Trotec TTK 170 S operation manual

Page 1
TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
EN
ORIGINAL INSTRUCTIONS
DEHUMIDIFIER
TRT-BA-TTK140S-170S-350S-650S-TC2018-54-007-EN
Page 2

Table of contents

Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.

Notes regarding the instructions

Symbols

Follow the manual
Information marked with this symbol indicates that the instructions must be observed.
You can download the current version of the instructions and the EUdeclaration of conformity via the following link:
TTK 140 S
https://hub.trotec.com/?id=42763
TTK 170 S
https://hub.trotec.com/?id=42764
Danger
This symbol indicates dangers to the life and health of persons due to extremely flammable gas.
Danger
This symbol indicates dangers to life and health of persons due to the flammable substanceR454C.
Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
TTK 350 S
https://hub.trotec.com/?id=42765
TTK 650 S
https://hub.trotec.com/?id=42766
2 EN
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 3

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Let the device dry out after a wet clean. Do not operate it when wet or when in moist surroundings.
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device and never use it as source of ignition.
Do not cover or transport the device during operation.
Do not sit on the device.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk!
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
Make sure that the air inlet and outlet are not obstructed.
Make sure that the suction side is kept free of dirt and loose objects.
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
Only transport the device in an upright position with an emptied condensation tank or drain hose.
Discharge the collected condensate before transport and storage. Do not drink it. Health hazard!
Safety warnings for devices containing flammable refrigerants
Only position the device in rooms where potentially leaking refrigerant cannot accumulate.
Only position the device in rooms where there is no source of ignition (e.g. open flames, an active gas appliance or an electric heater).
Please note that the refrigerant is odourless.
Only install the device in compliance with the national installation regulations.
Observe the national gas regulations.
Only install, operate and store the device TTK 140 S/ TTK
170 S/ TTK 350 S/ TTK 650 S in a room measuring more
than 4m2.
Store the device in a way that no mechanical damage can occur.
Please note that the connected ducts must not contain any sources of ignition.
R290 is a refrigerant that complies with European environmental regulations. No part of the cooling circuit may be perforated.
R454C comes with a low GWP factor (Global Warning Potential) of146 and an ODP (ozone depletion potential) of0.
EN 3
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 4
Observe the maximum refrigerant capacity in the technical data.
Do not drill through or burn.
Do not use any means other than those recommended by the manufacturer for accelerating the defrosting process.
Every person working with or at the refrigerant circuit must be able to provide a certificate of qualification issued by a body accredited by the industry, demonstrating their competence in the safe use of refrigerants based on a procedure well-known in the industry.
Service work may only be carried out in accordance with the manufacturer's specifications. If maintenance and repair work require the support of additional persons, the person trained in handling flammable refrigerants shall continuously supervise the work carried out.
Unventilated rooms, in which the device is installed, operated or stored, must be built in a way to ensure that potentially leaking refrigerant cannot accumulate. This serves to avoid fire or explosion hazards resulting from an ignition of the refrigerant by an electric furnace, cooking stove or another ignition source.
The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air­conditioning or by Trotec.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the instructions, especially the Safety chapter.
Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.

Safety signs and labels on the device

Note
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
The following safety signs and labels are attached to the device:
TTK 140 S / TTK 170 S

Intended use

Only use the device for drying and dehumidifying room air, while adhering to and following the technical data.
Intended use comprises:
dehumidifying and drying: – living rooms, bedrooms, bathrooms and basements – laundries, holiday homes, camper vans, boats
maintaining the dryness of: – storage spaces, archives, laboratories, garages – bathrooms, wash rooms, changing rooms etc.

Improper use

Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability and guarantee null and void.
TTK350S / 650S
4 EN
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 5
Follow the manual
This symbol indicates that the operating manual must be observed.
Warning
The device is not a toy and does not belong in the hands of children.
Follow the repair manual
Disposal, maintenance and repair work of the refrigerant circuit may only be carried out in accordance with the manufacturer's specifications and by persons having a certificate of qualification. A corresponding repair manual is available from the manufacturer upon request.

Residual risks

Danger Natural refrigerant propane (R290)!
H220 – Extremely flammable gas. H280 – Contains gas under pressure; may explode if heated.
P210 – Keep away from heat, sparks, open flames and other ignition sources. No smoking. P377 – Leaking gas fire: Do not extinguish, unless leak can be stopped safely. P410+P403 – Protect from sunlight. Store in a well­ventilated place.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
Note
When operated with condensation tank, make sure that the condensation tank is inserted correctly! If the condensation tank is removed or not installed correctly, the device does not switch off.
Danger RefrigerantR454C!
H220 – Extremely flammable gas. H280 – Contains gas under pressure; may explode if heated.
P210 – Keep away from heat, sparks, open flames and other ignition sources. No smoking. P381– Eliminate all ignition sources if safe to do so. P403 – Store in a well-ventilated place.
Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
EN 5
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 6

Behaviour in the event of an emergency

1. Switch off the device.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
3. Do not reconnect a defective device to the mains.

Information about the device

Description of the device

The device uses the principle of condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter, the evaporator and to the condenser located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime. The dehumidified, cooled air is slightly warmed at the condenser and blown out again. The drier air thus conditioned mixes with the air in the room. The humidity in the room where the device is positioned is reduced as air constantly circulates through the device.
The condensation is fed from the device through the condensation drain hose connected to the hose connector into an external container or drain.
Optionally, the condensed water can also be discharged from the device by means of a retrofitted condensate pump (see chapter Installing the condensate pump).
For easy operation and transport, the device is fitted with an on/ off switch, an operating hours counter, a transport handle and wheels. Two feet with rubber buffers prevent the device from rolling away.
The device can reduce the relative humidity of a room to approx. 32 %. Due to the heat radiation generated during operation, the room temperature may rise by approx. 1–4°C.
Models
The TTK S series comprises the following devices:
TTK 140 S
TTK 170 S / TTK 350 S
6 EN
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 7
TTK 650 S
1
2
3
4
5
6
7
10
9
8
1
2
8
9
10

Device depiction

Note!
For simplification purposes the figures used in this documentation only depict one device, which can deviate from the actual version. The factual information content remains unaffected. If necessary in case of relevant differences the respective devices will be shown.
No. Designation
1 Air filter at air inlet
2 Fixing bar of the air filter
3 Hose connector for condensation drain hose
(TTK140S, TTK170S and TTK350S only)
4 Condensation tank
(TTK140S, TTK170S and TTK350S only)
5 Transport handle
(TTK170S, TTK350S and TTK650S only)
6 Condensation drain hose
(TTK650S only)
7 Castor (TTK140S)
Wheel (TTK170S/ TTK350S/ TTK650S)
8 Air outlet
9 Operating elements
10 Carrying handle
EN 7
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 8

Transport and storage

A.

Assembly and installation

Note
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

Before transporting the device, observe the following:
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
Do not use the power cable to drag the device.
After unpacking the devices, mount the transport handle as
described in the chapter Assembly and installation.
After transporting the device, observe the following:
Set up the device in an upright position after transport.
Lock the castors of the TTK140S.
After having transported the device in horizontal position,
leave the device to rest for 12to24hours, so the refrigerant can accumulate within the compressor. Wait 12to24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. Any warranty claims will be voided in this case.

Scope of delivery

1x Device
1 x transport handle (TTK170S/ TTK350S/ TTK650S)
1x Manual
1x Condensation drain hose
1x Hose adapter

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.

Assembly

Use tools suitable for the intended task.
Mounting the transport handle (TTK170S/ TTK350S/ TTK650S)
Prior to initial start-up, the transport handle must be attached to the device. To do so, please proceed as follows:
Info
After unpacking the device, the two lower screws must be unscrewed and the transport handle remounted using only one screw (i.e. one screw remains).

Storage

Before storing the device, observe the following:
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
Hold onto the mains plug while pulling the power cable out of the mains socket.
Drain any possibly remaining condensate.
When the device is not being used, observe the following storage conditions:
Only store the device in a room measuring more than 4m2.
Only position the device in rooms where there is no source of ignition (e.g. open flames, an active gas appliance or an electric heater).
dry and protected from frost and heat
in an upright position where it is protected from dust and direct sunlight
with a cover to protect it from invasive dust, if necessary
Place no further devices or objects on top of the device to prevent it from being damaged.
8 EN
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 9
B.

Start-up

A
B
C
C
D
When positioning the device, observe the minimum distance from walls or other objects as described in the Technical data chapter.
Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges.
Make sure that extension cables are completely unrolled.
When positioning the device, keep a sufficient distance to heat sources.
Make sure that no curtains or other objects interfere with the air flow.
When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations.
Inserting the air filter
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
Make sure that the air filter is installed before switching the device on.
Connecting the power cable
Insert the mains plug into a properly secured mains
Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition,
socket.
contact the customer service.
Only position the device in rooms where potentially leaking refrigerant cannot accumulate.
Only position the device in rooms where there is no source of ignition (e.g. open flames, an active gas appliance or an electric heater).
Set the device up in an upright and stable position.
EN 9
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 10

Operation

12
13
11
TTK 650 S TTK 140/170/350 S
Operating elements
No. Designation Meaning
11 Condensation tank indicator
light (TTK140S, TTK170S and TTK350S only)
12 On/off switch Switching the device on and
13 Rotary switch Selection of relative room
Illuminated when the condensation tank is full.
off; Is illuminated when the device is switched on
humidity
Switching the device on
Once you have completely installed the device as described in the Start-up chapter, you can switch it on.
1. Carry out the following inspections prior to switch-on:
ð The following only applies to TTK140S, TTK170S
and TTK350S:
Ensure that the condensation tank is empty and inserted correctly.
ð The following only applies to the TTK650S:
Ensure that the condensation drain hose has been laid and mounted properly.
2. Insert the mains plug into a properly secured mains socket.
3. Switch on the device at the mains switch (12).
4. Ensure that the mains switch (12) is lit.
5. The following only applies to TTK140S, TTK170S and
TTK350S:
Check whether the condensation tank indicator light (11) is out. Otherwise, empty the condensation tank.
6. Adjust the relative room humidity level with the rotary switch (13).
Continuous operation mode
In continuous operation mode, the device dehumidifies the air constantly, regardless of the humidity. To start continuous operation mode, set the rotary switch(13) to Max.
Connecting the condensation drain hose (TTK140S/ TTK170S/ TTK350S)
For continuous operation or unattended dehumidification, please connect a suitable condensation drain hose to the device.
1.
Operating hours/ power consumption counter
The device is optionally also available with a simple operating hours counter or with a combined operating hours and power consumption counter (see fig.). Contact your Trotec customer service.
10 EN
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 11
2.
1/2''
Connecting the condensation drain hose (TTK650S)
For continuous operation or unattended dehumidification, please connect a suitable condensation drain hose to the device.
1.
Automatic defrost
If the room temperature is below 11°C, the evaporator will freeze during dehumidification. The device will then carry out an automatic defrost. The duration of the defrost process can vary.
Do not switch off the device during automatic defrost. Do not remove the mains plug from the mains socket.
Operation with condensate pump (optional)
Note
The connection for the hose adapter is located in the inside of the device.
Optionally, the condensed water can also be discharged from the device by means of a retrofitted condensate pump (see chapter Available accessories). With a pump performance of up to 50m and a maximum pump height of 4m, the condensate can even be continuously discharged across storeys of a building.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.

Available accessories

Warning
Only use accessories and additional equipment specified in the instructions. Using insertion tools or accessories other than those specified in the instructions may cause a risk of injury.
2.
Designation Article number
Air filter TTK140S 7.710.000.332
Air filter TTK170S 7.710.000.332
Air filter TTK350S 7.710.000.334
Air filter TTK650S 7.710.000.335
Condensate pump 6.100.003.020
EN 11
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 12

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damage.
Check the on-site fusing.
Check the filling level of the condensation tank and empty it if necessary. The condensation tank indicator light(11) must not light up.
The device is running, but there is no formation of condensate:
When using the condensate pump: Check the condensation tank and hoses for dirt.
Ensure that the relative room humidity complies with the technical data.
Check the air filter for dirt. If necessary, clean or replace the air filter.
From the outside, check the condenser for dirt (see chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
Your device still does not operate correctly after these checks?
Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright position.
Condensate is leaking:
Check the device for leaks.
The compressor does not start:
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Check whether the overheating protection of the compressor has tripped. Disconnect the device from the mains and let it cool down for approx. 10minutes before reconnecting it.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or loses power:
Check the air inlets and air filters for dirt. Remove external dirt.
From the outside, check the device for dirt (see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company for cooling and air­conditioning or by Trotec.
12 EN
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 13

Maintenance

Maintenance intervals

Maintenance and care interval before every
start-up
Check the air inlets and outlets for
X X
dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and
X X
foreign objects and clean or replace if necessary
Replace the air filter
Check for damage
X
Check the attachment screws
Test run
Empty the condensation tank and/ or drain hose

Maintenance and care log

Device type: .............................................
as needed at least every
2weeks
X X
X X
X X
X
at least every 4weeks
at least every 6months
X
Device number: ....................................
at least annually
X
Maintenance and care interval
Check air inlets and outlets for dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and foreign objects and clean or replace if necessary
Replace the air filter
Check for damage
Check the attachment screws
Test run
Empty the condensation tank and/ or drain hose
Comments
1. Date: ...................................
Signature: ................................
5. Date: ...................................
Signature: ................................
9. Date: ...................................
Signature: ................................
13. Date: .................................
Signature: ................................
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
2. Date: ....................................
Signature: .................................
6. Date: ....................................
Signature: .................................
10. Date: ..................................
Signature: .................................
14. Date: ..................................
Signature: .................................
3. Date: ....................................
Signature: .................................
7. Date: ....................................
Signature: .................................
11. Date: ..................................
Signature: .................................
15. Date: ..................................
Signature: .................................
4. Date: ....................................
Signature: .................................
8. Date: ....................................
Signature: .................................
12. Date: ..................................
Signature: .................................
16. Date: ..................................
Signature: .................................
EN 13
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 14

Activities required before starting maintenance

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec.

Running capacitor

Note
Replace the running capacitor after 10,000operating hours!

Refrigerant circuit

Danger Natural refrigerant propane (R290)!
H220 – Extremely flammable gas. H280 – Contains gas under pressure; may explode if heated.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air­conditioning or by Trotec.
5. Put the air filter back in.
P210 – Keep away from heat, sparks, open flames and other ignition sources. No smoking. P377 – Leaking gas fire: Do not extinguish, unless leak can be stopped safely. P410+P403 – Protect from sunlight. Store in a well­ventilated place.
Danger RefrigerantR454C!
H220 – Extremely flammable gas. H280 – Contains gas under pressure; may explode if heated.
P210 – Keep away from heat, sparks, open flames and other ignition sources. No smoking. P381– Eliminate all ignition sources if safe to do so. P403 – Store in a well-ventilated place.
The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air­conditioning or by Trotec.

Safety signs and labels on the device

Check the safety signs and labels attached to the device at regular intervals. Replace illegible safety signs!
14 EN
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 15

Cleaning the air filter

Note
Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be deformed or rounded. Before reinserting the air filter, make sure that it is undamaged and dry!
The air filter has to be cleaned as soon as it is dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults).
1. Remove the air filter from the device.
2. Clean the filter using a slightly damp, soft, lint-free cloth. If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent.
3. Allow the filter to dry completely. Do not insert a wet filter into the device!
4. Reinsert the air filter into the device.
EN 15
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 16

Emptying the condensation tank

(TTK140S/ TTK170S/ TTK350S)
Info
The compressor always starts with a delay. This protects the compressor and thus increases its lifetime. If you remove the condensation tank from the device and reinsert it after emptying, the compressor will switch back on with a delay of approx.3min. This delay is also enabled in optional hygrostat operation. If the room humidity exceeds the setting of the selection switch, the compressor will only switch back on after a delay. The fan keeps running independently of the compressor. If the condensation tank is removed, the device does not switch off.
1.
3.
4.
2.
If the condensation tank is full, the condensation tank indicator light(11) will be illuminated. The compressor and fan will switch off.

Activities required after maintenance

If you want to continue using the device:
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
Store the device according to the Storage chapter.
16 EN
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 17

Technical annex

Technical data

Parameter Value
Model TTK 140 S TTK 170 S TTK 350 S TTK 650 S
Dehumidification
35 l/ 24h 40 l/ 24h 55 l/ 24h 91 l/ 24h performance @30°C/ 80%RH
Dehumidification
40 l/ 24h 50 l/ 24h 70 l/ 24h 150 l/ 24h performance, max.
Operating range
5 – 32°C 5 – 32°C 5 – 32°C 5 – 32°C (temperature)
Operating range (relative
50%– 90%RH 50%– 90%RH 50%– 90%RH 50%– 90%RH humidity)
Max. permissible
3.1MPa 3.1MPa 1.8MPa 1.8MPa
pressure
Pressure suction side 1.1MPa 1.1MPa 0.5MPa 0.5MPa
Pressure outlet side 3.1MPa 3.1MPa 1.8MPa 1.8MPa
Air volume flow 580m3/h 580m3/h 1000m3/h 1000m3/h
Mains connection 220-240V/ 50Hz 220-240V/ 50Hz 220-240V/ 50Hz 220-240 V/ ~ 50Hz
Power consumption,
0.6kW 0.6kW 1.3kW 1.9kW
max.
Nominal current 2.7A 2.8A 6A 8.6A
Water tank capacity 6l 6l 6l -
Refrigerant R290(propane) R290(propane) R454C(F-Gas) R454C(F-Gas)
Amount of refrigerant 150g 150g 650g 1050g
GWP factor 3 3 146 146
CO2 equivalent 0.00045t 0.00045t 0.09490t 0.15t
Sound pressure level LpA
52dB(A) 52dB(A) 54dB(A) 56dB(A) (1m; complies with DIN45635-01-KL3)
Dimensions (length x width x height) 400x 400x 605mm 540x 490x 963mm 530x 500x 965mm 616x 511x 1022mm
Minimum distance to walls or other objects
top (A):
rear (B):
sides (C):
front (D):
50 cm
50 cm
50 cm
50 cm
50 cm 50 cm 50 cm 50 cm
50 cm 50 cm 50 cm 50 cm
50 cm 50 cm 50 cm 50 cm
Weight 29 kg 32 kg 39 kg 52 kg
EN 17
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 18
Wiring diagram
- Earthing / Erdung
- Common Line / Gemeinsame
- Line / Außenleiter
- On-Off Switch / Geräteschalter 0/1
- Micro Switch (Tank Full) / Mikroschalter Wippe Vollstand (Behälter voll)
- Humidistat / Hygrostat
- Compressor / Kompressor
- Fan motor / Lüftermotor
- Two Way Valve / Abtau-Magnetventil
- Running Capacitor / Motorbetriebskondensator
- Time Counter (Optional) / Zeit Zähler (Zusätzliche)
E N L S1 S3 S4 M1 M2 Y RC H
E L
N
220-240V~50Hz
Schuko Plug
Schukostecker
Time Counter (Optional)
M1
PCB
(XGNF06)
E
S4
Y
L
H
F C NA CC NF N
N
J9
JP11
Alarm
J5
< 2°C
NTC 10kÙ
J7
M2
RC
L
S1
0/1
Wiring diagram with Hour Counter just counting the compressor operation time (Optional)
S3
2
1
4
Empty Bucket
Full
Bucket
- Earthing / Erdung
- Common Line / Gemeinsame
- Line / Außenleiter
- On-Off Switch / Geräteschalter 0/1
- Micro Switch (Tank Full) / Mikroschalter Wippe Vollstand (Behälter voll)
- Humidistat / Hygrostat
- Compressor / Kompressor
- Fan motor / Lüftermotor
- Two Way Valve / Abtau-Magnetventil
- Running Capacitor / Motorbetriebskondensator
- Time + Energy Counter (Optional) / Zeit + Energie Zähler (Zusätzliche)
E N L S1 S3 S4 M1 M2 Y RC HE
Time + Energy Counter (MID approved) (Optional)
HE
Iavg= 5A
NLoutLin
E L
N
220-240V~50Hz
Schuko Plug
Schukostecker
M1
PCB
(XGNF06)
E
S4
Y
RC
F C NA CC NF N
J9
JP11
Alarm
J5
< 2°C
NTC 10kÙ
J7
Wiring diagram with Counter counting energy and time downstream the main switch (Optional)
M2
S1
0/1
L
S3
2
1
4
Empty Bucket
Full
Bucket
TTK140S/ TTK170S/ TTK350S
Operating hours counter Operating hours counter with MID counter
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
18 EN
Page 19
TTK 650 S
E L
N
220-240V~50Hz
Schuko Plug
PCB
(XGNF06)
E
S2
S1
0/1
F C NA CC NF N
J9
JP11
J5
PCB
Status
< 2°C
NTC 10kΩ
Time Counter (Standard)
M2M1
Y
L
RCH
N
J7
E L
N
Schuko Plug
PCB
(XGNF06)
E
S2
J9JP1
J5
J7
< 2°C
NTC 10kÙ
S1
0/1
Time + Energy Counter
HE
Iavg= 5A
NLoutLin
M2M1
Y
RC
F C NA CC NF N
220-240V~50Hz
PCB
Status
Hour counter just counting the compressor operation time (optional)
Counter counting energy and time downstream the main switch (optional)
Operating hours counter Operating hours counter with MID counter
E -Earthing E -Earthing
N -Common Line N -Common Line
L -Line L -Line
S1 -On-Off Switch S1 -On-Off Switch
S2 -Humidistat S2 -Humidistat
M1 -Compressor M1 -Compressor
M2 -Fan motor M2 -Fan motor
Y -Two Way Valve Y -Two Way Valve
RC -Running Capacitor RC -Running Capacitor
H -Time Counter (Optional) HE -Time + Energy Counter (Optional)
P -Water Pump Socket P -Water Pump Socket
EN 19
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 20
Overview of spare parts and spare parts list TTK140S Info
9 4 17 18
15
28
20
8
2233
12
13
3
1
2
21
6
29
5
32
25
26
7
10
11
14
24
27
16
19
23
30
31
The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions.
No. Spare part No. Spare part No. Spare part
1 Main frame 12 Fan motor 23 Humidistat
2 Baseplate 13 Heat exchangers 24 Control´s box
3 Air outlet grille 14 Electronic controller 25 Defrost valve
4 Air inlet grille 15 Humidistat knob 26 Top hood thermal isolating foam
5 Fan motor brackets 16 Control panel sticker 27 Hose connector
6 Pre-coated PVC hood 17 Air filter 28 Flexible hose
7 Water tank base plate (complete set) 18 Air filter bracket 29 Defrost sensor
8 Condensates water pan 19 Full water tank switching system 30 Hour counter gap cover
9 Plastic grip 20 Water tank 31 Compressor NLY90RAb
10 Main switch 21 Cable gland + electric terminal block 32 Spinning castor without brake
11 Fan blade 22 Power supply cable 33 Spinning castor with brake
20 EN
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 21
Overview of spare parts and spare parts list TTK170S Info
9 4 17 18
15
36
20
8
22293047
25
12
13
3
1
2
21
6
37
5
26
27
31
32
7
10
11
34
14
24
35
16
19
23
33
38
28
The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions.
No. Spare part No. Spare part No. Spare part
1 Main frame 14 Electronic controller 27 Saddle foot
2 Baseplate 15 Humidistat knob 28 Handle´s saddle spacers
3 Air outlet grille 16 Control panel sticker 29 Wheel
4 Air inlet grille 17 Air filter 30 Wheel´s axle
5 Fan motor brackets 18 Air filter bracket 31 Defrost valve
6 Pre-coated PVC hood 19 Full water tank switching system 32 Top hood thermal isolating foam
7 Water tank base plate (complete set) 20 Water tank 33 Running capacitor
8 Condensates water pan 21 Cable gland + electric terminal block 34 Compressor
9 Plastic grip 22 Power supply cable 35 Hose connector
10 Main switch 23 Humidistat 36 Flexible hose
11 Fan blade 24 Control´s box 37 Defrost sensor
12 Fan motor 25 Tubular handle 38 Hour counter gap cover
13 Heat exchangers 26 Tubular foot 39 Axle´s saddle spacer
EN 21
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 22
Overview of spare parts and spare parts list TTK350S Info
9 4 17 18
15
36
20
8
22293047
25
12
13
3
1
2
21
6
37
5
26
27
31
32
7
10
11
34
14
24
35
16
19
23
33
38
28
The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions.
No. Spare part No. Spare part No. Spare part
1 Main frame 14 Electronic controller 27 Saddle foot
2 Baseplate 15 Humidistat knob 28 Handle´s saddle spacers
3 Air outlet grille 16 Control panel sticker 29 Wheel
4 Air inlet grille 17 Air filter 30 Wheel´s axle
5 Fan motor brackets 18 Air filter bracket 31 Defrost valve
6 Pre-coated PVC hood 19 Full water tank switching system 32 Top hood thermal isolating foam
7 Water tank base plate (complete set) 20 Water tank 33 Running capacitor
8 Condensates water pan 21 Cable gland + electric terminal block 34 Compressor
9 Plastic grip 22 Power supply cable 35 Hose connector
10 Main switch 23 Humidistat 36 Flexible hose
11 Fan blade 24 Control´s box 37 Defrost sensor
12 Fan motor 25 Tubular handle 38 Hour counter gap cover
13 Heat exchangers 26 Tubular foot 39 Axle´s saddle spacer
22 EN
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 23
Overview of spare parts and spare parts list TTK650S Info
1464
40
16
29
33
10
12
9
27
13
5
8
25
1722 1823 24
34
35
20
19
31
15
36
38
37
28
30
32
3
39
1
11
21
7
2
26
The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions.
No. Spare part No. Spare part No.Spare part
1 Baseplate 15 Handle's saddle spacer 29 Main switch
2 Structural element 16 Plastic grip 30 Control's box
3 Air outlet ventilation grille 17 Power supply cable 31 Control panel sticker
4 Air inlet ventilation grille 18 Cable gland + electric terminal block 32 Electronic controller
5 Back cover 19 Fan motor 33 Heat exchanger
6 Pre-coated PVC hood 20 Fan blade 34 Compressor
7 Tubular handle 21 Fan motor brackets 35 Running capacitor
8 Tubular foot 22 Wheel 36 Defrost sensor
9 Water pan 23 Wheel's axle 37 Defrost valve
10 Hose fitting 24 Axle's saddle spacer 38 Defrost valve coil
11 Hidraulic plug 25 Plastic feet 39 Top hood thermal isolating foam
12 Hose 26 Hour counter gap cover 40 Air filter bracket
13 1/4 turn lock 27 Humidistat knob
14 Air filter 28 Humidistat
EN 23
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 24

Disposal

The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website https://de.trotec.com/shop/.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
The device is operated with fluorinated greenhouse gas which can be dangerous for the environment and contribute to global warming when emitted to the atmosphere.
Further information is provided on the nameplate. Dispose of the refrigerant appropriately and according to the
national regulations.
Have the refrigerant (propane) disposed of appropriately and according to the national regulations by a company with the relevant certification (European Waste Catalogue 160504).

Declaration of conformity

Declaration of conformity TTK140S / TTK170S / TTK350S/ TTK 650S
The text below sets out the contents of the declaration of conformity. The signed declaration of conformity can be found at https://hub.trotec.com/?id=42763.
Declaration of conformity
in accordance with the ECMachinery Directive 2006/42/EC, AnnexII, Part1,
SectionA
Herewith, we– TrotecGmbH– declare that the machinery designated below was developed, constructed and produced in compliance with the requirements of the ECMachinery Directive in the version 2006/42/EC.
Relevant EUdirectives:
2011/65/EU: 01/07/2011
2014/30/EU: 29/03/2014
2012/19/EU: 24/07/2012
2015/863/EU
Applied harmonised standards:
EN 60335-1:2012
EN 60335-1:2012/AC:2014
EN 60335-1:2012/A11:2014
EN 60335-1:2012/A13:2017
EN 60335-2-40:2003
EN 60335-2-40:2003/A11:2004
EN 60335-2-40:2003/A12:2005
EN 60335-2-40:2003/A1:2006
EN 60335-2-40:2003/AC:2006
EN 60335-2-40:2003/A2:2009
EN 60335-2-40:2003/AC:2010
EN 60335-2-40:2003/A13:2012
EN 60335-2-40:2003/A13:2012/AC:2013
EN 61000-3-2:2014
EN 61000-3-3:2013
Applied national standards and technical specifications:
IEC 60335-1:2010
IEC 60335-1:2010/AMD1:2013
IEC 60335-1:2010/AMD2:2016
IEC 60335-2-40:2018
IEC 61000-3-2:2018
IEC 61000-3-3:2013
IEC 61000-3-3:2013/AMD:2017
EN 55014-1:2017
CISPR 14-1:2016
EN 55014-2:2015
CISPR 14-2:2015
Manufacturer and name of the authorised representative of the technical documentation:
Trotec GmbH Grebbener Straße 7, D-52525 Heinsberg Phone: +49 2452 962-400 E-mail: info@trotec.de
Product model/ product:
TTK140S / TTK170S / TTK350S/ TTK650S
Place and date of issue: Heinsberg, 05/03/2020
Product type:
Year of manufacture as of:
24 EN
dehumidifier
2020
Detlef von der Lieck, Managing Director
dehumidifier TTK 140 S / TTK 170 S / TTK 350 S / TTK 650 S
Page 25
Trotec GmbH
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400 +49 2452 962-200
info@trotec.com www.trotec.com
Loading...