TTK 120 E / TTK 122 E
TRT-BA-TTK120E_122E-TC-001-EN
EN
OPERATING MANUAL
DEHUMIDIFIER

Table of contents
Notes regarding the operating manual .................. 01
Information about the device ................................ 02
Safety................................................................... 06
Transport.............................................................. 07
Operation ............................................................. 07
Errors and faults................................................... 12
Maintenance......................................................... 13
Disposal ............................................................... 16
Declaration of conformity...................................... 16
Notes regarding the operating manual
Symbols
Hazardous electric current!
Warns about hazards from electric current which can lead to injuries or even
th.
dea
Danger!
Warns of a hazard which can lead to personal injury.
Caution!
Warns of a hazard which can lead to
damage to property.
Legal notice
This release replaces all previous releases. No part of
this publication may be reproduced without written
permission. The same applies for electronically processing, duplicating or spreading the publication.
bject to technical changes. All rights reserved.
Su
Trademarks are used without guarantee that they may
be used freely and primarily following the spelling of
the manufacturer. The product names used are registered and should be treated appropriately. Scope of
very may vary from product images. This docu-
deli
ment was produced with all due care. We accept no
iab
ility whatsoever for mistakes or omissions.
l
© TROTEC
®
The current version of the operating manual can be
und at: www.trotec.de
fo
1 Operating Manual – Dehum idifier TTK 120/122 E EN

Information about the device
Description of the device
This device uses the principle of condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet (6),
e a
ir filter (4), the evaporator and to the condenser
th
located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator
fins as either condensation or frost. The dehumidified,
cooled air is rewarmed at the condenser and blown
out at a temperature of approx. 5 °C above room temperature. The drier air which is prepared in this way
es
with the air in the room. The humidity in the
mix
room where the device is positioned is reduced as air
constantly circulates through the device. Depending
on the air temperature and the relative humidity, the
condensed water either drops continuously or only
during the defrost phase into the condensation tray
and through the integrated drain nozzle into the condensation tank (5) below. This is fitted with a float to
s
ure the fill level. The device has a control
mea
panel (7) for operating and controlling the functions.
n
ce the maximum filling level of the condensation
O
tank (5) is reached, symbol (12) (condensation tank
full) on the control panel (7) lights up. The device
ches off. The light of symbol (12) (condensation
swit
tan
k full) only goes out again once the emptied condensation tank (5) is reinserted. Optionally, the condensed water can be drained by attaching a hose to
condensation plug (inside the housing, above the
the
condensation tank). The device can reduce the relative humidity of a room by up to
vides additional assistance for drying wet washing or
ing in living or working spaces. Because of the
cloth
heat radiation which is tied up in operation, the room
temperature can rise by approx. 1 – 4 °C.
approx. 40 %. It pro-
Device depiction
No. Operating element
1 handles
2 wheels
3 air outlet
4 air filter
5 condensation tank
6 air inlet
7 control panel
EN Operating Manual – Dehumidifier TTK 120/122 E 2

Technical data
Parame ter
Dehumidifying capacity, max. 30 l / 24 h 40 l / 24 h
Operating temperature 9-35 °C 9-35 °C
Operating range for relative humidity 40-100 % 40-100 %
Air flow rate, max. 340 m³/h 350 m³/h
Electric connection 230 V / 50 Hz 230 V / 50 Hz
Power input, max. 0.6 kW 0.7 kW
Fuse (home) 10 A 10 A
Condensation tank 10 l 10 l
Cooling agent R134a R134a
Amount of cooling agent 260 g 330 g
Weight 22.3 kg 22.9 kg
Dimensions (HxDxW) 650 x 310 x 435 mm 650 x 310 x 435 mm
Minimum distance from walls of other objects A: Behind: 50 cm
Sound pressure level LpA (1 m; complies with DIN 45635-01-KL3) 47 dB(A) 49 dB(A)
Value
TTK 120 E TTK 122 E
B: Front: 50 cm
A: Behind: 50 cm
B: Front: 50 cm
3 Operating Manual – Dehum idifier TTK 120/122 E EN

Circuit diagram – TTK 120 E
Marking Meaning
A1 electronic card (power)
A2 humidity/temperature sensor card
A3 electronic card (control)
B1 humidity/temperature sensor
B2 evaporator sensor
F1 compressor thermal cutout
RY102 compressor relay
RY104 fan relay
M1 motor-driven compressor
M2 fan
S1 tank full microswitch
S2 tray presence microswitch
S301 signal key for the humidity/room temperature detected
S302 desired humidity decrease key
S303 desired humidity increase key
S304 switch-on/stand-by key
S305 operating mode selection key
T1 transformer
Z1 compressor capacitor
EN O perating Manual – Dehumi difier TTK 120/122 E 4

Circuit diagram – TTK 122 E
Marking Meaning
A1 electronic card (power)
A2 humidity/temperature sensor card
A3 electronic card (control)
B1 humidity/temperature sensor
B2 evaporator sensor
F1 compressor thermal cutout
P1 bypass valve coil
RY101 bypass valve coil relay
RY102 compressor relay
RY104 fan relay
M1 motor-driven compressor
M2 fan
S1 tank full microswitch
S2 tray presence microswitch
S301 signal key for the humidity/room temperature detected
S302 desired humidity decrease key
S303 desired humidity increase key
S304 switch-on/stand-by key
S305 operating mode selection key
T1 transformer
X1 2-pole connector
Z1 compressor capacitor
5 Operating Manual – Dehum idifier TTK 120/122 E EN