Trotec B 1 E, B6E, B 5 E Operating Manual

B 1 E
EN
OPERATING MANUAL
HUMIDIFIER
TRT-BA-B1E-TC-002-EN

Table of contents

You can download the current version of the operating manual and the EU declaration of conformity via the following link:

Notes regarding the operating manual

Symbols

Warning of electrical voltage
This symbol indicates dangers to the life and health of persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.
Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.
Notice
This signal word indicates important information (e.g. material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the operating manual must be observed.
B 1 E
https://hub.trotec.com/?id=41494

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use!
Warning Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not use the device in potentially explosive rooms.
Do not use the device in aggressive atmosphere.
Set the device up in an upright and stable position.
Fill the device with fresh drinking water only.
Never insert any objects or limbs into the device.
Do not cover or transport the device during operation.
This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation.
Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!
Insert the mains plug into a properly secured mains socket.
Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload.
1 EN
Operating manual – humidifier B 1 E
Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.
Switch the device off and disconnect the power cable from the mains socket when the device is not in use.
Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk.
When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter.
Ensure that the air inlet and outlet are not obstructed.
Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects.
Do not use the device when the water tank is empty.
Before filling the water tank, switch the device off and disconnect the power cable from the mains socket. Hold onto the mains plug while doing so.

Residual risks

Warning of electrical voltage
Work on the electrical components must only be carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket.
Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the hands of children.
Warning
Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy.

Intended use

Only use the device as a mobile humidifier for the humidification and filtration of room air, while adhering to and following the technical data.
Intended use comprises humidifying the room air in:
living spaces
warehouses and archives
libraries
call centres and computer rooms

Improper use

The device is not intended for industrial use.
Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Any unauthorised modifications, alterations or structural changes to the device are forbidden.
Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void.
Caution
If the device is knocked over, water will leak from the lower part. Disconnect the device from the mains to prevent damage to the device caused by dry running.
Notice
Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

Behaviour in the event of an emergency

1. Switch the device off.
2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
3. Do not reconnect a defective device to the mains.

Personnel qualifications

People who use this device must:
be aware of the dangers that occur when working with electric devices in damp areas.
have read and understood the operating manual, especially the Safety chapter.
EN 2
Operating manual – humidifier B 1 E

Information about the device

1
2
9a
3
10
9b
4
5
6
8
7

Description of the device

The device functions as a humidifier and aroma diffuser.
The ultrasound technology ensures a pleasant room climate and air quality improvement.
The device is equipped with an integrated scented oil tank and diffuser for optional room air aromatization.
The capacity of the water tank allows for a runtime of up to 15hours.
When the device is in operation, the water tank can be additionally illuminated by blue LEDs located in the lower part of the device.
The device switches off automatically when the water tank is empty.

Device depiction

No. Designation
1 Top with water tank
2 Bottom section
3 Carbon filter
4 Filling level indication
5 Scented oil tank with sponge
6 Filter cartridge with water softener
7 SecoSan® Stick 10 (optional accessory)
8 Brush
9a On/off switch/ rotary switch nebulizer intensity
9b LED illumination:
red = standby (connected to the mains) white = device is switchedon/ inoperation flashes red = water tank is empty or not installed correctly
10 Mist nozzle
3 EN
Operating manual – humidifier B 1 E

Transport and storage

Assembly and installation

Notice
If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device.

Transport

Before transporting the device, observe the following:
Switch the device off.
Hold onto the mains plug while pulling the power cable out of the mains socket.
Check whether the upper part is correctly positioned on the lower part.
Lift the device at the lower part.
Do not use the power cable to drag the device.
After transporting the device, observe the following:
Set up the device in an upright position after transport.

Storage

Before storing the device, observe the following:
Empty the water tank.
Empty the lower part.
Use a cloth to wipe all parts of the device dry.
Clean the device according to the Maintenance chapter.
When the device is not being used, observe the following storage conditions:
dry and protected from frost and heat
in an upright position where it is protected from dust and direct sunlight
with a cover to protect it from invasive dust if necessary

Scope of delivery

1x Device
1x Water softener
1x Brush
1x Manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.

Start-up

Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service.
Set the device up in an upright and stable position.
Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges.
Make sure that extension cables are unrolled completely.
Make sure that there are no moisture-sensitive objects located in the immediate vicinity of the mist nozzle, since water may condense near the mist nozzle.
Filling the water tank
The water tank should be filled before first use or when the LED at the rotary switch(9b) flashes red.
Notice
Fill the device with fresh drinking water only. The water temperature must not exceed 40°C. Scented oil or other additives can damage the plastics and the nebulizer membrane.
Info
If possible, change the water on a daily basis to prevent bacterial growth.
EN 4
Operating manual – humidifier B 1 E
Loading...
+ 9 hidden pages