Trotec TTK 128 E Operating Manual

TTK 128 E
EN
OPERATING MANUAL
DEHUMIDIFIER
TRT-BA-TTK128E-TC-001-EN

Table of contents

Safety ................................................................................ 02
Information about the device.............................................. 03
Transport ........................................................................... 05
Operation........................................................................... 05
Errors and faults ................................................................ 08
Maintenance...................................................................... 09
Disposal............................................................................. 11
Declaration of conformity....................................................11

Notes regarding the operating manual

Symbols

Hazardous electric current!

Warns about hazards from electric current which can lead to injuries or even death.

Danger!

Warns of a hazard which can lead to personal injury.

Caution!

Warns of a hazard which can lead to damage to property.

Legal notice

This release replaces all previous versions. No part of this publication may be reproduced without written permission from Trotec. The same applies for electronically processing, duplicating or spreading the publication. Subject to technical changes. All rights reserved. Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer. Product names are registered. Changes to construction in the interests of constant improvements to the product, as well as changes to the shape and colour are reserved. The scope of delivery may vary from product images. This document was created with all due care. Trotec accepts no liability whatsoever for possible mistakes or omissions. © Trotec
The current version of the operating manual can be found at:
TTK 128 E
http://download.trotec.com/?sku=1120000125&id=1
1 Operating Manual – Dehumidif ier TTK 128 E EN

Safety

Carefully read this manual before starting / using the device and keep it within reach!

• Do not use the device in potentially explosive rooms. Do not use the device in aggressive atmosphere.
• The device is designed for indoor installation.
• The device must have an upward safety distance of 90 cm to all combustible materials.
• Keep away from children and animals.
• Set the device up in an upright and stable position.
• Do not expose the device to dripping water.
• Ensure that the air inlet and outlet are not obstructed.
• Ensure that the suction side is kept free of dirt and loose objects.
• Never reach or put objects into the device.
• Do not cover the device during operation.
• Do not transport the device during operation.
• Ensure that all electric cables outside of the device are protected from damage (e.g. from animals).
• Only use extensions to the connecting cable which are appropriate to the device power consumption, the length of its cable and its use. Avoid electrical overload.
• Only transport the device in an upright position with an emptied condensation tank.
• Dispose of the collected condensation. Do not drink it. Health hazard!

Intended use

Use the device TTK 128 E only for drying and dehumidifying room air, while adhering to and following the technical data.

Intended use comprises:

• drying and dehumidifying: – living rooms, bedrooms or basements – laundries, holiday homes.
• maintaining the dryness of: – storage spaces, archives, laboratories, museums, garages – changing rooms etc.

Improper use

Do not place the device TTK 128 E on wet or flooded ground. Do not use the device outdoors. Do not lay any objects, e.g. wet clothing, on the device for drying. Any unauthorised changes, modifications or alterations to the device are forbidden.

Personnel qualifications

People who use this device must:
• be aware of the dangers that occur when working with electric devices in damp areas.
• have read and understood the operating manual, especially the Safety chapter.

Residual risks

Hazardous electric current!

Work on the electrical components must only be carried out by an authorised specialist company!

Hazardous electric current!

Before any work on the device, remove the mains plug from the mains socket!

Danger!

The device is not a toy and does not belong in the hands of children!

Danger!

Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!

Danger!

Do not leave the packaging lying around. Children may use it as a dangerous toy.

Caution!

To avoid damages to the device, never operate the device without an air filter inserted!

Behaviour in the event of an emergency

1. Disconnect the device from the mains power in an emergency.
2. Do not reconnect a defective device to the mains power.
EN Operating Manual – Dehumidif ier TTK 128 E 2

Information about the device

Device description

This device TTK 128 E uses the principle of condensation to automatically dehumidify rooms. The fan sucks damp room air through the air inlet (5), the air filter, the evaporator and to the condenser located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator fins as either condensation or frost. At the condenser the dehumidified, cooled air is warmed by a few degrees and blown out. The drier air thus conditioned mixes with the air in the room. The humidity in the room where the device is positioned is reduced as air constantly circulates through the device. Depending on the air temperature and the relative humidity, the condensed water either drops continuously or only during the defrost phase through the integrated drain nozzle into the condensation tank (7) below. It is fitted with a float to measure the filling level. The device has a control panel (1) for operating and controlling the functions. Once the maximum fill level of the condensation tank (7) is reached, the condensation tank indicator light (see chapter Operating elements) on the control panel (1) is illuminated. The device switches off. The condensation tank indicator light only goes out again once the emptied condensation tank (7) is reinserted. The condensed water can be diverted by attaching a hose at the condensation connection (6). The device can reduce the relative humidity of a room by up to approx. 30 %. Because of the heat radiation generated during operation, the room temperature may rise slightly.

Device depiction

No. Operating element
1 control panel 2 air outlet (shut, open prior to start-up) 3 lateral carrying handles 4front 5 air inlet at the rear 6 hose connection for the condensate outlet 7 condensation tank
3 Operating Manual – Dehumidif ier TTK 128 E EN
Technical data
Parameter Value
Model TTK 128 E Dehumidifying capacity, max. 55 l / 24 h Dehumidification performance @ 30 °C and 80 % RH 50 l / 24 h Operating temperature 5 to 32 °C Operating range relative humidity 30 to 90 % Air flow rate, max. 380 m³/h Mains connection 1/N/PE~ 230 V 50 Hz Power consumption (acc. to EN 60335) 1150 W Nominal current 5.1 A Condensation tank 7.2 l Refrigerant R410A Amount of refrigerant 515 g Weight 23.0 kg Dimensions (height x depth x width) 628 x 286 x 481 (mm) Minimum distance to walls or other objects A: Top: 50 cm
B: Rear: 50 cm C: Side: 50 cm D: Front: 50 cm
Sound pressure level LpA (1 m; complies with DIN 45635-01-KL3) 58 dB (A)
Wiring diagram
EN Operating Manual – Dehumidif ier TTK 128 E 4
Loading...