Trotec PAC 3200 E A+, PAC 4100 E Operating Manual

Page 1
PAC 3200 E A + / PAC 4100 E
EN
OPERATING MANUAL
LOCAL AIR CONDITIONER
TRT-BA-PAC3200EA+/PAC4100E-TC-003-EN
Page 2

Table of contents

You can download the current version of the operating manual and the EU declaration of conformity via the following link:
Errors and faults..................................................................11
Maintenance ........................................................................12
Technical annex...................................................................15
Disposal ...............................................................................15

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
PAC 3200 E A+
https://hub.trotec.com/?id=42044
PAC 4100 E
https://hub.trotec.com/?id=42045

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Let the device dry out after a wet clean. Do not operate it when wet.
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
Do not sit on the device.
1 EN
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 3
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Observe the technical data when selecting extensions to the power cable. Completely unroll the extension cable. Avoid electrical overload.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk.
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
Ensure that the air inlet and outlet are not obstructed.
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects.
Only transport the device in an upright position with an emptied condensation tray or drain hose.
Discharge the collected condensate before transport and storage. Do not drink it. Health hazard!

Intended use

Only use the device for cooling, ventilating and dehumidifying indoor air whilst adhering to the technical data.

Improper use

Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, such as alterations or structural changes to the device, are forbidden.
Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the operating manual, especially the Safety chapter.
Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.
EN 2
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 4

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Note
Do not operate the device without an inserted air filter! Without an air filter the inside of the device will be heavily contaminated, which could reduce the dehumidification performance and result in damage to the device.

Information about the device

Device description

The device serves the purpose of cooling the room air. It further filters and dehumidifies the air thus creating an agreeable room climate.
The unit cools the room air by withdrawing warmth. The absorbed warmth is emitted to the outside via the exhaust air hose; cooled air is fed to the installation site by means of a fan.
Accumulating condensate drips from the evaporator onto the hot condenser, there it evaporates and then is transported to the outside via the exhaust air hose.
In ventilation mode the device provides the opportunity of air circulation without cooling effect.
In dehumidification mode moisture is withdrawn from the air.
The device operates fully automatically and features a variety of further options. The device can, for instance, be switched on or off automatically with time delay via the timer function.
Operation of the device is possible either via the control panel at the device or via the supplied infrared remote control.
The device was designed for universal and flexible application.
Due to its compact dimensions it can be easily transported and used in all interior spaces.

Behaviour in the event of an emergency

1. Switch the device off.
2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
3 EN
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 5

Device depiction

1
2
3
1
4
5
6
8
1
1
7
9
10
11
8
TIMER
SLEEP
UP DOWN
SPEED
MODE ON/OFF
TIMER
SLEEP
UP
SPEED
MODE
ON/OFF
12
12
No. Designation
9 Water funnel and filling level indication for energy saving
10 Air outlet with ventilation flaps
11 Remote control receiver
12 Transport handle

Transport and storage

Note
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

To make the device easier to transport, it is fitted with wheels.
To make the device easier to transport, it is fitted with a carry handle.
Before transporting the device, observe the following:
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Drain the remaining condensate from the device.
Do not use the power cable to drag the device.
Only wheel the device on a level and smooth surface.
After transporting the device, observe the following:
Set up the device in an upright position after transport.
Leave the device to rest for 12to24hours, so the refrigerant can accumulate within the compressor. Wait 12to24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.

Storage

No. Designation
1 Air inlet with air filter
2 Cable storage compartment with power cable
3 Exhaust air hose connection
4 Hose connector with sealing cap and rubber stopper
5 Exhaust air hose
6 Remote control
7 Wheels
8 Control panel
EN 4
local air conditioner PAC 3200 E A + / PAC 4100 E
Before storing the device, observe the following:
Drain the remaining condensate from the device.
When the device is not being used, observe the following storage conditions:
dry and protected from frost and heat
in an upright position where it is protected from dust and direct sunlight
with a cover to protect it from invasive dust if necessary
Place no further devices or objects on top of the device to prevent it from being damaged.
Remove batteries from the remote control.
Page 6

Assembly and installation

A
B
C
C
D
TIMER
SLEEP
UP
SPEED
MODE ON/OFF
TIMER
SLEEP
UP
SPEED
MODE ON/OFF

Scope of delivery

1x Device
1 x Exhaust air hose
1x Condensation drain hose, length: 1 m, diameter: 18 mm
1x Air filter
3x Insert for sliding window
1x Cover (for sliding window insert)
1x Hose adapter
1 x Remote control
1x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.
Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges.
Make sure that extension cables are completely unrolled.
Keep air inlets and outlets as well as the exhaust air hose connection free.
Make sure that no curtains or other objects interfere with the air flow.
Prior to initial start-up, insert the batteries in the remote control.
Inserting the air filter
Note
Do not operate the device without an inserted air filter! Without an air filter the inside of the device will be heavily contaminated, which could reduce the dehumidification performance and result in damage to the device.

Start-up

When positioning the device, observe the minimum distance from walls or other objects as described in the Technical data chapter.
Connecting the exhaust air hose
1. Screw the end of the exhaust air hose(5) counter­clockwise into the air conditioner's exhaust air hose connection(3).
Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service.
Set the device up in an upright and stable position.
5 EN
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 7
Discharging exhaust air
TIMER
SLEEP
UP DOWN
SPEED
MODE ON/OFF
The exhaust air coming from the device contains waste heat from the room to be cooled. For this reason it is recommended to discharge the exhaust air to the outside.
The end of the exhaust air hose can be fed through the open window. If required, secure the open window with the corresponding means, so that the end of the exhaust air hose cannot shift.
The end of the exhaust air hose can also be hooked into a tilted window.
For this purpose, we recommend using a window seal (optional).
Install the exhaust air hose inclined with the air direction.
How to use the insert
Affix the inserts in the window gap and adjust the length as needed. If required, use the extension pieces.
Connect the hose adapter to the insert.
Close the window until the insert is held securely.
Connect the end of the exhaust air hose to the hose adapter in the insert.
Avoid kinks and bends in the exhaust air hose, as they would lead to an accumulation of emitted humid air causing the device to overheat and shut down.
The dimensions of the exhaust air hose were especially made to fit the device. Do not replace or extend the hose, for it could cause a malfunction.
Opening the ventilation flaps
Prior to switching the device on, open the ventilation flaps at the air outlet(10).
For installing the exhaust air hose please observe the following:
Connecting the power cable
Insert the mains plug into a properly secured mains socket.
EN 6
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 8

Operation

13 14 15 16 17 18 17 19 20
26 25 24 23 22 21
TIMER
SLEEP
UP DOWN
SPEED
MODE ON/OFF
Avoid open doors and windows.
Operating elements
No. Designation Meaning
13 TIMER LED Illuminated when the timer
function is active
14 TIMER button Automatic switch-on timer
function in increments of 1hour (1h to 24h) Automatic switch-off timer function in increments of 1hour (1h to 24h)
15 SPEED button Setting the fan speed
16 Fan speed LED H High fan speed
M Medium fan speed
L Low fan speed
17 Operating
mode LEDs
18 MODE button Selecting the operating mode:
19 ON/OFF button Switching the device on and off
20 Condensation tank
full LED
21 Compressor LED Illuminated when the compressor
Automatic operation
Cooling
Ventilation
Dehumidification
automatic operation cooling ventilation dehumidification
Condensate collection container is full and has to be emptied (see chapter Maintenance)
is running
No. Designation Meaning
22 DOWN button
(decrease value)
23 UP button
Setting the target temperature for cooling between 18°C and 32°C
(increase value)
24 Segment display Display of current room
temperature when in operation Display of target temperature while setting it Display of timer Indication of the error code, see chapter Errors and faults
25 SLEEP button to de-/activate night mode
26 Night mode LED illuminated when night mode is
activated
Switching the device on
1. Allow the device to rest for a time.
2. Once you have completely installed the device as described in the Start-up chapter, you can switch it on.
3. Press the ON/OFF button(19).
ð The device will be switched on in automatic operation. ð The current room temperature is indicated on the
segment display(24).
ð The device runs in automatic operation mode.
4. Select the desired operating mode.
The device switches off automatically when the condensation tank is full. The condensation tank full LED(20) will be illuminated and an acoustic signal will be emitted.
Setting the operating mode
The device has the following operating modes:
automatic operation
cooling
ventilation
dehumidification
Automatic operation
In automatic operation mode the cooling and ventilation process will be regulated depending on the ambient temperature and the preset target temperature of 24°C.
With an ambient temperature of more than 25°C (preset target temperature + 1°C) the device automatically runs in cooling mode until the target temperature of 24°C is reached. The LEDs for automatic operation and cooling(17) light up.
If the ambient temperature is less than or equal to (≤) 25°C, the device will automatically be operated in ventilation mode. The LEDs for automatic operationand ventilation(17) light up.
1. Press the MODE button(18) until the LED for automatic operation(17) lights up.
7 EN
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 9
Cooling
In cooling mode the room will be cooled down to a certain preselected temperature.
Cooling commences when the ambient temperature equals the set temperature + 3°C.
Default settings in cooling mode:
The target temperature is preset to 24°C.
If the ambient temperature is greater than or equal to (≥) 27°C (target temperature + 3 °C), the device runs automatically in cooling mode. The cooling LED(17) is illuminated.
If the ambient temperature is less than or equal to (≤) 25°C (target temperature + 1°C), the device will automatically be in ventilation mode. The ventilation LED(17) is illuminated.
1. Press the MODE button(18) until the LED for cooling(17) lights up.
2. Press the buttons for increasing(23) or reducing(22) the temperature to adjust the desired target temperature.
ð The target temperature flashes for approx. 5s. Then the
current room temperature will be displayed.
Ventilation
Info
Remove the exhaust air hose during ventilation.
In ventilation mode the room air is circulated, it will neither be cooled nor dehumidified.
Possible fan speed settings are:
H = high fan speed
M = medium fan speed
L = low fan speed
1. Press the MODE button(18) until the LED for ventilation(17) lights up.
2. Press the SPEED button(15) to set the desired fan speed.
ð The LED for the selected fan speed(16) will be
illuminated.
Dehumidification
Info
If the device is operated in a very humid environment, the accumulating condensate must be discharged at regular intervals (see chapter Condensate discharge).
If you use the device for an extended period of time or you don't want to empty the tank all the time, you can connect a condensation drain hose to the hose connection.
1. Switch the device off.
2. Hold onto the mains plug while pulling the power cable out of the mains socket.
3. Carefully transport or wheel the device to a suitable location for discharging the condensate (e.g. a drain) or position a suitable collection container under the condensate outlet.
4. Unscrew the sealing cap from the hose connector(4).
5. Remove the rubber stopper from the hose connection.
6. Keep sealing cap and rubber stopper for later use.
7. Connect the condensation drain hose included in the scope of delivery to the hose connector. Check the condensation drain hose for tight fit.
8. Lead the condensation drain hose to a drain or sufficiently dimensioned collection container. To ensure that the condensate can run off, the condensation drain hose must not be kinked, nor should it have to overcome an uphill incline towards the drain.
9. Insert the mains plug into a properly secured mains socket.
10. Switch the device on.
Setting the timer
The timer has two modes of operation:
automatic switch-on upon expiry of a preset number of hours.
automatic switch-off upon expiry of a preset number of hours.
The function can be set in all operating modes and also during stand-by.
The number of hours can be between 1 and 24 and can be adjusted in increments of 1h.
Info
Remove the exhaust air hose during dehumidification, otherwise the performance will be insufficient.
Note
Do not leave the operating device unattended in a freely accessible room with an activated timer.
In dehumidification mode the humidity level in the room is reduced.
The temperature cannot be adjusted and the fan runs at the lowest speed level.
1. Press the MODE button(18) until the LED for dehumidification(17) lights up.
ð Dehumidification mode is selected. ð The compressor LED(21) is illuminated.
EN 8
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 10
Automatic switch-on
TIMER
SLEEP
UP DOWN
SPEED
MODE ON/OFF
ü The device is switched off.
1. Press the TIMER button(14) until the desired number of hours is shown on the segment display(24).
ð The number of hours flashes in the segment
display(24).
2. Wait for approx. 5seconds in order to save the setting.
ð The TIMER LED(13) is illuminated. ð The timer setting equals the desired number of hours. ð The device starts in automatic operation mode after the
set time has passed.
Notes regarding automatic switch-on:
If the device is disconnected from the power supply, all settings for automatic switch-on are deleted.
Manually switching the device on disables the automatic switch-on function.
If you select 0hours, the timer will be off.
Automatic switch-off
ü The device is switched on.
1. Press the TIMER button(13) until the desired number of hours is shown on the segment display.
ð The number of hours flashes in the segment
display(24).
2. Wait for approx. 5seconds in order to save the setting.
ð The segment display changes back to the normal indication. ð The TIMER LED(13) is illuminated. ð The timer setting equals the desired number of hours. ð The device switches off after the set period of time.
Notes regarding automatic switch-off:
Pressing the ON/OFF button(19) deactivates the automatic switch-off function.
Night mode
Night mode can only be activated in cooling mode. Night mode comes with the following settings:
After one hour the preset temperature is increased by 1°C.
After 2hours the preset temperature will again be increased by 1°C. Then the temperature is kept constant.
The fan speed is automatically lowered to the the min. level and cannot be changed manually.
After 12hours of operation in night mode the device switches off automatically.
To deactivate night mode, please proceed as follows:
1. Press the SLEEP button(25).
ð The night mode LED(26) is illuminated. ð The fan speed is automatically adjusted to the lowest
level.
2. In order to switch the night mode off, press the SLEEP button(25) once again.
ð The LED for night mode(26) goes out. ð Fan speed and temperature will return to the level that
was set before night mode was activated.
Energy saving
The device comes with an energy efficiency boosting function. The energy efficiency can be enhanced by filling water into the water funnel(9) of the device.
ü The device is switched on. ü The device has been in operation for at least one hour with
the compressor.
1. Open the water funnel(9).
2. You can fill up to max. 2.5l of water into the tank. In doing so, watch the filling level indication to the left of the water funnel.
3. Close the water funnel.
Note: The condensation tank full LED(20) will light up if you fill too much water into the tank. If so, the condensation tank should be gradually emptied until the LED goes out again (see Emptying the condensation tank in the Maintenance chapter). It is not possible to implement the energy-saving measure with a simultaneously connected condensation drain hose, for the water will immediately be drained from the tank.
9 EN
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 11
Remote control
ON/OFF
MODE
SPEED UP
TIMER
SLEEP
DOWN
27
28
19
23
22
18
25
14
15
All settings of the device can also be made using the remote control included in the scope of delivery.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Empty the condensation tray if necessary.
If necessary, remove the condensation drain hose and any residual fluid from it.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
No. Designation Meaning
14 TIMER button Automatic switch-on timer function in
increments of 1hour (1h to 24h) Automatic switch-off timer function in increments of 1hour (1h to 24h)
15 SPEED button Setting the fan speed in 3 stages:
high, medium and low
18 MODE button Selecting the operating mode:
automatic operation cooling ventilation dehumidification
19 ON/OFF button Switching the device on and off
22 DOWN button
(decrease value)
Setting the target temperature for cooling between 18°C and 32°C
23 UP button
(increase value)
25 SLEEP button De-/activating night mode
27 Transmitter of the
remote control
28 Remote control
display
For infrared transmission to the remote control receiver(11) at the device
Display of current room temperature when in operation Display of target temperature while
EN 10
setting it
: automatic operation
: cooling
: ventilation
: dehumidification
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 12

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Observe the operating temperature according to the Technical data chapter.
Check the filling level of the condensation tank, and empty it if necessary. The condensation tank full LED(20) must not light up.
Wait for 10minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec.
The device works with reduced or no cooling capacity:
Check whether cooling mode is selected.
Check the proper fit of the exhaust air hose. In case of kinks, bends or blockage in the hose, exhaust air cannot be discharged. Clear the way for the exhaust air.
Check the position of the ventilation flaps. They should be opened to the maximum.
Check the air filter(s) for dirt. If necessary, clean or replace the air filter(s).
Check the minimum distance to walls or other objects. Position the device a little more in the room's centre if required.
Check whether any windows and/or doors of the room are open. If so, close them. The window for the exhaust air hose has to remain open nonetheless.
Check the temperature setting at the device. Reduce the set temperature if it is higher than the room temperature.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright position.
Condensate is leaking:
Check the device for leaks.
The compressor does not start:
Check whether the overheating protection of the compressor has tripped. Disconnect the device from the mains and let it cool down for approx. 10minutes before reconnecting it.
Check whether the ambient temperature corresponds to the target temperature +3°C (in cooling mode) or to 25°C (preset target temperature +1°C in automatic operation mode). The compressor will not switch on unless the target temperature is reached.
The compressor may start up with a delay of 3min, as it is provided with an internal protection against direct restart.
The device gets very warm, is loud or loses power:
Check the air inlets and air filters for dirt. Remove external dirt.
From the outside, check the device for dirt (see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company for cooling and air­conditioning or by Trotec.
The device does not respond to the infrared remote control:
Check whether the distance between remote control and device is too large and reduce it if necessary.
Make sure there are no obstacles, such as furniture or walls, between the device and the remote control. Ensure visual contact between device and remote control.
Check the charging status of the batteries and change them if required.
If the batteries have only just been changed, check them for correct polarity and change them if required.
Note
Wait for at least 3 minutes after maintenance and repair work. Only then switch the device back on.
Your device still does not operate correctly after these checks?
Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair.

Error codes

The following error messages can be displayed on the segment display(24):
Error code Cause Remedy
E1 Defective
temperature sensor
E2 Defective coil sensor Disconnect the device
Disconnect the device briefly from the mains. Should the error still be displayed after the restart, please contact the customer service.
briefly from the mains. Should the error still be displayed after the restart, please contact the customer service.
11 EN
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 13

Maintenance

Maintenance intervals

Maintenance and care interval before every
start-up
Check air inlets and outlets for dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and foreign objects and clean or replace if necessary
Replace the air filter
Check for damage
Check the attachment screws
Test run
Empty the condensation tray and drain hose
X X
X X
X

Maintenance and care log

Device type: .............................................
Maintenance and care interval
Check air inlets and outlets for dirt and foreign objects and clean if necessary
Clean the exterior
Visually check the inside of the device for dirt
Check the air filter for dirt and foreign objects and clean or replace if necessary
Replace the air filter
Check for damage
Check the attachment screws
Test run
Remarks:
Empty the condensation tray and drain hose
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
as needed at least every
2 weeks
X X
X X
X X
X
at least every 4 weeks
at least every 6 months
X
Device number: ....................................
at least annually
X
1. Date: ................................
Signature: ............................
5. Date: ................................
Signature: ............................
9. Date: ................................
Signature: ............................
13. Date: ..............................
Signature: ............................
EN 12
2. Date: ................................
Signature: ............................
6. Date: ................................
Signature: ............................
10. Date: ..............................
Signature: ............................
14. Date: ..............................
Signature: ............................
local air conditioner PAC 3200 E A + / PAC 4100 E
3. Date: ................................
Signature: ............................
7. Date: ................................
Signature: ............................
11. Date: ..............................
Signature: ............................
15. Date: ..............................
Signature: ............................
4. Date: ................................
Signature: ............................
8. Date: ................................
Signature: ............................
12. Date: ..............................
Signature: ............................
16. Date: ..............................
Signature: ............................
Page 14

Activities required before starting maintenance

TIMER
SLEEP
UP
SPEED
MODE ON/OFF
TIMER
SLEEP
UP
SPEED
MODE ON/OFF
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning of electrical voltage
Tasks which require the housing to be opened must only be carried out by authorised specialist companies or by Trotec.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air­conditioning or by Trotec.
5. Put the air filter back in.

Cleaning the air filter

The air filters have to be cleaned as soon as they are dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults).
Warning
Ensure that the air filters are neither worn nor damaged. The corners and edges of the air filters must not be deformed or rounded. Before reinserting the air filters, make sure that they are undamaged and dry!
1. Remove the air filters from the device.

Refrigerant circuit

The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air­conditioning or by Trotec.
2. Clean the filters using a slightly damp, soft, lint-free cloth. If the filters are heavily contaminated, clean them with warm water mixed with a neutral cleaning agent.
3. Allow the filters to dry completely. Do not put any wet filters into the device!
4. Reinsert the air filters into the device.
13 EN
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 15

Condensate discharge (manual draining)

TIMER
SLEEP
UP
SPEED
MODE ON/OFF
In cooling and dehumidification mode condensate is formed, which is mostly discharged via the exhaust air.
The remaining condensate is collected in a container within the housing. The condensate ought to be drained regularly.
If too much condensate accumulates, the device switches off and indicates this via the condensation tank full LED(20). An acoustic signal is emitted in addition.
1. Carefully transport or wheel the device to a suitable location for discharging the condensate (e.g. a drain) or position a suitable collection container under the condensate outlet.
2. Remove the rubber stopper from the condensate outlet.

Activities required after maintenance

If you want to continue using the device:
Leave the device to rest for 12to24hours, so the refrigerant can accumulate within the compressor. Wait 12to24hours before switching the device back on! Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
Store the device according to the Storage chapter.
3. Drain the condensate.
4. Reattach the rubber stopper to the condensate outlet. Ensure the tight fit of the rubber stopper, for otherwise there might be uncontrolled water leakage.
ð The condensation tank full LED(20) will go out as soon
as the condensate has been drained.
EN 14
local air conditioner PAC 3200 E A + / PAC 4100 E
Page 16

Technical annex

Technical data

Model PAC 3200 E A+ PAC4100E
Cooling capacity 3.2 kW 4.1 kW
Dehumidification performance 1.16 l/h 1.6 l/h
Operating temperature 18 °C to 35°C 18°C to 35 °C
Temperature setting range 18 °C to 32°C 18°C to 32 °C
Max. air volume flow 500 m3/h 500 m3/h
Mains connection 1/N/PE~ 230V / 50 Hz 1/N/PE~ 230V / 50 Hz
Nominal current 4.6 A 7 A
Power input (cooling operation) 1.03 kW 1.58 kW
Sound pressure level 57 dB(A) 57 dB(A)
Refrigerant R-410A R-410A
Amount of refrigerant 680 g 660 g
GWP factor 2,088 2,088
CO2 equivalent 1.42t 1.38 t
Dimensions (length x width x height) 418 x 415 x 790 mm 418 x 415 x 790 mm
Minimum distance to walls and other objects:
top (A):
rear (B):
sides (C):
front (D):
50 cm 50 cm 50 cm 50 cm
50 cm 50 cm 50 cm 50 cm
Weight 28 kg 28.5 kg
Remote control batteries Type LR03 / AAA – 1.5 V (2pcs.) Type LR03 / AAA – 1.5 V (2pcs.)

Disposal

The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
The device is operated with fluorinated greenhouse gas which can be dangerous for the environment and contribute to global warming when emitted to the atmosphere.
Further information is provided on the nameplate.
Dispose of the refrigerant appropriately and according to the national regulations.
In the European Union, batteries and accumulators must not be treated as domestic waste, but must be disposed of professionally in accordance with Directive 2006/66/EC of the European Parliament and of the Council of 6September 2006 on batteries and accumulators. Please dispose of batteries and accumulators according to the relevant legal requirements.
15 EN