Information about the device
1
2
43
6
5
5
6
7
8
10
12
9
11
Description of the device
Air cleaners are used to filter the room air. On building sites and
renovation areas high concentrations of dust can arise, for
instance when using angle grinders or during blasting, chiselling
or demolition operations as well as when mixing dry mortar or tile
cement.
The air is conveyed through the air intake opening (10) via the
filters. The air filtered this way can stream back outside via the air
outlets (4) at the sides and on top.
Filter types (not included in the scope of delivery)
The following air filters are geared to the device and come with
the largest possible filter surface based on the geometric
dimensions. Consequently, a high air flow rate is achieved.
Device depiction
No.Designation
1G4 Z line filter
2Pleated filter F7
3G3 spray paint filter
4H13 high-efficiency particulate air filter (HEPA)
Note:
Please observe that only one prefilter (1, 2 or 3) can be implemented in a device at a time. Operation without prefilter is not
advisable, for otherwise the fan could be damaged and the lifetime of the high-efficiency particulate air filter (4) is reduced.
ModelTAC 750 E
Max. air volume without filter750 m³/h
Max. air volume with G4 filter680 m³/h
Max. air volume with G4 + H13 filter290 m³/h
Power input0.120 kW
Input voltage230 V / 50/60 Hz
Sound level (1 m)78 dB(A)
Dimensions (length x width x height)430 mm x 315 mm x 430 mm
Max. weight empty/filled6.0/7.5 kg
Air transport hose Tronect SP-T2036100001200
Hose/pipe adapter (Ø123)6100010010
Air transport hose Tronect TF-L1276100001120
Extension cable7333000376
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.
• Observe the storage and operating conditions (see chapter
Technical data).
Intended use
Only use the device to clean atmospheric air from non-conducting
and non-combustible dusts or suspended matter whilst adhering
to the technical data.
Improper use
Do not use the device in potentially explosive areas.
Do not place the device on damp or flooded ground.
Do not use the device to siphon off vapours or fluids.
Any unauthorised changes, modifications or alterations to the
device are forbidden.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the operating manual, especially
the Safety chapter.
Residual risks
Safety
Carefully read the operating manual before using the device
and keep it within reach!
• Do not use the device in potentially explosive rooms.
• Do not use the device in atmospheres containing oil, sulphur,
chlorine or salt.
• Only put up the device in a stable position on firm ground.
• Provide appropriate weather protection.
• Keep air inlets and outlets clear.
• Never insert objects into the device.
• Do not cover or transport the device during operation.
• Never use the device as storage place or footstep.
• Ensure that all electric cables outside of the device are
protected from damage (e.g. from animals).
• Only use extensions to the connecting cable which are
appropriate to the device power consumption, the length of
its cable and its use. Avoid electrical overload.
• Dispose of replaced filters properly.
Hazardous electric voltage!
Work on the electrical components must only be
carried out by electrically skilled persons!
Hazardous electric voltage!
Before any work on the device, remove the mains plug
from the mains socket!
Danger!
Do not leave the packaging lying around. Children may
use it as a dangerous toy!
Danger!
This appliance is not a toy! Children must be kept away
from the device.
Danger!
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way.
Observe the personnel qualifications.
3Operating Manual – Air Cleaner TAC 750 EEN
Page 5
Transport and storage
8
10
Start-up
Transport
For easier transportation the device is equipped with a transport
handle.
Before transporting the device, proceed as follows:
1. Switch off the device.
2. Disconnect the mains plug from the socket and coil up the
cable. Do not use the power cable to drag the device!
1. Completely unwind the power cable and connect it to a fused
socket.
2. Press the On/Off switch (8).
– The switch lights up in green.
– The fan starts running after a delay.
Storage
When the device is not being used, observe the following storage
conditions:
•Dry,
• Protected from dust and direct sunlight,
• With a plastic cover to protect it from invasive dust, if
necessary.
Operation
Caution!
In order to protect the device from damage, we
recommend using it with at least one filter.
• Position the device near the source of air contamination or
install the air hose at this source.
• Set the device in an upright and stable position.
• Do not create tripping hazards when laying the power cable
or other electric cables.
• Make sure that no curtains or other objects interfere with the
air flow.
• Make sure that extension cords are completely unrolled.
3. Adjust the speed controller (10) to the desired intensity level.
Shutdown
1. Press the On/Off switch (8).
2. Remove the mains plug from the mains socket.
3. Clean the device according to chapter Maintenance.
4. Store the device according to chapter Storage.
ENOperating Manual – Air Cleaner TAC 750 E4
Page 6
Errors and faults
5
6
5
1, 2
12
12
13
The accurate functionality of the device was tested during
production a number of times. However, if functionality faults do
occur, then check the device according to the following list.
The device does not start:
• Check the power connection (230 V AC /50 Hz).
• Check the mains plug for damages.
• Check the position of the speed controller.
Your device still does not operate correctly after these
checks?
®
Please contact the TROTEC
Repair work which requires the housing to be opened
must only be carried out by electrically skilled
persons or by TROTEC
customer service.
®
.
3. Remove the air filter.
Maintenance
Activities required before starting maintenance
• Do not touch the mains plug with wet or damp hands.
Before opening the device, switch the device off and
disconnect it from the mains.
Changing the filter
1. Unlock both tension locks (5) at the left and right side of the
device.
2. Remove the front cover (6) from the device.
Note
If you only want to change this air filter, please continue
with step 10.
If you want to exchange the HEPA filter as well, please
continue with step 4.
4. Remove the four knurled screws (12).
5. Remove the cover (13) from the device.
5Operating Manual – Air Cleaner TAC 750 EEN
Page 7
6. Remove the air filter (3).
3
3
13
12
12
1, 2
5
6
5
7. Install the new air filter (3).
10. Install the new air filter. In doing so, pay attention to the
correct alignment (front/rear).
11. Put the front cover (6) back on the device.
12. Fasten the two lateral tension locks (5).
8. Put the cover (13) back on the device.
9. Affix the four knurled screws (12).
ENOperating Manual – Air Cleaner TAC 750 E6
Page 8
Cleaning the housing
Clean the device with a soft, damp and lint-free cloth. Ensure that
no moisture enters the housing. Do not use any sprays, solvents,
alcohol-based cleaning agents or abrasive cleaners, but only
clean water to moisten the cloth.
Do not use a high-pressure cleaner!
Disposal
In the European Union, electronic equipment must not
be treated as domestic waste, but must be disposed of
professionally in accordance with Directive
2002/96/EC of the European Parliament and Council of 27th
January 2003 concerning old electrical and electronic equipment.
At the end of its life, please dispose of this device according to the
valid legal requirements.
7Operating Manual – Air Cleaner TAC 750 EEN
Page 9
Overview and list of spare parts
123
19
9251620813147
152210121811526317244
2126
Note!
The position numbers of the spare parts differ from those describing the positions
of other parts mentioned in this operating manual.
Declaration of conformity (Translation of the
original)
EC Declaration of Conformity
in accordance with EC Machinery Directive 2006/42/EC
TROTEC
®
GmbH & Co. KG
Grebbener Straße 7
D-52525 Heinsberg
herewith declares, that due to its design and construction, and in the version introduced by us,
the following machinery conforms with the relevant fundamental requirements of the listed EC
directives.
Important note:
In case of improper use, installation, maintenance etc. or unauthorized changes of the
factory-supplied device version, this declaration loses its legal validity.
Device version: Air Cleaner
Series: TAC 750 E
Yea r o f m a nu fa ct ur e: as of 09/2014
Applicable regulations: 2006/42/EC
2004/108/EC
2011/65/EC
Machinery Directive
EMC Directive
RoHS
Applied harmonised
standards:EN 60335-2-65:2003
EN 55014-1:2006
EN 13857:2008
EN 60204-1:2006
EN ISO 12100:2010
Producer and authorised representative of the technical documentation:
Trotec GmbH & Co. KG · Grebbener Straße 7 · D-52525 Heinsberg
Phone: +49 2452 962-400 · Fax: +49 2452 962-200 · E-mail: info@trotec.com
Heinsberg, 01/09/2014
9Operating Manual – Air Cleaner TAC 750 EEN
Managing Director: Detlef von der Lieck
Page 11
Page 12
Trotec GmbH & Co. KG
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
info@trotec.com
www.trotec.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.