T660
EN
OPERATING MANUAL
MATERIAL MOISTURE
MEASURING DEVICE
TRT-BA-T660-TC-001-EN

Table of contents
Notes regarding the operating manual .................................... 1
Information about the device ................................................... 2
Technical data ........................................................................ 3
Safety ..................................................................................... 3
Transport and storage ............................................................. 4
Operation................................................................................ 4
Measuring principle ................................................................ 8
PC software ............................................................................ 9
Errors and faults ..................................................................... 10
Maintenance ........................................................................... 10
Disposal.................................................................................. 11
Declaration of conformity ........................................................ 11
Notes regarding the operating manual
Symbols
Danger!
Warns of a hazard which can lead to personal injury.
Caution!
Warns of a hazard which can lead to damage to property.
Warranty
The warranty is for 12 months. Damages caused by incorrect use
by untrained people or start-up by unauthorised people are
excluded from the warranty.
The device complies with the fundamental health and safety
requirements of the applicable EU regulations and was tested at
the factory for perfect functionality multiple times. However, if
faults in the functionality occur and cannot be remedied with the
measures in the chapter Errors and faults, please get in touch
with your dealer or distributor. When making a warranty claim,
supply the device number (see the rear of the device). The invoice
acts as warranty certificate. When manufacturer's instructions or
legal regulations have not been followed, or after unauthorised
changes to the device are made, the manufacturer is not responsible for the resulting damages. Changes to the device or unauthorised replacement of individual parts can drastically impact
the electrical safety of this product and leads to the forfeit of the
warranty. Liability does not extend to damages to people or property caused by the device being used other than as described in
the instructions in this operating manual. Subject to changes to
technical design and model changes as part of constant development and product improvement without prior notice.
No liability is accepted for damages resulting from improper use.
In such cases, entitlements to a warranty are then also forfeited.
The current version of the operating manual can be found at:
www.trotec.de
Legal notice
This release replaces all previous versions. No part of this publication may be reproduced without written permission from TROTEC®. The same applies for electronically processing, duplicating
or spreading the publication. Subject to technical changes. All
rights reserved. Trademarks are used without guarantee that they
may be used freely and primarily following the spelling of the
manufacturer. Product names are registered.
Changes to construction in the interests of constant improvements to the product, as well as changes to the shape and colour
are reserved.
The scope of delivery may vary from product images. This document was created with all due care. TROTEC
whatsoever for possible mistakes or omissions.
The only party responsible for determining measured results to be
valid, drawing conclusions and deriving actions is the user!
TROTEC® accepts no claims of warranty for the correctness of
the determined measured values or measured results. Further,
TROTEC
®
accepts no liability whatsoever for possible mistakes or
damage which have been caused by utilising the determined
measured results. © TROTEC
®
®
accepts no liability
1 Operating manual – Mate rial moisture measur ing device T660 EN

Information about the device
TH
HOLD
%WT
g/m
3
g/kg
Pabs[hPa]
SENS MAT TEMP Alarm
Alt.[ft] CAL12
gr/lb dp °C °F % rH
CM m/s ppm °F °C
IR
MAXDPMIN AVG
CFG
ACT
Description of the device
The material moisture measuring device T660 is a dielectric
humidity sensor, which can be used for the quick and
non-destructive localization of humidity or moisture distributions.
The device enables the detection of near-surface moisture in
walls or flooring. The measured values will be displayed in real
time.
A minimum, maximum and average function is available for the
direct analysis of the measured data. Besides, the currently
measured value can be recorded via the hold function.
The device further features an alarm function. Once the preset
limit value is exceeded, the device alerts the user through emitting an acoustic signal!
The device is suited for the preliminary check of the building
materials' readiness for covering for subsequent measurements
according to the calcium carbide method (CM measurement). The
moisture indication allows the localization of the most significant
measuring spots to extract material for the CM measurement.
You can connect the device to a computer by using the USB cable
included in the scope of delivery. Then you can extract and analyse your measured results with the optional MultiMeasure Studio
software.
Cross control
No. Operating element
7 Up key
8 Right/back key
9 Down key
10 OK button
11 Left/menu key
Device depiction
No. Operating element
1Display
2 Cross control
3 Battery compartment with battery cover
4 On/Off key
5USB interface
6 Measuring head
Display
No. Display element
12 Configuration mode display
13 Measuring mode
14 Measurement value display top
15 Display of the selected unit
16 Measurement value display bottom
17 Configuration mode options
EN Operating manual – Material moisture measuring de vice T660 2

Technical data
Parameter Value
Model T660
Dimensions (L x W x H) 209 mm x 63 mm x 35 mm
Weight incl. batteries approx. 300 g
Measuring range 0 to 200 digits
Operating range
Operating temperature 0 °C to +50 °C
Relative humidity
Storage
Relative humidity < 95 % (non-condensing)
Ambient temperature -20 °C to +60 °C
Energy
Battery 4 x Alkaline LR6 AA, 1.5 V batteries
Current consumption, active approx. 80 mA
Current consumption, passive approx. 70 μA
Battery life at least 30 h
<90% or <20g/m
(non-condensing)
comparable NiMH rechargeable batteries
(>2500 mAh)
3
Scope of delivery
The scope of delivery includes:
• 1 x Material moisture measuring device T660
• 1 x USB cable
• 4 x Alkaline LR6 AA, 1.5 V batteries
• 1 x Display protection film
• 1 x Getting started guide
• 1 x Factory test certificate
Safety
Carefully read the operating manual before using the device
and keep it within reach!
Improper use
Do not use the device in potentially explosive atmospheres, or for
measurements in liquids. TROTEC® accepts no liability for damages resulting from improper use. In such a case, entitlements to
a warranty are forfeited. Any unauthorised modifications, alterations or structural changes to the device are forbidden.
Personnel qualifications
People who use this device must:
• have read and understood the operating manual, especially
the Safety chapter.
For maintenance or repair work which requires the housing
®
to be opened, contact TROTEC
customer service. Devices
which have been opened unlawfully are void of any warranty
and warranty claims.
Residual risks
Danger!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Danger!
The device is not a toy and does not belong in the hands
of children.
Danger!
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way.
Observe the personnel qualifications.
Caution!
To prevent damages to the device, do not expose it to
extreme temperatures, extreme humidity or moisture.
• Do not use the device in atmospheres containing oil, sulphur,
chlorine or salt.
• Never use the device for measurements at live parts.
• Ensure that all connection cables are protected from damages (e.g. from kinks or crushing).
• Protect the device from permanent direct sunlight.
• Observe the storage and operating conditions (see chapter
Technical data).
Intended use
Only use the material moisture measuring device T660 for the
moisture measurement of building materials.
Here, read and observe the technical data.
To use the device for its intended use, only connect and use
accessories and spare parts which have been approved by
TROTEC
®
.
Caution!
Do not use abrasive cleaners or solvents to clean the
device.
3 Operating manual – Mate rial moisture measur ing device T660 EN