Trotec TTK 110 HEPA Operating Manual

Page 1
TTK 110 HEPA
EN
OPERATING MANUAL
DEHUMIDIFIER
TRT-BA-TTK110HEPA-TC-002-EN
Page 2

Table of contents

You can download the current version of the operating manual and the EU declaration of conformity via the following link:

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Notice
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
TTK 110 HEPA
https://hub.trotec.com/?id=39663

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Let the device dry out after a wet clean. Do not operate it when wet.
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
Do not sit on the device.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
1 EN
Operating manual – dehumidifier TTK 110 HEPA
Page 3
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk.
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
Ensure that the air inlet and outlet are not obstructed.
Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects.
Only transport the device in an upright position with an emptied condensation tank or drain hose.
Discharge the collected condensate before transport and storage. Do not drink it. Health hazard!

Intended use

Use the device for dehumidifying, drying and cleaning indoor air, while adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry.
Intended use comprises:
dehumidifying, drying and cleaning the air in: – living rooms, bedrooms, bathrooms or basements
– laundries, holiday homes, camper vans, boats
maintaining the dryness of: – storage spaces, archives, laboratories, garages
– bathrooms, wash rooms, changing rooms etc.

Improper use

Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability and guarantee null and void.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with
electric devices in damp areas.
have read and understood the operating manual, especially
the Safety chapter.
Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.
EN 2
Operating manual – dehumidifier TTK 110 HEPA
Page 4

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Notice
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

Behaviour in the event of an emergency

1. In an emergency, disconnect the device from the mains feed-in: Switch the device off and disconnect the power cable from the mains socket. Hold onto the mains plug while doing so.
2. Do not reconnect a defective device to the mains.

Information about the device

Description of the device

The device has a function for air purification that is active in powerful dehumidification, automatic and laundry drying mode and enables HEPA air purification with an efficiency of 99.97 %, thus filtering out pollen, viruses, dust mite residue, mould fungus spores and other allergens.
Moreover, the device has an ionisation function that can be switched on in addition. The released ions remove pollen, dust, viruses and bacteria from the room air. Thanks to this air purification method, the quality of the room air can be additionally improved.
Another feature is the device's self-cleaning function. This function serves to dry the interior of the device in order to prevent the formation of mould or similar inside the device due to residual moisture.
The device uses the principle of condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter, the evaporator and to the condenser located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime. The dehumidified, cooled air is slightly warmed at the condenser and blown out again. The drier air thus conditioned mixes with the air in the room. The humidity in the room where the device is positioned is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the condensed water either drops continuously or only during the defrost phase through the integrated drain nozzle into the condensation tank below. It is fitted with a float to measure the filling level.
The device has a control panel for operating and controlling the functions.
Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not installed correctly, the condensation tank indicator light (see chapter Operating elements) on the control panel is illuminated. The device switches off. The condensation tank indicator light only goes out again once the emptied condensation tank is reinserted.
Optionally, the condensed water can be drained by attaching a hose at the condensation connection.
The device can reduce the relative humidity of a room to approx. 40%.
The device provides additional assistance for drying wet laundry or clothing in living or working spaces.
Because of the heat radiation generated during operation, the room temperature may rise slightly.
3 EN
Operating manual – dehumidifier TTK 110 HEPA
Page 5

Device depiction

1
2
3
4
5
7
8
9
10
6

Transport and storage

Transport

Before transporting the device, proceed as follows:
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
To make the device easier to transport, it is fitted with wheels.
Do not use the power cable to drag the device.
Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
Set up the device in an upright position after transport.
Leave the device to rest for 12-24hours, so the refrigerant can accumulate within the compressor. Wait 12-24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.
No. Designation
1 Control panel 2 Air inlet (behind cover) 3 Condensation drain hose connection 4 Air filter 5 HEPA filter 6 Condensation drain hose 7 Condensation tank with filling level indicator 8 Air outlet 9 Transport handle 10 Wheels

Storage

Before storing the device, proceed as follows:
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
Empty and clean the condensation tank prior to storage.
Carry out the self-cleaning function to prevent the formation of moisture within the device during a longer period of non-use.
When the device is not being used, observe the following storage conditions:
dry and protected from frost and heat
in an upright position where it is protected from dust and direct sunlight
with a cover to protect it from invasive dust if necessary
Place no further devices or objects on top of the device to prevent it from being damaged.
EN 4
Operating manual – dehumidifier TTK 110 HEPA
Page 6

Assembly and installation

A
B
C
C
D

Scope of delivery

Device
Condensation drain hose, length: 1.0 m, diameter: 9 mm
Air filter
HEPA filter
Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.

Start-up

When positioning the device, observe the minimum distance from walls or other objects as described in chapter Technical Data.
When positioning the device, keep a sufficient distance to heat sources.
Make sure that no curtains or other objects interfere with the air flow.
When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations.
Inserting the air filter
Notice
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
Make sure that the air filter is installed before switching the device on.
Inserting the condensation tank
Ensure that the float inside the condensation tank is inserted correctly.
Ensure that the condensation tank is empty and inserted correctly.
Connecting the power cable
Insert the mains plug into a properly secured mains
Before restarting the device, check the condition of the
socket.
power cable. If there are doubts as to the sound condition, contact the customer service.
Set the device up in an upright and stable position.
Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges.
Make sure that extension cables are completely unrolled.
5 EN
Operating manual – dehumidifier TTK 110 HEPA
Page 7

Operation

%
HUMIDITY
TIMER
SWING
POWER
MODE
SLEEP
IONIZER DRYING
AUTO
%
°F
°C
ON
OFF
DAY
OK
NO
12 13 14 15 16 19 2018 2111
22
23
24
17
25262728293031
32
33
34
Notes:
Avoid open doors and windows.
After being switched on, the device operates fully automatically.
The fan permanently runs in automatic mode even after the set nominal value has been reached until the device is switched off.
Operating elements
No. Designation Meaning
11 Condensation tank full
indication
12 Automatic indication Automatic mode is active 13 Powerful
dehumidification
indication
14 Humidity level
indication
15 Laundry drying
function indication
16 Child lock indication Child lock is active 17 Air purification
indication
Flashes when the condensation tank is full, see chapter Emptying the condensation tank
Continuous operation is active
Indicates the current room humidity Indicates the desired relative room humidity during setting Indicates the error code in the event of a fault:
EF (motor fault)
E1 (fault at temperature sensor)
E2 (fault at humidity sensor)
E3 (fault at coil sensor)
Laundry drying mode is active
Air purification mode is active
(Only possible when HEPA filter is used)
No. Designation Meaning
18 Temperature and timer
indication
Indicates the current room temperature Indicates the number of hours of the activated timer ON is displayed if the timer for automatic switch-on is active OFF is displayed if the timer for
automatic switch-off is active 19 Ventilation indication Ventilation mode is active 20 Self-cleaning function
Self-cleaning mode is active
indication
21 Filter indication OK and full grid box: HEPA filter is
inserted
NO and empty grid box: HEPA
filter is not inserted 22 POWER button On/Off button:
Switches the device on or off 23 MODE button Selection button for operating
modes:
Automatic mode
Powerful dehumidification
(continuous operation)
Laundry drying function
Air purification
Ventilation
24 SLEEP button Switches night mode on or off 25 Filter usage indication Indicates the operating life of the
HEPA filter:
Day indication: Number of days in the segment display of the filter usage indication
Hour indication: 1asterisk corresponds to 4hours, max. 6asterisks = 24hours
26 Night mode indication Is indicated in night mode 27 DRYING button Switching on the self-cleaning
function
28 Fan speed indication Dynamic display for the fan speed:
turning slowly = low fan speed turning quickly = high fan speed Dynamic display for the swing function: Vertical bar moves from left to right
29 IONIZER button Activates additional air purification
by ionisation (only possible when the HEPA filter is installed)
30 Ionisation indication Air purification by ionisation is
indicated (only possible when the HEPA filter is installed)
EN 6
Operating manual – dehumidifier TTK 110 HEPA
Page 8
No. Designation Meaning
31 Low ambient
temperature indication
Is displayed at ambient temperatures between 5°C and 15°C Flashes at ambient temperatures below 5°C
32 SWING button Switches the automatic movement
of the ventilation flap on or off
33 TIMER button Switches the timer function on or
off Selection button for number of hours, value range between 1 and 24h The temperature and timer indication(18) displays ON for automatic switch-on or OFF for automatic switch-off
34 HUMIDITY button Selection button for the relative
humidity (40% to 70% in steps of 5%) Setting the fan speed in air purification and ventilation mode (low or high)
Switching the device on
Once you have completely installed the device as described in the Start-up chapter, you can switch it on.
1. Press the POWER button(22). ð When used for the first time, the device starts in
automatic mode.
ð If the device was previously used, it will start in the last
selected operating mode upon switch-on.
Setting the operating mode
Setting the relative room humidity
In automatic mode, you can modify the relative room humidity at all times.
1. Press the HUMIDITY button(34) to set the desired room
humidity. Setting is possible in the range between 40 % and 70 % in steps of 5%.
ð The desired room humidity is indicated in the display for the
current room humidity(14) for approx.5s. Then the current relative room humidity is displayed again.
Automatic mode
The humidity level can be set (see Setting the relative room humidity).
The fan runs at low speed. The fan speed cannot be changed. The compressor switches off automatically once the desired
relative room humidity has been reached. The fan keeps running.
1. Press the MODE button(23) until the indication for automatic mode(12) appears on the display.
2. Press the HUMIDITY button(34) to set the desired relative humidity. Setting is possible in the range between 40 % and 70 % in steps of 5%.
ð The desired humidity is indicated in the display for the
humidity level(14) for approx.5s. Then the current relative room humidity is displayed again.
Powerful dehumidification (continuous operation)
The device dehumidifies the air constantly and regardless of the room humidity.
The fan operation depends on the room humidity: If the room humidity is high, the fan runs at high speed. If the room humidity is low, the fan regulates its speed to a low level.
The relative humidity cannot be adjusted in this operating mode.
1. Press the MODE button(23) until the indication for powerful dehumidification(13) appears on the display.
Info
For continuous operation a condensation drain hose can be connected in order to continuously drain the accumulating condensate.
Laundry drying function
The device may be used to dry clothes in a more timely manner. When positioning the device or a clothes horse, please observe the minimum distances specified in the technical data.
The device dehumidifies the air constantly and regardless of the room humidity.
The relative humidity cannot be adjusted in this operating mode. The fan runs at the highest speed. Additionally, the swing
function switches on. The swing function remains activated even if the operating mode is changed.
1. Press the MODE button(23) until the indication for the laundry drying function(15) appears on the display.
7 EN
Operating manual – dehumidifier TTK 110 HEPA
Page 9
Air purification
The fan guides the air through the inserted HEPA filter. The HEPA filter filters particles from a size of 20nanometres out of the air, thus removing dust and smoke particles, bacteria, allergens and some viruses. This guarantees fresh room air for 8hours.
If the air purification function is activated, the fan starts running too so that the air is cleaned by the HEPA filter. Consequently, clean air is blown into the room.
To maintain a constantly high filtering effect, the HEPA filter should be replaced after one year at the latest, or sooner if required.
ü The HEPA filter is installed. ü The grid box of the filter indication(21) is filled and OK is
displayed.
1. Press the MODE button(23) until the air purification indication(17) appears on the display.
2. Press the HUMIDITY button(34) to select low or high fan speed.
Info
If a HEPA filter is installed, air purification is performed in addition to dehumidification in automatic, powerful
dehumidification and laundry drying mode. The air purification indication(17) flashes at regular intervals
to indicate simultaneous air purification.
Self-cleaning function / Internal drying
This function serves to dry the interior of the device in order to prevent the formation of mould or similar inside the device due to residual moisture.
The self-cleaning function should be used if the device is not operated or is stored for a longer period of time.
Self-cleaning takes approx.1hour. First, the inside of the device is dehumidified at a high fan speed for approx.30minutes. Then, another internal dehumidification process takes place for approx.10minutes, during which the air is blown out at a wide angle. During the last 15minutes, the inside of the device is dehumidified again at a high fan speed.
1. Press the DRYING button(27) for approx. 2 seconds.
2. To switch off the function, press the DRYING button(27) for approx.2seconds once again. The device switches back to the previous mode. By pressing the POWER button(22), the self-cleaning function is stopped and the device switches over to standby mode.
Ionisation
With this function, the room air is not only cleaned by means of the HEPA filter, but additionally by means of ions. The released ions remove pollen, dust, viruses and bacteria from the room air.
1. Press the IONIZER button(29) to start the ionisation.
ð The ionisation indication(30) appears on the display.
Ventilation
In ventilation mode you can choose between low and high fan speed.
Info
Before selecting this operating mode, remove the HEPA filter from the device (see Changing the HEPA filter). The HEPA filter is not required for this operating mode and its lifetime can be increased this way. If you do not remove the HEPA filter, the filter indication(21) flashes.
1. Press the MODE button(23) until the indication for the ventilation indication(19) appears on the display.
2. Press the HUMIDITY button(34) to select low or high fan speed.
Night mode
Night mode can be switched on in all operating modes. When the operating mode is changed, night mode remains active.
In night mode, the device runs with a low fan speed.
1. Press the SLEEP button(24) to switch night mode on or off.
Info
This function can only be used if a HEPA filter is installed.
EN 8
Operating manual – dehumidifier TTK 110 HEPA
Page 10
Setting the timer
The timer can be set in all operating modes. The timer has two modes of operation:
automatic switch-on upon expiry of a preset number of hours.
automatic switch-off upon expiry of a preset number of hours.
The number of hours can range from 1 to 24 and can be adjusted in increments of 1h.
Notice
Do not leave the operating device unattended in a freely accessible room with an activated timer.
Automatic switch-on
1. Switch off the device.
2. Press the TIMER button(33) several times until the desired number of hours is displayed on the temperature and timer indication(18).
ð The number of hours flashes on the temperature and
timer indication(18).
3. Wait for approx. 5seconds in order to save the setting.
4. Press the MODE button(23) to select the operating mode in which the device shall start up.
ð The characters ON and the number of hours left until
switch-on appear on the temperature and timer indication(18).
ð The timer setting equals the desired number of hours. ð The device starts in the previously selected operating mode
after the set time has elapsed.
Notes regarding automatic switch-on:
Pressing the POWER button(22) deactivates the automatic switch-on function.
Automatic switch-off
ü The device is switched on.
1. Press the TIMER button(33) several times until the desired number of hours is displayed on the temperature and timer indication(18).
ð The number of hours flashes on the temperature and
timer indication(18).
2. Wait for approx. 5seconds in order to save the setting.
ð The characters OFF and the number of hours left until
switch-off appear on the temperature and timer indication(18).
ð The timer setting equals the desired number of hours. ð The device switches off after the set period of time.
Memory function
During short power failures, the device memorizes the programmed nominal value for the humidity level, the timer and the operating mode setting.
Auto stop function
If the water tank is full, not inserted correctly or the set room humidity has been reached, the device will stop automatically.
Child lock
The child lock can be activated both during operation and in standby mode.
1. Press the MODE button(23) for approx. 2 seconds.
ð The child lock is activated. ð The child lock indication(16) appears on the display.
2. Press the MODE button(23) for approx. 2 seconds once again.
ð The child lock is deactivated. ð The child lock indication(16) disappears.
Swing function
Using the swing function, you can adjust the position of the ventilation flap or activate continuous movement of the ventilation flap. This enables an even distribution of the air current in the room.
The swing function can be switched on and off regardless of the operating modes. The setting is maintained even if the operating mode is changed.
1. Press the SWING button(32).
ð The ventilation flap moves up and down continuously.
2. Press the SWING button(32) again to stop the ventilation flap in a certain position and to switch off the swing function.
Changing the unit °C / °F
The temperature in the temperature and timer indication(18) can be indicated in °C or °F.
Please proceed as follows to change the temperature unit:
1. Simultaneously press the TIMER(33) and HUMIDITY(34) buttons.
ð The displayed temperature is converted to the other
unit.
9 EN
Operating manual – dehumidifier TTK 110 HEPA
Page 11
Operation with hose attached to the condensation
35
37 36
37
connection
For continuous operation or unattended dehumidification, please connect the supplied condensation drain hose to the device.
ü A suitable hose (diameter = 9mm) is ready for use.
1. Switch off the device.
2. Break out the cover(35) with a suitable tool(e.g. a screwdriver).
5. With the other hand, push one end of the hose onto the hose connection(37).
3. Take the condensation tank out of the device.
4. With one hand, push the fastener(36) at the hose connection(37) to the rear and hold the fastener(36) in this position. The fastener(36) is fitted with a spring and closes when released.
6. Let go of the fastener(36).
7. Refit the condensation tank into the device. Make sure not to damage the float when inserting or removing the condensation tank. In doing so, make sure that the float is positioned correctly. In doing so, make sure that the condensation tank is inserted correctly, for otherwise the device cannot be switched back on.
8. Guide the other hose end to a suitable drain or sufficiently dimensioned collection container. Please note that the hose must not be kinked.
Remove the hose if you want to collect the condensate in the condensation tank again. Allow the hose to dry prior to storage. The hose can be connected in any operating mode for continuous operation.
EN 10
Operating manual – dehumidifier TTK 110 HEPA
Page 12
Automatic defrost
At low ambient temperatures, ice may form at the evaporator during dehumidification. The device will then carry out an automatic defrost. Dehumidification is briefly interrupted during defrosting.
The duration of the defrost process can vary. Do not switch off the device during automatic defrost. Do not remove the mains plug from the mains socket.
The low ambient temperature indication(31) flashes during defrosting.
Drying laundry
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry.
For drying laundry the following values should be selected:
cupboard dry = 46 % relative humidity
iron dry = 58 % relative humidity
slightly dried = 65 % relative humidity
If necessary, use a measuring device to determine the humidity level.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
If necessary, remove the condensation drain hose and any residual fluid from it.
Empty the condensation tank, if need be.
If necessary, carry out self-cleaning (see Self-cleaning function).
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.

Available accessories

Warning
Only use accessories and additional equipment specified in the operating manual. Using insertion tools or accessories other than those specified in the operating manual may cause a risk of injury.
Accessories Article number
HEPA filter 7.710.000.835 Carbon filter 7.710.000.836

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Check the filling level of the condensation tank and empty it if necessary. The condensation tank full indication(11) must not be displayed.
Check the condensation tank for correct seating.
Check whether the low ambient temperature indication(31) flashes on the display. Possibly, the device does not start because the ambient temperature is too low (< 5°C).
Wait for 10minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec.
The device is running, but no condensate forms:
Check the float in the condensation tank for dirt. If necessary, clean the condensation tank. The float must be able to move freely.
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Ensure that the relative room humidity complies with the technical data.
Check the preselected desired room humidity level. The relative humidity in the room must be above the selected range. If necessary, reduce the preselected desired room humidity.
Check the air filter for dirt. If necessary, clean or replace the air filter.
Check whether the low ambient temperature indication(31) flashes on the display. Possibly, the device does not start because the ambient temperature is too low (< 5°C).
From the outside, check the condenser for dirt (see chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright position.
Condensate is leaking:
Check the device for leaks.
11 EN
Operating manual – dehumidifier TTK 110 HEPA
Page 13
The compressor does not start:
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Ensure that the relative room humidity complies with the technical data.
Check the preselected desired room humidity level. The relative humidity in the room must be above the selected range. If necessary, reduce the preselected desired room humidity.
Check whether the low ambient temperature indication(31) flashes on the display. Possibly, the device does not start because the ambient temperature is too low (< 5°C).
Check whether the overheating protection of the compressor has tripped. Disconnect the device from the mains and let it cool down for approx. 10minutes before reconnecting it.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
The fan does not start:
Check the operating mode. If the device is in air purification mode and the HEPA filter is not inserted, the
fan will not start. Insert the HEPA filter in air purification mode (see Replacing the HEPA filter).

Error codes

The following error codes can be displayed:
Error code Cause Remedy
EF Motor fault Disconnect the device E1 Fault at temperature
sensor
E2 Fault at humidity
sensor
E2 Fault at coil sensor
briefly from the mains. Should the error still be displayed after the restart, please contact the customer service.
The device gets very warm, is loud or loses power:
Check the air inlets and air filters for dirt. Remove external dirt.
From the outside, check the device for dirt (see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company for cooling and air­conditioning or by Trotec.
Note:
Wait for at least 3 minutes after maintenance and repair work. Only then switch the device back on.
Your device still does not operate correctly after these checks?
Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair.
EN 12
Operating manual – dehumidifier TTK 110 HEPA
Page 14

Maintenance

Maintenance intervals

Maintenance and care interval before every
start-up
Empty the condensation tank and drain hose Check the air inlets and outlets for dirt and
X X
foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects
X X
and clean or replace if necessary Replace the air filter Check the HEPA filter for dirt and foreign
objects and clean or replace if necessary Replace the HEPA filter Check for damage
X
Check the attachment screws Test run
as needed at least
every 2 weeks
X
X X
X X
X
X
X
X X
at least every 4 weeks
at least every 6 months
at least annually
X
13 EN
Operating manual – dehumidifier TTK 110 HEPA
Page 15

Maintenance and care log

Device type: .............................................
Device number: ....................................
Maintenance and care interval
Empty the condensation tank and drain hose
Check the air inlets and outlets for dirt and foreign objects and clean if necessary
Clean the exterior Visually check the inside of the
device for dirt Check the air filter for dirt and
foreign objects and clean or replace if necessary
Replace the air filter Check the HEPA filter for dirt and
foreign objects and clean or replace if necessary
Replace the HEPA filter Check for damage Check the attachment screws Test run Remarks:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1. Date: ................................
Signature: ............................
5. Date: ................................
Signature: ............................
9. Date: ................................
Signature: ............................
13. Date: ..............................
Signature: ............................
2. Date: ................................
Signature: ............................
6. Date: ................................
Signature: ............................
10. Date: ..............................
Signature: ............................
14. Date: ..............................
Signature: ............................
3. Date: ................................
Signature: ............................
7. Date: ................................
Signature: ............................
11. Date: ..............................
Signature: ............................
15. Date: ..............................
Signature: ............................
4. Date: ................................
Signature: ............................
8. Date: ................................
Signature: ............................
12. Date: ..............................
Signature: ............................
16. Date: ..............................
Signature: ............................
EN 14
Operating manual – dehumidifier TTK 110 HEPA
Page 16

Activities required before starting maintenance

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec.

Cleaning the housing

Clean the device with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air­conditioning or by Trotec.
5. Put the air filter back in.

Replacing the HEPA filter

The HEPA filter should be replaced in case of heavy soiling. The operating life is approx.1year, depending on the degree of
air pollution. If required, visually inspect the HEPA filter for dirt. The HEPA filter's current time of usage is displayed on the filter
usage indication(25):
Day indication: Number of days on the filter usage indication(25)
Hour indication: 1asterisk corresponds to 4hours, max. 6asterisks = 24hours
1. Remove the HEPA filter from the device.
2. Dispose of the used HEPA filter according to the national regulations.
3. Reset the internal counter for the filter usage by pressing a small, pointed object (e.g. a piece of wire of a paper clip) into the opening shown in the figure below.
ð An acoustic signal is emitted as confirmation. ð The filter usage indication(25) is reset to 0.

Refrigerant circuit

The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air­conditioning or by Trotec.
15 EN
Operating manual – dehumidifier TTK 110 HEPA
Page 17
4. Insert the new HEPA filter into the device.

Cleaning the air filter

2. Clean the filter using a slightly damp, soft, lint-free cloth. If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent.
Notice
Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be deformed or rounded. Before reinserting the air filter, make sure that it is undamaged and dry!
The air filter has to be cleaned as soon as it is dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults).
1. Remove the air filter from the device.
3. Allow the filter to dry completely. Do not insert a wet filter into the device!
4. Reinsert the air filter into the device.
EN 16
Operating manual – dehumidifier TTK 110 HEPA
Page 18

Emptying the condensation tank

Once the condensation tank is full, the device stops dehumidification operation and switches itself off.
1. Take the condensation tank out of the device.
4. Refit the condensation tank into the device. Make sure not to damage the float when inserting or removing the condensation tank. In doing so, make sure that the float is positioned correctly. In doing so, make sure that the condensation tank is inserted correctly, for otherwise the device cannot be switched back on.
2. Empty the condensation tank over a drain or sink.
3. Rinse the tank with clear water. Clean the tank regularly using a mild cleaning agent (no detergent!).

Activities required after maintenance

If you want to continue using the device:
Leave the device to rest for 12-24hours, so the refrigerant can accumulate within the compressor. Wait 12-24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
Store the device according to the Storage chapter.
17 EN
Operating manual – dehumidifier TTK 110 HEPA
Page 19

Technical annex

M
Plug
transformer
MOTOR
Capacitor
L
N
Water Switch
IONIZER
S
C
R
CM
Receiver &Display
BN:brown BU:blue BK:black RD:red WH:white YE/GN:yellow/green
Coil Sensor
Step motor
MAIN P.C.B
Room Temp Sensor
BN
BU
YE/GN(GN)
YE/GN(GN)
RD
Capacitor
BU
BU
BN
RD
BK
RD
BK
WH
BU
BU
BN
WH
BK
ELECTRIC CIRCUIT DIAGRAM
YDH
CN1
CN9
PH
CN4
CN5
PG
Water
RT1
RD
W
H
B
U
Photodiode
Photodiode

Technical data

Parameter Value
Model TTK 110 HEPA
Room size for dehumidification function
Room size for air purification function (HEPA)
Max. dehumidification performance
Dehumidifying capacity @ 30°C and 80%RH
Air volume 260 m3/h Ambient temperature 5°C to 32°C Operating range relative
humidity Power supply CEE 7/7 Power input 0.52 kW Nominal current 2.3 A Refrigerant R134a Amount of refrigerant 320 g GWP factor 1430 CO2 equivalent 0.46t Suction side pressure 0.5MPa Discharge side pressure 1.5MPa Condensation tank 6 l Sound pressure level
(1m distance) Dimensions
(length x width x height) Minimum distance to walls and
other objects
A: top: B: rear: C: side:
D: front:
Weight 18 kg
EN 18
120 m²/ 300 m³
35 m² / 87.5 m³
40 l / 24 h
35 l / 24 h
30 % to 95 % RH
46 dB (A)
265 x 410 x 665 (mm)
50 cm 30 cm 30 cm 30 cm
Wiring diagram

Disposal

The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
The device is operated with fluorinated greenhouse gas which can be dangerous for the environment and contribute to global warming when emitted to the atmosphere.
Further information is provided on the nameplate. Dispose of the refrigerant appropriately and according to the
national regulations.
Operating manual – dehumidifier TTK 110 HEPA
Page 20
Trotec GmbH & Co. KG
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400 +49 2452 962-200
info@trotec.com www.trotec.com
Loading...