Trotec PAE 51 Operating Manual

Page 1
PAE 51
EN
OPERATING MANUAL
AIR COOLER
TRT-BA-PAE51-TC-001-EN
Page 2

Table of contents

You can download the current version of the operating manual and the EU declaration of conformity via the following link:

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
PAE 51
https://hub.trotec.com/?id=42017

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Let the device dry out after a wet clean. Do not operate it when wet.
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
Do not sit on the device.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
1 EN
Operating manual – air cooler PAE 51
Page 3
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk.
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
Ensure that the air inlet and outlet are not obstructed.
Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects.
Only transport the device in an upright position with an emptied water tank.
Empty the water tank before transport and storage. Do not drink the water. Health hazard!
Only fill the water tank with fresh drinking water, ice cubes made of fresh drinking water and/ or suitable ice packs.
Ice packs are not toys. Keep away from children and animals.
Never open an ice pack. The liquid inside the ice packs can be harmful to health.
Do not eat the ice that may form on the ice packs. Health hazard!

Intended use

Only use the device for cooling the air in interior spaces while adhering to and following the technical data.
Intended use comprises cooling the air in:
living spaces
museums
warehouses and archives
libraries
call centres and computer rooms

Improper use

Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, alterations or structural changes to the device are forbidden.
Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the operating manual, especially the Safety chapter.
Maintenance tasks which require the housing to be opened must only be carried out by specialist electrical companies or by Trotec.

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
The liquid inside the ice packs can be harmful to health! If the liquid was swallowed, immediately seek medical attention. If the liquid came into contact with your eyes, rinse with water and immediately consult an ophthalmologist.
EN 2
Operating manual – air cooler PAE 51
Page 4
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

Behaviour in the event of an emergency

1. Switch the device off.
2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
3. Do not reconnect a defective device to the mains.

Information about the device

Description of the device

The air cooler lowers the room temperature to a comfortable degree by evaporation-based cooling.
The device is filled with cold water or optionally with ice cubes and/or ice packs in order to cool down the incoming warm air at the evaporation filter and to blow out the cold air thus generated via the fan.
Besides its cooling function, the device can also be used for air freshening: thanks to an integrated air filter and the evaporation filter's honeycomb structure, the sucked-in air is filtered and humidified.
The fan speed can be set to four stages.
The discharge direction of the cooled air can be manually adjusted via the ventilation flaps as well as via the optionally selectable automatic swing mode.
The device has a night mode enabling ultra-silent operation at bedtime.
The device can be operated via the control panel at the device or via the infrared remote control.
Moreover, using the timer function, the device can be switched off automatically with time delay.
The device can be operated in an energy-efficient manner. If none of the operating elements have been actuated for a period of 60s, the LEDs are automatically dimmed.
3 EN
Operating manual – air cooler PAE 51
Page 5

Device depiction

1
2
3
4
5
6
7
13
7
13
14
15
16
12
9
10
8
11
No. Designation
1 Control panel
2 Air outlet with adjustable ventilation flaps and air
flaps for swing function
3 Water tank with filling level indicator
4 Wheels with parking brake
5 Compartment for remote control
6 Air inlet with air filter and honeycomb filter
7 Power cable holder
8 Honeycomb filter
9 Ice pack
10 Remote control
11 Air filter
12 Stopper for slider
13 Locking clasp for water tank
14 Slider for pump
15 Remote control receiver
16 Water funnel
Please note the warnings on the labels attached to the device.
EN 4
Operating manual – air cooler PAE 51
Page 6

Transport and storage

A
B
C
C
D

Assembly and start-up

Note
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

To make the device easier to transport, it is fitted with wheels.
Before transporting the device, observe the following:
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Empty the water tank.
Do not use the power cable to drag the device.
Release the brakes at the castors.
Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
Set up the device in an upright position after transport.

Storage

Before storing the device, observe the following:
Empty and clean the water tank prior to storage (see chapter Maintenance).
Allow the honeycomb filter to dry prior to storage. Otherwise the device may distribute a musty smell after restart.
When the device is not being used, observe the following storage conditions:
dry and protected from frost and heat
in an upright position where it is protected from dust and direct sunlight
with a cover to protect it from invasive dust if necessary
Place no further devices or objects on top of the device to prevent it from being damaged.
Remove batteries from the remote control.

Scope of delivery

1x Device
1 x Remote control
1 x Battery for the remote control
1x Honeycomb filter
1x Air filter
1 x Ice pack
1x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.

Start-up

When positioning the device, observe the minimum distance from walls or other objects as described in the Technical data chapter.
Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service.
Set the device up in an upright and stable position.
Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges.
5 EN
Operating manual – air cooler PAE 51
Page 7
Make sure that extension cables are completely unrolled.
Make sure that no curtains or other objects interfere with the air flow.
Prior to initial start-up, insert the batteries in the remote control.
Wheels
To ensure simple transportation the device comes equipped with wheels. Moreover, two of the wheels are fitted with a parking brake to ensure a firmly fixed position. Please proceed as follows to apply or release the parking brakes:
To facilitate easy transport, release the parking brakes.
Info
If possible, change the water on a daily basis to prevent bacterial growth.
Observe the following when using the ice pack:
Put the ice pack into a freezer for at least 4hours before use.
The water tank(3) should be filled with water before positioning the ice pack.
Info
When using ice packs at high outside temperatures, condensation may form at the water tank and drip onto the floor.
1. Disconnect the device from the mains before refilling water or putting ice packs into the device.
2. There are two ways to fill water into the tank. Choose option2 if you want to add ice cubes or ice packs for additional cooling.
ð Option1:
Open the water funnel(16).
To ensure a firmly fixed position, apply the parking brakes.
Filling the water tank
The device requires fresh drinking water for air cooling.
Note
Fill the device with fresh drinking water only. The water temperature must not exceed 40°C.
ð Option2:
Make sure that the slider(14) is secured in the upper position. Undo the locking clasps(13) and lift off the top section of the device.
EN 6
Operating manual – air cooler PAE 51
Page 8
3. Fill the water tank(3) with fresh drinking water only. Optionally, you can add ice cubes made of drinking water for additional cooling.
ð Observe the minimum and maximum filling level at the
filling level indicator. The water tank must be filled up to minimum filling level to enable pump operation.
4. If required, put the ice pack into the water tank(3) for additional cooling.
Adjusting the position of the slider
After having filled the water tank, insert the pump in the water tank in order to use the air cooling function.
1. Remove the stopper from the upper position of the slider(14) at the device.
5. Close the flap for the water funnel(16) or put the upper section back onto the water tank and shut the locking clasps(13).
6. Make sure that the device is neither damp nor wet on the outside. Otherwise wipe it dry.
2. Push the slider(14) down.
Note
Always secure the slider in its upper position by means of the stopper before lifting off the top section of the device. Otherwise the pump and the mechanism might be damaged.
7 EN
Operating manual – air cooler PAE 51
Page 9
Inserting honeycomb filter and air filter
17 18 19
20
21
22
23
24
25
262728
29
30
Note
When set to air cooling mode, the device should not be operated without the honeycomb filter, otherwise cooling will not work.
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
Make sure that both the honeycomb and the air filter are installed before switching the device on.
Adjusting the ventilation flaps
Prior to switching the device on, adjust the ventilation flaps at the air outlet.
Connecting the power cable
Insert the mains plug into a properly secured mains socket.
Info
An acoustic signal will be emitted; the device is now in standby mode.

Operation

Avoid open doors and windows.
Operating elements
No. Designation Meaning
17 Cooling/
Humidification button
18 Cooling/
Humidification LED
19 Hours LEDs Indication of the number of hours
20 Ventilation LED Illuminated when ventilation mode
21 Air freshening LED Illuminated when air freshening
22 Night mode LED Illuminated when night mode is
23 Mode button Selection button for ventilation, air
24 Timer button Switching the timer on or off
25 Speed button Setting the fan speed and the filter
26 Fan stage LEDs
27 On / Off LED Illuminated during operation
28 Oscillation LED Illuminated when swing function
29 On / Off button Switching the device on or off
30 Oscillation button Switching the swing function on
Switching the air cooling mode on or off
Illuminated when air cooling mode is activated
of the activated timer 1h, 2h, 4h and 8h
is activated
mode is activated
activated
freshening and night mode
drying function
Fan speed indication is illuminated: Silent stage = ultra-silent operation Stage 1 = low
I
Stage 2 = medium
II
Stage 3 = high
III
is activated
or off
EN 8
Operating manual – air cooler PAE 51
Page 10
Switching the device on
Once you have completely installed the device as described in the Start-up chapter, you can switch it on.
1. Press the On / Off button(29).
ð The device starts in ventilation mode at fan stageII. ð The LEDs On/ Off(27), Ventilation(20) and Fan stageII(26)
are illuminated.
Setting the operating mode
The device comes with the following operating modes:
air cooling
ventilation
air freshening
night mode
Air cooling
The air cooling mode can be switched on in addition during all other operating modes.
During air cooling the pump is switched on and the water is distributed over the honeycomb filter to cool the circulating air. If the water tank is empty, an acoustic signal will be emitted.
Please proceed as follows to activate air cooling:
1. Press the Cooling/ Humidification button(17).
ð The Cooling/ Humidification LED(18) is illuminated. ð The pump starts.
2. Press the Speed button(25) to set the desired fan stage (Silent and 1 to3).
3. Press the Cooling/ Humidification button(17) again to switch air cooling off.
ð The Cooling/ Humidification LED(18) goes out. ð The device continues to run in the previously selected
operating mode.
Note
When air cooling mode is activated, the air and honeycomb filter must not be removed, otherwise the water from the filter will drip down into the device.
Air freshening
In air freshening mode, the fan speed increases and decreases alternately to generate a pleasant, natural air stream.
Please proceed as follows to activate air freshening:
1. Press the Mode button(23) until the Air freshening LED(21) is illuminated. The fan stages are automatically adjusted.
Activating night mode
In night mode, it is possible to additionally switch on air cooling.
Air freshening cannot be activated.
In night mode, the device operates using a preset programme with different fan speeds to generate an air stream that is adapted to human sleeping habits.
1. Press the Mode button(23) until the Night mode LED(22) is illuminated.
Setting the timer
Using the timer function, the device can be switched off automatically after a preset number of hours.
The function can be set in all operating modes.
The number of hours can be set to 1h, 2h, 4h or 8h.
Automatic switch-off
ü The device is switched on.
1. Press the Timer button(24) until the desired number of hours is displayed by the Hours LEDs(19).
ð The timer setting equals the desired number of hours. ð The device switches off automatically after the set number
of hours has elapsed.
Notes regarding automatic switch-off:
Pressing the On/ Off button(27) does not deactivate the automatic switch-off function.
A power failure during operation does not deactivate the automatic switch-off function.
Ventilation
In ventilation mode, you can select all 4fan speeds manually.
Please proceed as follows to activate ventilation:
1. Press the Mode button(23) until the Ventilation LED(20) is illuminated.
2. To adjust the fan stage, press the Speed button(25) until the LED for the desired fan stage(26) is illuminated.
Note
The Silent fan stage can only be selected in ventilation mode, possibly combined with air cooling.
9 EN
Operating manual – air cooler PAE 51
Page 11
Remote control
29
25
30
24
17
23
31
All settings of the device can also be made using the remote control included in the scope of delivery.
No. Designation Meaning
17 Cooling/
Humidification button
Switching the air cooling mode on or off
23 Mode button Selection button for ventilation, air
freshening or night mode
24 Timer button Switching the timer on or off
25 Speed button Setting the fan speed
29 On / Off button Switching the device on or off
30 Oscillation button Switching the swing function on
or off
31 Remote control
transmitter/receiver
For infrared transmission to the device
Auto stop function
If the water tank is empty and air cooling activated, an acoustic warning signal will be emitted and the Cooling/ Humidification LED(18) goes out. The pump switches off automatically after 50s.
A float switch provides further overflow protection and prevents water from exiting through water funnel(16). Upon reaching a certain filling level in the water funnel(16), the pump switches off after 5s and an acoustic warning signal will be emitted.
Refilling water
An empty water tank is indicated by the device with an acoustic warning signal. In this case, the water tank must be refilled.
Observe the following when using the ice pack:
Put the ice pack into a freezer for at least 4hours before use.
The water tank(3) should be filled with water before positioning the ice pack.
Info
When using ice packs at high outside temperatures, condensation may form at the water tank and drip onto the floor.
1. Disconnect the device from the mains before refilling water or putting ice packs into the device.
2. There are two ways to fill water into the tank. Choose option2 if you want to add ice cubes or ice packs for additional cooling.
ð Option1:
Open the water funnel(16).
Swing function
The swing function can be switched on in any operating mode if required.
Behind the horizontal ventilation flaps, there are vertical air flaps integrated in the device. By means of the swing function, these air flaps are moved automatically and thus ensure continuous air circulation.
1. Press the Oscillation button(30) to switch the swing function on or off.
ð With activated swing function the OscillationLED(28) is
illuminated.
Memory function
If a power failure has occurred during operation, an acoustic warning signal will be emitted and the device will automatically be switched back on.
If you switch the device back on from standby, a perhaps previously set timer and fan stage will have been stored by the device which starts in ventilation mode.
EN 10
Operating manual – air cooler PAE 51
Page 12
ð Option2:
Make sure that the slider(14) is secured in the upper position. Undo the locking clasps(13) and lift off the top section of the device.
3. Fill the water tank(3) with fresh drinking water only. Optionally, you can add ice cubes made of drinking water for additional cooling.
ð Observe the minimum and maximum filling level at the
filling level indicator. The water tank must be filled up to minimum filling level to enable pump operation.
Filter drying function
The filter drying function can be switched on in addition as needed, e.g. for transport purposes.
The fan runs at the maximum speed and the device will be switched off after 20minutes. No other function may be selected in this mode.
1. Press and hold the Speed button(25) for 3s to activate the filter drying function.
ð The Fan stageIII LED(26) flashes.
Note
To terminate the filter drying function prematurely, switch the device off by means of the On/ Off button(29).
Automatic switch-off function
After 15hours of continuous operation the device switches off automatically.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Empty and clean the water tank (see chapter Maintenance).
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
4. If required, put the ice pack into the water tank(3) for additional cooling.
5. Close the flap for the water funnel(16) or put the upper section back onto the water tank and shut the locking clasps(13).
6. Make sure that the device is neither damp nor wet on the outside. Otherwise wipe it dry.

Available accessories

Warning
Only use accessories and additional equipment specified in the operating manual. Using insertion tools or accessories other than those specified in the operating manual may cause a risk of injury.
Designation Article number
Evaporation filter PAE 51 7.710.000.855
11 EN
Operating manual – air cooler PAE 51
Page 13

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Wait for 10minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec.
The device works with reduced or no capacity:
Check the position of the horizontal ventilation flaps. They should be opened to the maximum.
Check the air filter for dirt. If necessary, clean or replace the air filter.
Check the minimum distance to walls or other objects. Position the device a little more in the room's centre if required.
The device is running, but there is no air cooling or pump operation:
Check whether air cooling mode is activated. The operating light should be illuminated.
Check the filling level of the water tank (see chapter Filling the water tank). The operating lightmust not be flashing and there must be no acoustic signal.
Check whether there are any objects blocking the pump inlet. Make sure that the pump inlet is not blocked.
In case the pump does not operate despite a correctly filled water tank and activated air cooling mode, the pump might be defective. Please contact the customer service.
Water is leaking:
Check the device for leaks.
Check the water tank for tight fit.
The swing function is not working:
The swing function motor might be defective. Please contact the customer service.
The device does not respond to the infrared remote control:
Check whether the distance between remote control and device is too large and reduce it if necessary.
Make sure there are no obstacles, such as furniture or walls, between the device and the remote control. Ensure visual contact between device and remote control.
Check the charging status of the batteries and change them if required.
If the batteries have only just been changed, check them for correct polarity and change them if required.
Note
Wait for at least 3 minutes after maintenance and repair work. Only then switch the device back on.
Your device still does not operate correctly after these checks?
Please contact the customer service. If necessary, bring the device to an authorized specialist electrical company or to Trotec for repair.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright position.
EN 12
Operating manual – air cooler PAE 51
Page 14

Maintenance

Maintenance intervals

Maintenance and care interval before every
start-up
Clean the water tank
Check the air inlets and outlets for
X X
X X
dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and
X X
foreign objects and clean if necessary
Replace the honeycomb filter
Check for damage
X
Check the attachment screws
Test run

Maintenance and care log

Device type: .............................................
as needed at least every
2 weeks
X X
X X
X
X X
at least every 4 weeks
at least every 6 months
Device number: ....................................
at least annually
X
Maintenance and care interval
Clean the water tank
Check the air inlets and outlets for dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and foreign objects and clean if necessary
Replace the honeycomb filter
Check for damage
Check the attachment screws
Test run
Remarks:
1. Date: ................................
Signature: ............................
5. Date: ................................
Signature: ............................
9. Date: ................................
Signature: ............................
13. Date: ..............................
Signature: ............................
2. Date: ................................
Signature: ............................
6. Date: ................................
Signature: ............................
10. Date: ..............................
Signature: ............................
14. Date: ..............................
Signature: ............................
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
3. Date: ................................
Signature: ............................
7. Date: ................................
Signature: ............................
11. Date: ..............................
Signature: ............................
15. Date: ..............................
Signature: ............................
4. Date: ................................
Signature: ............................
8. Date: ................................
Signature: ............................
12. Date: ..............................
Signature: ............................
16. Date: ..............................
Signature: ............................
13 EN
Operating manual – air cooler PAE 51
Page 15

Activities required before starting maintenance

Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist electrical company or by Trotec.
5. Put the air filter back in.

Cleaning the water tank

The water tank should be cleaned every two weeks.
Before a longer period of non-use or storage the water tank should be drained.
1. Make sure that the slider(14) is secured in the upper position.
2. Open the locking clasps(13) at the device.

Cleaning the housing

Clean the device with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth.
3. Lift off the top section of the device.
4. Thoroughly rinse the water tank in a sink or similar.
5. Clean the tank using a mild cleaning agent (no detergent!).
6. Remove all calcium deposits in the water tank.
7. Dry the inside of the tank with a lint-free cloth.
8. Fill the water tank with fresh drinking water if you want to continue operation (see chapter Adding water).
EN 14
Operating manual – air cooler PAE 51
Page 16
9. Put the upper section of the device back onto the water tank.
10. Close the locking clasps at the device.

Cleaning the air filter

The air filter has to be cleaned as soon as it is dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults).
Warning
Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be deformed or rounded. Before reinserting the air filter, make sure that it is undamaged and dry!
1. Loosen the screw at the air filter.
3. Clean the filter using a slightly damp, soft, lint-free cloth. If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent.
4. Allow the filter to dry completely. Do not insert a wet filter into the device!
5. Reinsert the air filter into the device.
6. Reattach the screw to the device.
2. Remove the air filter from the device.
15 EN
Operating manual – air cooler PAE 51
Page 17

Replacing the honeycomb filter

Note
When set to air cooling mode, the device should not be operated without the honeycomb filter, otherwise cooling will not work.
Note
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.
The honeycomb filter should be replaced in case of heavy soiling.
In standard operation, the interval for replacing the honeycomb filter is approx. 1 year.
Allow the honeycomb filter to dry before removing it from the device.
1. Loosen the screw at the air filter.
3. Remove the honeycomb filter from the device.
4. Dispose of used honeycomb filters according to the national regulations.
5. Insert the new honeycomb filter into the device.
2. Remove the air filter from the device.
EN 16
Operating manual – air cooler PAE 51
Page 18
6. Reinsert the air filter into the device.
7. Reattach the screw to the device.

Technical annex

Technical data

Parameter Value
Model PAE 51
Evaporation capacity 2000 ml/h
Air flow rate 661 m3/h
Mains supply 220-240V/ 50Hz
Nominal current consumption 0.48 A
Power consumption 110 W
Sound pressure level (1m distance)
Water tank capacity 20 l
Weight 8 kg
Dimensions (lengthx widthx height)
Minimum distance to walls and other objects:
top (A):
rear (B):
sides (C):
front (D):
60 dB(A)
390 x 342 x 897 mm
100 cm 100 cm 100 cm 100 cm

Activities required after maintenance

If you want to continue using the device:
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
Store the device according to the Storage chapter.

Disposal

The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
In the European Union, batteries and accumulators must not be treated as domestic waste, but must be disposed of professionally in accordance with Directive 2006/66/EC of the European Parliament and of the Council of 6September 2006 on batteries and accumulators. Please dispose of batteries and accumulators according to the relevant legal requirements.
17 EN
Operating manual – air cooler PAE 51
Page 19
Page 20
Trotec GmbH & Co. KG
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400 +49 2452 962-200
info@trotec.com www.trotec.com
Loading...