Page 1
BP5F
EN
OPERATING MANUAL
FOOD THERMOMETER
TRT-BA-BP5F-TC-003-EN
Page 2

Table of contents

You can download the current version of the operating manual and the EU declaration of conformity via the following link:

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
BP5F
https://hub.trotec.com/?id=41866

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Protect the device from permanent direct sunlight.
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
Do not open the device with a tool.
Observe the storage and operating conditions as given in the Technical data chapter.
1 EN
food thermometer BP5F
Page 3

Intended use

Only use the device for temperature measurements by means of the infrared sensor or temperature probe within the measuring range specified in the technical data.
To use the device for its intended use, only use accessories and spare parts which have been approved by Trotec.

Improper use

This device is not suited for measuring the body temperature in humans or animals. The device must not be pointed at people. Do not use the device in potentially explosive atmospheres, for measurements in liquids or at live parts. Trotec accepts no liability for damages resulting from improper use. In such a case, any warranty claims will be voided. Any unauthorised modifications, alterations or structural changes to the device are forbidden.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when handling food at high temperatures, e.g. frying or grilling.
have read and understood the operating manual, especially the Safety chapter.

Information about the device

Device description

The device BP5F is a thermometer intended for temperature measurements in food, which are carried out by means of an infrared sensor or temperature probe in accordance with the HACCP standard (Hazard Analysis and Critical Control Points).
Beside the digital temperature display, three LEDs show whether the detected temperature is within the HACCP compliant temperature ranges.
According to the HACCP directive, complying with the temperature ranges below 4 °C and above 60 °C is an important way of preventing the development and reproduction of harmful microorganisms. On the other hand, temperatures between 4 °C and 60 °C can promote the development of germs. To quickly show whether or not these temperature limits are complied with, the food thermometer BP5F shows three LEDs beside the digital temperature display which indicate the corresponding temperature range.

Residual risks

Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Caution
Keep a sufficient distance from heat sources.
Note
To prevent damages to the device, do not expose it to extreme temperatures, extreme humidity or moisture.
Note
Do not use abrasive cleaners or solvents to clean the device.
EN 2
food thermometer BP5F
Page 4

Device depiction

3
4
6
5
2
1
8
9
10
7
SCAN HOLD
MAX SET
TIMER SET
BP5F
11 12
13
14
15
18
19
20
16
17
21
22
No. Designation
1 Display
2 SET button
3 Temperature probe lock
4 Temperature probe
5 MEAS button
6 TIMER button
7 Cover of the battery compartment
8 Measurement button
9 Infrared sensor
10 LED
Display
No. Designation
11 Battery indicator
12 Temperature unit indication
13 Measurement using the temperature probe indication
14 Timer function indication
15 Segment display for:
maximum value of the last measurement
minimum value of the last measurement
time for the timer function
16 SET indication – Setting the time for the timer function
17 MAX indication – Display of the maximum value
18 Green LED – Temperature below 4°C (40°F)
19 Red LED – Temperature between 4°C and 60°C (40°F
and 140°F)
20 Green LED – Temperature above 60°C (140°F)
21 SCAN indication – Measurement is on
22 HOLD indication – Freezing the display
3 EN
food thermometer BP5F
Page 5

Technical data

Transport and storage

Parameter Value
Model BP5F
Article number 3,510,003,020
Weight 180 g
Dimensions
185 mm x 50 mm x 67 mm (length x width x height)
Temperature
Measuring range -40 °C to +200 °C
(-40 °F to 392 °F)
Accuracy below -5 °C (23 °F): +1 °C (1.8 °F)
between -5 °C and 65 °C (23 °F and
150 °F): +1 °C (1.8 °F)
above 65 °C (150 °F): +1%
Infrared
Measuring range -40 °C to +280 °C
(-40 °F to 536 °F)
Accuracy below -40 °C to 4 °C (-40 °F to
39.2°F): +2 °C (3.6 °F)
between 4 °C and 65 °C (39.2 °F and
150 °F): +1 °C (1.8 °F)
above 65 °C (150 °F): +1.5 %
Reaction time < 500 ms
Type of protection IP65
Emissivity adjustable between 0.10 and 1.0
Distance to measuring
20:1 spot diameter ratio
Automatic switch-off after approx. 20 seconds
Power supply 9 V battery
Note
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

The manufacturer packed the device to the best of his abilities to protect it against transport damage.

Storage

When the device is not being used, observe the following storage conditions:
dry and protected from frost and heat
protected from dust and direct sunlight
The storage temperature is the same as the range given in the Technical data chapter.
Remove the batteries from the device.
Scope of delivery
1x Device BP5F
1x 9 V battery
1 x Quick guide
EN 4
food thermometer BP5F
Page 6

Operation

Note
Make sure that the surface of the device is dry and the device is switched off.
Inserting the battery
1. Open the battery compartment by unscrewing the two screws with a suitable screwdriver.
2. Remove the battery compartment cover(7).
3. Insert the battery(1 x 9V battery) into the battery compartment with correct polarity.
4. Fit the battery compartment cover back on the device and tighten the screws.
Measuring with infrared
Info
Vapours and smoke can influence the measurement.
Info
Ensure that the surface to be measured is free of dust, dirt, ice or similar substances.
Info
To be able to gain exact measurement results on surfaces which reflect heavily, stick matt masking tape to the surface or apply matt black paint with a very high and known degree of emission.
Info
Note the 20:1 ratio of the distance to the measuring spot diameter. The larger the distance to the object, the larger the measuring spot diameter and hence, the less precise the measured result.
Switching on and selecting the measuring mode
Note:
Note that moving from a cold area to a warm area can lead to condensation forming on the device's circuit board. This physical and unavoidable effect can falsify the measurement. In this case, the display shows either no measured values or they are incorrect. Wait a few minutes until the device has become adjusted to the changed conditions before carrying out a measurement.
Proceed as follows to switch between measurement with infrared and measurement with temperature probe:
1. Press any button to switch on the device.
2. Press the MEAS button(6) to switch between measurement with infrared and measurement with temperature probe.
ð If the symbol for measurement with temperature probe
is displayed on the indication(13), the corresponding measuring mode is selected.
ð If the symbol is not displayed, the infrared measuring
mode is selected.
1. Switch the device on and select the infrared measuring mode.
2. Point the device at the object to be measured and hold down the measurement button(8).
ð The SCAN indication(21) appears on the display. The
device performs a measurement.
ð The currently measured value is indicated.
3. Let go of the measurement button(8) again.
ð The HOLD indication(20) appears on the display. The
device stops measuring.
ð The last value measured is shown.
Measuring with temperature probe
1. Press the temperature probe lock(3) and fold out the temperature probe(4).
2. Insert the temperature probe(4) into the object to be measured by approx. 1 cm.
3. Switch the device on and select the temperature probe measuring mode.
4. Press the MEAS button(5).
ð The currently measured value is indicated.
Note
The temperature probe is not suitable as an ice pick and should never be pricked into frozen objects forcefully to prevent damages to the device.
5 EN
food thermometer BP5F
Page 7
Setting the timer
Li-Ion
The device allows you to set a timer. After the set time has passed, a beep is emitted for 30 seconds.
Please proceed as follows to set the timer:
1. Press the TIMER button(6) to open the timer menu.
2. The timer period is displayed.
3. Press and hold the TIMER button(6) for 2 seconds to switch between seconds, minutes and hours.
ð The currently selected time format flashes.
4. Press and hold the SET button(2) to set the corresponding value.
5. Press the measurement button(8) to start the timer.
ð The timer starts and remains active in the background,
even if you switch to another menu or the device turns off because of non-use.
ð After the set time has passed, a beep is emitted for
30 seconds. Press any button to switch off the beep.
The device switches off after approx. 20 seconds of non-use.
Changing the unit °C / °F indication
The default setting for the temperature unit is °C.
Please proceed as follows to change the temperature unit at the device:
1. Press the SET button(2) to change the unit.
ð The currently selected unit °C or °F will be indicated in
the temperature unit indication(12) of the display(1).

Disposal

The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
In the European Union, batteries and accumulators must not be treated as domestic waste, but must be disposed of professionally in accordance with Directive 2006/66/EC of the European Parliament and of the Council of 6September 2006 on batteries and accumulators. Please dispose of batteries and accumulators according to the relevant legal requirements.

Maintenance and repair

Battery change

A battery change is required when a battery indication lights up on the display(1) or the device can no longer be switched on. See chapter Operation.

Cleaning

Clean the device with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Do not use any sprays, solvents, alcohol-based cleaning agents or abrasive cleaners, but only clean water to moisten the cloth.

Repair

Do not modify the device or install any spare parts. For repairs or device testing, contact the manufacturer.

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.
For repairs or device testing, contact the manufacturer.
EN 6
food thermometer BP5F
Page 8
Page 9
Trotec GmbH & Co. KG
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400 +49 2452 962-200
info@trotec.com www.trotec.com
Loading...