Trotec PT 6500 S, PT 15000 S Original Instruction

PT 6500 S / PT 15000 S
EN
ORIGINAL INSTRUCTIONS
AIR CONDITIONER
TRT-BA-PT6500S/PT15000S-TC-001-EN

Table of contents

Follow the manual
Information marked with this symbol indicates that the instructions must be observed.
Operation .............................................................................12
Available accessories..........................................................13
Errors and faults..................................................................14
Maintenance ........................................................................16
Technical annex...................................................................21
Disposal ...............................................................................23
Declaration of conformity ...................................................23

Notes regarding the instructions

Wear safety glasses
Information marked with this symbol indicates that you should wear eye protection.
Wear a protective mask
Information marked with this symbol indicates that you should wear a protective mask.
Wear protective gloves
Information marked with this symbol indicates that you should wear protective gloves.
Wear foot protection
Information marked with this symbol indicates that you should wear safety boots.
You can download the current version of the instructions and the EUdeclaration of conformity via the following link:
PT 6500 S

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Danger
This symbol indicates dangers to the life and health of persons due to suspended loads.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
https://hub.trotec.com/?id=40996
PT 15000 S
https://hub.trotec.com/?id=42206
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
1 EN
air conditioner PT 6500 S / PT 15000 S

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Never drink the water/ glycol mixture! Dispose of the water/ glycol mixture properly!
Never fill the tank directly from a water line. Use a suitable vessel or other means.
Let the device dry out after a wet clean. Do not operate it when wet.
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
Do not sit on the device.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Observe the technical data when selecting extensions to the power cable. Completely unroll the extension cable. Avoid electrical overload.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk!
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
Make sure that the air inlet and outlet are not obstructed.
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
Make sure that the suction side is kept free of dirt and loose objects.
Discharge the collected condensate before transport and storage. Do not drink it. Health hazard!
Only transport the device in an upright position.

Intended use

Only use the device for cooling, ventilating and dehumidifying indoor air whilst adhering to the technical data.

Improper use

Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, such as alterations or structural changes to the device, are forbidden.
Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the instructions, especially the Safety chapter.
Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.
EN 2
air conditioner PT 6500 S / PT 15000 S
Electrically skilled person
Electrically skilled personnel must be able to read and understand electric circuit diagrams, to put electrical systems into service and to maintain them, to wire control cabinets, to ensure the functionality of electrical components and to identify possible hazards from electrical and electronic systems.

Personal protective equipment

Danger
Keep the water/ glycol mixture away from your eyes at all times! Should the water/ glycol mixture contact your eyes, immediately rinse them with clear water!
Danger
Never drink the water/ glycol mixture! Glycol is unfit for human consumption and harmful to health!
Wear safety glasses
For start-up, maintenance and troubleshooting always wear suitable safety glasses.
Wear a protective mask
For cleaning and maintenance tasks wear an appropriate protective mask.
Wear protective gloves
For start-up, maintenance and troubleshooting always wear suitable protective gloves.
Wear foot protection
For transportation, start-up, maintenance and troubleshooting always wear suitable foot protection.

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Note
To avoid damages to the device, only transport and operate the device in an upright position! It must neither be tilted nor laid down!
Note
Do not operate the device without an inserted air filter! Without an air filter the inside of the device will be heavily contaminated, which could reduce the dehumidification performance and result in damage to the device.

Behaviour in the event of an emergency

1. Switch off the device.
2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Warning
Risk of death due to suspended loads! Make sure that nobody is situated in the immediate proximity.
3 EN
air conditioner PT 6500 S / PT 15000 S

Information about the device

Device description

The devices PT6500S and PT15000S are chiefly used for cooling room air. Moreover, the devices also provide the opportunity of air circulation without cooling effect. The devices are operated via the control panel(1) at the respective device. The devices are air conditioners with split cooling circuits. The refrigerant circuit of the basic device(2) is self-contained. For the dissipation of warmth it is emitted via one or two heat exchangers to a second cooling circuit. A second circuit transports warmed water/ glycol mixture to the external heat exchanger(6) to cool it down again. The air conditioner PT6500S can be used with one heat exchanger, the more than twice as powerful model PT15000S needs two heat exchangers. The devices cool the room air by withdrawing warmth. The refrigerant cools down the air coming from the room and in doing so absorbs the heat. The thusly cooled air is introduced to the room, where the device is positioned, via the fan. Accumulating condensate is discharged via a separate hose(3,11) to the external heat exchanger in order to be drained or to evaporate there. The "operating hours counter" option is already integrated in the control of PT6500S and PT15000S. As standard the PT15000S comes with an installed energy meter. For the PT6500S you can optionally order a dual counter.
EN 4
air conditioner PT 6500 S / PT 15000 S

Device depiction

20
1
2
16
17
18
19
3
4
5
13
14
15
21
35
6
7
9
10
11
12
8
37
35 36
PT 6500 S
No. Operating element
1 control panel with integrated operating hours counter
2 basic device
3 condensation hose connection
4 line to the external heat exchanger
5 compensation tank with screw-on lid for water circuit
6 external heat exchanger
7 fan
8 spacer
9 mains connection external heat exchanger
10 connection for the line to the basic device
11 connection for the line from the basic device
12 condensation hose connection
13 line from the external heat exchanger
14 mains connection to external heat exchanger
15 mains connection with power plug
16 wheel with parking brake
17 carrying handle
18 air inlet with air filter
19 louvre and air outlet
20 transport handles
21 dual counter for operating hours and energy consumption
(MID-compliant) optional
35 earthing connection
36 protective earth conductor
37 vent valve for water circuit
5 EN
air conditioner PT 6500 S / PT 15000 S
PT 15000 S
20
1
2
16
17
18
19
3
5
13
15
4
4
13
14
14
21
35
35
6
7
9
10
11
12
38
37
35
No. Operating element
1 control panel with integrated operating hours counter
2 basic device
3 condensation hose connection
4 line to the external heat exchanger
5 compensation tank with screw-on lid for water circuit
6 external heat exchanger
7 fan
9 mains connection external heat exchanger
10 connection for the line to the basic device
11 connection for the line from the basic device
12 condensation hose connection
13 line from the external heat exchanger
14 mains connection to external heat exchanger
15 mains connection with power plug
16 wheel with parking brake
17 carrying handle
18 air inlet with air filter
19 louvre and air outlet
20 transport handles
21 energy meter (MID-compliant)
35 earthing connection
37 vent valve for water circuit
38 adjustable spacer for device protection
EN 6
air conditioner PT 6500 S / PT 15000 S

Transport and storage

Note
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

To make the device easier to transport, it is fitted with wheels. To make the device easier to transport, it is fitted with a carry
handle.
Wear foot protection
For transportation, start-up, maintenance and troubleshooting always wear suitable foot protection.
Always utilize the help of another person to transport the device. Do not try to transport the device without the help of another person. To lift the device, use a forklift or an elevating truck as appropriate.
Before transporting the device, observe the following:
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Do not use the power cable to drag the device.
Disconnect the connection to the external unit.
Release the brakes at the castors.
Only wheel the device on a level and smooth surface.
While transporting the device, observe the following:
Only transport the device in an upright position.
Only hold the basic device by the transport handles when wheeling the device.
Use the carrying handles to carry the basic device. Always utilize the help of another person to carry the device.
After transporting the device, observe the following:
Set up the device in an upright position after transport.
Apply and lock the brakes at the wheels again.
Transportation by crane – crane lugs (optional)
Danger
Suspended loads!
Risk of death due to falling loads.
Proceed with the utmost care when lifting loads and putting them down.
Only use the crane lugs specified in the instructions (see chapter Available accessories).
Regularly check the crane lugs for wear.
Ensure the unobstructed view of the load during your work.
Never stand underneath suspended loads or in their immediate vicinity.
Keep other persons away from the danger area. Make use of suitable barriers or assign supervisors.
When setting the load down, avoid touching close-by objects and a resulting inclined position.
Always lift the loads vertically off the ground. Any inclination is prohibited due to the associated risk of accidents.
Never exceed the permissible load-carrying capacity of the employed lifting equipment.
Wear foot protection
For transportation, start-up, maintenance and troubleshooting always wear suitable foot protection.
7 EN
air conditioner PT 6500 S / PT 15000 S
Loading...
+ 18 hidden pages