Declaration of conformity ...................................................22
Notes regarding the instructions
Symbols
Danger
This symbol indicates dangers to the life and health of
persons due to extremely flammable gas.
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
TTK 166 ECO
https://hub.trotec.com/?id=41294
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use.
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
•Do not use the device in potentially explosive rooms or
areas and do not install it there.
•Do not use the device in aggressive atmosphere.
•Only put up the device in an upright, stable position on firm
ground.
•Let the device dry out after a wet clean. Do not operate it
when wet.
•Do not use the device with wet or damp hands.
•Do not expose the device to directly squirting water.
•Never insert any objects or limbs into the device.
•Do not cover or transport the device during operation.
•Do not sit on the device.
•This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
•Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.
2EN
dehumidifier TTK 166 ECO
Page 3
•Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
•The electrical connection must correspond to the
specifications in chapter Technical data.
•Insert the mains plug into a properly secured mains
socket.
•Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
•Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
•Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
•Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
•When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.
•Make sure that the air inlet and outlet are not obstructed.
•Make sure that the suction side is kept free of dirt and
loose objects.
•Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
•Only transport the device in an upright position with an
emptied condensation tank or drain hose.
•Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!
Safety warnings for devices containing flammable
refrigerants
•Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
•Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
•Please note that the refrigerant is odourless.
•Only install the device in compliance with the national
installation regulations.
•Observe the national gas regulations.
•Only install, operate and store the device in a room
measuring more than 15m2.
•Store the device in a way that no mechanical damage can
occur.
•Please note that the connected pipelines must not contain
any sources of ignition.
•R290 is a refrigerant that complies with European
environmental regulations. No part of the cooling circuit
may be perforated.
•Observe the maximum refrigerant capacity in the technical
data.
•Do not drill through or burn.
•Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.
•Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.
•Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.
•Unventilated rooms, in which the device is installed,
operated or stored, must be built in a way to ensure that
potentially leaking refrigerant cannot accumulate. This
serves to avoid fire or explosion hazards resulting from an
ignition of the refrigerant by an electric furnace, cooking
stove or another ignition source.
•The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and airconditioning or by Trotec.
Intended use
Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
Intended use comprises:
•dehumidifying and drying:
– living rooms, bedrooms, bathrooms and basements
– laundries, holiday homes, camper vans, boats
•Do not place the device on wet or flooded ground.
•Do not place any objects, e.g. clothing, on the device.
•Do not use the device outdoors.
•Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
•Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
Personnel qualifications
People who use this device must:
•be aware of the dangers that occur when working with
electric devices in damp areas.
•have read and understood the instructions, especially the
Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.
Follow the repair manual
Disposal, maintenance and repair work of the
refrigerant circuit may only be carried out in
accordance with the manufacturer's specifications and
by persons having a certificate of qualification. A
corresponding repair manual is available from the
manufacturer upon request.
Residual risks
Danger
Natural refrigerant propane (R290)!
H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames and
other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak
can be stopped safely.
P410+P403 – Protect from sunlight. Store in a wellventilated place.
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
TTK166 ECO
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Follow the manual
This symbol indicates that the operating manual must
be observed.
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
4EN
dehumidifier TTK 166 ECO
Page 5
Behaviour in the event of an emergency
1
2
3
4
5
7
10
11
6
8
9
Device depiction
1. Switch off the device.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Information about the device
Description of the device
The device uses the principle of condensation to automatically
dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter,
the evaporator and to the condenser located behind it. The air is
cooled at the cold evaporator until it is below the dew point.
Water vapour contained in the room air precipitates on the
evaporator fins as condensation or rime. The dehumidified,
cooled air is slightly warmed at the condenser and blown out
again. The drier air thus conditioned mixes with the air in the
room. The humidity in the room where the device is positioned
is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase through the integrated drain nozzle into the
condensation tank below. It is fitted with a float to measure the
filling level.
Defrosting of the device takes place electronically in air
circulation mode.
The device has a control panel for operating and controlling the
functions.
Once the maximum filling level of the condensation tank is
reached or in case the condensation tank is not installed
correctly, the condensation tank indicator light (see chapter
Operating elements) on the control panel is illuminated. The
device switches off. The condensation tank indicator light only
goes out again once the emptied condensation tank is
reinserted.
Optionally, the condensed water can be drained by attaching a
hose at the condensation connection.
The device can reduce the relative humidity of a room to
approx. 30 %.
Because of the heat radiation generated during operation, the
room temperature may rise slightly.
EN5
No.Designation
1Transport handle
2Control panel
3Transport wheel
4Condensation drain hose connection
5Air outlet
6Power cable holder
7Tread plate (transport aid)
8Foot
9Condensation tank (behind cover)
10Air inlet
11Air filter
dehumidifier TTK 166 ECO
Page 6
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
To make the device easier to transport, it is fitted with a
transport handle and two wheels.
Before transporting the device, observe the following:
•Switch off the device.
•Hold onto the mains plug while pulling the power cable out
of the mains socket.
•Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
•Do not use the power cable to drag the device.
•Do not incline the device by more than 45°, for otherwise
the device could be damaged.
Storage
Before storing the device, observe the following:
•Drain the remaining condensate from the device and the
condensation drain hose (see chapter Maintenance).
•Hold onto the mains plug while pulling the power cable out
of the mains socket.
When the device is not being used, observe the following
storage conditions:
•Only store the device in a room measuring more than
15m2.
•Dry and protected from frost and heat
•In an upright position where it is protected from dust and
direct sunlight
•With a cover to protect it from invasive dust, if necessary
•Place no further devices or objects on top of the device to
prevent it from being damaged.
Assembly and installation
Scope of delivery
•1x Device
•1x Air filter
•2x Transport wheel
•1 x Transport handle
•1 x Foot
•1x Axle
•2 x Washer
•2x Nut
•4 x Large screw
•4 x Small screw
•1x Condensation drain hose, length: 1 m,
diameter: 13 mm
•1x Manual
•Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
•Set up the device in an upright position after transport.
•Leave the device to rest for 12to24hours, so the
refrigerant can accumulate within the compressor. Wait
12to24hours before switching the device back on! Acting
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
6EN
dehumidifier TTK 166 ECO
Page 7
Assembly
Use tools suitable for the intended task.
Mounting the foot
The foot must be attached to the device prior to initial start-up.
To do so, please proceed as follows:
1. Place the device on its front side.
2. Mount the foot to the front bottom side of the device using
the four small screws.
4. Screw the two nuts to the axle.
Mounting the wheels
Prior to initial start-up, the transport wheels and the axle must
be attached to the device. To do so, please proceed as follows:
ü The device is placed on its front side.
1. Use the four large screws to fasten the axle to the rear
bottom side of the device.
5. After mounting the wheels and the feet, place the device in
an upright position.
Note
Leave the device to rest for 12to24hours, so the
refrigerant can accumulate within the compressor.
Wait 12to24hours before switching the device back
on! Acting contrary might lead to compressor damage
and a malfunctioning device. Any warranty claims will
be voided in this case.
2. Attach the two wheelsto the axle.
3. Attach the two washersto the axle.
EN7
dehumidifier TTK 166 ECO
Page 8
Mounting the transport handle
A
B
C
C
D
Prior to initial start-up, the transport handle must be attached to
the device. To do so, please proceed as follows:
1. Loosen bothscrews and nuts of each of the two holders.
2. Insert the transport handle into the holder.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical data.
3. Screw the transport handle to the two holders.
4. Check the transport handle for tight fit.
•Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
•Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
•Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
•Only put up the device in an upright, stable position on firm
ground.
•Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
•Make sure that extension cables are completely unrolled.
•When positioning the device, keep a sufficient distance to
heat sources.
•Make sure that no curtains or other objects interfere with
the air flow.
•When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.
•Do not incline the device by more than 45°, for otherwise
the device could be damaged.
8EN
dehumidifier TTK 166 ECO
Page 9
Inserting the air filter
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
•Make sure that the air filter is installed before switching
the device on.
Inserting the condensation tank
•Ensure that the float inside the condensation tank is
inserted correctly.
•Ensure that the condensation tank is empty and inserted
correctly.
Connecting the power cable
•Insert the mains plug into a properly secured mains
socket.
EN9
dehumidifier TTK 166 ECO
Page 10
Operation
12
13
14
15
16
18
22
20
23
24
21
17
25
26
27
28
19
Notes:
•Avoid open doors and windows.
•After being switched on, the device operates fully
automatically.
•The compressor switches on approx.3minutes after the
device has been switched on.
•The fan continuously runs in dehumidification mode until
the device is switched off.
Operating elements
No.DesignationMeaning
12DisplayIndicates the current relative room
humidity
Indicates the desired relative room
humidity during setting.
Indicates the current room
temperature.
Indicates the number of hours
during timer programming
Indicates compressor and fan
operation
Indicates whether the
condensation tank is full or not
installed correctly
Indicates automatic defrost
Indicates automatic switch-on and
switch-off
No.DesignationMeaning
13POWER buttonPower button:
Switches the device on or off.
14TIMER buttonProgramming the timer for
automatic switch-on or switch-off
15Arrow buttonsFor setting the relative room
16
humidity
For setting the number of hours
for the timer function
17Room temperature
segment display
Indicates the current room
temperature
Indicates error codes, see chapter
Errors and faults
21CURRENT indicationIlluminated when the current room
humidity is displayed
22Room humidity
segment display
Indicates the current relative room
humidity
Indicates the desired relative room
humidity during setting.
Indicates error codes, see chapter
Errors and faults
23FULL indicationIs displayed when the
condensation tank is full or not
installed correctly
24Fan speed indication Fan operation indicator, animated
25FROST indicationIs displayed when automatic
defrosting is in progress.
26Hours segment
display
Indicates the number of hours
during timer programming
Indicates the number of hours
until automatic switch-on or
switch-off
27T OFF indicationAutomatic switch-off activated
28T ON indicationAutomatic switch-on activated
10EN
dehumidifier TTK 166 ECO
Page 11
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
Note
Only use the device in an upright position, otherwise
the compressor could be damaged.
Info
As soon as the device is connected to the mains, it
starts running in standby mode and displays the
current humidity level(22) and room temperature(17).
1. Press the POWER button(13).
ð DEHUM is displayed on the dehumidification
indicator(18).
ð After approx. 3minutes the compressor switches on.
The bars of the dehumidification indicator(18) light up
alternately.
Setting the operating mode
Setting the desired relative room humidity
You can change the desired relative room humidity at any time.
1. Press the arrow buttons(15, 16) to set the desired relative
room humidity. Setting is possible within the range
between 10% and 95% in steps of 1%.
ð If you press and hold the arrow buttons, the setting
changes more rapidly.
ð The desired relative room humidity is indicated in the
room humidity segment display(22) for
approx.10seconds. Then the current relative room
humidity is displayed again.
Dehumidification
The compressor switches on after approx. 3minutes.
The device keeps running until reaching the desired relative
room humidity. Then the compressor switches off and the fan
keeps running. Once the desired relative room humidity is
exceeded, the compressor switches back on.
The desired relative room humidity can be set within a setting
range from10% to95% in increments of1%.
Info
The effective dehumidification range lies
between30% and80%, even if the device allows for
relative humidity levels between10% and95%.
The fan speed depends on the room humidity and cannot be set.
Setting the timer
For the device to switch on or off automatically after a
predefined number of hours (max. 24hrs) you can programme
the timer.
The timer has two modes of operation:
•automatic switch-on upon expiry of a preset number of
hours.
•automatic switch-off upon expiry of a preset number of
hours.
The timer can be programmed in increments of 1hour
(1to 24h).
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Info
If the TIMER button(14) is pressed too long
(approx. 10 s), the device might switch over to the
mode for setting the desired relative room humidity.
Automatic switch-on
1. Switch the device off.
2. Press the TIMER button(14).
ð The number of hours flashes in the hours segment
display(26).
3. Press the arrow buttons(15, 16) to set the desired number
of hours.
4. Wait for approx. 5seconds in order to save the setting.
ð The T ON indication(28) appears on the display.
ð The hours segment display(26) indicates the number of
hours.
ð The timer setting equals the desired number of hours.
ð The device starts after the set time has passed.
Note regarding automatic switch-on:
•Pressing the POWER button(13) deactivates the automatic
switch-on function.
•If you select 0hours, the timer will be deactivated.
EN11
dehumidifier TTK 166 ECO
Page 12
Automatic switch-off
ü The device is switched on.
1. Press the TIMER button(14).
ð The number of hours flashes in the hours segment
display(26).
2. Press the arrow buttons(15, 16) to set the desired number
of hours.
3. Wait for approx. 5seconds in order to save the setting.
ð The T OFF indication(27) appears on the display.
ð The hours segment display(26) indicates the number of
hours.
ð The timer setting equals the desired number of hours.
ð The device switches off after the set period of time.
Note regarding automatic switch-off:
•Pressing the POWER button(13) deactivates the automatic
switch-off function.
•If you select 0hours, the timer will be deactivated.
Memory function
During short power failures, the device memorizes the desired
relative room humidity. Once the power supply has been
restored, the device will start automatically.
Operation with hose attached to the condensation
connection
For continuous operation or unattended dehumidification, please
connect a suitable condensation drain hose to the device.
Info
When connecting the condensation drain hose for the
first time, you first have to prepare the condensation
tank. For this purpose, the plug must be unscrewed
from the condensation tank and the condensation tank
must be pierced at this point.
ü The device is switched off.
1. Open the front cover.
Auto stop function
If the condensation tank is full, not inserted correctly or the
desired relative room humidity has been reached, the device will
stop automatically. The fan keeps running for approx. 3minutes
and then switches off.
Info
The device does not switch off when the condensation
tank is removed. Always switch off the device and
disconnect it from the mains before removing the
condensation tank.
2. Remove the condensation tank.
3. Guide the condensation drain hose through the hole in the
device's bottom panel.
4. Push one end of the hose onto the hose connection at the
condensation tank.
12EN
dehumidifier TTK 166 ECO
Page 13
5. Refit the condensation tank into the device.
6. Guide the other hose end to a suitable drain or sufficiently
dimensioned collection container. Please note that the
hose must not be kinked.
Remove the hose and refit the plug on the condensation tank if
you want to collect the condensate in the condensation tank
again. Allow the hose to dry prior to storage. The hose can be
connected in any operating mode for continuous operation.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device will then carry out an
automatic defrost. Dehumidification is briefly interrupted during
defrosting. The fan keeps running.
Defrosting of the device takes place electronically in air
circulation mode. In defrost mode, the compressor switches off
while the fan keeps running and circulates the compressor's
waste heat around the evaporator for defrosting.
The duration of the defrost process can vary, but it does not
exceed 8min. Do not switch off the device during automatic
defrost. Do not remove the mains plug from the mains socket.
The FROST indication(25) is illuminated during automatic
defrosting.
Setting the correction value for the room humidity
The ambient conditions might make it necessary to determine a
correction value for the room humidity. This correction value is
always added to or subtracted from the current room humidity
value.
Example: The displayed room humidity is always 5 increments
too high => change the correction value to -5
The correction value's default setting is 0. The correction value
can be set in the range from -9 to +9.
ü The CURRENT indication(21) appears on the display(12).
1. Press the TIMER button(14) for approx. 10s until an
acoustic signal is emitted.
ð The SET(20) and CURRENT(21) indications flash.
2. Press the arrow buttons(15, 16) to set the desired
correction value.
ð The desired correction value is indicated in the room
humidity segment display(22) for approx.10seconds.
Then the current relative room humidity is displayed
again.
ð The correction value has been saved.
Info
Please note that the set correction value also
influences the desired or set room humidity. The
correction value is applied to every room humidity
measurement.
EN13
dehumidifier TTK 166 ECO
Page 14
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•Switch off the device.
•Hold onto the mains plug while pulling the power cable out
of the mains socket.
•If necessary, remove the condensation drain hose and any
residual fluid from it.
•Empty the condensation tank, if need be.
•Clean the device according to the Maintenance chapter.
•Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•Check the power connection.
•Check the power cable and mains plug for damage.
•Check the on-site fusing.
•Check the filling level of the condensation tank and empty
it if necessary. The FULL indication(23) must not appear
on the display.
•Check the condensation tank for correct seating.
•Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but there is no formation of
condensate:
•Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
•Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•Ensure that the relative room humidity complies with the
technical data.
•Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
•Check the air filter for dirt. If necessary, clean or replace
the air filter.
•From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
•The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device is loud or vibrates:
•Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
•Check the device for leaks.
The compressor does not start:
•Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•Ensure that the relative room humidity complies with the
technical data.
•Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
•Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10minutes before
reconnecting it.
•The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device frequently defrosts itself:
•If the temperature at the internal temperature sensor is
≤-1°C, the device defrosts itself approx. every 25min.
This is not an error but a normal device function. No
measures are required.
•If there is an error at the internal temperature sensor(error
E1), the device defrosts itself approx. every 20min for up
to 8min, see chapter Error codes.
The device gets very warm, is loud or is losing
performance:
•Check the air inlets and air filters for dirt. Remove external
dirt.
•From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and airconditioning or by Trotec.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
14EN
dehumidifier TTK 166 ECO
Page 15
Error codes
The following error messages can be displayed on the segment
displays(17, 22):
Error codeCauseRemedy
E1Error at the
temperature sensor
of the evaporator
E2 / E3Error at the
humidity and
temperature sensor
EELeak in the coolant
circuit
The device continues to
operate, but it defrosts
itself approx. every 20min
for up to 8min.
Briefly disconnect the
device from the mains
while defrosting is not in
progress.
Should the error still be
displayed after the restart,
please contact the
customer service.
The device continues to
operate and dehumidifies
continuously regardless of
the humidity level.
The humidity and
temperature sensor may
have to be replaced.
Please contact the
customer service.
Disconnect the device
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.
Check air inlets and outlets for dirt
and foreign objects and clean
ifnecessary
Clean the exterior
Visually check the inside of the
device for dirt
Check the air filter for dirt and
foreign objects and clean or
replace if necessary
Replace the air filter
Check for damage
Check attachment screws
Test run
Empty the condensation tank and/
or drain hose
Comments
1. Date: ...................................
Signature: ................................
5. Date: ...................................
Signature: ................................
9. Date: ...................................
Signature: ................................
13. Date: .................................
Signature: ................................
12345678910111213141516
2. Date: ....................................
Signature: .................................
6. Date: ....................................
Signature: .................................
10. Date: ..................................
Signature: .................................
14. Date: ..................................
Signature: .................................
3. Date: ....................................
Signature: .................................
7. Date: ....................................
Signature: .................................
11. Date: ..................................
Signature: .................................
15. Date: ..................................
Signature: .................................
4. Date: ....................................
Signature: .................................
8. Date: ....................................
Signature: .................................
12. Date: ..................................
Signature: .................................
16. Date: ..................................
Signature: .................................
16EN
dehumidifier TTK 166 ECO
Page 17
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•Switch the device off.
•Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Refrigerant circuit
Danger
Natural refrigerant propane (R290)!
H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if
heated.
P210 – Keep away from heat, sparks, open flames and
other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak
can be stopped safely.
P410+P403 – Protect from sunlight. Store in a wellventilated place.
•The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and airconditioning or by Trotec.
Safety signs and labels on the device
Check the safety signs and labels attached to the device at
regular intervals. Replace illegible safety signs!
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Visual inspection of the inside of the device for dirt
1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the
device cleaned by a specialist company for cooling and airconditioning or by Trotec.
5. Put the air filter back in.
Cleaning the air filter
Note
Ensure that the air filter is not worn or damaged. The
corners and edges of the air filter must not be
deformed or rounded. Before reinserting the air filter,
make sure that it is undamaged and dry!
The air filter has to be cleaned as soon as it is dirty. This is
brought to light e.g. by a reduced capacity (see chapter Errors
and faults).
1. Remove the air filter from the device.
EN17
dehumidifier TTK 166 ECO
Page 18
2. Clean the filter using a slightly damp, soft, lint-free cloth. If
the filter is heavily contaminated, clean it with warm water
mixed with a neutral cleaning agent.
3. Allow the filter to dry completely. Do not insert a wet filter
into the device!
4. Reinsert the air filter into the device.
Emptying the condensation tank
If the condensation tank is full or not installed correctly, the
FULL indication(23) will light up on the display. The compressor
and fan will switch off.
1. Take the condensation tank out of the device.
2. Empty the condensation tank over a drain or sink.
3. Rinse the tank with clear water. Clean the tank regularly
using a mild cleaning agent (no detergent!).
4. Refit the condensation tank into the device.
Make sure not to damage the float when inserting or
removing the condensation tank.
In doing so, make sure that the float is positioned
correctly.
In doing so, make sure that the condensation tank is
inserted correctly, for otherwise the device cannot be
switched back on.
Activities required after maintenance
If you want to continue using the device:
•Leave the device to rest for 12to24hours, so the
refrigerant can accumulate within the compressor. Wait
12to24hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
•Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•Store the device according to the Storage chapter.
The icon with the crossed-out waste bin on waste
electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website https://de.trotec.com/shop/.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
The device is operated with fluorinated greenhouse gas which
can be dangerous for the environment and contribute to global
warming when emitted to the atmosphere.
Further information is provided on the nameplate.
Dispose of the refrigerant appropriately and according to the
national regulations.
Have the refrigerant (propane) disposed of appropriately and
according to the national regulations by a company with the
relevant certification (European Waste Catalogue 160504).
Declaration of conformity
Applied harmonised standards:
•EN 60335-1:2012
•EN 60335-1:2012/A11:2014
•EN 60335-1:2012/A13:2017
•EN60335-2-40:2003
•EN 60335-2-40:2003/A11:2004
•EN 60335-2-40:2003/A12:2005
•EN 60335-2-40:2003/A1:2006
•EN 60335-2-40:2003/A2:2009
•EN 60335-2-40:2003/A13:2012
•EN 61000-3-3:2013
•EN 62233:2008
Applied national standards and technical specifications:
•AfPS GS 2019:01 PAK
•EN 55014-1:2017
•EN 55014-2:2015
•EN 61000-3-3:2013/A1:2019
•EN 60335-1:2012/A1:2019
•EN 60335-1:2012/A2:2019
•EN IEC 61000-3-2:2019
Manufacturer and name of the authorised representative of
the technical documentation:
The text below sets out the contents of the declaration of
conformity. The signed declaration of conformity can be found
at https://hub.trotec.com/?id=41294.
Declaration of conformity
in accordance with the ECMachinery Directive 2006/42/EC,
AnnexII, Part1, SectionA
Herewith, we– TrotecGmbH– declare that the machinery
designated below was developed, constructed and produced in
compliance with the requirements of the ECMachinery
Directive in the version 2006/42/EC.
Product model/ Product:
Product type:
Year of manufacture as of:
TTK 166 ECO
dehumidifier
2020
Relevant EU directives:
•2011/65/EU: 01/07/ 2011
•2012/19/EU: 24/07/2012
•2014/30/EU: 29/03/2014
Place and date of issue:
Heinsberg, 22.01.2018
Detlef von der Lieck, Managing Director
22EN
dehumidifier TTK 166 ECO
Page 23
Trotec GmbH
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
info@trotec.com
www.trotec.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.