to save the setting.
ð The CONTINUOUSindication (20) is illuminated.
4. Press the arrow buttons(12, 14) until CO is indicated in the segment display(13).
5. Wait for approx. 5seconds in order to save the setting.
ð Continuous operation(20) is selected.
EN 9
dehumidifier TTK 53 E / TTK 72 E
Page 10
Colour LED for current room humidity
Regardless of the operating mode, the colour LED indicates the current relative room humidity by means of 3 different colours.
LED colour Meaning
Blue
Green
Relative room humidity below 55%
Optimal relative room humidity between 55% and 70%
Red
Illuminated: relative room humidity above 70% Flashes: water tank full or not inserted correctly (accompanied by an acoustic signal)
Setting the timer
Using the timer function, the device can be switched off automatically after a preset number of hours.
The number of hours can range from 1 to 24 and can be adjusted in increments of 1h.
Note
Do not leave the operating device unattended in a freely accessible room with an activated timer.
Operation with hose attached to the condensation connection
For continuous operation or unattended dehumidification, please connect the supplied condensation drain hose to the device.
ü A suitable hose (diameter: 10mm) is ready for use. ü The device is switched off.
1. Take the condensation tank out of the device.
Automatic switch-off
ü The device is switched on.
1. Press the TIMER button(11).
ð The segment display(13) flashes.
2. Press the arrow buttons(12, 14) to set the desired number of hours.
3. Wait for approx. 5seconds in order to save the setting.
ð The TIMERindication (24) is illuminated. ð The relative room humidity is indicated in the segment
display(13) again.
ð The device switches off after the set period of time.
Memory function
The device memorizes the last selected operating mode, and in dehumidification mode(20) also the set room humidity during short power failures. If the timer was programmed, this setting will not be saved.
If the device was disconnected from the mains for a longer time, the device starts in automatic mode when it is switched back on.
Auto stop function
If the water tank is full, not inserted correctly or the relative room humidity has been reached, the compressor will stop automatically. The fan keeps running and then switches off.
2. Push one end of the hose onto the hose connection.
10 EN
dehumidifier TTK 53 E / TTK 72 E
Page 11
3. Refit the condensation tank into the device. In doing so, make sure that the condensation tank is inserted correctly, for otherwise the device cannot be switched back on.
4. Guide the other hose end to a suitable drain or sufficiently dimensioned collection container. Please note that the hose must not be kinked.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator during dehumidification. The device will then carry out an automatic defrost. Dehumidification is briefly interrupted during defrosting.
The duration of the defrost process can vary. Do not switch off the device during automatic defrost. Do not remove the mains plug from the mains socket.
Drying laundry
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe the minimum distances specified in the technical data.
For drying laundry the following values should be selected:
cupboard dry = 46 % relative humidity
iron dry = 58 % relative humidity
slightly dried = 65 % relative humidity
If necessary, use a measuring device to determine the humidity level.
Shutdown
Remove the hose if you want to collect the condensate in the condensation tank again. Allow the hose to dry prior to storage. The hose can be connected in any operating mode for continuous operation.
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
If necessary, remove the condensation drain hose and any residual fluid from it.
Empty the condensation tank, if need be.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
EN 11
dehumidifier TTK 53 E / TTK 72 E
Page 12

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Check the filling level of the condensation tank and empty it if necessary. The Tank Full indication(23) must not light up.
Check the condensation tank for correct seating.
Check the room temperature. Observe the device's permissible operating range according to the technical data. Possibly, the device does not start because the ambient temperature is too low (< 5°C).
Wait for 10minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec.
The device is running, but there is no formation of condensate:
Check the float in the condensation tank for dirt. If necessary, clean the condensation tank. The float must be able to move freely.
Check the room temperature. Observe the device's permissible operating range according to the technical data. Possibly, the device does not start because the ambient temperature is too low (< 5°C).
Ensure that the relative room humidity complies with the technical data.
Check the preselected relative room humidity. The humidity in the room must be above the selected range.
Check the air filter for dirt. If necessary, clean or replace the air filter.
From the outside, check the condenser for dirt (see chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
The compressor does not start:
Check the room temperature. Observe the device's permissible operating range according to the technical data. Possibly, the device does not start because the ambient temperature is too low (< 5°C).
Ensure that the relative room humidity complies with the technical data.
Check the preselected relative room humidity. The humidity in the room must be above the selected range.
Check whether the overheating protection of the compressor has tripped. Disconnect the device from the mains and let it cool down for approx. 10minutes before reconnecting it.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or loses power:
Check the air inlets and air filters for dirt. Remove external dirt.
From the outside, check the device for dirt (see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company for cooling and air­conditioning or by Trotec.
Note
Wait for at least 3 minutes after maintenance and repair work. Only then switch the device back on.
Your device still does not operate correctly after these checks?
Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright position.
Condensate is leaking:
Check the device for leaks.
12 EN
dehumidifier TTK 53 E / TTK 72 E
Page 13

Maintenance

Maintenance intervals

Maintenance and care interval before every
start-up
Check air inlets and outlets for
X X
dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and
X X
foreign objects and clean or replace if necessary
Replace the air filter
Check for damage
X
Check the attachment screws
Test run
Empty the condensation tank and drain hose
as needed at least every
2weeks
X X
X X
X X
X
at least every 4weeks
at least every 6months
X
at least annually
X
EN 13
dehumidifier TTK 53 E / TTK 72 E
Page 14

Maintenance and care log

Device type: .............................................
Device number: ....................................
Maintenance and care interval
Check air inlets and outlets for dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and foreign objects and clean or replace if necessary
Replace the air filter
Check for damage
Check the attachment screws
Test run
Empty the condensation tank and drain hose
Comments
1. Date: ...................................
Signature: ................................
5. Date: ...................................
Signature: ................................
9. Date: ...................................
Signature: ................................
13. Date: .................................
Signature: ................................
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
2. Date: ....................................
Signature: .................................
6. Date: ....................................
Signature: .................................
10. Date: ..................................
Signature: .................................
14. Date: ..................................
Signature: .................................
3. Date: ....................................
Signature: .................................
7. Date: ....................................
Signature: .................................
11. Date: ..................................
Signature: .................................
15. Date: ..................................
Signature: .................................
4. Date: ....................................
Signature: .................................
8. Date: ....................................
Signature: .................................
12. Date: ..................................
Signature: .................................
16. Date: ..................................
Signature: .................................
14 EN
dehumidifier TTK 53 E / TTK 72 E
Page 15

Activities required before starting maintenance

Cleaning the air filter

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air­conditioning or by Trotec.
5. Put the air filter back in.
Note
Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be deformed or rounded. Before reinserting the air filter, make sure that it is undamaged and dry!
The air filter has to be cleaned as soon as it is dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults).
1. Remove the air filter from the device.
2. Clean the filter using a slightly damp, soft, lint-free cloth. If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent.
3. Allow the filter to dry completely. Do not insert a wet filter into the device!

Refrigerant circuit

The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air­conditioning or by Trotec.
EN 15
dehumidifier TTK 53 E / TTK 72 E
Page 16
4. Reinsert the air filter into the device.
2. Empty the condensation tank over a drain or sink.
3. Rinse the tank with clear water. Clean the tank regularly using a mild cleaning agent (no detergent!).
4. Refit the condensation tank into the device. Make sure not to damage the float when inserting or removing the condensation tank. In doing so, make sure that the float is positioned correctly. In doing so, make sure that the condensation tank is inserted correctly, for otherwise the device cannot be switched back on.

Emptying the condensation tank

If the condensation tank is full or not inserted correctly, an acoustic signal will be emitted. Furthermore, the colour LED for the current room humidity(10) flashes red and the TANK FULL indication(23) is illuminated. The compressor and fan will switch off.
1. Take the condensation tank out of the device.

Activities required after maintenance

If you want to continue using the device:
Leave the device to rest for 12to24hours, so the refrigerant can accumulate within the compressor. Wait 12to24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
Store the device according to the Storage chapter.
16 EN
dehumidifier TTK 53 E / TTK 72 E
Page 17

Technical annex

Technical data

Parameter Value
Model TTK53E TTK 72 E
Dehumidifying capacity max. 16 l / 24 h 24 l / 24 h
Air volume 195 m3/h 195 m3/h
Operating range (temperature) 5°C to 32°C 5°C to 32°C
Operating range (relative humidity) 30% to 80%RH 30% to 80%RH
Pressure suction side 1MPa 1MPa
Pressure outlet side 2MPa 2MPa
Mains connection 220-240V/ 50Hz 220-240V/ 50Hz
Power consumption max. 0.37 kW 0.45 kW
Nominal current 1.96 A 2.4 A
Refrigerant R-134a R-134a
Amount of refrigerant 90 g 90 g
GWP factor 1,430 1,430
CO2 equivalent 0.13 t 0.13 t
Water tank 5.5 l 5.5 l
Sound pressure level 48 dB(A) 48 dB(A)
Dimensions (length x width x height) 185 x 330 x 550 mm 185 x 330 x 550 mm
Minimum distance to walls and other objects
A: top: B: rear: C: side:
D: front:
30 cm 20 cm 20 cm 10 cm
30 cm 20 cm 20 cm 10 cm
Weight 14 kg 14 kg

Disposal

Further information is provided on the nameplate.
Dispose of the refrigerant appropriately and according to the national regulations.
The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
The device is operated with fluorinated greenhouse gas which can be dangerous for the environment and contribute to global warming when emitted to the atmosphere.
EN 17
dehumidifier TTK 53 E / TTK 72 E
Page 18
Trotec GmbH & Co. KG
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400 +49 2452 962-200
info@trotec.com www.trotec.com