Trotec T660 Operating Manual

T660
EN
OPERATING MANUAL
MATERIAL MOISTURE MEASURING DEVICE
TRT-BA-T660-TC-001-EN

Table of contents

Notes regarding the operating manual .................................... 1
Information about the device ................................................... 2
Technical data ........................................................................ 3
Safety ..................................................................................... 3
Transport and storage ............................................................. 4
Operation................................................................................ 4
Measuring principle ................................................................ 8
PC software ............................................................................ 9
Errors and faults ..................................................................... 10
Maintenance ........................................................................... 10
Disposal.................................................................................. 11
Declaration of conformity ........................................................ 11

Notes regarding the operating manual

Symbols

Danger!

Warns of a hazard which can lead to personal injury.

Caution!

Warns of a hazard which can lead to damage to prop­erty.

Warranty

The warranty is for 12 months. Damages caused by incorrect use by untrained people or start-up by unauthorised people are excluded from the warranty. The device complies with the fundamental health and safety requirements of the applicable EU regulations and was tested at the factory for perfect functionality multiple times. However, if faults in the functionality occur and cannot be remedied with the measures in the chapter Errors and faults, please get in touch with your dealer or distributor. When making a warranty claim, supply the device number (see the rear of the device). The invoice acts as warranty certificate. When manufacturer's instructions or legal regulations have not been followed, or after unauthorised changes to the device are made, the manufacturer is not respon­sible for the resulting damages. Changes to the device or unau­thorised replacement of individual parts can drastically impact the electrical safety of this product and leads to the forfeit of the warranty. Liability does not extend to damages to people or prop­erty caused by the device being used other than as described in the instructions in this operating manual. Subject to changes to technical design and model changes as part of constant develop­ment and product improvement without prior notice. No liability is accepted for damages resulting from improper use. In such cases, entitlements to a warranty are then also forfeited.
The current version of the operating manual can be found at: www.trotec.de

Legal notice

This release replaces all previous versions. No part of this publi­cation may be reproduced without written permission from TRO­TEC®. The same applies for electronically processing, duplicating or spreading the publication. Subject to technical changes. All rights reserved. Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer. Product names are registered. Changes to construction in the interests of constant improve­ments to the product, as well as changes to the shape and colour are reserved. The scope of delivery may vary from product images. This docu­ment was created with all due care. TROTEC whatsoever for possible mistakes or omissions. The only party responsible for determining measured results to be valid, drawing conclusions and deriving actions is the user! TROTEC® accepts no claims of warranty for the correctness of the determined measured values or measured results. Further, TROTEC
®
accepts no liability whatsoever for possible mistakes or damage which have been caused by utilising the determined measured results. © TROTEC
®
®
accepts no liability

Information about the device

1
2
6
3
45
7
8
11
10
9
TH HOLD
%WT
g/m
3
g/kg
Pabs[hPa]
SENS MAT TEMP Alarm
Alt.[ft] CAL12
gr/lb dp °C °F % rH
CM m/s ppm °F °C
IR
MAXDPMIN AVG
CFG ACT
14
16
15
12
13
17

Description of the device

The material moisture measuring device T660 is a dielectric humidity sensor, which can be used for the quick and non-destructive localization of humidity or moisture distributions. The device enables the detection of near-surface moisture in walls or flooring. The measured values will be displayed in real time. A minimum, maximum and average function is available for the direct analysis of the measured data. Besides, the currently measured value can be recorded via the hold function. The device further features an alarm function. Once the preset limit value is exceeded, the device alerts the user through emit­ting an acoustic signal! The device is suited for the preliminary check of the building materials' readiness for covering for subsequent measurements according to the calcium carbide method (CM measurement). The moisture indication allows the localization of the most significant measuring spots to extract material for the CM measurement. You can connect the device to a computer by using the USB cable included in the scope of delivery. Then you can extract and ana­lyse your measured results with the optional MultiMeasure Studio software.

Cross control

No. Operating element
7 Up key 8 Right/back key 9 Down key 10 OK button 11 Left/menu key

Device depiction

No. Operating element
1Display 2 Cross control 3 Battery compartment with battery cover 4 On/Off key 5USB interface 6 Measuring head

Display

No. Display element
12 Configuration mode display 13 Measuring mode 14 Measurement value display top 15 Display of the selected unit 16 Measurement value display bottom 17 Configuration mode options
EN Operating manual – Material moisture measuring de vice T660 2

Technical data

Parameter Value
Model T660 Dimensions (L x W x H) 209 mm x 63 mm x 35 mm Weight incl. batteries approx. 300 g Measuring range 0 to 200 digits
Operating range
Operating temperature 0 °C to +50 °C Relative humidity
Storage
Relative humidity < 95 % (non-condensing) Ambient temperature -20 °C to +60 °C
Energy
Battery 4 x Alkaline LR6 AA, 1.5 V batteries
Current consumption, active approx. 80 mA Current consumption, passive approx. 70 μA Battery life at least 30 h
<90% or <20g/m (non-condensing)
comparable NiMH rechargeable batteries (>2500 mAh)
3

Scope of delivery

The scope of delivery includes:
• 1 x Material moisture measuring device T660
• 1 x USB cable
• 4 x Alkaline LR6 AA, 1.5 V batteries
• 1 x Display protection film
• 1 x Getting started guide
• 1 x Factory test certificate

Safety

Carefully read the operating manual before using the device and keep it within reach!

Improper use

Do not use the device in potentially explosive atmospheres, or for measurements in liquids. TROTEC® accepts no liability for dam­ages resulting from improper use. In such a case, entitlements to a warranty are forfeited. Any unauthorised modifications, altera­tions or structural changes to the device are forbidden.

Personnel qualifications

People who use this device must:
• have read and understood the operating manual, especially the Safety chapter.
For maintenance or repair work which requires the housing
®
to be opened, contact TROTEC
customer service. Devices which have been opened unlawfully are void of any warranty and warranty claims.

Residual risks

Danger!

Do not leave the packaging lying around. Children may use it as a dangerous toy.

Danger!

The device is not a toy and does not belong in the hands of children.

Danger!

Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way. Observe the personnel qualifications.

Caution!

To prevent damages to the device, do not expose it to extreme temperatures, extreme humidity or moisture.
• Do not use the device in atmospheres containing oil, sulphur, chlorine or salt.
• Never use the device for measurements at live parts.
• Ensure that all connection cables are protected from damag­es (e.g. from kinks or crushing).
• Protect the device from permanent direct sunlight.
• Observe the storage and operating conditions (see chapter Technical data).

Intended use

Only use the material moisture measuring device T660 for the moisture measurement of building materials. Here, read and observe the technical data. To use the device for its intended use, only connect and use accessories and spare parts which have been approved by TROTEC
®
.

Caution!

Do not use abrasive cleaners or solvents to clean the device.
Loading...