Trotec BP10 Operating Manual

Page 1
EN Operating manual - Infrared thermometer BP10 B - 1
Notes regarding the operating manual ............ B - 01
Safety............................................................. B - 03
Technical data................................................ B - 05
Description of the device ................................ B - 06
Operation ....................................................... B - 08
Maintenance and repair.................................. B - 13
Disposal ......................................................... B - 14
Symbols
Danger!
Warns of a hazard which can lead to inju­ries.
Risk from laser radiation!
Warns of injury risk from laser radiation.
Caution!
Warns of a hazard which can lead to damage to property.
Table of contents Notes regarding the operating manual
Page 2
B - 2 Operating manual - Infrared thermometer BP10 EN
Legal notice
This release replaces all previous versions. No part of this publication may be reproduced without written per­mission from TROTEC
®
. The same applies for electro­nically processing, duplicating or spreading the publication. Subject to technical changes. All rights reserved. Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer. Product names are registe­red. Changes to construction in the interests of constant improvements to the product, as well as changes to the shape and colour are reserved.
The delivered product may vary from product images. This document was created with all due care. TROTEC
®
accepts no liability whatsoever for possible mistakes or omissions. © TROTEC
®
Page 3
EN Operating manual - Infrared thermometer BP10 B - 3
Intended use
This device is exclusively intended for measuring tem­perature with an infrared sensor in the measuring range specified in the technical data. People who use this de­vice must have read and understood the operating ma­nual, especially the "Safety" chapter.
Improper use
The device must not be used in potentially explosive at­mospheres. It may not be pointed at people. TROTEC
®
accepts no liability for damages resulting from improper use. In such a case, entitlements to a warranty are forfeited.
Safety
Page 4
B - 4 Operating manual - Infrared thermometer BP10 EN
Risk from laser radiation!
• Do not look into the laser beam. Do not point the device at people.
Danger!
• Keep a sufficient distance away from sources of heat!
Caution!
• Do not use abrasive cleaners or solvents to clean the device.
• Do not leave the packaging lying around. Children may use it as a dangerous toy.
• The device is not a toy and does not belong in the hands of children.
Page 5
EN Operating manual - Infrared thermometer BP10 B - 5
Model BP10
Weight 82 g
Dimensions H x W x D 96 x 57 x 25 mm
Measuring range -30 °C to 270 °C / -22 °F to 518 °F
Accuracy ± 2 °C (± 4 °F) or 2.0 % of the measured
value (the higher value applies)
Measuring range resolution 0.1 °C / °F
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Humidity during operation Max. 80 % relative humidity
Laser output < 1 mW (630–670 nm)
Laser class ll
Emissivity Adjustable between 0.10 and 1.0
Technical data
Distance to measuring spot ratio
6:1
Reaction time < 1 second
Power supply two 1.5 V AAA batteries
Switch off After approx. 10 seconds of non-use
Page 6
B - 6 Operating manual - Infrared thermometer BP10 EN
Functional description
The infrared thermometer BP10 uses an infrared sensor to measure surface temperatures without contact. So that you can accurately see where the device is measu­ring, a built in laser pointer can be switched on. The de­vice can show either the highest or lowest value of the measurement. For the maximum or minimum value, a temperature alarm can also be set.
Description of the device
1. IR sensor 2. "Meas" button
3. "Set" button 4. Display
5. "Laser" button 6. Laser pointer
2
1
3
4
5
6
Page 7
EN Operating manual - Infrared thermometer BP10 B - 7
Display 7. Maximum value alarm on
8. Temperature alarm on
9. Emissivity
10. Unit of the temperature
11. Temperature display
12. Battery indicator
13. Change the values up/down
14. Shows the maximum or minimum value
15. Measurement is on
16. Display is frozen
17. Laser pointer on
18. Continuous measurement on
10
9
11
7
8
13
14
15 16 17 18
12
Page 8
B - 8 Operating manual - Infrared thermometer BP10 EN
Temperature measurement
• Ensure that the surface to be measured is free of dust, dirt or similar substances.
• To be able to gain exact measurement results on sur­faces which reflect heavily, stick matt masking tape to the surface or apply matt black paint with a very high and known level of emissivity.
• Note the 6:1 ratio of the distance to the measuring spot size. The larger the distance to the object, the larger the measuring spot size and hence, the less precise the measured result.
Operation
24:412:26:1
600:100300:50150:25
inch
mm
Page 9
EN Operating manual - Infrared thermometer BP10 B - 9
1. Point the device at the object to be measured and hold down the "MEAS" (2) button.
–The device turns on and carries out a measu-
rement. The "SCAN" symbol (15) appears in the display. The current measured value is shown.
2. Release the "MEAS" button (2).
– The device stops measuring. The "HOLD"
symbol (16) appears in the display. Depending on the setting of the device, either the maximum or minimum value of the last measurement is shown.
The device switches off after approx. 10 seconds without being used.
Settings Laser pointer / display backlight
• Press the "Laser" button (5) once to switch on the laser pointer. The "Laser pointer on" symbol (17) appears on the display.
• Press the "Laser" button (5) twice to switch on the display backlight.
• Press the "Laser" button (5) three times to switch off the laser pointer.
• Press the "Laser" button (5) four times to switch off the display backlight.
Page 10
B - 10 Operating manual - Infrared thermometer BP10 EN
Temperature measurement settings
With the "Set" button (3), you can switch between the settings for temperature measurement. The order is the same as in the following description. Confirm the entries with the "MEAS" button (2).
Changing the display - Minimum/Maximum
The "Max" symbol (14) is shown. Press the "Laser" button (5) to change between Min and Max.
Changing the display °C - °F
The "°C" and "°F" symbols (10) flash. Press the "Laser" button (5) to change between the units for the measured values.
Page 11
EN Operating manual - Infrared thermometer BP10 B - 11
Increase emissivity
The "Emissivity" symbol (9) flashes. An arrow (13) is shown. Press the "Laser" button (5) to increase emissivity.
Decrease emissivity
The "Emissivity" symbol (9) flashes. An arrow (13) is shown. Press the "Laser" button (5) to decrease emissivity.
Continuous measurement
The "Continuous measurement on" symbol (18) is shown. The "Off" message appears in the display. Press the "Laser" button (5) to switch on continuous me­asurement. The "On" message appears in the display.
In continuous measurement mode, the device stays running until the "Laser" button (3) is pressed again.
Page 12
B - 12 Operating manual - Infrared thermometer BP10 EN
Increase temperature alarm
The "HI" symbol (7) is shown. An arrow (13) is shown. Press the "Laser" button (5) to increase the highest value.
Decrease temperature alarm
The "HI" symbol (7) is shown. An arrow (13) is shown. Press the "Laser" button (5) to decrease the maximum value.
Temperature alarm on/off
The "Temperature alarm" symbol (8) appears. The "Off" message appears in the display. Press the "Laser" button (5) to switch on the tempera­ture alarm. The "On" message appears in the display. Press the "Laser" button (5) again to switch off the tem­perature alarm. The "Off" message appears in the display.
Page 13
EN Operating manual - Infrared thermometer BP10 B - 13
Battery change
Caution!
Make certain that the surface of the device is dry and the device is switched off.
Maintenance and repair
Page 14
B - 14 Operating manual - Infrared thermometer BP10 EN
Cleaning
Clean the device with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Do not use any sprays, solvents, alcohol-based cleaning agents or abrasive cleaners. Only use clean water to moisten the cloth.
Repair
Do not modify the device or install any spare parts. For repairs or device testing, contact the manufacturer.
In the European Union, electronic equip­ment must not be treated as domestic was­te, but must be disposed of professionally
in accordance with Directive 2002/96/EC of the European Parliament and Council of 27th January 2003 concerning old electrical and electronic equip­ment. After the end of its use, please dispose of this de­vice in a manner appropriate to the relevant legal requirements.
Disposal
Page 15
EN Operating manual - Infrared thermometer BP10 B - 15
in accordance with the EC Low Voltage Directive 2006/95/EC, Annex III, Section B and the EC Directive 2004/108/EC about electromagnetic compatibility. We hereby declare that the infrared thermometer BP10 was designed, developed and produced in compliance with the named EC Directive.
Manufacturer: Trotec GmbH & Co. KG Phone: +49 2452 962-400 Grebbener Straße 7 Fax: +49 2452 962-200 D-52525 Heinsberg E-mail: info@trotec.com
Heinsberg, 5 April 2012
Managing Director: Detlef von der Lieck
Declaration of conformity
Page 16
TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg
Tel.: +49 2452 962-400 • Fax: +49 2452 962-200
www.trotec.com • E-Mail: info@trotec.com
Loading...