Trotec TEH 300, TEH 200, TEH 400 Original Instructions Manual

Page 1
TEH 200 / TEH 300 / TEH 400
EN
ORIGINAL INSTRUCTIONS
ELECTRIC HEATER
TRT-BA-TEH200-TEH300-TEH400-TC2014-33-003-EN
Page 2

Table of contents

You can download the current version of the instructions and the EUdeclaration of conformity via the following link:

Notes regarding the instructions

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
TEH 200
https://hub.trotec.com/?id=42896
TEH 300
https://hub.trotec.com/?id=42897
TEH 400
https://hub.trotec.com/?id=42898
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the instructions must be observed.

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
Do not use the device in potentially explosive rooms and do not install it there.
Do not use the device in atmospheres containing oil, sulphur, chlorine or salt.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Only put up the device in an upright, stable position on firm ground.
Make sure that the air inlet and outlet are not obstructed.
Make sure that the suction side is kept free of dirt and loose objects.
Do not place the device on combustible ground.
2 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 3
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
Let the device dry out after a wet clean. Do not operate it when wet.
Do not expose the device to directly squirting water.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
Disconnect the device from the mains, if it is not in use.
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
Do not sit on the device.
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
Do not use the device in immediate proximity to curtains.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Only use original spare parts, for otherwise safe and functional operation cannot be ensured.

Intended use

Only use the device TEH 200/ TEH 300/ TEH 400 for heating atmospheric air (intake temperature: -20°C to max. +40 °C) whilst adhering to the technical data.

Improper use

The device TEH 200/ TEH 300/ TEH 400 is not suited for installation in fluids or on flooded or boggy grounds. The device must not be used for sucking in fluids, e.g. from filled tanks or basins.
The devices must not be operated when stacked on top of one another for storage.
Any unauthorised changes, modifications or alterations to the device are forbidden.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric heaters.
have read and understood the instructions, especially the Safety chapter.
Electrically skilled person
Electrically skilled personnel must be able to read and understand electric circuit diagrams, to put electrical systems into service and to maintain them, to wire control cabinets, to ensure the functionality of electrical components and to identify possible hazards from electrical and electronic systems.
Instructed person
Instructed persons have been informed of the tasks they were entrusted with as well as of potential hazards resulting from inappropriate behaviour. They are allowed to operate and transport the device and perform simple maintenance activities (cleaning the housing, cleaning the fan).
The device is to be maintained and looked after by instructed personnel.

Residual risks

Warning of hot surface
Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present!
Warning
Improper handling entails a risk of burning and electric shock. Only use the device as intended!
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Warning
The air outlet grille becomes very hot during operation and cause burns if touched! To not touch it. Keep a distance.
Warning
To avoid damages to the device, never operate the device without an inserted air filter!
Warning
Improper installation entails a risk of fire. Do not place the device on combustible ground. Do not place the device on high-pile carpets.
EN 3
electric heater TEH 200 / TEH 300 / TEH 400
Page 4
Warning
In order to avoid overheating and fire hazards, the heater must not be covered.

Behaviour in the event of an emergency

1. Immediately switch the device off via the main emergency stop switch or the emergency stop at the upstream distributor.
2. Remove persons from the danger area.
3. Disconnect the device from the electric circuit.
4. Do not reconnect a defective device to the mains.

Information about the device

Device description

The electric heater was designed as a robust, mobile unit also to be positioned outdoors.
The device comes equipped with two lockable swivel castors(5) and two trestle rollers(7) each. Forklift pockets and crane lugs are attached to the housing as transport aids, enabling convenient transport and space-saving storage by stacking up to 3 devices on top of each other.
The housing is designed as welded frame construction and provided with partially removable steel sheet panels. The electrical control box made of steel is mounted in horizontal position, protected between the stacking handle bars on the housing, and contains all switching devices, operating elements, indicator lights, safety devices and the control unit. All steel and sheet metal parts are galvanized and powder­coated.
The device is designed ready-to-install and comes with all the electrical and mechanical components as well as safety installations required for safe and functional operation.
To ensure safe transport and operation, the device is also equipped with a shock protection frame.
Functioning principle
The air is taken in by the fan via the integrated bag filter(10) and heated by means of the multi-stage electric heating. Four different temperature levels can be selected between 0 and 100%. These are kept constant by the integrated controller with the maximum outlet temperature being reduced to approx. 60°C(±5°C).
Thanks to the two-stage fan operation a higher temperature increase can be achieved by selecting the lower stage (approx. 2/3 of the nominal air volume). The integrated, electronically controlled control unit with air volume flow measurement and automatic rotational speed control of the fan ensures nearly constant volumetric flow rates covering a wide load range (e.g. for variable hose lengths).
The temperature increase refers to the sucked in air temperature (usually the ambient temperature) and is increased according to the preselection. The temperature sensors at air inlet and outlet transmit the current temperature values to the control unit, which then, depending on the demand, keeps the preselected temperature increase constant by means of the control and operation of individual heating elements or the entire heater.
4 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 5

Device depiction

1
2 3
4
5
6
7
8
9
8
10
11
12
2
5
6
7

Transport and storage

Note
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

Remove all packing materials which serve to protect the device during transport.
Should the electric heater be damaged, please contact the responsible dealer or manufacturer, where the purchase was made.
The electric heater may only be lifted at the points provided with lifting gear (forklift pockets(6), transport lugs(2)) intended for handling. The carrying capacity of the lifting gear must be suitable for the weight of the electric heater (see technical data).
No. Designation
1 Control panel with electrical control box 2 Transport lug
To make the device easier to transport, it is fitted with wheels.
3 Shock protection frame 4 Air outlet with hose connection 5 Swivel castor (lockable)
Only wheel the device on firm, level ground. The following should be observed before transporting the
device using the castors:
6 Forklift pockets 7 Trestle rollers/ fixed castors 8 Lateral cover panel 9 Main switch with emergency stop function 10 Air inlet with weather protection grid and air filter access 11 Mains connection: CEE plug, 5-pin 12 Cover flap electrical control box
The following should be observed before transporting the device using lifting gear:
Warning
Trip hazard! Make sure that nobody is situated in the immediate proximity.
Warning
Risk of injury from suspended loads. Make sure that nobody is situated in the immediate proximity.
Only instructed persons are allowed to perform the transport by use of lifting gear.
Consider the centre of gravity when transporting the load.
The following should be observed after transporting the device:
EN 5
electric heater TEH 200 / TEH 300 / TEH 400
Lock the swivel castors(5)!
Page 6

Storage

5mm
When the device is not being used, observe the following storage conditions:
dry and protected from frost and heat
in an upright position where it is protected from dust and direct sunlight
with a cover to protect it from invasive dust, if necessary
Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service.
Have the device checked once a year by an electrically skilled person at any rate.
The device can be stacked for storage purposes. In doing so, observe the following:
Only use suitable lifting gear.
Make sure that the rollers of the device at the bottom are locked and the device cannot move. To protect the rollers and the frame, the bottommost device is to be jacked up as illustrated below.
Warning
To prevent damage to the device, the bottom strut should not be allowed to rest on the support. A minimum distance of 5mm to the bottom must be observed!
Make sure that the wheels of the device to be stacked are pointing inwards as is indicated in the following figure.
The maximum amount of devices to be stacked on top of one another is 3 (for transportation in a truck: max. 2 devices).
Place the device at the bottom on firm, level ground.
6 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 7

Assembly and installation

9 13 14 15 16 17 18 19

Operation

Scope of delivery

1x Device
1x Manual

Start-up

Warning
Operating several devices stacked onto one another is prohibited for safety reasons. Do not take the devices into operation when stacked.
When positioning the device, observe the minimum distance from walls or other objects as described in the Technical data chapter.
Position the device on firm, dry and level ground. Depending on the floor load capacity a panel for weight distribution is to be provided.
When setting up the device, ensure a sufficient distance for air inlet and outlet as well as for operation (see Technical data).
Lock the swivel castors and secure the device against rolling away.
Make sure that extension cables are completely unrolled.
When positioning the device outdoors, make sure that no water can enter the device through the air outlet. Connect an air hose to the air outlet to minimize the risk.
Inserting the air filter
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
Make sure that the air filter is installed before switching the device on.
Control panel
No. Designation
9 Main switch with emergency stop function
Position 0: Device is switched off.
Position I: The device is switched on. 13 Selection step switch 14 Button EIN-ON 15 Button AUS-OFF 16 Lamp BETRIEB-OPERATION 17 Lamp BEREIT-STAND BY 18 Lamp NACHLAUF-RUN ON 19 Lamp STÖRUNG-FAULT
Note
The main switch serves for switch-on and may only be used as emergency stop switch for disconnection from the mains in case of an emergency. For normal switch-off please use the AUS-OFF button(15), which initiates the rundown function (NACHLAUF-RUNON lamp(18) illuminated). Only disconnect the device for transport or storage via the main switch at the end of
the rundown period.
Connecting the power cable
Insert the mains plug into a properly secured mains socket.
EN 7
electric heater TEH 200 / TEH 300 / TEH 400
Page 8
Switch-on of the device
ü The side covers, the electrical control box and the weather
protection grid are closed.
ü The bag filter is built in correctly. ü Air inlet and air outlet are free from objects and/or
obstructions.
ü The device is secured against rolling away.
1. Insert the mains plug into a properly secured mains power socket. Observe the rotating field (clockwise rotation).
2. Rotate the mains switch(9) to position "I".
ð The control unit is activated. ð The device is ready for operation. ð The BEREIT-STAND BY lamp(17) lights up.
3. Select the desired temperature level via the selection step switch(13).
4. Actuate the green EIN-ON button(14). ð The green BETRIEB-OPERATION lamp(16) will be
illuminated while the BEREIT-STAND BY lamp(17) goes out.
ð The electric heater starts up in the selected temperature
level.
Note
The air outlet temperature is electronically limited to approx. 60°C(±5°C) regardless of the preselection. In case of the standard models the levels 0 to 7 are engaged. In case of devices without air volume switching only the levels 0 to 3 are engaged. The levels 8 and upwards are reserved for special designs.
Note
Selecting the temperature level does not limit the electric current consumption from the mains!
No. Designation
0 100 % air flow rate and no temperature increase 1 100 % air flow rate and low temperature increase
(∆T = approx. 15°C)
2 100 % air flow rate and moderate temperature increase
(∆T = approx. 25°C)
3 100 % air flow rate and maximum temperature increase
(∆T = approx. 40°C) 4 66 % air flow rate and no temperature increase 5 66 % air flow rate and low temperature increase
(∆T = approx. 20°C) 6 66 % air flow rate and moderate temperature increase
(∆T = approx. 40°C) 7 66 % air flow rate and maximum temperature increase
(∆T = approx. 60°C)
Switch-off
1. Press the red AUS-OFF button(15).
ð The heating switches off. ð The fan operates in rundown mode, e.g. the fan runs on
until the heating elements have cooled down to below 40°C.
ð The BETRIEB-OPERATION lamp(16) goes out. ð The NACHLAUF-RUN ON lamp(18) is illuminated. ð The BEREIT-STAND BY lamp(17) is illuminated. ð Restart can be carried out at any time.
2. Wait until rundown operation is completed.
ð The NACHLAUF-RUN ON lamp(18) goes out. ð The device is again ready for operation or else ready for
switch-off via the main emergency stop switch(9).
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Proceed as described in the Switch-off section.
Set the main emergency stop switch(9) to position "0".
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
8 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 9
Electrical control box
28
24
27
26
25
12
20
The following components are located in the control box:
Overtemperature protection
For overheating protection the electric heater comes equipped with several safety elements:
Disconnection of the electric heating from the mains when falling below the minimum air volume.
Reduction of the maximum air outlet temperature at approx. 65°C.
Rundown operation of the fan after switch-off to dissipate the accumulated heat at the electric heating until the air outlet temperature has dropped to below 40°C.
Switch-off of the device by means of a safety temperature limiter.
- The safety temperature limiter(24) can only be reset by actuating the integrated reset switch(20). This switch is located on the left side of the electrical control box.
No. Designation
24 Safety temperature limiter with reset switch 25 Control 26 Analogous operating hours counter 27 Fuses 28 Pressure sensor
Opening the electrical control box
The electrical control box may only be opened by instructed persons. Only a qualified electrician is allowed to perform repair work on the electrical system.
1. Open the cover flap at the electrical control box(12).
EN 9
electric heater TEH 200 / TEH 300 / TEH 400
Page 10
Control
26
21
22
23
The control unit is located inside the electrical control box. The control unit displays further information regarding the operating condition of the device. Next to it is the analogous operating hours counter(26).
The control unit ensures the constant regulation of the volumetric flow, even when connecting different hose lengths etc.
The control unit can also be used to display the current parameters for volume flow, pressure and temperature. Additionally, further faults are also indicated here.
For reading the control unit or operating hours counter first the electrical control box must be opened. The current parameters and faults are indicated on the display(21).
From the start screen the buttons A(23) and B(22) can be used to browse through the menu.
Input temperature in°C (temp.-in),
Output temperature in°C (temp.-out),
Output temperature in °C (delta-T):
Digital operating hours display in h (run hours)
The following parameters can be called up:
Volumetric flow in m3/h (airflow):

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
The STÖRUNG-FAULT lamp(19) lights up directly after switch-on of the device:
Aborted rundown from previous operation, which has led to tripping of the safety temperature limiter. Actuate the reset switch(20) of the safety temperature limiter and restart the device.
Malfunction in the software of the control unit or the frequency converter (optional), which prevents the device from starting. Acknowledge the fault by means of the AUS-OFF button(15). If the STÖRUNG-FAULT lamp(19) continues to be lit, switch the device off via the main switch(9) and back on again after approx. 10 seconds.
10 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 11
The STÖRUNG-FAULT lamp(19) lights up during operation:
Insufficient air flow rate:
Check whether the filter is clogged. Replace the filter if necessary.
Check whether the air resistance in the ensuing air line is too high (length, bends, foreign objects etc.). Reduce the air resistance if necessary.
No sign of heating:
The heating may be defective. Have the heating repaired by a qualified electrician.
The air flow rate may be too low. See fault Insufficient air flow rate.
Thermostat tripped:
The air flow rate may be too low. See fault Insufficient air flow rate.
The thermostat may be defective. Have the thermostat replaced by a qualified electrician.
An error in the sensor circuit may have occurred. Have the sensor circuit checked by a qualified electrician.
There was a temporary mains voltage drop or power failure and a consequent failure of the rundown function. Actuate the reset switch(20) of the thermostat and restart immediately. If no warmth is required, set the selection step switch to position0.
Electric installation:
One or several electrical components may have failed. Have the electric installation checked and, if required, defective parts replaced by a qualified electrician.
Pressure sensor tripped:
The minimum air volume was not reached. See fault Insufficient air flow rate.
Faults control unit
For reading the fault messages at the control unit first the electrical control box must be opened.
The STÖRUNG-FAULT lamp(19) also serves as collective fault message for the control. The following faults will be displayed in detail on the screen of the control unit:
Motor or fan fault.
Fault in the air volume flow:
- Pressure sensor has tripped.
Critical overtemperature:
- Safety temperature limiter has tripped.
Note
In case of all faults the heating is switched off, but not disconnected from the mains. After elimination of the fault, acknowledge it using the AUS-OFF button(15) (reset).
Your device still does not operate correctly after these checks?
Please contact the customer service. If necessary, bring the device to an authorized specialist electrical company or to Trotec for repair.
EN 11
electric heater TEH 200 / TEH 300 / TEH 400
Page 12

Maintenance

Trotec electric heaters are designed for long hours of operation with minimum maintenance effort. Safe operation of the device requires all built-in components, especially the safety temperature limiter(STB), to be checked and cleaned after 6 months at the latest or after every 4,000 operating hours as well as all damaged components to be replaced.
To clean the inside of the housing, the fan and further electrical components need to be protected from water ingress with the appropriate means!

Activities required before starting maintenance

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device at the main switch.
Wait for the end of the rundown period if the device was in operation beforehand.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning of electrical voltage Maintenance tasks and repair work may only be
performed by qualified electricians or Trotec.

Changing the filter

The filter change intervals depend on the degree of air pollution and the filter quality. Dirty filters impair the performance ability of the electric heater. Therefore, in case of heavily contaminated intake air, they are to be inspected at least once a week, otherwise at least monthly and replaced whenever necessary.
1. Open the weather protection grid by means of the two handles.
2. Remove the bag filter.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
3. Install the new bag filter.
4. Then close the weather protection grid again.
12 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 13

Maintenance intervals

Maintenance and care interval before every
start-up
Check air inlets and outlets for dirt
X
and foreign objects and clean if necessary
Cleaning the exterior Visual inspection of the inside of
the device for dirt Checking of air inlet grid and air
X X
filter for dirt and foreign objects and cleaning or replacement if necessary
Air filter replacement Checking for damage
X
Checking the safety temperature limiter
Check the attachment screws Test run
as needed at least every
2 weeks
X X
X X
X X
at least every 4 weeks
at least every 6 months
X
X
at least annually
X
EN 13
electric heater TEH 200 / TEH 300 / TEH 400
Page 14

Maintenance and care log

Device type: .............................................
Device number: ....................................
Maintenance and care interval
Checking of air inlets and outlets for dirt and foreign objects and cleaning if necessary
Cleaning the exterior Visual inspection of the inside of
the device for dirt Checking of air inlet grid and air
filter for dirt and foreign objects and cleaning or replacement if necessary
Air filter replacement Checking for damage Checking of attachment screws Test run Remarks:
1. Date: ...................................
Signature: ................................
5. Date: ...................................
Signature: ................................
9. Date: ...................................
Signature: ................................
13. Date: .................................
Signature: ................................
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
2. Date: ....................................
Signature: .................................
6. Date: ....................................
Signature: .................................
10. Date: ..................................
Signature: .................................
14. Date: ..................................
Signature: .................................
3. Date: ....................................
Signature: .................................
7. Date: ....................................
Signature: .................................
11. Date: ..................................
Signature: .................................
15. Date: ..................................
Signature: .................................
4. Date: ....................................
Signature: .................................
8. Date: ....................................
Signature: .................................
12. Date: ..................................
Signature: .................................
16. Date: ..................................
Signature: .................................

Technical annex

Technical data

Parameter Value
Model (version 3.0) TEH 200 TEH 300 TEH 400 Article number 1.410.000.150 1.410.000.155 1.410.000.160 Max. amount of air 3,000 m3/h 6,000 m3/h 9,000 m3/h Heating capacity 40kW (34,394 kcal) 80kW (68,788 kcal) 120kW (103,181 kcal) Air pressure (max. compression) 600Pa 600Pa 600Pa Max. air outlet temperature * 65°C 65°C 65°C Max. temperature increase (ΔT) 60°C 60°C 60°C Permissible intake temperature -20°C to max. +40°C -20°C to max. +40°C -20°C to max. +40°C Control 8-step selection switch for air flow rate and temperature Step 0 Air flow rate 3,000 m3/h 6,000 m3/h 9,000 m3/h
Temperature increase (ΔT) - - -
14 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 15
Parameter Value
Step 1 Air flow rate 3,000 m3/h 6,000 m3/h 9,000 m3/h
Temperature increase (ΔT) 15°C 15°C 15°C
Step 2 Air flow rate 3,000 m3/h 6,000 m3/h 9,000 m3/h
Temperature increase (ΔT) 25°C 25°C 25°C
Step 3 Air flow rate 3,000 m3/h 6,000 m3/h 9,000 m3/h
Temperature increase (ΔT) 40°C 40°C 40°C
Step 4 Air flow rate 2,000 m3/h 4,000 m3/h 6,000 m3/h
Temperature increase (ΔT) - - -
Step 5 Air flow rate 2,000 m3/h 4,000 m3/h 6,000 m3/h
Temperature increase (ΔT) 20°C 20°C 20°C
Step 6 Air flow rate 2,000 m3/h 4,000 m3/h 6,000 m3/h
Temperature increase (ΔT) 40°C 40°C 40°C
Step 7 Air flow rate 2,000 m3/h 4,000 m3/h 6,000 m3/h
Temperature increase (ΔT) 60°C 60°C 60°C Input voltage 3~/PE-400V / 50-60Hz 3~/PE-400V / 50-60Hz 3~/PE-400V / 50-60Hz Max. current consumption 61A (41.5kW) 123A (84kW) 182A (125.5kW) Fusing / mains connection 63A / CEE63A, 5-pin 125A / CEE 125A, 5-pin 200A termination Sound pressure level (3m distance) 75dB(A) 76dB(A) 78dB(A) Hose connector Ø450mm Ø450mm Ø600mm Suitable for hose lengths to 100m 100m 100m Mobility wheeled / forklift / crane wheeled / forklift / crane wheeled / forklift / crane Dimensions (length x width x height) 1,625x 800x 1,270(mm) 1,625x 800x 1,270(mm) 1,920x 950x 1,450(mm) Weight 280kg 310kg 460kg Cable cross-section, min. 16mm
2
50mm
2
95mm
2
Overheating protection yes yes yes Minimum distance to all sides during
1 m 1 m 1 m
operation and maintenance
* The maximum air outlet temperature of the standard version is automatically electronically limited to 65°C. Other versions with higher air outlet temperatures are optionally available on request.
** All of the technical data +/- 10%.
EN 15
electric heater TEH 200 / TEH 300 / TEH 400
Page 16

Circuit diagram TEH 200/300/400

16 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 17
EN 17
electric heater TEH 200 / TEH 300 / TEH 400
Page 18
18 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 19
EN 19
electric heater TEH 200 / TEH 300 / TEH 400
Page 20
20 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 21
EN 21
electric heater TEH 200 / TEH 300 / TEH 400
Page 22
22 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 23
EN 23
electric heater TEH 200 / TEH 300 / TEH 400
Page 24
24 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 25
EN 25
electric heater TEH 200 / TEH 300 / TEH 400
Page 26
26 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 27

Dimensional drawing TEH 200/300

230
755
700 795
280
450
670
385
397,50
DN450
280
1315 1400 1620
1096
750 140 140
D
E
F
C
1
2
3
4
B
A
3
2
1
5
C
D
4
6
7
8
A
B
TEH
Index:
Änderung:
Copying of this Document, and giving it to others and the use or communication of the
contents there of, are forbidden without express authority. Offenders are liable to the
payment of damages
Weitergabe sowie Vervielfältigung dieser Unterlage,Verwertung und Mittteilung ihres
Inhalts ist nicht gestattet, soweit nicht ausdrücklich zugestanden Zuwiderhandlungen
verpflichten zu Schadenersatz
Projekt:
Norm:
DIN
Pos. Nr.:
Grebbener Straße 7, D-52525 Heinsberg
DIN ISO 2768-1m
Stückzahl:
2
Allgem. Toleranz:
1:10
TEH 200/300 3.0
Z-HH-200u.300-Komplett
24.09.2018
Volksdorf
GEWICHT:
A3
BLATT:
MASSSTAB:
ZEICHNUNGSNR.
BENENNUNG:
WERKSTOFF:
DATUM
NAME
OBERFLÄCHE:
Datum:
GENEHMIGT
GEPRÜFT
GEZEICHNET
EN 27
electric heater TEH 200 / TEH 300 / TEH 400
Page 28

Dimensional drawing TEH 400

210
990
850 950
240
570
820
495
475
DN600
240
1450 1520 1920
1096
750 140 140
130
D
E
F
C
1
2
3
4
B
A
3
2
1
5
C
D
4
6
7
8
A
B
TEH
Index:
Änderung:
Copying of this Document, and giving it to others and the use or communication of the
contents there of, are forbidden without express authority. Offenders are liable to the
payment of damages
Weitergabe sowie Vervielfältigung dieser Unterlage,Verwertung und Mittteilung ihres
Inhalts ist nicht gestattet, soweit nicht ausdrücklich zugestanden Zuwiderhandlungen
verpflichten zu Schadenersatz
Projekt:
Norm:
DIN
Pos. Nr.:
Grebbener Straße 7, D-52525 Heinsberg
DIN ISO 2768-1m
Stückzahl:
3
Allgem. Toleranz:
1:10
TEH 400
Z-HH-200u.300-Komplett
24.09.2018
Volksdorf
GEWICHT:
A3
BLATT:
MASSSTAB:
ZEICHNUNGSNR.
BENENNUNG:
WERKSTOFF:
DATUM
NAME
OBERFLÄCHE:
Datum:
GENEHMIGT
GEPRÜFT
GEZEICHNET
28 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 29

Exploded assembly drawing

4
3 5
1
11
15 16
8
6
9
7
14
17
13
12
10 2
37 3635
34
33
32
38 38
Info
The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions.
EN 29
electric heater TEH 200 / TEH 300 / TEH 400
Page 30

List of spare parts

Spare parts TEH 200 TEH 300 TEH 400
Item Designation Quantity Trotec no. Trotec no. Trotec no.
1
Main switch
2
Heating elements 6 x P 1000 1905 12 x P 1000 1905 18 x P 1000 1905
3
LED element white 24 V
4
LED element green 24 V
5
LED element red 24 V
6
Indicator light yellow
7
Indicator light green
8
Indicator light red
9
Indicator light white
10
Air filter
11
Cam switch
12
Trestle roller
13
Lockable swivel castor
14
Push button green
15
Push button red
16
Control cabinet filter TEH
17
Radial fan
18
Relay
19
Operating hours counter Lateral insulation
20
Base insulation
21
Pressure sensor
22
Semi-conductor relay 4 x P 1000 1431 8 x P 1000 1431 12 x P 1000 1431
23
Load relay 24 V 4 x P 1000 1238 8 x P 1000 1238 12 x P 1000 1238
24
Power adapter
25
Safety temperature limiter
26
Fuse C 10 A
27
Fuse C 16 A
28
Fuse B 32 A 2 x P 1000 4056 4 x P 1000 4056 6 x P 1000 4056
29
Temperature probe
30
Temperature probe
31
Isolating terminal
32
Protective frame (incl. mounting brackets)
33
Air filter inspection door
34
Fan cover
35
Control cabinet cover
36
E-heater cover
37
Spigot
38
Cover
1
P 1000 1454 P 1000 1454 P 1000 1532
2
P 1000 1447 P 1000 1447 P 1000 1447
1
P 1000 1445 P 1000 1445 P 1000 1445
1
P 1000 1446 P 1000 1446 P 1000 1446
1
P 1000 1450 P 1000 1450 P 1000 1450
1
P 1000 0244 P 1000 0244 P 1000 0244
1
P 1000 1448 P 1000 1448 P 1000 1448
1
P 1000 1449 P 1000 1449 P 1000 1449
1
P 1000 1563 P 1000 1563
1
P 1000 1455 P 1000 1455 P 1000 1455
2
P 1000 1394 P 1000 1394 P 1000 1394
2
P 1000 1393 P 1000 1393 P 1000 1393
1
P 1000 1443 P 1000 1443 P 1000 1443
1
P 1000 1444 P 1000 1444 P 1000 1444
1
P 1000 1392 P 1000 1392 P 1000 1392
1
P 1000 1383 P 1000 1994 P 1000 1384
2
P 1000 6608 P 1000 6608 P 1000 6608
1
P 1000 1477 P 1000 1477 P 1000 1477 2 x P 1000 1989
2 x P 1000 1509
1
P 1000 1388 P 1000 1388 P 1000 1388
1
P 1000 1313 P 1000 1313 P 1000 1313
1
P 1000 1432 P 1000 1432 P 1000 1432
1
P 1000 4058 P 1000 4058 P 1000 4058
1
P 1000 4057 P 1000 4057 P 1000 4057
1
P 1000 1430 P 1000 1430 P 1000 1430
1
P 1000 1429 P 1000 1429 P 1000 1429
1
P 1000 1561 P 1000 1561 P 1000 1561
1
P 1000 6972 P 1000 6972 P 1000 6973
1
P 1000 6974 P 1000 6974 P 1000 6975
2
P 1000 6976 P 1000 6976 P 1000 6977
1
P 1000 6978 P 1000 6978 P 1000 6979
1
P 1000 6980 P 1000 6980 P 1000 6981
1
P 1000 1386 P 1000 1386 P 1000 1387
2
P 1000 1982 P 1000 1982 P 1000 1983
2 x P 1000 1989 2 x P 1000 1509
1 x P 1000 1563 1 x P 1000 1564
2 x P 1000 1512 2 x P 1000 1511
30 EN
electric heater TEH 200 / TEH 300 / TEH 400
Page 31

Disposal

The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
EN 31
electric heater TEH 200 / TEH 300 / TEH 400
Page 32
Trotec GmbH & Co. KG
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400 +49 2452 962-200
info@trotec.com www.trotec.com
Loading...