EN Operating manual – Pyrometer BP21 4
Carrying out a measurement
Note:
Note that moving from a cold area to a warm area can lead to
condensation forming on the device's circuit board. This physical
and unavoidable effect can falsify the measurement. In this case,
the display shows either no measured values or they are
incorrect. Wait a few minutes until the device has become
adjusted to the changed conditions before carrying out a
measurement.
• Ensure that the surface to be measured is free of dust, dirt or
similar substances.
• To be able to gain exact measurement results on surfaces
which reflect heavily, stick matt masking tape to the surface
or apply matt black paint with a very high and known degree
of emission.
• Note the 12:1 ratio of the distance to the measuring spot size.
For accurate measurements the measuring object should be
at least twice as large as the measuring spot.
1. Point the device at the object to be measured.
2. Press the Measurement button (6).
– Hold onto the Measurement button (6) if you want to
perform a prolonged measurement.
– The device turns on and carries out a measurement. The
SCAN indication (17) appears on the display.
– The current measured value is indicated.
3. Let go of the Measurement button (6) again.
– The device stops measuring. The HOLD symbol (18)
appears in the display. Depending on the setting of the
device, either the maximum or minimum value (14) of the
last measurement is shown in addition.
The device switches off after approx. 8 seconds without being
used.
Switching the laser pointer on or off
Ex works the laser pointer is switched off.
Danger due to laser radiation!
Please observe that with a switched-on laser the laser
pointer will go on as soon as you press the Measurement
button (6) or activate continuous measurement.
1. Press the Laser button (4).
– The Laser pointer on symbol (19) appears on the display.
– The laser pointer is switched on.
2. Press the Laser button (4) again.
– The Laser pointer on symbol (19) is no longer displayed.
– The laser pointer is switched off.
The device memorizes the selected setting when switching off.
Switching the display illumination on or off
Ex works the display illumination is switched off.
1. Press the Lamp button (2).
– The display illumination will be switched on.
2. Press the Lamp button (2) again.
– The display illumination will be switched off.
The device memorizes the selected setting when switching off.
Further setting options
By use of the Mode key (3) you can access the extended choice
of settings. Alarm thresholds and temperature units can be
selected here, for instance.
1. Press the Mode key (3) several times to reach the desired
setting:
You can adjust the respectively selected setting by use of the
Laser button (4) (up) or the Lamp button (2) (down).
Note:
With activated continuous measurement it is not possible to
switch the background illumination or the laser beam on and off.
Select the corresponding setting before activating continuous
measurement.
Example: Setting the degree of emission:
1. Press the Mode key (3) once.
– Extended setting mode will be started.
– The Degree of emission indication (13) flashes.
– The value can be adjusted upwards using the Laser
button (4).
– The value can be adjusted downwards using the Lamp
button (2).
– The value range is between 1.00 and 0.10.
Number Menu option
1 x Setting the degree of emission
2 x Setting the temperature unit
3 x Activating maximum or minimum value
4 x Activating continuous measurement
5 x Enabling/disabling the upper alarm threshold
6 x Entering the upper alarm threshold
7 x Enabling/disabling the lower alarm threshold
8 x Entering the lower alarm threshold