Trotec DH 30 VPR+, DH 60 VPR+ Operating Manual

DH 30 VPR+ / DH 60 VPR+
EN
OPERATING MANUAL
DEHUMIDIFIER / CLIMATE MANAGER
TRT-BA-DH30VPR+-DH60VPR+-TC-002-EN
Notes regarding the operating manual.................................1
Safety .....................................................................................2
You can download the current version of the operating manual and the EU declaration of conformity via the following link:
Information about the device................................................4
Transport, assembly and preparation for start-up .............6
Important information regarding the dehumidification
performance and drying rate ................................................8
Operation .............................................................................10
Errors and faults..................................................................15
Maintenance ........................................................................17
Technical annex...................................................................20
Disposal ...............................................................................22

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
DH 30 VPR+
http://hub.trotec.com/?id=39535
DH 60 VPR+
http://hub.trotec.com/?id=39536
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Notice
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
1 EN
Operating manual – dehumidifier / climate manager DH 30 VPR+ / DH 60 VPR+

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Let the device dry out after a wet clean. Do not operate it when wet.
Do not use the device with wet or damp hands.
Do not expose the device to directly squirting water.
Never insert any objects or limbs into the device.
Do not sit on the device.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Do not cover or transport the device during operation.
Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
The electrical connection must correspond to the specifications in chapter Technical data.
Insert the mains plug into a properly secured mains socket.
Observe the technical data when selecting extensions to the power cable. Completely unroll the extension cable. Avoid electrical overload.
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, his service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk.
Observe the storage and operating conditions (see chapter Technical data).
Ensure that the air inlet and outlet are not obstructed.
Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects.
Only transport the device in an upright position with an emptied condensation tank or drain hose.
Discharge the collected condensate before transport and storage. Do not drink it. Health hazard!

Intended use

Only use the device as a stationary dehumidifier for drying and dehumidifying room air as well as for odour elimination (ionization) whilst adhering to the technical data and safety instructions.
Intended use comprises:
protecting valuables and movables in museums, galleries, libraries or garages against moisture,
odour neutralization in garages, archives, wine cellars, cellar vaults, storage facilities or rooms that are neither inhabited nor used by persons,
drying and dehumidifying:
– production plants, underground rooms – store rooms, archives, laboratories
keeping dry of:
– instruments, devices, files – electrical control centres – moisture-sensitive goods, loads, etc.

Improper use

Do not place the device on wet or flooded ground. Do not use the device outdoors. Do not place any objects, e.g. wet clothing, on the device for
drying. Any unauthorised modifications, such as alterations or structural
changes to the device, are forbidden.
EN 2
Operating manual – dehumidifier / climate manager DH 30 VPR+ / DH 60 VPR+

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the operating manual, especially the Safety chapter.
Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!

Behaviour in the event of an emergency

1. In an emergency, disconnect the device from the mains feed-in: Pull the mains plug.
2. Do not reconnect a defective device to the mains.
Warning A falling device can cause injuries! Always transport
and assemble the device with the help of other persons. Never stand below the device when it is
suspended. Ensure adequate stability of the device's wall fixing.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Warning Ozone formation!
In case of improper use the device generates a minor concentration of ozone when operating at stage 5. In general, ozone may cause or intensify fire, it may be fatal if inhaled and irritating to eyes, respiratory system and skin! Endeavour to prevent the formation of ozone. Hence, never leave the device running at stage5 in continuous operation!
Notice
Do not operate the device without an inserted air filter! Without air filter the inside of the device will be heavily contaminated, this could reduce both the dehumidification performance and odour elimination and result in damage to the device.
3 EN
Operating manual – dehumidifier / climate manager DH 30 VPR+ / DH 60 VPR+

Information about the device

Value Protection Range technology (VPR+)

If properly dimensioned and operated, the dehumidifiers of the VPR+series keep the humidity level steady around the clock and, if needed, neutralize a great number of offensive smells.
The humidity is automatically regulated to the set level that reliably prevents corrosion, condensation and mould formation.
A relative humidity between 45 and 50% provides better protection than any other measure against corrosion and rust. Rust mainly occurs at inaccessible, hardly visible spots.
In addition to the dehumidification and odour elimination, the process air is further freed from dust and/or soot depending on the used filter model.
The integrated pump ensures the discharge of the accumulating condensate even over differences in height.
The fan comes with two stages to adjust the device performance to the contaminations and conditions in the room.

Description of the device

The dehumidifiers of the VPR+ series use the principle of condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet(3), the evaporator and the condenser located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator fins as either condensation or rime. The dehumidified, cooled air is rewarmed at the condenser and blown out at a temperature of approx. 5 °C above room temperature.
The drier air thus conditioned mixes with the air in the room via the air outlet(1). The humidity in the room where the device is positioned is reduced as air constantly circulates through the device. Depending on the air temperature and the relative humidity, the condensed water either drops into the condensation tray continuously or only during the defrost phases.
To set the desired humidity level, a hygrostat with control dial(8) is provided in the device's interior. This control dial can be easily accessed once the filter flap(3) has been removed.
The device can reduce the relative humidity of a room to approx. 30%.
At a room temperature of 15°C, the devices emit 1.6 to 3 times of their power consumption to the room air in form of heat (see chapter Technical data, COP). Because of the heat dissipation, which develops during operation, the room temperature can therefore rise by approx. 1 to 3°C.
A high humidity level in the air (starting at 70%RH) provides the perfect breeding ground for mould. However, the room air must not be too dry either (<40%RH). Materials such as leather or rubber become porous, and wood becomes brittle and fissured.
For the storage of vehicles we recommend a relative humidity between 45 and 50%. For other material-specific humidity values please refer to the respective manufacturer's instructions for the stored goods.
Additionally, the device comes equipped with an ionizer which eliminates odours and bacteria from the room air, if required.
Depending on the model an integrated filter absorbs dust and / or soot in the room air.
The incorporated pump helps to discharge condensate; in doing so, it is possible to overcome a difference in altitude of up to 10m. That way, it is possible to discharge condensate across several storeys.
EN 4
Operating manual – dehumidifier / climate manager DH 30 VPR+ / DH 60 VPR+

Device depiction

1
2
4
6
3
7, 8
5
6
1
2
6
3
7, 85
6
6
4
DH30VPR+
DH60VPR+
No. Designation
1 Air outlet (behind faceplate) 2 Housing 3 Air inlet with filter flap 4 Wall holder 5 Hose connector for condensation drain hose 6 Suspension 7 Ionizer control panel (tamper-proof installation inside the device) 8 Control dial hygrostat (tamper-proof installation inside the device)

Scope of delivery

Dehumidifier
Wall holder
Air filter (combination filter)
Air filter (standard)
Condensation drain hose, ø 5mm (inside), l = 10m
Power cable with CEE 7/7 Schuko plug
Operating manual

Available accessories

Combination filter DH30VPR+ (5pieces): art. no.
7.710.000.926
Standard air filter DH30VPR+: art. no. 7.710.000.925
Combination filter DH60VPR+ (5pieces): art. no.
7.710.000.929
Standard air filter DH60VPR+: art. no. 7.710.000.930
5 EN
Operating manual – dehumidifier / climate manager DH 30 VPR+ / DH 60 VPR+

Transport, assembly and preparation for start-up

C
C
A
B
D
DH 30 VPR+ DH 60 VPR+
Always utilize the help of another person to transport and assemble the DH30VPR+. Always utilize the help of two other persons to transport and assemble the DH60VPR+. Do not try to assemble the device without the help of another person. To lift the device, use a forklift or an elevating truck as appropriate.
Observe the following instructions:
When assembling the device, keep a sufficient distance to heat sources.
When assembling the device, especially in wet areas, secure the device locally with an RCD (Residual Current protective Device) which complies with the relevant regulations.
Make sure that extension cables are completely unrolled.
Insert the mains plug into a properly secured mains socket.
When assembling the device, observe the minimum distance from adjacent walls or other objects as described in the Technical Data chapter.
Assembly
Assemble the device as follows: Select screw and dowel sizes suitable for the weight of the
device (see technical data) and the structure of the wall.
Warning A falling device can cause injuries! Always transport
and assemble the device with the help of other persons. Never stand below the device when it is
suspended. Ensure adequate stability of the device's wall fixing.
1. The table or floor on which you should now unpack the device must be clean.
2. Open the screw connection at the housing.
EN 6
Info
The principle of hanging up the DH60VPR+ is the same as for the DH30VPR+. But the DH60VPR+ comes with a longer suspension rail. The following steps will be illustrated by using the DH30VPR+ as example.
Operating manual – dehumidifier / climate manager DH 30 VPR+ / DH 60 VPR+
3. Remove the housing.
4. Mark the position for the bore holes.
8. Suspend the device from the wall holder by means of the mounting brackets. Utilize the help of one or two other persons as well as suitable lifting gear to do so.
9. Put the housing back on the device.
5. Drill the holes into the wall.
6. Insert suitable dowels into the bore holes.
10. Fasten the housing to the device.

Storage

Drain any possibly remaining condensate. When the device is not being used, observe the following
storage conditions:
in an upright and stable position.
dry and protected from frost and heat.
protected from dust and direct sunlight.
with a cover to protect it from invasive dust, if necessary.
7. Fasten the wall holder in place.
7 EN
Operating manual – dehumidifier / climate manager DH 30 VPR+ / DH 60 VPR+
Loading...
+ 16 hidden pages