Trotec BD5A Operating Manual

Page 1
BD5A
EN
OPERATING MANUAL
CROSS LINE LASER
TRT-BA-BD5A-TC-001-EN
Page 2

Table of contents

You can download the current version of the operating manual and the EU declaration of conformity via the following link:

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning of laser radiation
This symbol indicates dangers to the health of persons due to laser radiation.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Notice
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
BD5A
http://hub.trotec.com/?id=40083

Legal notice

This release replaces all previous versions. No part of this publication may be reproduced without written permission from
TrotecGmbH&Co.KG. The same applies for electronically
processing, duplicating or spreading the publication. Subject to technical changes. All rights reserved. Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer. Product names are registered.
Changes to construction in the interests of constant improvements to the product, as well as changes to the shape and colour are reserved.
The scope of delivery may vary from product images. This document was created with all due care.
TrotecGmbH&Co.KG accepts no liability whatsoever for
possible mistakes or omissions.
The only party responsible for determining valid measured results, drawing conclusions and deriving actions is the user.
TrotecGmbH&Co.KG accepts no claims of warranty for the
correctness of the determined measured values or measured results.
Further, TrotecGmbH&Co.KG accepts no liability whatsoever for possible mistakes or damage which have been caused by utilising the determined measured results.
© TrotecGmbH&Co.KG
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
1 EN
Operating manual – cross line laser BD5A
Page 3

Warranty and liability

The device complies with the fundamental health and safety requirements of the applicable EU regulations and was tested at the factory for perfect functionality multiple times.
If malfunctions occur nonetheless, please contact your dealer or distributor.
When making a warranty claim, supply the device number (see label on the device).
When manufacturer's instructions or legal regulations have not been followed, or after unauthorised changes to the device are made, the manufacturer is not responsible for the resulting damages. Changes to the device or unauthorised replacement of individual parts can drastically impact the electrical safety of this product and will result in the loss of the warranty. Liability does not extend to damages to people or property caused by the device being used other than as described in the instructions in this operating manual. Subject to changes to technical design and model changes as part of constant development and product improvement without prior notice.
No liability is accepted for damages resulting from improper use. In such a case, any warranty claims will be voided also.

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Do not immerse the device in water. Do not allow liquids to penetrate into the device.
The device may only be used in dry surroundings and must not be used in the rain or at a relative humidity exceeding the operating conditions.
Protect the device from permanent direct sunlight.
Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
Do not open the device with a tool.
Avoid looking directly into the laser beam.
Never point the laser beam at people or animals.
Only use the device if sufficient safety precautions were taken at the surveyed location (e.g. when performing measurements along public roads, on building sites etc.). Otherwise do not use the device.
Observe the storage and operating conditions (see chapter Technical data).

Intended use

Only use the device for the projection on non-reflective surfaces as an aid to determine and check horizontal, vertical and/ or parallel lines. Observe and comply with the technical data.
To use the device for its intended use, only use accessories and spare parts which have been approved by Trotec.

Improper use

Do not use the device in potentially explosive atmospheres or in liquids. Never point it at people or animals. Trotec accepts no liability for damages resulting from improper use. In such a case, any warranty claims will be voided.
Any unauthorised modifications, alterations or structural changes to the device are forbidden.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with laser measuring devices.
have read and understood the operating manual, especially the Safety chapter.
EN 2
Operating manual – cross line laser BD5A
Page 4

Residual risks

1
2
4
3
5
Warning of laser radiation Laser class2, P max.: > 1mW, λ: 650nm,
EN 60825-1:2014
Do not look directly into the laser beam or the opening from which it emerges. Never point the laser beam at people, animals or reflective surfaces. Even brief eye contact can lead to eye damage. Examining the laser output aperture by use of optical instruments (e.g. magnifying glass, magnifiers and the like) entails the risk of eye damage. When working with a laser of class2, observe the national regulations on wearing eye protection.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.
Warning
The device is not a toy and does not belong in the hands of children.

Information about the device

Device description

The cross line laserBD5A projects laser lines on surfaces, e.g. to drill holes in a straight line – similar to using a spirit level.
The device comes with the following features:
Projects light-intense laser lines up to a distance of 10m
Self-levelling up to an inclination of 4°
Laser projection either as cross lines or as individual horizontal or vertical line
Battery-operated
Integrated ¼ inch tripod connection

Device depiction

Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Caution
Keep a sufficient distance from heat sources.
Notice
To prevent damages to the device, do not expose it to extreme temperatures, extreme humidity or moisture.
Notice
Do not use abrasive cleaners or solvents to clean the device.
No. Designation
1 ON/ OFF/ operating mode button
2 ON/ OFF/ lock switch
3 1/4inch tripod connection (bottom)
4 Battery compartment with cover
5 Laser outlet opening
3 EN
Operating manual – cross line laser BD5A
Page 5
Multifunctional mount
6
7
8
9
12
11
10
No. Designation
6 Screw (for tripod connection)
7 Wing nut (for ball joints)
8 Locking screw (for retainer with jaws)
9 Lever (for suction cup)
10 Suction cup
11 Retainer with jaws
12 Ball joint

Transport and storage

Notice
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

For transporting the device use a suitable bag to protect it from external influences.

Storage

When the device is not being used, observe the following storage conditions:
Dry and protected from frost and heat
Protected from dust and direct sunlight
With a cover to protect it from invasive dust if necessary
The storage temperature is the same as the range given in the Technical data chapter
Remove the batteries from the device

Technical data

Parameter Value
Model: BD5A
Weight: 275 g
Dimensions (length x width x height): 83 x 60 x 72 mm
Accuracy – laser: at 0° to 4°: ±0.8mm/m
at ≥4°: ±1mm/m
Range: 10 m
Operating temperature: -20 °C to 50 °C
Storage temperature: -20 °C to 50 °C
Laser output: < 1 mW (650 nm)
Laser class: 2
Power supply: 2x AlkalineAA, 1.5V batteries
Scope of delivery
1x Cross line laser BD5A
2x AlkalineAA, 1.5V batteries
1x Multifunctional mount
1 x Quick guide
EN 4
Operating manual – cross line laser BD5A
Page 6

Operation

4
Inserting the batteries
Insert the supplied batteries into the device before first use.
Notice
Make sure that the surface of the device is dry and the device is switched off.
1. Open the cover(4) of the battery compartment.
2. If applicable, remove the old batteries.
3. Insert the new batteries in the battery compartment with correct polarity.
4. Then close the cover of the battery compartment(4) again.
Switching the device on
Warning of laser radiation Laser class2, P max.: > 1mW, λ: 650nm,
EN 60825-1:2014
Do not look directly into the laser beam or the opening from which it emerges. Never point the laser beam at people, animals or reflective surfaces. Even brief eye contact can lead to eye damage. Examining the laser output aperture by use of optical instruments (e.g. magnifying glass, magnifiers and the like) entails the risk of eye damage. When working with a laser of class2, observe the national regulations on wearing eye protection.
The device has 2different modes of operation. On the one hand, you can use the device with the automatic self-levelling function, on the other, it is possible to set the laser to a fix position.
5 EN
Operating manual – cross line laser BD5A
Page 7
Self-levelling function of the laser
2
2x
1x
1
1. Slide the on/off switch(2) to to switch the device on.
4. Slide the on/off switch(2) back to to switch the device off.
ð Please note that the lasers' current position is fixed.
Fixed position of the laser
Before using the lasers with a fixed position, perform a self­levelling operation to make sure the lasers are properly aligned.
1. Check whether the lock switch(2) is set to .
2. Press the on/off button(1) to switch both lasers on.
3. Press the on/off button(1) a second time to only activate the horizontal laser.
4. Press the on/off button(1) a third time to only activate the vertical laser.
5. Press the on/off button(1) a fourth time to switch the device off.
Info
You can activate the self-levelling function at any time
ð Both the vertical and the horizontal laser switch on. ð The operating mode button(1) is illuminated in green. ð If the operating mode button(1) is illuminated in red
and the laser flashes, the permissible inclination range of 4° is exceeded. Position the device horizontally.
2. By means of the operating mode button(1) you can select whether both lasers are to be activated or only either the horizontal or the vertical laser.
3. When positioning the device as desired, the self-levelling function of the lasers commences automatically.
ð When exceeding the permissible inclination range of 4°,
the lasers begin to flash and the operating mode button(1) will be illuminated in red. If so, the self­levelling will not function properly. Position the device horizontally.
(by setting the on/off switch(2) to ). Please note that in this case the device can only be switched off via the on/off switch(2).
Using the multifunctional mount
Proceed as follows to use the multifunctional mount with the device:
1. Screw the mount into the tripod connection at the device.
By means of the suction cup you can affix the mount to smooth surfaces such as tiles or glass.
Alternatively, the clamping jaws can be used to fasten it to a shelf or the edge of a table.
EN 6
Operating manual – cross line laser BD5A
Page 8
Swivelling the device
1. Loosen the wing nut(7).
2. Swivel the device on the ball joints to move it into the desired position.
3. Retighten the wing nut(7).
Application example for the universal clamp
1. Loosen the screw(8) and push the clamping jaws(11) apart until they fit onto the carrier (here: shelf).
2. Tighten the screw(8) until the jaws(11) of the universal clamp are firmly attached to the carrier and the mount can no longer be moved to and fro.
3. To unfasten the clamping jaws(11), loosen the screw(8) until the retainer can be removed from the carrier without difficulty.
7 EN
Operating manual – cross line laser BD5A
Page 9
Application example for the suction cup
1. Make sure that the surface is smooth and clean.
2. Disengage the lever(9) at the suction cup(10).
3. Press the suction cup(10) against the surface (here: tiles).
4. Engage the lever(9) until it locks in place.
6. In order to remove the suction cup(10) again, release the lever(9), then pull at the lug of the suction cup.
5. Check the suction cup(10) for tight fit.
EN 8
Operating manual – cross line laser BD5A
Page 10

Maintenance and repair

Battery change

A battery change is required when the device can no longer be switched on (see chapter Inserting the battery).

Cleaning

Clean the device with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Do not use any sprays, solvents, alcohol-based cleaning agents or abrasive cleaners, but only clean water to moisten the cloth.

Repair

Do not modify the device or install any spare parts. For repairs or device testing, contact the manufacturer.

Disposal

The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.
You are responsible for deleting any personal data stored on the waste equipment to be disposed of.
In the European Union, batteries and accumulators must not be treated as domestic waste, but must be disposed of professionally in accordance with Directive 2006/66/EC of the European Parliament and of the Council of 6September 2006 on batteries and accumulators. Please dispose of batteries and accumulators according to the relevant legal requirements.
9 EN
Operating manual – cross line laser BD5A
Page 11
Page 12
Trotec GmbH & Co. KG
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400 +49 2452 962-200
info@trotec.com www.trotec.com
Loading...