PAE 50
https://hub.trotec.com/?id=41851
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
•Do not use the device in potentially explosive rooms.
•Do not use the device in aggressive atmosphere.
•Set the device up in an upright and stable position.
•Let the device dry out after a wet clean. Do not operate it
when wet.
•Do not use the device with wet or damp hands.
•Do not expose the device to directly squirting water.
•Never insert any objects or limbs into the device.
•Do not cover or transport the device during operation.
•Do not sit on the device.
•This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
•Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.
1EN
Operating manual – air cooler PAE 50
•Ensure that all electric cables outside of the device are
MAX
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
•The electrical connection must correspond to the
specifications in chapter Technical data.
•Insert the mains plug into a properly secured mains
socket.
•Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.
•Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
•Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
•Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk.
•When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.
•Ensure that the air inlet and outlet are not obstructed.
•Ensure that the side of the device where the air inlet is
found is kept free of dirt and loose objects.
•Only transport the device in an upright position with an
emptied water tank.
•Empty the water tank before transport and storage. Do not
drink the water. Health hazard!
•Only fill the water tank with fresh drinking water, ice cubes
made of fresh drinking water and/ or suitable ice packs.
•Ice packs are not toys. Keep away from children and
animals.
•Never open an ice pack. The liquid inside the ice packs
can be harmful to health.
•Do not eat the ice that may form on the ice packs. Health
hazard!
Intended use
Only use the device for cooling the air in interior spaces while
adhering to and following the technical data.
Intended use comprises cooling the air in:
•living spaces
•museums
•warehouses and archives
•libraries
•call centres and computer rooms
Improper use
•Do not place the device on wet or flooded ground.
•Do not place any objects, e.g. clothing, on the device.
•Do not use the device outdoors.
•Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
•Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
Personnel qualifications
People who use this device must:
•be aware of the dangers that occur when working with
electric devices in damp areas.
•have read and understood the operating manual, especially
the Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist electrical companies or by
Trotec.
Symbols on the device
SymbolsMeaning
The symbols located on the device indicate that
you have to pay attention to the filling level
indication at the front of the device when filling the
water tank with drinking water. The water must
not exceed the maximum filling level.
Disconnect the device from the mains before
refilling water or putting ice packs into the device.
EN2
Operating manual – air cooler PAE 50
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
The liquid inside the ice packs can be harmful to
health!
If the liquid was swallowed, immediately seek medical
attention.
If the liquid came into contact with your eyes, rinse
with water and immediately consult an
ophthalmologist.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Information about the device
Description of the device
The air cooler lowers the room temperature to a comfortable
degree by evaporation-based cooling.
The device is filled with cold water or optionally with ice cubes
and/or ice packs in order to cool down the incoming warm air
at the evaporation filter and to blow out the cold air thus
generated via the fan.
Besides its cooling function, the device can also be used for air
freshening: thanks to an integrated air filter and the evaporation
filter's honeycomb structure, the sucked-in air is filtered and
humidified.
The fan speed can be set to four stages.
The discharge direction of the cooled air can be manually
adjusted via the ventilation flaps as well as via the optionally
selectable automatic swing mode.
The device has a night mode enabling ultra-silent operation at
bedtime.
The device can be operated via the control panel at the device
or via the infrared remote control.
Additionally, the device comes equipped with an ionizer which
eliminates odours and bacteria from the room air, if required.
The device is equipped with a scented oil tank for optimal room
air aromatization.
Continuous operation is enabled by a permanent water
connection.
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
Behaviour in the event of an emergency
1. Switch the device off.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
3EN
Operating manual – air cooler PAE 50
Device depiction
1
2
3
4
2
4
10
11
12
13
14
15
16
7
9
5
6
8
No.Designation
1Control panel
2Transport handle
3Water funnel
4Wheels
5Honeycomb filter
6Ice packs
7Power cable holder
8Remote control
9Air filter
10Water outlet with rubber stopper
11Water tank
12Hose connection for continuous operation with cover
13Air inlet with air filter and honeycomb filter
14Water level indicator
15Air outlet with adjustable ventilation flaps and air
flaps for swing function
16Remote control receiver
Please note the warnings on the labels attached to the device.
EN4
Operating manual – air cooler PAE 50
Transport and storage
A
B
C
C
D
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
To make the device easier to transport, it is fitted with wheels.
Before transporting the device, observe the following:
•Switch the device off.
•Hold onto the mains plug while pulling the power cable out
of the mains socket.
•Empty the water tank.
•Do not use the power cable to drag the device.
•Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
•Set up the device in an upright position after transport.
Storage
Before storing the device, observe the following:
•Empty and clean the water tank prior to storage (see
chapter Maintenance).
•Allow the honeycomb filter to dry prior to storage.
Otherwise the device may distribute a musty smell after
restart.
When the device is not being used, observe the following
storage conditions:
•dry and protected from frost and heat
•in an upright position where it is protected from dust and
direct sunlight
•with a cover to protect it from invasive dust if necessary
•Place no further devices or objects on top of the device to
prevent it from being damaged.
•Remove batteries from the remote control.
•1 x Permanent water connection hose with check valve,
length 1.5 m
•1x Hose adapter
•1 x Scented oil tank
•1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the Technical data
chapter.
Assembly and start-up
Scope of delivery
•1x Device
•1 x Remote control
•1 x Battery for the remote control
•1x Honeycomb filter
•1x Air filter
•4 x Ice pack
•4 x Foot
•4 x Screw for foot assembly
5EN
Operating manual – air cooler PAE 50
•Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
•Set the device up in an upright and stable position.
•Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
•Make sure that extension cables are completely unrolled.
•Make sure that no curtains or other objects interfere with
the air flow.
Prior to initial start-up, insert the batteries in the remote control.
Mounting the feet
1.
2.
If you want to position and operate the device on a slope, first
mount the feet.
1. Place the device on its side and position the feet.
Filling the water tank
The device requires fresh drinking water for air cooling.
Note
Fill the device with fresh drinking water only. The
water temperature must not exceed 40°C.
Info
If possible, change the water on a daily basis to
prevent bacterial growth.
Observe the following when using the ice packs:
•Put the ice packs into a freezer for at least 4hours before
use.
•The water tank(11) should be filled with water before
inserting the ice packs.
Info
When using ice packs at high outside temperatures,
condensation may form at the water tank and drip onto
the floor.
1. Disconnect the device from the mains before refilling water
or putting ice packs into the device.
2. Open the water funnel(3).
2. Fasten each foot on the device with one screw.
3. Ensure tight fit of the rubber stopper(10), for otherwise
there might be uncontrollable water leakage.
EN6
Operating manual – air cooler PAE 50
4. Fill the water tank(11) with fresh drinking water only.
Optionally, you can add ice cubes made of drinking water
for additional cooling.
ð Observe the minimum and maximum filling level at the
filling level indicator.
The water tank must be filled up to minimum filling level
to enable pump operation.
Inserting honeycomb filter and air filter
Note
When set to air cooling mode, the device should not be
operated without the honeycomb filter, otherwise
cooling will not work.
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
•Make sure that both the honeycomb and the air filter are
installed before switching the device on.
5. If required, put the ice packs into the water tank(11) for
additional cooling. The ice packs can be inserted in two
ways.
ð Version 1: Insert the ice packs into the device through
the water funnel.
ð Version 2: Remove the honeycomb filter(5) and the air
filter(9) at the rear of the device and insert the ice
packs.
Adjusting the ventilation flaps
•Prior to switching the device on, adjust the ventilation flaps
at the air outlet.
6. Close the flap of the water funnel(3) or reinsert the
honeycomb filter(5) and the air filter(9).
7. Make sure that the device is neither damp nor wet on the
outside. Otherwise wipe it dry.
7EN
Operating manual – air cooler PAE 50
Scent option
17
Additionally, the device offers the possibility to distribute a scent
during operation.
Note
Put scented oil into the designated scented oil
tank(17) only.
Use standard scented oil. Proceed as follows to use the scent
option:
ü The device is switched off and the power cable is
disconnected from the mains.
1. Slide the scented oil tank out of the holder and put 2 to 3
drops of scented oil into the scented oil tank.
Permanent water connection
If you use the device for an extended period of time or you do
not want to fill the water tank all the time, you can connect a
permanent water connection hose to the hose connection(12).
Note
Once you have disassembled the supplied hose into its
individual components, this hose must no longer be
used.
Please observe the water inlet pressure ranging
between 0.1MPa (min.) and 0.4MPa (max.). The water
temperature should be below 25°C.
ü The device is switched off and disconnected from the
mains.
ü When filling the water tank with drinking water, please pay
attention to the filling level indication at the front of the
device. The water must not exceed the maximum filling
level.
2. Push the scented oil tankback into the holder.
3. Attach the scented oil tank(17) to the device.
1. Open the hose connection cover(12).
2. Connect the supplied permanent water connection hose to
the hose connection(12). Pay attention to the correct
direction of connection.
3. Guide the other hose end to a suitable water connection.
The permanent water connection hose must not be kinked.
Connecting the power cable
•Insert the mains plug into a properly secured mains
socket.
Info
When connecting the power cable, an acoustic signal
is emitted and the LEDs on the control panel briefly
light up in red or white. The On / OffLED(23) will then
be permanently illuminated in red in standby mode.
EN8
Operating manual – air cooler PAE 50
Operation
1819
20
21
22
232425
26
27
28293031323334
•Avoid open doors and windows.
Operating elements
No.DesignationMeaning
18Air freshening LEDIlluminated white when air
freshening mode is activated
19Night mode LEDIlluminated white when night
mode is activated
20Fan stage LEDsFan speed indication is illuminated
white:
Stage 1 = low
Stage 2 = medium
Stage 3 = high
Stage 4 = maximum
21Swing function LEDIlluminated white when swing
function is activated
22Filter reset LEDFlashes red as a reminder to clean
the filters after 200operating
hours
23On / Off LEDIlluminated red when the power
cable is connected
24Ionizer LEDIlluminated white when ionizer
25Hours LEDsIlluminated white when timer for
26Ventilation LEDIlluminated white when ventilation
function is activated
automatic switch-on or switch-off
is activated
Indication of the number of hours
of the activated timer 1h, 2h, 4h
and 8h
mode is activated
No.DesignationMeaning
27Humidity LEDIlluminated white when air cooling
mode is activated
Flashes when water tank is empty
28Humidity buttonSwitching the air cooling mode on
or off
29Mode buttonSelection button for air freshening,
ventilation and night mode
30Timer buttonSwitching the timer function on or
off:
1h, 2h, 4h, 8h
31Ionizer buttonSwitching the ionization mode on
or off
32Swing buttonSwitching the swing function on
or off
33Speed buttonSetting the fan speed
34On / Off buttonSwitching the device on or off
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Press the On / Off button(34).
ð The device starts in ventilation mode at fan stage1.
ð The LEDs ventilation(26) and fan stage1(20) light up
white.
ð The On/ Off LED(23) is illuminated in red.
Setting the operating mode
The device comes with the following operating modes:
•air cooling
•air freshening
•ventilation
Air cooling
The air cooling mode can be switched on in addition during all
other operating modes.
During air cooling the pump is switched on and the water is
distributed over the honeycomb filter to cool the circulating air.
If the water tank is empty, the Humidity LED (27) flashes.
Please proceed as follows to activate air cooling:
1. Press the Humidity button(28).
ð The Humidity LED(27) lights up white.
ð The pump starts.
2. Press the Speed button(33) to set the desired fan stage (1
to4).
3. Press the Humidity button(28) again to switch air cooling
off.
ð The Humidity LED(27) goes out.
ð The device continues to run in the previously selected
operating mode.
9EN
Operating manual – air cooler PAE 50
Note
31
33
29
30
34
28
32
36
35
When air cooling mode is activated, the air and
honeycomb filter must not be removed, otherwise the
water from the filter will drip down into the device.
Air freshening
In air freshening mode, the fan speed increases and decreases
alternately to generate a pleasant, natural air stream.
Please proceed as follows to activate air freshening:
1. Press the Mode button(29) until the Air freshening
LED(18) is illuminated. The fan stages are automatically
adjusted.
Ventilation
In ventilation mode, you can select all 4fan speeds manually.
Please proceed as follows to activate ventilation:
1. Press the Mode button(29) until the Ventilation LED(26) is
illuminated.
2. To adjust the fan stage, press the Speed button(33) until
the LED for the desired fan stage(20) is illuminated.
Night mode
In night mode, it is possible to additionally switch on air cooling.
Air freshening cannot be activated.
The timer is automatically set to 8h.
In night mode, the device operates using a preset programme
with different fan speeds to generate an air stream that is
adapted to human sleeping habits.
1. Press the Mode button(29) until the Night mode LED(19)
is illuminated.
Automatic switch-on
ü The device is switched off.
1. Press the Timer button(30) until the desired number of
hours is displayed by the Hours LEDs(25).
ð The timer setting equals the desired number of hours.
ð The device automatically starts in the previously selected
operating modes after the set number of hours has elapsed.
Notes regarding automatic switch-on:
•Manually switching the device on disables the automatic
switch-on function.
•If the power supply is interrupted, the timer and memory
function will be deactivated.
Automatic switch-off
ü The device is switched on.
1. Press the Timer button(30) until the desired number of
hours is displayed by the Hours LEDs(25).
ð The timer setting equals the desired number of hours.
ð The device switches off automatically after the set number
of hours has elapsed.
Notes regarding automatic switch-off:
•Pressing the On/ Off button(34) deactivates the automatic
switch-off function.
Remote control
All settings of the device can also be made using the remote
control included in the scope of delivery.
Setting the timer
The timer has two modes of operation:
•automatic switch-on upon expiry of a preset number of
hours.
•automatic switch-off upon expiry of a preset number of
hours.
The function can be set in all operating modes and also during
stand-by.
The number of hours can be set to 1h, 2h, 4h or 8h.
No.DesignationMeaning
28Humidity buttonSwitching the air cooling mode on
or off
29Mode buttonSelection button for air freshening,
ventilation and night mode
30Timer buttonSwitching the timer function on or
off:
1h, 2h, 4h, 8h
31Ionizer buttonSwitching the ionization mode on
or off
EN10
Operating manual – air cooler PAE 50
No.DesignationMeaning
32Swing buttonSwitching the swing function on
or off
33Speed buttonSetting the fan speed
34On / Off buttonSwitching the device on or off
35Remote control
transmitter/receiver
For infrared transmission to the
device
36Light buttonSwitching the display illumination
on or off
Swing function
The swing function can be switched on in any operating mode if
required.
Behind the horizontal ventilation flaps, there are vertical air flaps
integrated in the device. By means of the swing function, these
air flaps are moved automatically and thus ensure continuous
air circulation.
1. Press the Swing button(32) to switch the swing function
on or off.
Ionization
Ionization can be switched on as needed. The device will then
release ions for additional air purification. The released ions
remove pollen, dust, viruses and bacteria from the room air.
Ionization can be switched on in any operating mode.
1. Press the Ionizer button(31) to switch ionization on or off.
ð When ionization is activated, the Ionizer LED(24) is
illuminated.
Memory function
If you switch the device back on from standby mode, the
settings selected for the operating mode are saved. Any
activated timer or night mode will not be saved in the device.
Adding water
An empty water tank is indicated by the device with a flashing
Humidity LED(27). In this case, the water tank must be refilled.
Observe the following when using the ice packs:
•Put the ice packs into a freezer for at least 4hours before
use.
•The water tank(11) should be filled with water before
inserting the ice packs.
•Only place the ice packs into the designated compartment
in the water tank, otherwise the pump will not function
properly.
Info
When using ice packs at high outside temperatures,
condensation may form at the water tank and drip onto
the floor.
1. Disconnect the device from the mains before refilling water
or putting ice packs into the device.
2. Open the water funnel(3).
Backlight
The LEDs on the operating element can be switched on or off.
1. Press the Light button(36) to switch the backlight on or
off.
Info
If you press a button while the backlight is switched
off, the corresponding LEDs will be illuminated for
approx.45s and then switch off again.
3. Ensure tight fit of the rubber stopper(10), for otherwise
there might be uncontrollable water leakage.
11EN
Operating manual – air cooler PAE 50
4. Fill the water tank(11) with fresh drinking water only.
Optionally, you can add ice cubes made of drinking water
for additional cooling.
ð Observe the minimum and maximum filling level at the
filling level indicator.
The water tank must be filled up to minimum filling level
to enable pump operation.
Auto stop function
If the water tank is empty, the Humidity LED (27) flashes.
In air cooling mode, the fan continues running; in air freshening
mode, the device will stop automatically after a while.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•Switch off the device.
•Hold onto the mains plug while pulling the power cable out
of the mains socket.
•Empty and clean the water tank (see chapter
Maintenance).
•Clean the device according to the Maintenance chapter.
•Store the device according to the Storage chapter.
5. If required, put the ice packs into the water tank(11) for
additional cooling. The ice packs can be inserted in two
ways.
ð Version 1: Insert the ice packs into the device through
the water funnel.
ð Version 2: Remove the honeycomb filter(5) and the air
filter(9) at the rear of the device and insert the ice
packs.
6. Close the flap of the water funnel(3) or reinsert the
honeycomb filter(5) and the air filter(9).
7. Make sure that the device is neither damp nor wet on the
outside. Otherwise wipe it dry.
EN12
Operating manual – air cooler PAE 50
Available accessories
Warning
Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.
Water is leaking:
•Check the device for leaks.
•Check the water tank for tight fit.
The swing function is not working:
•The swing function motor might be defective. Please
contact the customer service.
The device is loud or vibrates:
•Check whether the device is set up in a stable and upright
position.
DesignationArticle number
Evaporation filter7.710.000.837
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•Check the power connection.
•Check the power cable and mains plug for damages.
•Check the on-site fusing.
•Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device works with reduced or no capacity:
•Check the position of the horizontal ventilation flaps. They
should be opened to the maximum.
•Check the air filter for dirt. If necessary, clean or replace
the air filter.
•Check the minimum distance to walls or other objects.
Position the device a little more in the room's centre if
required.
The device is running, but there is no air cooling or pump
operation:
•Check whether air cooling mode is activated. The
operating light should be illuminated.
•Check the filling level of the water tank (see chapter Filling
the water tank). The operating lightmust not be flashing
and there must be no acoustic signal.
•Check whether there are any objects blocking the pump
inlet. Make sure that the pump inlet is not blocked.
•In case the pump does not operate despite a correctly filled
water tank and activated air cooling mode, the pump might
be defective. Please contact the customer service.
The device does not respond to the infrared remote control:
•Check whether the distance between remote control and
device is too large and reduce it if necessary.
•Make sure there are no obstacles, such as furniture or
walls, between the device and the remote control. Ensure
visual contact between device and remote control.
•Check the charging status of the batteries and change
them if required.
•If the batteries have only just been changed, check them
for correct polarity and change them if required.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
Check the air inlets and outlets for
dirt and foreign objects and clean if
necessary
Clean the exterior
Visually check the inside of the
device for dirt
Check the air filter for dirt and
foreign objects and clean if
necessary
Replace the honeycomb filter
Check for damage
Check the attachment screws
Test run
Remarks:
1. Date: ................................
Signature: ............................
5. Date: ................................
Signature: ............................
9. Date: ................................
Signature: ............................
13. Date: ..............................
Signature: ............................
2. Date: ................................
Signature: ............................
6. Date: ................................
Signature: ............................
10. Date: ..............................
Signature: ............................
14. Date: ..............................
Signature: ............................
12345678910111213141516
3. Date: ................................
Signature: ............................
7. Date: ................................
Signature: ............................
11. Date: ..............................
Signature: ............................
15. Date: ..............................
Signature: ............................
4. Date: ................................
Signature: ............................
8. Date: ................................
Signature: ............................
12. Date: ..............................
Signature: ............................
16. Date: ..............................
Signature: ............................
EN14
Operating manual – air cooler PAE 50
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•Switch the device off.
•Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
Visual inspection of the inside of the device for dirt
1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the
device cleaned by a specialist electrical company or by
Trotec.
5. Put the air filter back in.
Cleaning the water tank
The water tank should be cleaned every two weeks.
Note
The water tank cannot be removed.
Do not attempt to remove the water tank for otherwise
the device could be damaged.
Before a longer period of non-use or storage the water tank
should be drained.
1. Carefully transport or wheel the device to a suitable
location for discharging the water (e.g. a drain) or position
a suitable collection container underneath the water outlet.
2. Open the water outlet and drain the water.
Cleaning the housing
Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
3. Remove the air filter and the honeycomb filter from the
device
15EN
Operating manual – air cooler PAE 50
4. Remove the protective filter of the submerged pump from
the device. Pay attention not to damage the protective filter
with your fingers. For this purpose, only touch the plastic
sides of the filter.
5. Clean the protective filter using a slightly damp, soft, lintfree cloth. If the filter is heavily contaminated, clean it with
warm water mixed with a neutral cleaning agent.
6. Clean the water tank using a mild cleaning agent (no dish
detergent!).
7. Remove all calcium deposits in the water tank.
8. Dry the inside of the water tank with a lint-free cloth.
9. Reinsert the protective filter into the device.
10. Fill the water tank with fresh drinking water if you want to
continue operation (see chapter Adding water).
Cleaning the air filter
The air filter has to be cleaned as soon as it is dirty. This is
brought to light e.g. by a reduced capacity (see chapter Errors
and faults).
Warning
Ensure that the air filter is not worn or damaged. The
corners and edges of the air filter must not be
deformed or rounded. Before reinserting the air filter,
make sure that it is undamaged and dry!
1. Remove the air filter from the device.
2. Clean the filter using a slightly damp, soft, lint-free cloth. If
the filter is heavily contaminated, clean it with warm water
mixed with a neutral cleaning agent.
3. Allow the filter to dry completely. Do not insert a wet filter
into the device!
4. Reinsert the air filter into the device.
Filter reset
After an operating time of 200hours, the Filter reset LED(22)
will flash red.
After cleaning, press the Humidity button(28) for 2s to reset the
status.
EN16
Operating manual – air cooler PAE 50
Replacing the honeycomb filter
Note
When set to air cooling mode, the device should not be
operated without the honeycomb filter, otherwise
cooling will not work.
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
The honeycomb filter should be replaced in case of heavy
soiling.
In standard operation, the interval for replacing the honeycomb
filter is approx. 1 year.
Allow the honeycomb filter to dry before removing it from the
device.
1. Remove the air filter and the honeycomb filter from the
device.
4. Reinsert the air filter into the device.
Activities required after maintenance
If you want to continue using the device:
•Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•Store the device according to the Storage chapter.
2. Dispose of the used honeycomb filter according to the
national regulations.
3. Insert the new honeycomb filter into the device.
17EN
Operating manual – air cooler PAE 50
Technical annex
Technical data
ParameterValue
ModelPAE 50
Evaporation capacity2000 ml/h
Air flow rate750 m3/h
Mains supply220-240V~/ 50Hz
Nominal current consumption0.6 A
Power consumption145 W
Sound pressure level (1 m
distance)
Water tank capacity20 l
Weight13 kg
Dimensions (lengthx widthx
height)
Minimum distance to walls and
other objects:
top (A):
rear (B):
sides (C):
front (D):
73 dB(A)
390 x 350 x 880 (mm)
100 cm
100 cm
100 cm
100 cm
Disposal
The icon with the crossed-out waste bin on waste
electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
In the European Union, batteries and accumulators must not be
treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2006/66/EC of the
European Parliament and of the Council of 6September 2006
on batteries and accumulators. Please dispose of batteries and
accumulators according to the relevant legal requirements.
Circuit diagram
EN18
Operating manual – air cooler PAE 50
Trotec GmbH & Co. KG
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
info@trotec.com
www.trotec.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.