This device uses the principle of condensation to automatically
dehumidify rooms. To do so, the device can be used in continuous
operation.
The fan sucks damp room air through the air inlet (5), the air
filter (7), the evaporator and to the condenser located behind it.
The air is cooled at the cold evaporator until it is below the dew
point. Water vapour contained in the room air precipitates on the
evaporator fins as either condensation or frost. The dehumidified,
cooled air is warmed again and blown out from the air outlet (6).
The drier air which is prepared in this way mixes with the air in the
room. The humidity in the room where the device is positioned is
reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the
condensed water either drops continuously or only during the
defrost phase into the condensation tray. The condensation is fed
through a pressure-resistant pipe connection and out of the device
at a preinstalled condensation drain hose (4).
The condensed water can be diverted by retrofitting a
condensation pump.
Device depiction and operating elements
For easy operation, the device is fitted with a control panel (2) and
for easy transport, it is fitted with a bar handle (1) and wheels (3).
The device can reduce the relative humidity of a room by up to
approx. 35 %. Because of the heat radiation which is tied up in
operation, the room temperature can rise by approx. 1 – 3 °C.
ModelTTK 1500
Dehumidifying capacity, max.400 l / 24 h
Dehumidifying capacity (20 °C / 60 % relative humidity)100 l / 24 h
Suitable for room dimensions up to:
construction drying or clearing water damages
maintaining dryness
Operating temperature0-40 °C
Working range for relative humidity35-100 %
Volume of airflow, max.2200 m³/h
Electric connection400 V / 50 Hz / 6.75 A
Power consumption, max.2.7 kW
Power consumption, average1.7 kW
Fuse (home)10 A
CompressorReciprocating
RefrigerantR407c
Amount of refrigerant2.5 kg
Weight141 kg
Dimensions (HxDxW)660 x 660 x 1313 mm
Minimum distance from walls of other objectsA: Above: 50 cm
Sound pressure level LpA (3 m; complies with DIN 45635-01-KL3)58 dB(A)
1700 m³
3400 m³
B: Behind: 50 cm
C: Side: 50 cm
D: Front: 50 cm
Power consumption
The device's power consumption depends on the current room
temperature and relative humidity.
Multiply the operating hours (see operating hours counter (12)) by
a consumption value of one kilowatt per hour to determine the
approximate power consumption.
To determine the precise power consumption, a separate energy
cost gauge can be set between the construction dryer and the
power source. Contact Trotec customer service if you want this
alternative version.
ENOperating Manual – Dehumidifier TTK 15003
Page 6
Cooling circuit diagram
EVAPORATOR
COMP
AIR
CONDENSER
RECEIVER
DRIER
LIQUID
INDICATOR
TEV
VALVE
SOLENOID
PHIAL
INE-3-GA
SUCTION
ACCUMULATOR
SCHRADER
SERVICE
LP
SCHRADER
SERVICE
HP
HP
LP
PORT
PROCESS
RECEIVER/DRIER ASSY
INSULATION
N
CONTINUO US
MAINS LAMP
CONTROL SWITCH
FAN MODE
SWITCH
CYCLE
FAULT LAMP
FAN MOTOR
FAN
CAP'
DELAY
TIMER
CONTACTOR
COMPRESSOR
CONDENSATE
PUMP
PUMP FUSE
HUMIDISTAT
FLOAT SWITCH
RELAY No 1
ISOLATOR
RELAY No 2
HIGH LEVEL
PUMP RUN
FLOAT SWITCH
L1 L3 L2
HOURS RUN
METER
FAN FUSE
RELAY No 3
32
112
(COM)
2
(N/O)
(N/C)
MAKES 1-3 ON
TEMP FALLING
DEFROST VALVE
DEFROST
THERMOSTAT
DEFROST LAMP
(COM) 7
(N/C) 1A
B
C
S
R
1
3
56 (N/O)
4 (N/O)
2 (N/O)
A2A1
9
(COM)
(N/O) 6A
B
BA
(COM) 7
4 (N/O)
1
3
4
1
C(COM)
(N/C)L
LP SWITCH
BREAKS ON
PRESSURE FALLING
H(N/C)
C(COM)
HP SWITCH
BREAKS ON
PRESSURE RISING
(F3)
(F2)
CONTROL FUSE
(F1)
Circuit diagram
4Operating Manual – Dehumid ifier TTK 1500EN
Page 7
Safety
Read this manual carefully before starting or using the
device. Store the manual near the device or its site of use!
Intended use
Only use the device TTK 1500 as a mobile industrial dryer for
drying and dehumidifying room air, while adhering to and
following the technical data.
• Do not use the device in potentially explosive rooms.
• Do not use the device in atmospheres containing oil, sulphur,
chlorine, acid or salt.
• Do not operate the device in rooms which are pressurised with
acetone, undiluted acids or solvents.
• Set the device in an upright and stable position.
• Do not expose the device to directly squirting water during
operation.
• Ensure that the air inlet and outlet are not obstructed.
• Ensure that the side of the device where the air inlet is found
is kept free of dirt and loose objects.
• Never insert objects or limbs into the device.
• Do not cover or transport the device during operation.
• Do not sit on the device.
• Ensure that all electric cables outside of the device are
protected from damage (e.g. from animals).
• Only use extensions to the electric cable which are appropriate
to the device power consumption, the length of its cable and
its use. Avoid electrical overload.
• Only transport the device in an upright position with an
emptied condensation pump and tray.
• Dispose of the collected condensation. Do not drink it. There is
a risk of infection!
Intended use encapsulates:
• drying and dehumidifying:
– production plants, underground rooms
– store rooms, archives, laboratories
– rooms and areas after water damages from burst pipes or
flooding
• maintaining the dryness of:
– instruments, devices and files
– electric control devices, boiler plants, turbines and pipe
systems in power plants
– moisture-sensitive loads etc.
Improper use
Do not place the device on flooded ground. Do not use the device
outdoors. Do not lay any objects, e.g. wet clothing, on the device
for drying. Any changes, modifications or alterations to the device
which have not been authorised by Trotec are forbidden.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with electric
devices in damp areas.
• take measures to protect themselves from direct contact with
live parts.
• have read and understood the operating manual, especially the
"Safety" chapter.
Maintenance tasks at the electrical equipment or the airconditioning technology must only be carried out by
specialist companies for cooling and air-conditioning or by
Trotec.
Residual risks
Hazardous electric current!
Work on the electrical components must only be carried
out by an authorised specialist company!
Hazardous electric current!
Before any work on the device, remove the mains plug
from the mains socket!
Caution!
To avoid damages to the device, never operate the
device without an air filter inserted!
ENOperating Manual – Dehumidifier TTK 15005
Page 8
Danger!
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Danger!
A toppling device can cause you injuries! Only slightly tilt
the device and move it carefully. If necessary, ask
another person to help. For longer distances, transport
the device with a fork lift or elevating truck. Never stand
below the device when suspended in the air.
Behaviour in the event of an emergency
1. Disconnect the device from the mains power in an emergency.
2. Do not reconnect a defective device to the mains power.
Transport
To make the device easier to transport, it is fitted with wheels and
side bar handles. If necessary, transport the device with the help
of another person. To lift the device, use a fork lift or an elevating
truck.
Before transporting the device, proceed as follows:
Storage
When out of use, store the device as follows:
•dry,
• with a roof overhead,
• in an upright position where it is protected from dust and direct
sunlight,
• with a plastic cover to protect it from invasive dust, if
necessary.
• The storage temperature is the same as the range given for the
operating temperature in the chapter "Technical data".
1. Switch off the device at the mains switch (see chapter
"Operating elements").
2. Remove the mains plug from the mains socket. Do not use the
power cable to drag the device!
3. Empty the condensation drain hose or the condensation pump
(optional). Check for dripping condensation.
4. Hold the bar handles in both hands and carefully tilt the device.
5. Transport the device on its wheels.
After transporting the device, proceed as follows:
1. Set the device in an upright position after transport.
2. Ensure that the device sits flat on the floor. The wheels are
then raised and the device cannot roll away.
6Operating Manual – Dehumid ifier TTK 1500EN
Page 9
Operation
CC
A
B
D
FAULT
DEFROST
MAINS
M/C ON
12
13
11
10
9
8
• After being switched on, the device operates fully
automatically.
• Avoid open doors and windows.
Notes regarding the dehumidifying capacity
The dehumidifying capacity depends on:
• the spatial composition of the room
• the room temperature
• the relative humidity
Positioning
When positioning the device, observe the minimum distance from
walls of other objects as described in chapter "Technical data".
• Set the device in a level and stable position.
• When positioning the device, keep a sufficient distance away
from sources of heat.
• If possible, set the device in the middle of a room. If using
multiple devices, ensure that the spaces between devices is
equal.
• When positioning the device in wet areas, secure the device
locally with an RCD (Residual Current protective Device) which
complies with the appropriate regulations.
• Ensure that extension cords are completely unrolled.
• Ensure that power supply's voltage and current comply with
the specifications on the device's nameplate.
• When using a generator, ensure that the generator supplies at
least 4 kW of power (device starting current can exceed the
nominal current by four or five times. Also note this fact when
using several devices at one generator).
The higher the room temperature and relative humidity, the higher
the dehumidifying capacity.
For using in living rooms, a relative humidity of approx. 50-60 %
is sufficient. In store rooms and archives, the humidity should not
exceed approx. 50 %.
Operating elements
No. Operating element
8Operation indicator light:
Lights when the device is switched on at the mains switch.
9"Fault" indicator light:
Lights when there is a fault.
10"Automatic defrost" indicator light:
Lights when the automatic defrost is active.
11Control on/off
12Operating hours counter
13Mains switch:
"ON": Device is switched on.
"OFF": Device is switched off.
ENOperating Manual – Dehumidifier TTK 15007
Page 10
Start procedure
A.
B.
Insert air filter
Positioning the condensation drain hose
Note:
The condensation drain hose is already installed when the device
is delivered.
1. Ensure that the condensation drain hose is properly connected
to the device and is free of damage.
2. Depending on use, position the end of the condensation drain
hose as follows:
– Position a sufficiently large container (at least 90 litres)
beside the device and insert the hose end. Check the fill level
of the container regularly.
– Position the end of the condensation drain hose above a
water drain. For larger distances, a longer hose of the same
type can also be used.
8Operating Manual – Dehumid ifier TTK 1500EN
Page 11
– The device can also be operated with a condensation pump.
16x1 mm
D
I
I
M
U
H
S
T
A
40%
30%
20%
60%
80%
OFF ON
T
OFF
ON
00000.00
D
I
I
M
U
H
S
T
A
40%
30%
20%
60%
80%
OFF
ON
T
Contact Trotec customer service if you want this alternative
version.
3. Ensure that the condensation drain hose always descends.
Switching on the device
1. Ensure that the condensation drain hose (4) has been laid and
connected properly. Do not create tripping hazards.
2. Ensure that the condensation drain hose (4) is not bent or
jammed and that there are no objects on the condensation
drain hose (4).
3. Ensure that the condensation can run off properly.
4. Insert the mains plug into a properly secured mains power
socket. Do not create tripping hazards.
5. Empty any condensation from the device by pressing the
button for draining residual water from the condensation pump
(optional).
6. Switch on the device at the mains switch (13).
"Continuous" operation mode
In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity in the air.
"Humidistat" operation mode (optional)
The device can also be operated with a humidistat.
The humidistat switches the device on or off depending on the
humidity.
If you choose to operate the device with an optional humidistat, set
the desired humidity at the humidistat (see operating manual of
the optional humidistat).
Automatic defrost
Depending on the air temperature and the relative humidity, the
evaporator fins may become covered in frost. The hot gas
automatic defrost which is installed in the device switches back on
as needed. Dehumidify mode is briefly interrupted during
defrosting.
Shut down procedure
1. Switch off the device at the mains switch (13).
2. Empty any condensation from the device by pressing the
button for draining residual water from the condensation pump
(optional).
3. Do not touch the mains plug with wet or damp hands.
4. Remove the mains plug from the mains socket.
5. Remove the condensation drain hose (4) and any residual fluid
from it.
6. Clean the device, and especially the air filter, according to
chapter "Maintenance".
7. Store the device according to chapter "Storage".
ENOperating Manual – Dehumidifier TTK 15009
Page 12
Errors and faults
The accurate functionality of the device was tested during
production a number of times. However, if functionality faults do
occur, then check the device according to the following list.
Caution!
To prevent damages to the device and to prevent the
fuse or motor protection switch from tripping, ensure
the device is switched off and wait at least 5 minutes
before switching the device back on.
The device is loud or vibrates; condensation leaks:
• Check whether the device is standing upright and on an even
surface.
The device gets very warm, is loud or is losing performance:
• Check the air inlets and air filter are not dirty. Remove external
dirt.
• Check the inside of the device for dirt (see chapter
"Maintenance"). Clean the inside of the device as described in
the chapter "Cleaning the inside with compressed air".
The device does not start:
• Check the mains power (400 V/3~/50 Hz).
• Check the mains plug for damages.
• Check whether the mains switch (13) is in the "ON" position.
• Check the fuse (home).
• If you operate the device with a humidistat, check the desired
humidity. The humidity in the room must be above the selected
range. Reduce that the selected humidity.
• Have the electrics checked by a specialist company for cooling
and air-conditioning or by Trotec.
The device runs but forms no condensation:
• Check the condensation drain hose is positioned correctly.
• Check that the condensation pump functions properly. Check
for abnormal vibrations and sounds. Remove external dirt.
• Check the room temperature. Check the device's permissible
working range complies with the technical data.
• Ensure that the relative humidity complies with the technical
data.
• If you operate the device with a humidistat, check the desired
humidity. The humidity in the room must be above the selected
range. Reduce that the selected humidity.
• Check the air filter is not dirty. If necessary, clean or replace
the air filter.
Does your device still not operate correctly after these
checks?
Bring the device to a specialist company for cooling and airconditioning or to Trotec
for repairs.
10Operating Manual – Dehumidifier TTK 1500EN
Page 13
Maintenance
Maintenance intervals
Maintenance and care intervalbefore every start
empty the condensation pump, condensation tray and/or
construction dryer
check air inlets and outlets for dirt and foreign objects
and clean if necessary
visually check whether the inside of the device is dirtyXX
clean the inside with compressed airXX
check air inlet grid and air filter for dirt and foreign
objects and clean or replace if necessary
replace air filterX
check for damagesX
check attachment screwsXX
carry out a test runX
Maintenance and care interval12345678910111213141516
check air inlets and outlets for dirt and foreign objects
and clean if necessary
clean housing
visually check whether the inside of the device is dirty
clean the inside with compressed air
check air inlet grid and air filter for dirt and foreign
objects and clean or replace if necessary
replace air filter
check for damages
check attachment screws
carry out a test run
Remarks:
1. Date:
Signature:
5. Date:
Signature:
9. Date:
Signature:
13. Date:
Signature:
2. Date:
Signature:
6. Date:
Signature:
10. Date:
Signature:
14. Date:
Signature:
3. Date:
Signature:
7. Date:
Signature:
11. Date:
Signature:
15. Date:
Signature:
4. Date:
Signature:
8. Date:
Signature:
12. Date:
Signature:
16. Date:
Signature:
ENOperating Manual – Dehumidifier TTK 150011
Page 14
Activities for before the start of maintenance
A.
50 cm
B.
C.
90°
50 cm
1. Do not touch the mains plug with wet or damp hands.
2. Before any work, detach the mains plug!
Maintenance tasks at the electrical equipment or
the air-conditioning technology must only be
carried out by specialist companies for cooling and
air-conditioning or by Trotec.
Visual check for dirt in the inside of the device
1. Remove the air filter (see chapter "Cleaning the air inlets and
the air filter").
2. Shine a torch through the opening of the device.
3. Check the inside of the device for dirt.
4. If you find dirt, use a high pressure cleaner to clean the device
according to "Cleaning the air inlets and the air filter".
5. Put the air filter back in.
Cleaning the air inlets and the air filter
12Operating Manual – Dehumidifier TTK 1500EN
Page 15
Caution!
D.
A.
B.
C.
D.
E.
After you have cleaned the device with a high pressure
cleaner, check the air filter, which you have already
removed, for damages. The corners and edges must not
be rounded or misshaped.
Before reinserting the air filter, ensure that it is dry and
is not damaged!
Read the chapter "Maintenance intervals" and replace
the air filter punctually!
Cleaning the inside with compressed air
Caution!
When cleaning the inside, take care not to bend the fins
of the condenser and evaporator. Do not damage the
insulation.
ENOperating Manual – Dehumidifier TTK 150013
Page 16
Overview and list of spare parts
Note!
The position numbers of the spare parts differ from those
describing the positions of other parts mentioned in this
operating manual.
1SD062001electrical box steel plated
5SD403950end bracket EW35 (8.5)
67140000196relay c/o 2 pole 16 A 230 V AC coil
107140000203contactor 9 A 3+1 N/O aux
117140000164delay timer 7 sec to 9 min
12SD216550fuse holder
14SD271250capacitor 8 μF
15SD072650terminal block 6 way
16SA582601loom assembly
177140000928defrost stat/timer
18SD035353fuse 1/4 x 1 1/4, 1 A
28SD035350fuse 3 A
29SD035352fuse 1/4 x 1 1/4, 7 A
ENOperating Manual – Dehumidifier TTK 150015
Page 18
Control panel
FAULT
DEFROST
MAINS
4
3
2
5
M/C ON
1
Note!
The position numbers of the spare parts differ from those
describing the positions of other parts mentioned in this
operating manual.
No.Item numberSpare part
17310001153console moulding
27141000891pilot light red rectangular 250 V
37141000889pilot light amber rectangular
47141000890pilot light white rectangular
57130000892rocker switch illuminated red
16Operating Manual – Dehumidifier TTK 1500EN
Page 19
DisposalDeclaration of conformity
In the European Union, electronic equipment must not
be treated as domestic waste, but must be disposed
of professionally in accordance with Directive 2002/
96/EC of the European Parliament and Council of 27th
January 2003 concerning old electrical and electronic equipment.
At the end of its life, please dispose of this instrument in a manner
appropriate to the relevant legal requirements.
The device uses an environmentally friendly and ozone-neutral
refrigerant (see chapter "Technical data"). Dispose of the
refrigerant/oil mixture appropriately and according to the national
regulations.
in accordance with the EC Low Voltage Directive 2006/95/EC and
the EC Directive 2004/108/EC about electromagnetic
compatibility.
Herewith, we declare that the dehumidifier TTK 1500 was
developed, constructed and produced in compliance with the
named EC directives.
Applied harmonised standards:
IEC 60335-1:2001/A2:2006
IEC 60335-2-40:2002/A1:2005
IEC 62233:2005
The marking is found on the device nameplate.
Manufacturer:
Trotec GmbH & Co. KG
Grebbener Straße 7
D-52525 Heinsberg
Phone:+49 2452 962-400
Fax:+49 2452 962-200
E-mail:info@trotec.de
Heinsberg, 30/10/2009
Managing Director: Detlef von der Lieck
ENOperating Manual – Dehumidifier TTK 150017