You can download the current version of the operating manual and the EU declaration of conformity via the following link:

Notes regarding the operating manual

Symbols

Danger
This symbol indicates dangers to the life and health of persons due to extremely flammable gas.
Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
TTK 100 E
https://hub.trotec.com/?id=40316

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use.
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms or areas and do not install it there.
Do not use the device in aggressive atmosphere.
Only put up the device in an upright, stable position on firm ground.
Let the device dry out after a wet clean. Do not operate it when wet.
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
Do not sit on the device.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
2 EN
dehumidifier TTK 100 E
Page 3
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk!
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
Make sure that the air inlet and outlet are not obstructed.
Make sure that the suction side is kept free of dirt and loose objects.
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
Only transport the device in an upright position with an emptied condensation tank or drain hose.
Discharge the collected condensate before transport and storage. Do not drink it. Health hazard!
Only install, operate and store the device TTK 100 E in a room measuring more than 4m2.
Store the device in a way that no mechanical damage can occur.
Please note that the connected pipelines must not contain any sources of ignition.
R290 is a refrigerant that complies with European environmental regulations. No part of the cooling circuit may be perforated.
Observe the maximum refrigerant capacity in the technical data.
Do not drill through or burn.
Do not use any means other than those recommended by the manufacturer for accelerating the defrosting process.
Every person working with or at the refrigerant circuit must be able to provide a certificate of qualification issued by a body accredited by the industry, demonstrating their competence in the safe use of refrigerants based on a procedure well-known in the industry.
Service work may only be carried out in accordance with the manufacturer's specifications. If maintenance and repair work require the support of additional persons, the person trained in handling flammable refrigerants shall continuously supervise the work carried out.
Unventilated rooms, in which the device is installed, operated or stored, must be built in a way to ensure that potentially leaking refrigerant cannot accumulate. This serves to avoid fire or explosion hazards resulting from an ignition of the refrigerant by an electric furnace, cooking stove or another ignition source.
The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air­conditioning or by Trotec.
Safety warnings for devices containing flammable refrigerants
Only position the device in rooms where potentially leaking refrigerant cannot accumulate.
Only position the device in rooms where there is no source of ignition (e.g. open flames, an active gas appliance or an electric heater).
Please note that the refrigerant is odourless.
Only install the device in compliance with the national installation regulations.
Observe the national gas regulations.
EN 3
dehumidifier TTK 100 E
Page 4

Intended use

Only use the device for drying and dehumidifying room air, while adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry.
Intended use comprises:
dehumidifying and drying:
– living rooms, bedrooms, bathrooms and basements – laundries, holiday homes, camper vans, boats
maintaining the dryness of:
– storage spaces, archives, laboratories, garages – bathrooms, wash rooms, changing rooms etc.

Improper use

The device is not intended for industrial use.
Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, alterations or structural changes to the device are forbidden.
Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the operating manual, especially the Safety chapter.
Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.

Safety signs and labels on the device

Note
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
The following safety signs and labels are attached to the device:
TTK100E
Follow the manual
This symbol indicates that the operating manual must be observed.
Follow the repair manual
Disposal, maintenance and repair work of the refrigerant circuit may only be carried out in accordance with the manufacturer's specifications and by persons having a certificate of qualification. A corresponding repair manual is available from the manufacturer upon request.

Residual risks

Danger Natural refrigerant propane (R290)!
H220 – Extremely flammable gas. H280 – Contains gas under pressure; may explode if heated.
P210 – Keep away from heat, sparks, open flames and other ignition sources. No smoking. P377 – Leaking gas fire: Do not extinguish, unless leak can be stopped safely. P410+P403 – Protect from sunlight. Store in a well­ventilated place.
4 EN
dehumidifier TTK 100 E
Page 5
Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Do not touch the mains plug with wet or damp hands. Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Note
Do not operate the device without an air filter inserted into the air inlet! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

Behaviour in the event of an emergency

1. Switch off the device.
2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
3. Do not reconnect a defective device to the mains.

Information about the device

Description of the device

The device uses the principle of condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter, the evaporator and to the condenser located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime. The dehumidified, cooled air is slightly warmed at the condenser and blown out again. The drier air thus conditioned mixes with the air in the room. The humidity in the room where the device is positioned is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the condensed water either drops continuously or only during the defrost phase through the integrated drain nozzle into the condensation tank below. It is fitted with a float to measure the filling level.
The device has a control panel for operating and controlling the functions.
Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not installed correctly, the condensation tank indicator light (see chapter Operating elements) on the control panel is illuminated. The device switches off. The condensation tank indicator light only goes out again once the emptied condensation tank is reinserted.
Optionally, the condensed water can be drained by attaching a hose at the condensation connection.
The device can reduce the relative humidity of a room to approx. 30%.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the room temperature may rise slightly.
EN 5
dehumidifier TTK 100 E
Page 6

Device depiction

1
6
7
2
5
4
3

Transport and storage

Note
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

To make the device easier to transport, it is fitted with a carry handle.
To make the device easier to transport, it is fitted with wheels.
Before transporting the device, observe the following:
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
Do not use the power cable to drag the device.
Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
Set up the device in an upright position after transport.
Leave the device to rest for 12to24hours, so the refrigerant can accumulate within the compressor. Wait 12to24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.
No. Designation
1 Air outlet
2 Transport handle
3 Condensation drain hose connection
4 Wheels
5 Air inlet with air filter
6 Condensation tank
7 Control panel

Storage

Before storing the device, proceed as follows:
Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
Hold onto the mains plug while pulling the power cable out of the mains socket.
When the device is not being used, observe the following storage conditions:
Only store the device in a room measuring more than 4m2.
Dry and protected from frost and heat
In an upright position where it is protected from dust and direct sunlight
With a cover to protect it from invasive dust, if necessary
Place no further devices or objects on top of the device to prevent it from being damaged.
6 EN
dehumidifier TTK 100 E
Page 7

Assembly and installation

A
B
C
C
D

Scope of delivery

1x Device
1x Air filter
1x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.

Start-up

When positioning the device, observe the minimum distance from walls or other objects as described in the chapter Technical data.
When positioning the device, keep a sufficient distance to heat sources.
Make sure that no curtains or other objects interfere with the air flow.
When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations.
Inserting the air filter
Note
Do not operate the device without an air filter inserted into the air inlet! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
Make sure that the air filter is installed before switching the device on.
Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service.
Only position the device in rooms where potentially leaking refrigerant cannot accumulate.
Only position the device in rooms where there is no source of ignition (e.g. open flames, an active gas appliance or an electric heater).
Only put up the device in an upright, stable position on firm ground.
Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges.
Make sure that extension cables are completely unrolled.
EN 7
dehumidifier TTK 100 E
Inserting the condensation tank
Ensure that the float inside the condensation tank is inserted correctly.
Ensure that the condensation tank is empty and inserted correctly.
Connecting the power cable
Insert the mains plug into a properly secured mains socket.
Page 8

Operation

8
9
10 11 12 13 14
20
21
19
18
17
16
15
Avoid open doors and windows.
After being switched on, the device operates fully automatically.
The fan permanently runs in dehumidification mode even after the set nominal value has been reached until the device is switched off.
Operating elements
No. Designation Meaning
8 TANK FULL LED Condensation tank full or not
inserted correctly
9 Segment display Indicates the current relative room
humidity. Indicates the desired relative room humidity during setting Indicates the number of hours during timer programming.
10 Power button Switching the device on or off
11 Timer button Switches the timer function on or
off. For setting the number of hours for the timer (1h to 12h)
12 Arrow button down For setting the relative humidity
13 Arrow button up
14 Speed button For setting a high or low fan speed
level (30% to 80%RH in increments of 10%)
Display
No. Designation Meaning
15 Condensation tank full
indication
Is displayed when the condensation tank is full or not installed correctly
16 Indication of the target
humidity value
Indicates the desired humidity level (30% to 80%RH).
17 Fan speed indication One drop: low fan speed
Two drops: high fan speed (function for drying laundry)
18 Automatic defrost
indication
19 Indication of the timer
and the operating time
Is displayed during automatic defrost.
Indicates the set number of hours for the timer and the operating time.
20 Room temperature
indication
Indicates the current room temperature.
21 Room humidity indication Indicates the current relative
room humidity. Indicates the desired humidity level.
Switching the device on
Once you have completely installed the device as described in the Start-up chapter, you can switch it on.
1. Press the powerbutton(10).
ð The device starts to dehumidify.
8 EN
dehumidifier TTK 100 E
Page 9
Setting the operating mode
1/2''
Dehumidification
Laundry drying function
Dehumidification
The compressor keeps running until reaching the desired relative room humidity. If the desired humidity is exceeded, the compressor switches back on. The fan permanently runs even after the desired relative room humidity has been reached.
In this operating mode, the desired relative room humidity can be set at any time in increments of 10% within a setting range of 30% to 80%.
Setting the desired relative room humidity
Setting is possible in the range between 30% and 80% in increments of 10%.
1. Press the arrow buttons(12, 13) to adjust the relative room humidity.
ð The desired relative room humidity will be displayed by the
indication of the target humidity value(16).
Setting the fan speed
Using this function you can choose between a low and a high fan speed.
1. Press the fan speed button(14) to select either high or low fan speed.
ð With a low fan speed setting one drop will be displayed on
the fan speed indication(17), at a high fan speed (laundry drying function) there will be two.
Operation with hose attached to the condensation connection
For continuous operation or unattended dehumidification, please connect the supplied condensation drain hose to the device.
ü A suitable hose (diameter: 1/2inch) is ready for use. ü The device is switched off.
1. Use a suitable tool (e.g. a slotted screwdriver) to remove the cover from the connection.
2. Remove the condensation tank.
Setting the timer
For the device to switch off automatically after a predefined number of hours (1 to max. 12h) you can programme the timer.
The timer can be programmed in increments of 1hour.
Note
Do not leave the operating device unattended in a freely accessible room with an activated timer.
1. Press the Timer button(11) to activate the timer.
2. Repeatedly press the timer button(11) until the desired number of hours is displayed.
ð The indication of the timer and the operating time(19)
will be displayed to indicate the number of hours.
ð The device switches off after the predefined time.
3. Push one end of the hose onto the hose connection.
EN 9
dehumidifier TTK 100 E
Page 10
4. Check whether the hose is properly positioned on the connection. If necessary, adjust the position through the condensation tank opening.
5. Put the condensation tank back in.
6. Guide the other hose end to a suitable drain or sufficiently dimensioned collection container. Please note that the hose must not be kinked.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator during dehumidification. The device then carries out an automatic defrost by means of the hot gas feed. Here, a hot cooling agent is led into the iced evaporator for its surfaces to defrost.
The hot gas automatic defrost system integrated in the device automatically switches on the defrost cycle at regular intervals. The automatic defrost indication(18) will be displayed throughout the defrost process.
The duration of the defrost process can vary. Do not switch off the device during automatic defrost. Do not remove the mains plug from the mains socket.
Drying laundry
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe the minimum distances specified in the technical data.
The following humidity values are suitable for drying laundry:
cupboard dry= 46% relative humidity
iron dry= 58% relative humidity
slightly dried= 65% relative humidity
Adjust the settings for the relative humidity level to the device (e.g. 60% relative humidity for iron dry laundry). If necessary, use a measuring device to determine the humidity level.
1. Press the fan speed button(14) to set the high fan speed.
ð Two drops will be displayed on the fan speed
indication(17).
ð The function for drying laundry is activated.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
If necessary, remove the condensation drain hose and any residual fluid from it.
Empty the condensation tank, if need be.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
Remove the hose if you want to collect the condensate in the condensation tank again. Allow the hose to dry prior to storage. The hose can be connected in any operating mode for continuous operation.
10 EN
dehumidifier TTK 100 E
Page 11

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damage.
Check the on-site fusing.
Check the filling level of the condensation tank and empty it if necessary. The TANK FULL LED(8) must not light up.
Check the condensation tank for correct seating.
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Wait for 10minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec.
The device is running, but there is no formation of condensate:
Check the float in the condensation tank for dirt. If necessary, clean the condensation tank. The float must be able to move freely.
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Ensure that the relative room humidity complies with the technical data.
Check the preselected relative room humidity. The humidity in the room must be above the selected range.
Check the air filter for dirt. If necessary, clean or replace the air filter.
From the outside, check the condenser for dirt (see chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
The compressor does not start:
Check the room temperature. Observe the device's permissible operating range according to the technical data.
Ensure that the relative room humidity complies with the technical data.
Check the preselected relative room humidity. The humidity in the room must be above the selected range.
Check whether the overheating protection of the compressor has tripped. Disconnect the device from the mains and let it cool down for approx. 10minutes before reconnecting it.
The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or is losing performance:
Check the air inlets and air filters for dirt. Remove external dirt.
From the outside, check the device for dirt (see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company for cooling and air­conditioning or by Trotec.
Note
Wait for at least 3 minutes after maintenance and repair work. Only then switch the device back on.
Your device still does not operate correctly after these checks?
Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright position.
Condensate is leaking:
Check the device for leaks.
EN 11
dehumidifier TTK 100 E
Page 12

Error codes

The following error messages can be displayed on the segment display:
Error code Cause Remedy
E1 Temperature
sensor– circuit interrupted/ short circuit
E2 Defrost sensor–
circuit interrupted/ short circuit
E3 Humidity sensor–
circuit interrupted/ short circuit
Lo The current humidity
level is lower than 30%RH.
Hi The current humidity
level is higher than 90%RH.
E5 Chip communication
failure
Switch off the device and call the customer service.
Switch off the device and call the customer service.
Switch off the device and call the customer service.
Activate the dehumidifier at a humidity level which complies with the technical data. Should the alarm persist, please contact the customer service.
Activate the dehumidifier at a humidity level which complies with the technical data. Should the alarm persist, please contact the customer service.
Switch off the device and call the customer service.
12 EN
dehumidifier TTK 100 E
Page 13

Maintenance

Maintenance intervals

Maintenance and care interval before every
start-up
Check air inlets and outlets for
X X
dirt and foreign objects and clean ifnecessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and
X X
foreign objects and clean or replace if necessary
Replace the air filter
Check for damage
X
Check attachment screws
Test run
Empty the condensation tank and/ or drain hose

Maintenance and care log

Device type: .............................................
as needed at least every
2weeks
X X
X X
X X
X
at least every 4weeks
at least every 6months
X
Device number: ....................................
at least annually
X
Maintenance and care interval
Check air inlets and outlets for dirt and foreign objects and clean ifnecessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and foreign objects and clean or replace if necessary
Replace the air filter
Check for damage
Check attachment screws
Test run
Empty the condensation tank and/ or drain hose
Comments
1. Date: ...................................
Signature: ................................
5. Date: ...................................
Signature: ................................
9. Date: ...................................
Signature: ................................
13. Date: .................................
Signature: ................................
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
2. Date: ....................................
Signature: .................................
6. Date: ....................................
Signature: .................................
10. Date: ..................................
Signature: .................................
14. Date: ..................................
Signature: .................................
3. Date: ....................................
Signature: .................................
7. Date: ....................................
Signature: .................................
11. Date: ..................................
Signature: .................................
15. Date: ..................................
Signature: .................................
4. Date: ....................................
Signature: .................................
8. Date: ....................................
Signature: .................................
12. Date: ..................................
Signature: .................................
16. Date: ..................................
Signature: .................................
EN 13
dehumidifier TTK 100 E
Page 14

Activities required before starting maintenance

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec.

Refrigerant circuit

Danger Natural refrigerant propane (R290)!
H220 – Extremely flammable gas. H280 – Contains gas under pressure; may explode if heated.
P210 – Keep away from heat, sparks, open flames and other ignition sources. No smoking. P377 – Leaking gas fire: Do not extinguish, unless leak can be stopped safely. P410+P403 – Protect from sunlight. Store in a well­ventilated place.
The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air­conditioning or by Trotec.

Safety signs and labels on the device

Check the safety signs and labels attached to the device at regular intervals. Replace illegible safety signs!

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth.
4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air­conditioning or by Trotec.
5. Put the air filter back in.

Cleaning the air filter

Note
Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be deformed or rounded. Before reinserting the air filter, make sure that it is undamaged and dry!
The air filter has to be cleaned as soon as it is dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults).
1. Open and remove the flap at the air inlet.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
14 EN
dehumidifier TTK 100 E
Page 15
2. Remove the air filter.
3. Clean the filter using a slightly damp, soft, lint-free cloth. If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent.
6. Reinsert the flap into the device.

Emptying the condensation tank

If the condensation tank is full or not inserted correctly, the TANK FULL LED(8) will be illuminated and the condensation tank full indication(15) will be displayed. The compressor and fan will switch off.
1. Take the condensation tank out of the device.
4. Allow the filter to dry completely. Do not insert a wet filter into the device!
5. Put the air filter back in.
2. Empty the condensation tank over a drain or sink.
EN 15
dehumidifier TTK 100 E
Page 16
3. Rinse the condensation tank with clear water. Regularly clean the condensation tank using a mild cleaning agent (no detergent!).
4. Refit the condensation tank into the device. Make sure not to damage the float when inserting or removing the condensation tank. In doing so, make sure that the float is positioned correctly. In doing so, make sure that the condensation tank is inserted correctly, for otherwise the device cannot be switched back on.

Activities required after maintenance

If you want to continue using the device:
Leave the device to rest for 12to24hours, so the refrigerant can accumulate within the compressor. Wait 12to24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
Store the device according to the Storage chapter.

Technical annex

Technical data

Parameter Value
Model TTK100E
Max. dehumidification performance
Air flow rate 215m3/h
Operating range (temperature) 5°C to 32°C
Operating range (relative humidity)
Pressure suction side 1.2MPa
Pressure outlet side 2.4MPa
Max. permissible pressure 2.6MPa
Mains supply 220–240V/ 50Hz
Max. power input 0.57kW
Nominal current 2.4A
Refrigerant R290
Amount of refrigerant 122g
GWP factor 3
CO2 equivalent 0.000366t
Water tank 4.3l
Sound pressure level (atadistance of1m)
Dimensions (lengthx widthx height)
Minimum distance to walls and other objects
B: rear: C: side:
D: front:
Weight 15.5kg
30l / 24 h
30% to 80%RH
50dB(A)
274x 390x 612mm
A: top:
50cm 50cm 50cm 50cm
16 EN
dehumidifier TTK 100 E
Page 17
Wiring diagram
EN 17
dehumidifier TTK 100 E
Page 18
Overview and list of spare parts Note: The position numbers of the spare parts differ from those
describing the positions of other parts mentioned in this operating manual.
18 EN
dehumidifier TTK 100 E
Page 19
No. Spare Part No. Spare Part No. Spare Part
1 Base Pan 15 Y Tube 29 Fixture
2 Turning Wheel Ass'y 16 Capillary Tube 30 Fix Metal
3 Compressor Ass'y 17 Fix Tube 31 Side Plate
4 Rubber 18 Fan Motor 32 Side Plate
5 Suction Pipe 19 Fan Casing 33 Rear Panel
6 Discharge Pipe 20 Blower Wheel 34 Handle
7 Plate 21 Screen 35 Front Panel
8 Capacitor (For Compressor) 22 Capacitor (For Fan Motor) 36 Control Plate
9 Fix Metal 23 Power Supply Cord Complete 37 Control Panel
10 Sensor (For Humidity) 24 Fixture 38 Intake Grill
11 Proximity Switch 25 Cover 39 Tank Lid
12 Drainage Pan 26 Control Board 40 Fix Tube
13 Evaproator Ass'y 27 PC Board 41 Drain Bucket
14 Condenser Ass'y 28 Sensor (For Evap)

Disposal

The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website https://de.trotec.com/shop/.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
Have the refrigerant (propane) disposed of appropriately and according to the national regulations by a company with the relevant certification (European Waste Catalogue 160504).
EN 19
dehumidifier TTK 100 E
Page 20
Trotec GmbH
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400 +49 2452 962-200
info@trotec.com www.trotec.com