Declaration of conformity ...................................................12
Notes regarding the operating manual
Symbols
Hazardous electric current!
Warns about hazards from electric current which can
lead to injuries or even death.
Danger!
Warns of a hazard which can lead to personal injury.
Caution!
Warns of a hazard which can lead to property damage.
The current version of the operating manual can be found at:
Legal notice
This release replaces all previous versions. No part of this
publication may be reproduced without written permission from
Trotec. The same applies for electronically processing,
duplicating or spreading the publication. Subject to technical
changes. All rights reserved. Trademarks are used without
guarantee that they may be used freely and primarily following
the spelling of the manufacturer. Product names are registered.
Changes to construction in the interests of constant
improvements to the product, as well as changes to the shape
and colour are reserved.
The scope of delivery may vary from product images. This
document was created with all due care. Trotec accepts no
liability whatsoever for possible mistakes or omissions.
The device complies with the fundamental health and safety
requirements of the applicable EU regulations and was tested at
the factory for perfect functionality multiple times.
However, if faults in the functionality occur and cannot be
remedied with the measures in the chapter Errors and faults,
please get in touch with your dealer or distributor.
When manufacturer's instructions or legal regulations have not
been followed, or after unauthorised changes to the device are
made, the manufacturer is not responsible for the resulting
damages. Changes to the device or unauthorised replacement
of individual parts can drastically impact the electrical safety of
this product and leads to the forfeit of the warranty. Liability
does not extend to damages to people or property caused by the
device being used other than as described in the instructions in
this operating manual. Subject to changes to technical design
and model changes as part of constant development and
product improvement without prior notice.
No liability is accepted for damages resulting from improper
use. In such a case, any warranty claims be voided also.
AW 20 S
http://download.trotec.com/?sku=1160000020&id=1
1EN
Operating manual – air washer AW 20 S
Page 3
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
•Do not use the device in potentially explosive rooms.
•Do not use the device in aggressive atmosphere.
•Fill the device with fresh drinking water only.
•Set the device up in an upright and stable position.
•Ensure that the air inlet and outlet are not obstructed.
•Ensure that the side of the device where the air inlet is
found is kept free of dirt and loose objects.
•Never reach or put objects into the device.
•Do not cover or transport the device during operation.
•This appliance is not a toy! Do not leave the device running
unattended with children nearby.
•Ensure that all electric cables outside of the device are
protected from damage (e.g. from animals). Never use the
device if the cable or power connection is damaged!
•Only use extensions to the connecting cable which are
appropriate to the device power consumption, the length of
its cable and its use. Completely unroll extension cables.
Avoid electrical overload.
•Unplug the device from the mains before starting with
maintenance, service or repair work.
Residual risks
Hazardous electric current!
Work on the electrical components must only be
carried out by an authorised specialist company!
Hazardous electric current!
Before any work on the device, remove the mains plug
from the mains socket!
Danger!
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Danger!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Behaviour in the event of an emergency
1. In an emergency, disconnect the device from the mains
feed-in: Switch the device off and disconnect it from the
mains.
2. Do not reconnect a defective device to the mains.
Intended use
Use the device AW 20 S for humidifying and cleaning indoor air,
while adhering to and following the technical data. The device is
suited for humidifying the room air in order to create an
agreeable room climate.
Improper use
The device AW 20 S is not suited for the distribution of liquids
other than fresh drinking water. It is not suited for removing
heavy contaminations from the air.
Personnel qualifications
People who use this device must:
•have read and understood the operating manual, especially
the Safety chapter.
EN2
Operating manual – air washer AW 20 S
Page 4
Information about the device
1
2
3
4
5
10
9
8
6
11
12
7
Device description
•3-in-1 combination device for air purification,
humidification and odour elimination
•Suitable for rooms sized up to 55 m² / 138m³
•Humidification performance max. 750 ml/h
•Air flow rate max. 228 m³/h
•Display of relative humidity
•(Changeable) prefilter for coarse dirt such as animal hair,
fluff and dust
•HEPA filter selectable
•HEPA filter reduces the growth of bacteria and mould
•Electrostatic charging and odours are reduced
•No limescale or wet spots
•Sensor-controlled automatic operation:
– An intelligent sensor measures the air quality and
humidity level for automatic control.
•3-stage light signal indicates the air quality in the room
•9 operating modes
•3 fan stages
•Noiseless night operation in whisper mode
•Plasma generator selectable
•Water tank approx. 9litres
•Water level indicator
•Warning signal and automatic switch-off when water tank
is empty
•Quiet operation < 55dB
Device depiction
No.Designation
1Upper part
2Control panel
3Water level indicator
4Cleaning brush
5SecoSan® Stick 10 (optional accessory)
6Lower part
7Disk
8HEPA filter
9Pre-filter
10Power cable
11Air inlet with pre-filter flap
12Air outlet
3EN
Operating manual – air washer AW 20 S
Page 5
Transport and storage
Assembly and installation
Transport
Before transporting the device, proceed as follows:
•Switch off the device at the mains switch.
•Remove the mains plug from the mains socket.
•Prior to every transport check whether the upper and lower
part of the device are firmly interconnected.
•Lift the device at the foot.
Storage
Empty and clean the water tank prior to storage (see chapter
Maintenance).
When the device is not being used, observe the following
storage conditions:
•Dry.
•Protected from dust and direct sunlight.
•With a cover to protect it from invasive dust, if necessary.
Assembly
•1 x Air washer AW 20 S
•1 x Easy Kit cleaning brush
In addition to the scope of delivery, a SecoSan®Stick 10 is
optionally also available.
Unpacking the device
1. Open the cardboard box and take the device out.
2. Remove the packaging from the device.
3. Open the device by lifting the upper part and putting it
aside.
4. Remove the packaging from the disk.
5. Lift the disk out of the water tank.
6. Remove further packaging.
7. Refit the disk into the device.
8. Leave the device open during the following activities for
start-up.
Inserting the SecoSan® Stick (optional)
ü The device is opened.
1. Insert the SecoSan® Stick into the lower part of the water
tank.
2. Check whether the distance between the SecoSan® Stick
and the disk is sufficient. The disk must be able to move
freely.
Installing the device
Keep a sufficient distance to walls and other objects when
choosing the device's site of use. The air inlet and outlet must
not be obstructed or covered, e.g. by curtains.
Filling the water tank
1. Fill the water tank with fresh drinking water.
ð The filling level should not exceed the water level line in
the water tank.
2. Place the upper part onto the water tank.
ð The display on the upper part and the logo on the lower
part should point in the same direction.
3. Check whether the upper and lower part are properly
interconnected as otherwise the device cannot be switched
on.
4. Plug the mains plug into a sufficiently fused mains socket.
EN4
Operating manual – air washer AW 20 S
Page 6
Operation
SCS
141516171819
20
13
2122232527282930
2426
Operating elements
Setting the operating mode
Operating mode DescriptionDisplay
HumidificationThe room air is humidified continuously.
No.Designation
13Power button
14Air purity indication
blue light: high air purity
yellow light: medium air purity
red light: low air purity
15SecoSan® Stick indication
16HEPA filter indication
The LED is illuminated if the HEPA filter must be replaced.
17Water tank indication
18Operating mode humidification indication
19Operating mode selection button
20Fan stage selection button
21Operating mode humidification with HEPA filter indication
22Operating mode air purification indication
23Night mode indication
24Fan min indication
25Humidity level indication
airwasher zone = comfort zone between 40 % and 60 %.
The indicator shows the current room humidity level up to 60 %
even if the device switches off at 50 %.
26Fan med indication
27Fan max indication
28Automatic/continuous operation indication
29Plasma generator indication
30Plasma generator button
Humidification
with HEPA filter
Air purificationThe room air is cleaned.
The room air is humidified continuously.
Additionally the air is cleaned by the HEPA
filter.
Setting the fan stage
The following table shows an overview of the fan stages:
Operating
mode
AutoFan speed control depending on room
Night modeThe device runs in night mode. The LED
Fan maxThe fan runs at the highest speed, regardless
Fan medThe fan runs at medium speed, regardless of
Fan minThe fan runs at the lowest speed, regardless
DescriptionDisplay
humidity.
When reaching a humidity level of 50%, the
device stops. It continues to operate as soon
as the measured humidity level falls below
50%.
illumination of the control panel is dimmed.
The fan runs at the lowest speed.
When reaching a humidity level of 50%, the
device stops. It continues to operate as soon
as the measured humidity level falls below
50%.
of the room humidity.
the room humidity.
of the room humidity.
Switching the device on
ü The water tank is filled with fresh drinking water.
ü The power cable is connected to a sufficiently fused mains
1. Press the selection buttonfor the fan stage (20) until the
desired fan stage is set.
ð The corresponding display is illuminated.
socket.
1. Press the power button(13).
ð The device switches on.
5EN
Operating manual – air washer AW 20 S
Page 7
Switching the plasma generator on or off
The plasma generator can be switched on or off as needed.
1. Press the button for the plasma generator (30) to switch the
plasma generator on or off.
ð If the plasma generator is switched on, the plasma
generator display (29) is illuminated.
ð If the plasma generator is switched off, the plasma
generator display (29) goes out.
Refilling water
If the water tank indication (17) is illuminated, you have to refill
water.
Note:
After approx. one week of operation, the water tank should be
cleaned before refilling with fresh drinking water. Further
information on cleaning the water tank can be found in the
chapter Maintenance.
1. Press the power button(13).
ð The device switches off.
2. Remove the mains plug from the mains socket.
3. Remove the upper part from the water tank.
4. Fill the water tank with fresh drinking water.
ð The filling level should be below the filling level line in
the water tank.
5. Check whether the SecoSan® Stick is correctly positioned
inside the water tank.
6. Place the upper part onto the water tank.
ð The display on the upper part and the logo on the lower
part should point in the same direction.
7. Check whether the upper and lower part are properly
interconnected as otherwise the device cannot be switched
on.
8. Plug the mains plug into a sufficiently fused mains socket.
9. Press the power button(13).
ð The device switches back on.
Maintenance
Activities required before starting maintenance
•Do not touch the mains plug with wet or damp hands.
•Before any work, remove the mains plug!
Cleaning the housing
Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Do not use abrasive
cleaners.
Cleaning the water tank
Clean the water tank at least once a week and prior to every
start-up or shutdown.
ü The device is switched off and disconnected from the
mains.
ü The upper part of the device has already been removed
from the device.
1. Take the disk out of the water tank.
2. Take the SecoSan®Stick out of the water tank.
3. Discharge the residual water into a drain.
4. Clean the inside of the water tank with a mild detergent.
5. Rinse the water tank and the SecoSan®Stick with clear
water thoroughly.
6. Dry the inside of the tank with a lint-free cloth.
7. Insert the SecoSan® Stick into one corner of the water tank.
Make sure not to block the rotating disk.
8. Refit the disk. Check the disk for complete movability. If
necessary, reposition the SecoSan®Stick so that the disk
can turn freely.
9. Fill the water tank with water.
10. Put the upper part back on the device.
Shutdown
•Switch off the device.
•Remove the mains plug from the mains socket.
•Empty and clean the water tank.
•Remove the SecoSan® Stick.
•Clean the upper louvre.
•Store the device according to the chapter Storage.
EN6
Operating manual – air washer AW 20 S
Page 8
Exchanging the SecoSan® Stick (optional)
The SecoSan® Stick should be exchanged approx. every 6
months. The LED display for the SecoSan® Stick lights up when
an exchange is required.
ü The device is switched off and disconnected from the
mains.
ü The upper part of the device has already been removed
from the device.
1. Remove the disk.
2. Remove the SecoSan® Stick and dispose of it properly.
3. If necessary, empty the water tank.
4. Insert the new SecoSan® Stick into one corner of the water
tank. Make sure not to block the rotating disk.
5. Refit the disk. Check the disk for complete movability. If
necessary, reposition the SecoSan®Stick so that the disk
can turn freely.
6. Fill the water tank with fresh drinking water.
7. Put the upper part back on the device.
After switching the device back on, you have to reset the LED
display for the SecoSan® Stick:
The reset function is a combination of the power button (13) and
plasma button (30). Press both buttons simultaneously for
approx. 3 seconds to switch off the display.
Cleaning the disk
ü The device is switched off and disconnected from the
mains.
ü The upper part of the device has already been removed
from the device.
1. In case of slight soiling, insert the Easy Kit between two of
the disks and move it back and forth.
2. In case of heavy soiling, you can disassemble the disk into
its individual components and clean them thoroughly:
Disassembling the disk
1. Take the disk out of the water tank.
2. Open the lateral screwing with the Easy Kit or with a coin by
turning the cap counter-clockwise.
3. Remove the cap.
4. You can take the disks off the shaft and clean them
individually.
5. After cleaning, slide the disks back on the shaft.
6. Put the cap back on the shaft and fasten the cap by turning
clockwise.
7. Reinsert the disk into the device. Check the disk for
complete movability. If necessary, reposition the
SecoSan®Stick so that the disk can turn freely.
8. Put the upper part back on the device.
7EN
Operating manual – air washer AW 20 S
Page 9
Cleaning the pre-filters
Clean the pre-filters regularly, at the latest when heavy soiling is
visible.
Proceed as follows to clean the pre-filters:
ü The device is switched off and disconnected from the
mains.
1. Slightly press onto the air inlet louvre on both sides of the
device.
ð The louvres open.
2. Fold out the louvres up to the lock position at 45°.
6. Clean the louvres under fresh water with a soft cloth.
7. Dry the pre-filters and the louvres before refitting them into
the device.
8. Reinsert the louvres into the guides and fold up the louvres
until they lock in place at approx.45°.
9. Refit the pre-filters into the guide rail in the louvre.
10. Close the louvres with a snap.
3. Remove the two pre-filters.
4. Clean the pre-filters under fresh water with a soft cloth.
5. Remove the two louvres by carefully pressing them down.
EN8
Operating manual – air washer AW 20 S
Page 10
Exchanging the HEPA filters
The HEPA filters should be exchanged in case of heavy soiling.
The HEPA filter indication (16) is illuminated if the HEPA filters
must be replaced.
When operated in standard air washer mode, the HEPA filters
should be replaced approx. every 2 years; in air purification
mode, the period is approx. 1 year.
Proceed as follows to exchange the HEPA filters:
ü The device is switched off and disconnected from the
mains.
1. Remove the upper part from the water tank and place it
onto the floor.
Cleaning the dust sensor
Clean the dust sensor approx. every 6 months.
In very dusty surroundings the dust sensor should be cleaned
every 3 months.
Use customary cotton buds for cleaning. You can slightly
dampen the cotton buds with water. If you are using damp
cotton buds, always wipe dry with a dry cotton bud.
ü The device is switched off and disconnected from the
mains.
1. Remove the cover from the dust sensor at the rear of the
device.
2. Turn the upper part around and position it upside down.
3. Carefully remove the HEPA filters from the guide rail by
pulling at the lug.
4. Dispose of the used HEPA filters according to the national
regulations.
5. Insert the new HEPA filters into the device.
ð The lugs should point up again.
ð The HEPA filters should be firmly seated in the guide
rails.
6. Put the upper part back on the device.
7. After switching the device back on, simultaneously press
the operating mode button (19) and the fan stage button
(20) for approx. 3s.
ð The HEPA filter indication (16) is no longer illuminated.
2. Carefully wipe over the dust sensor with a cotton bud.
3. Reattach the coverto the dust sensor.
Technical annex
Technical data
ParameterValue
Suitable for rooms sized up to55 m² / 138 m³
Humidification performance max.750 ml/h
Display of relative humidity20 % to 60 %
Amount of air90-168-228 [m³/h]
Mains connection1/N/PE ~ 220V / 50 - 60 Hz
Power input max.24 W
Sound pressure level47 dB
Water tank9 l
Dimensions (packaging excluded,
length x width x height)
Weight (packing excluded)10 kg
Water filterSecoSan® Stick 10
410 x 325 x 420 [mm]
9EN
Operating manual – air washer AW 20 S
Page 11
Wiring diagram
BLDC
DM
MSW
Supply Power
230V~
321
RED
STEP
MarkPart name
BLDC Fan motor
Disk motor
Micro Switch
Step Motor
MAIN PCB ASSY
3
2
1
BLUE
BROWN
3
2
1
RED
BLACK
3
2
1
BLUE
CN1
CN10
CN8
PLASMA PLASMA negative ion generator
321
BLACKRED
YELLOW
BODY ASSY
N
L
BLACK
3
2
1
3
2
1
RED
GREEN
BLACK
CN5
HUMID
DM
3
2
1
RED
CN9
BLACK
PLASMA
5
4
6
YELLOW
WHITE
BLUE
BLDC
3
2
1
RED
BROWN
CN7
5
4
PINK
YELLOW
STEP
ORANGE
3
2
1
3
2
1
RED
BLACK
WHITE
DUST
CN4
RESERVOIR ASSY
CN2CN6
MSW
WATER LEVEL SENSOR
HUMIDHumid Sensor PCB ASSY
DUSTDust Sensor
DETECT
GND
DETECT Water Level Detection Rod
GNDGround Rod
21
REDBLACK
CN11
WLAMP
WLAMPWater Lamp
Connector
4
4
EN10
Operating manual – air washer AW 20 S
Page 12
Exploded assembly drawing
Note!
The position numbers of the spare parts differ from those
describing the positions of other parts mentioned in this
operating manual.
In the European Union, electronic equipment must not be
treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2002/96/EC of the
European Parliament and of the Council of 27January 2003 on
waste electrical and electronic equipment (WEEE). At the end of
its life, please dispose of this device according to the valid legal
requirements.
11EN
Operating manual – air washer AW 20 S
Page 13
Declaration of conformity
in accordance with the EC Low Voltage Directive 2006/95/EC
and the EC Directive 2004/108/EC about electromagnetic
compatibility.
Herewith, we declare that the device AW 20 S was developed,
constructed and produced in compliance with the named EC
directives.
Applied standards:
EN 55014-1:2006+A1:2009+A2:2011
EN 6100-3-2:2006+A1:2009+A2:2009
EN 61000-3-3:2008
EN 55014-2:1997+A1:2001+A2:2008
EN 60335-2-98:2002+A1:2004+A2:2008
EN 60335-1:2010
marking is found on the rear of the device.
The
Manufacturer:
Trotec GmbH & Co. KG
Grebbener Straße 7
D-52525 Heinsberg