TrolMaster Aqua-X NFS-1 Instructions Manual

Aqua-X Controller
PLEASE READ FIRST INTRODUCTION
Congratulations on your purchase of the NFS-1 Controller . This unit is an efficient way to fully control safety, please read this the instructions herein. It help
to set up or application of this product, other than for its original intended purposes reference.
the unit, and to understand its full capability. Any use
are prohibited. Store this manual in a secure place for future
your irrigation systems. To ensure
will provide detailed instructions that will
CONTENTS
1. Introduction 03
2. Facts 04
3. Components 05
4. Installation 06
5. Connections 07-09
6. Buttons 10
7. Start Settings 11
8. Main Menu 12-13
9. Setting Page 14
10. 110V Board Settings 15-19
11.24V Board Settings 19
12. Water Detector Setting 20-23
13. Alarm Settings 24-26
14. System Settings 27-32
15. General Information 33
16. Registration 34
17. Troubleshooting 35-36
18. Specifications 37
Aqua-X Irrigation Controller is a pioneering and innovational hydroponic irrigation control system. This smartphone App based system can control up to 30 outputs (24V or 110V) and monitor the pH, EC and water temperature of nutrient. Water detectors for watering allow the system to send alerts to user when the watering schedule failed. With its incredible flexibility, everyone could easily automate their irrigation systems.
The system could control pumps by 110V Control Board and solenoid valves by 24V Control Board. With the massive control outputs, user could manager delivery schedules for multiple nutrients, multiple rooms and multiple zones.
A sensor board with EC/pH/Temp sensors is also available to allow user to monitor and log all the historical data of their nutrients. When the measured value exceeds your custom setting range, a warning message will be sent to your smartphone.
Free smartphone App allows user to monitor and control their watering schedules at their fingertips. Graphic interface makes multiple schedules easy to adjust and monitor. The innovational watering confirmation feature saves enormous loss by watering failures.
confirmation
02 03
FACTS
Here are some important things to consider when using the Aqua-X Irrigation Controller .
Each set of Aqua-X Irrigation Controller can connect up to 30 outputs (24V or 110V) and monitor the pH value, EC value and water temperature of nutrient. There are two RJ12 ports for the Control Board. One is for 24V Control Board (6 individually controlled 24V outputs for solenoid valves), the other is 110V Control Board (6 individually controlled 110V outputs for water pumps). The maximum number of connections to the Aqua-X is 5 pieces for either 24V Control Board or 110V Control Board. The Program Device Station (DSP-1 from Hydro System) is also compatible to the Aqua-X through the 110V CONTROL port. 24V Control Board (6 outputs each), 110V Control Board (6 outputs each) and Program Device Station (1 output each) can be used together but each Aqua-X can only control up to 30 outputs. The Water Detector port looks identical to the Control Board port. Make sure not to mix them up. The Water Detector port is positioned between the Sensor Board port Micro SD slot. pH Sensor and EC/Temp Sensor should be connected to Sensor Board (AMP-2) and then connect the Sensor Board to the Aqua-X with a mini-DIN cable. A maximum distance of 1000ft / 300 meters between the NFS-1 Irrigation Controller and the devices to be controlled. Follow all local and national electrical codes for installation requirements.
COMPONENTS
4
5
1 . Aqua-X Controller (NFS-1) 2 . Water Detector (WD-1) 3 . Water Touch Spot 4 . Back Plate (Bracket) 5 . 12 VDC Power Supply
04 05
INSTALLATION
Determine where to locate the main controller. The controller comes with a simple to use DIN type bracket. Pull the 4 tabs outward to release the bracket from the unit, mount the bracket to a wall or surface, place the unit back on the bracket and press the 4 tabs back in to lock the unit in place.
CONNECTIONS
MICRO SD
WATER
DETECTOR
BOARD
SENSOR
CONTROL
24V
CONTROL
110V
INTERNET
SENSOR BOARD
Water Detectors
pH
Sensor
Sensor
EC/TEMP
DC
110V Control Boards
24V Control Boards
06 07
CONNECTIONS CONTINUED...
1. Power Connection:
Connect the plug-in power supply to the power (DC) connector on the far left.
2. Control Boards (24V or 110V) Connection
Connect the 24V Control Board to the Aqua-X with a RJ12 cable going from the 24V CONTROL socket to the first 24V Control Board to be connected. Plug the 24V Control Board to the wall outlet for power supply. Press "Addressing" button, the Aqua-X Controller will assign an address to the connected Control Board in sequence. Use another RJ12 cable to connect to the second 24V Control Board. Repeat this process until all 24V Control Boards (up to 5pcs for exclusive use) have been connected to the Aqua-X Controller.
The connection of 110V Control Boards is similar to above processes but through the 110V CONTROL port.
3. Program Device Station Connection:
The connection of Program Device Station is similar to the 110V Control Board. The 110V Control Board and Program Device Station can be chained together with T-Splitter through the 110V CONTROL socket.
4. Water Detectors Connection:
Connect the Water Detector to the Aqua-X with a RJ12 cable going from the Water Detector socket to the first Water Detector to be
connected. Use the cable can continue on to be
Detector) to be connected. Press the “Addressing” button, the controller will automatically assign an address to the Water Detector in sequence. Repeat this process until all Water Detectors (up to 30pcs connected to the main controller.
T-Splitter and a short RJ cable so that the first
connected to the next T-Splitter (Water
per set) are
5. Sensors Connection:
Connect the Sensor Board to the Aqua-X with a round-headed cable (male-to-male). Connect the pH Sensor and EC/Temp Sensor to the corresponding connector on the Sensor Board.
6.Internet Connection
This unit has the feature of connecting the network for remote control. User can use a standard network cable for connection through the INTERNET socket.
08 09
BUTTONS
The NFS-1 Aqua-X Controller is extremely easy to use. The backlit 128x128 LCD display will provide the user with the current conditions and access all settings. All settings are accessed by using the 6 push buttons on the front of the unit. The button functions are described below.
START SETTINGS
Once you have connected 24V Control Board, 110V Control Board(s), Sensor Board(s) and Water Detectors to the NFS-1 Controller , we can start using the unit.
Connect the plug-in power supply to the power connector on the bottom of the NFS-1 Controller . NFS-1Controller will turn on and boot up.
If it is the first time you have used the NFS-1Controller , when you power on the NFS-1 Controller , the Welcome screen / page will display and remind user to press “ENTER” to set system time.
Welcome to
Aqua-x
Control Sustem
Press ENTER to
set system
time
First-Use Welcome Page
NOTE: Press theENTER button to set system time before use.
TrolMaster
Aqua-x
Control System
V-0.3
Normal Start Page
UP / DOWN: The UP and DOWN buttons move the cursor up and down
to select
the item on the LCD display.
LEFT / RIGHT: The LEFT and RIGHT buttons move the cursor to previous
page or next page, left item or right item.
Time Setting: please refer to P23 for the time setting so as to change the default
time into the current time before use.
BACK: The BACK button goes backwards to the previous page. ENTER: The ENTER button is used to open the menu item to be
changed
as well
as to accept and save the new setting.
Familiarize yourself with the function of the 6 buttons on the front of the NFS-1 Controller in order to able to access settings, and to better understand how to use the NFC-1 Control System to its greatest
00 00 00
Jan 01 2018
16 15 58
Mar 08 2018
potential.
Default Time
10 11
Current Time (Example)
MAIN MENU
Alarm Messag e
. pH Sensor Senso
03 : 57 01/25 2000
. EC Sensor Senso
03 : 57 01/25 2000
. Temp Senso r Senso
03 : 57 01/25 2000
Wate r D ete cto r
110 VA1110 V
3
B1
24 V
A1
2 .9 EC
75.2 F
5.9 pH
2.9 EC
75.2 F
5.9 pH
1). The main menu displays three elements:
EC Value e.g.: 2.9 pH Value e.g.: 5.9 Water Temperature Value (°F) e.g.: 75.2°F
The top title bar indicates current date & time:
Month/Date e.g.: 09/07 Hour/Minute e.g.:18:20
Icon Indication: Alarm Activated
Internet Connected
NOTE: Download the TrolMaster App from App Store or Google
Play.
Alarm Message Page
Main Menu PageWater Detector Page
1). On the Main Menu page, press LEFT button to get access to Water Detector page. It shows output(s) that has(have)
the connected Water Detector. Press LEFT button again, the LCD screen
been associated with
will show the Alarm Message page. The LCD screen will show records of all alarm messages.
Alarm Messag e
2 .9 EC
75.2 F
5.9 pH
RIGHT
. pH Sensor Senso
03 : 57 01/25 2000
. EC Sensor Senso
03 : 57 01/25 2000
. Temp Senso r Senso
03 : 57 01/25 2000
RIGHT
Main Menu Page Water Detector PageAlarm Message Page
2).
On the Main Menu page, press RIGHT button to get access to Alarm
Message page. The LCD screen will show records of all alarm messages.
Press RIGHT button again, the LCD screen will show the Water Detector page. It shows the only one output (110V or 24V) that has been associated
Wate r D ete cto r
110 VA1110 V
3
B1
24 V
A1
with the connected Water Detector.
NOTE: Hot-plug is not recommended for the MicroSD card on the main
page. Damage to the files within the MicroSD card is a possible result.
12 13
SETTING PAGE
2.9 EC
75.2 F
5.9 pH
Alarm Mes sage
. pH Sensor Sens o
03 : 57 01/25 2000
. EC Sensor Senso
03 : 57 01/25 2000
. Temp Sensor Se nso
03 : 57 01/25 2000
110V BOARD SETTING
When the RJ12 cable is not correctly connected to the corresponding 110V
CONTROL port or the 110V Control Board is not connected to the power supply, Please make sure the RJ12 cable is correctly connected and power on the 110V Control Board. After power-on, will keep flashing every second. Then press the ADDRESSING button on the 110V Control Board, the LCD screen will display “110V Board A has been added”. The first connected Control Board will be marked as “A”, and the second one marked as “B”, the third as “C”, and so on.
the LCD screen will show “No 110V Board Online”.
the Addressing LED indicator
110V Board A
has been a dded
110V
Board Board
On the Main Menu page or Alarm Message page, press
24V
Alarm Sett ing System Setting
ENTER button to get access to the SETTING page. The LCD screen will display 4 subjects (110V Board, 24V Board , Alarm Setting and System Setting) as shown on above picture. You can press the respective
No 110V Board
Online
Wrong Connection Correct Connection
On the SETTING page, press ENTER button to enter the 110V Control Board list page. The connected Control Board(s) will be shown page to page. User can press RIGHT button to select the 110V Control Board (A, B, C…) for the setting change.
button (UP/DOWN/LEFT/RIGHT) to select the subject that you want to adjust the setting.
14 15
When the Control Board is selected, press ENTER button and the 1st output will be highlighted and blinking. Press LEFT, RIGHT, UP or DOWN button to select the output such as 110V A1. Press ENTER button to confirm and enter the SETTING page of that output.
110 V
A
110V
24V
Board Board
Alarm Sett ing System Setting
110 VA1110 VA2110 V
Board
110 VA4110 VA5110 V
A3
A6
RIGHT
SETTING Page 110V Control Board A
110 V
B
110 VB1110 VB2110 V
Board
110 VB4110 VB5110 V
B3
B6
110V Control Board B
110 V
A1
By schedule
by recycle
110V A1 Setting Page
On the SETTING page of selected output such as 110V A1, press ENTER button and the tick icon on the “By schedule” will be highlighted and blinking. You can also press DOWN button to select “By recycle”. Press ENTER button to confirm and save the setting.
a. By schedule:
Once the “By schedule” setting is selected, user can press ENTER button to activate the setting for the 1 line of total 12 lines of schedules. The HOUR of “On at” time will be highlighted and blinking, which means that it’s ready for change. User can press UP or DOWN button to change the HOUR. Press ENTER button and the MINUTE of “On at” will be highlighted and blinking, user can press UP or DOWN button to change the minute. Press ENTER button and the MINUTE of “Time” will be highlighted and blinking, user can press UP or DOWN button to change the minute. Press ENTER button and the SECOND will be highlighted and blinking, user can press UP or DOWN button to change the second. Press ENTER button and the tick symbol will be highlighted and blinking. Finally, press ENTER button to confirm and save the changes and the LCD screen will display “Setting saved”.
Similarly, user can change the “On at” & “Time” for other schedules (up to 12 lines) as above processes.
110 V
On at Time
08:00 01m:10s
00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s
A1
110 V
On at Time
08:00 01m:10 s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s
110 V
A1
On at Time
08:00 01m:10s
00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s
A1
110 V
On at Time
08:00 01m:10s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s
A1
110 V
On at Time
08:00 01m:10s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s
A1
110 V
A1
On at Time
08:00 01m:10s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s 00:00 00m:00s
Setting saved
16 17
b. By recycle:
Once the “By recycle” setting is selected, user can press UP or DOWN button to select “Start”, “On time”, “Off time” & “Times” for change. Press ENTER button to activate the setting. For example, when “Start” selected, press ENTER button and the HOUR will be highlighted and blinking, user can press UP or DOWN button to change the hour. Press ENTER button and the MINUTE will be highlighted and blinking, press UP or DOWN button to change the minute. Finally, press ENTER button to confirm and save the change and the LCD screen will display “Setting saved”.
Similarly, user can change the “On time”, “Off time” and “Times” accordingly.
110 V
Sta rt
On time
Off time
Times
or
A1
08:00
05m 10s
01h 10m
3
110 V
Sta rt
On time
Off time
Times
Setting saved
A1
08:00
05m 10s
01h 10m
5
Sta rt
On time
Off time
Times
Setting saved
110 V
A1
08:00
05m 10s
01h 10m
3
110 V
Sta rt
On time
Off time
Times
110 V
Sta rt
On time
Off time
Times
A1
08:00
05m 10s
01h 10m
3
A1
08:00
05m 10s
01h 10m
3
Sta rt
On time
Off time
Times
Setting saved
110 V
A1
08:00
05m 10s
01h 10m
3
110 V
Sta rt
On time
Off time
Times
Sta rt
On time
Off time
Times
110 V
A1
08:00
05m 10s
01h 10m
3
A1
08:00
05m 10s
01h 10m
Sta rt
On time
Off time
Times
3
Sta rt
On time
Off time
Times
110 V
110 V
A1
08:00
05m 10s
01h 10m
3
05m 10s
01h 10m
A1
08:00
3
110 V
Sta rt
On time
Off time
Times
Setting saved
A1
08:00
05m 10s
01h 10m
3
24V BOARD SETTING
The setting of 24V Board Setting is similar to the 110V Board Setting.
18 19
WATER DETECTOR SETTING
Aqua-x Controller Water Detector
Leak Sensor
(Leak Detection Mode)
Assignment
(Output Assigned Mode)
Wate r D ete cto r
1
Wate r D ete cto r
110 V
A1
Wate r D ete cto r
24 V
A1
1
110 V
A1
24 V
A1
a.Leak Sensor (Leak Detection Mode)
The default function of Water Detector (WD-1) is to do leak detection and the symbol is a triangle shown in the Aqua-X Controller. When WD-1 detects water leakage, it will send alarm message to your Smartphone one minute later. You can also check the alarm message in the Aqua-X Controller.
Wate r D ete cto r Wate r D ete cto r
110 V
A1
110 V
A1
Leak Sensor
Assignment
Detector 1
110 V
A1
Detector 1
Leak Sensor
Assignment
110 V
A1
Detector 1
Setting saved
Wate r D ete cto r
1
Assignment converted into Leak Sensor
If the Water Detector is NOT in original default function (leak sensor), you can change the Assignment into Leak Sensor as above processes.
20 21
b. Assignment (Output Assigned Mode)
The default mode of Water Detector is in Leak Sensor (Leak Detection Mode). You can change the Leak Detection Mode (Leak Sensor) into Output assigned Mode (Assignment) as below processes. As one Water Detector can be assigned to only one output on any Control Board, you need to select 24V or 110V and one of six outputs to be assigned with the Water Detector. When the output has been successfully assigned, the Water Detector will send alarm message to your Smartphone one minute later when it detects no water on the reservoirs of the irrigation system.
Detector 1
Setting saved
Wate r D ete cto r
110 V
A1
Wate r D ete cto r
24 V
A1
Aqua-X Controller
110 V
A6
24 V
A6
Water Detector
Wate r D ete cto r
1
Leak Sensor
Blinking
Assignment
Blinking
110 V
A1
or
24 V
A1
Wate r D ete cto r
1
110 V
A1
or
24 V
A1
or
Detector 1
Leak Sensor
Assignment
110 V
Detector 1
Leak Sensor
Assignment
110 V
A1
110 V
or
A1
24 V
NOTES:
1.
Each Water Detector can be assigned to a Control Board
which has been successfully assigned to the Aqua-X Controller. The Water Detector can not be assigned to an unassigned Control Board.
2. One Water Detector can be
assigned
to only one 24V or 110V output. One Aqua-X Controller can connect up to 30pcs Water Detectors.
3.
If the
assigned
output of that board is offline, the output symbol
will
blink on the LCD display of the Aqua-X Controller.
A1
or
A1
110 V
A6
or
24 V
A6
4. If the output is successfully and the Water Detector is connected with the Aqua-X Controller,
there is a dot before the
interface as below illustration.
Dot
(Indicating Assigned
Output)
Control Board Interface
assigned
assigned
110 V
C
110 VC1110 VC2110 V
Board
110 VC4110 VC5110 V
C3
C6
with the Water Detector
output on the Control Board
Dot
(Indicating Assigned
Output)
22 23
ALARM SETTING
On the Setting page, press DOWN button to select the Alarm Setting. Press ENTER
button and the LCD screen will display three Settings for selection: EC Alarm,
Temp Alarm and pH Alarm. User can press UP button or DOWN button to select
anyone of them for setting.
Alarm Sett ing
110V
Board Board
Board
24V
Alarm Sett ing
System Setting
EC Alarm
Temp Alarm
Board
pH Alarm
User can also press DOWN button to select the MAX value directly
value is similar to setting of MIN value.
for change if keeps unchanged for the MIN value. The setting of MAX
b.Temp Alarm:
When the Temp Alarm is selected, press the ENTER button to enter the
Temp Alarm setting page. The LCD screen will display the MIN value and MAX value. Press ENTER button to activate the setting page and the MIN value will be highlighted and blinking. Press UP button or DOWN button to change the MIN value, then press the ENTER button to confirm and save the change. The LCD screen will show “Setting saved”.
a.EC Alarm:
When the EC Alarm is selected, press ENTER button to enter the EC Alarm setting page. The LCD screen will display the MIN value and MAX value. Press ENTER button to activate the setting page and the MIN value will be highlighted and blinking. Press UP button or DOWN button
Alarm Sett ing
EC Alarm
Temp Alarm
Board
pH Alarm
Temp Setti ng
MIN : 60 F
Board
MAX : 90 F
to change the MIN value, then press the ENTER button to confirm and save the change. The LCD screen will show “Setting saved”.
Alarm Sett ing
EC Alarm
Temp Alarm
Board
pH Alarm
MIN : 1.0
Blinking
EC Setting
MIN : 1.0
Board
MAX : 2.5
or
MIN : 1.2
MIN : 60 F
Blinking
Setting saved
User can also press the DOWN button to select the MAX value directly
or
MIN : 62 F
Temp Setti ng
MIN : 62 F
Board
MAX : 90 F
for change if keeps unchanged for the MIN value. The setting of MAX
EC Setting
Setting saved
24 25
MIN : 1.0
Board
MAX : 2.5
value is similar to setting of MIN value.
c. pH Alarm:
When the pH Alarm is selected, press the ENTER button to enter the pH Alarm setting page. The LCD screen will display the MIN value and MAX value. Press ENTER button to activate the setting page and the MIN value will be highlighted and blinking. Press UP button or DOWN button to change the MIN value, then press the ENTER button to confirm and save the change. The LCD screen will show “Setting saved”.
Alarm Sett ing
EC Alarm Temp Alarm
Board
pH Alarm
MIN : 5.0
Blinking
Setting saved
or
pH Setting
MIN : 5.0 F
Board
MAX : 7.0 F
MIN : 5.5
pH Setting
MIN : 5.5
Board
MAX : 7.0
User can also press DOWN button to select the MAX value directly for
change if keeps unchanged for the MIN value. The setting of MAX
value
is similar to setting of MIN value.
SYSTEM SETTING
On the Setting page, press DOWN button to select the System Setting. Press ENTER button and the LCD screen will display five Settings for selection: Temp Format, Time Setting and Serial Number, System Reset, Calibration. User can press UP button or DOWN button to select anyone of them for setting.
Sy ste m
110V
Board Board
Board
24V
Alarm Sett ing
System Setting
Temp Format Time Setti ng Serial Num ber
Board
System Reset Calibration Em er ge nc y S top
a.Temp Format:
When the Temp Format is selected, press the ENTER button and the temperature symbol F or C will be highlighted and blinking. Press UP or DOWN button to convert the temperature format between F and C. Finally, press ENTER button to confirm and save the change. The LCD screen will display “Setting saved”.
Sy ste m
Temp Format Time Setti ng Serial Num ber
Board
System Reset Calibration Em er ge nc y S top
Setting saved
F
F
Blinking
Sy ste m
Temp Format Time Setting Serial Numbe r
Board
System Reset Calibration
Eme rg en cy Sto p
C
F
or
C
26 27
b.Time Setting:
When the Time Setting is selected, press ENTER button and the LCD display will show the default time if it’s the first time to use this unit. The time consists of two lines:
st
1
line: HOUR : MINUTE : SECOND
2nd line: MONTH : DATE : YEAR
Sy ste m
Temp Format
Time Setting
Serial Numbe r
Board
System Reset Calibration
Eme rg en cy Sto p
C
Time Settin g
00 : 00 : 00
Jan : 01 : 2018
Default Time
Time Settin g
11 : 00 : 00
Jan : 01 : 2018
Current Time
(Example)
Press ENTER button and the HOUR will be highlighted and blinking. Press UP or DOWN button to change the hour. Press ENTER button again and the cursor will skip to the next, the MINUTE will be highlighted and blinking. Similarly, you can change the MINUTE and SECOND. When the 1st line of time (HOUR:MINUTE:SECOND) has been changed, press ENTER button and the LCD screen will display “Setting saved”.
The date setting (MONTH:DATE:YEAR) is similar to above time setting.
c . Serial Number:
When the Serial Number column is selected, press ENTER button and the LCD display will show the QR code and serial number.
Sy ste m
Temp Format Time Setti ng
Serial Num ber
Board
System Reset Calibration Em er ge nc y S top
F
Serial Nu mber
Board
001EC0FB494B924F
Sy ste m
Temp Format
Time Setting
Serial Numbe r
Board
System Reset Calibration
Eme rg en cy Sto p
Time Settin g
11 : 45 : 09
Mar : 17 : 2018
C
Time Settin g
11 : 45 : 09
Mar : 01 : 2018
Time Settin g
11 : 00 : 00
Jan : 01 : 2018
......
......
Setting saved
Setting saved
28 29
d . System Reset:
When the System Reset column is selected, press ENTER button and the LCD display will show Device Reset, Factory Reset, Firmware Updateand Iot FW Update. Press UP button or DOWN button to select anyone of them for setting.
Sy ste m
Temp Format Time Setti ng Serial Num ber
Board
System Reset
Calibration Em er ge nc y S top
F
e. Calibration:
When the Calibration column is selected, press ENTER button and the LCD display will show Calibrate EC, Calibrate pH7.0, Calibrate pH4.0. Press UP
button or DOWN button to select anyone of them
for calibration.
Sy ste m
Temp Format Time Settin g Serial Num ber
Board
System Reset
Calibration
Em er ge nc y S top
F
System Reset
Device Reset
Factory Reset Firmware Update lot FW Update
Firmware : V_0 . 3
Device Reset
Press “’ENTER to reset all decices address
Reset all
devices address
done
System Reset
Device Reset
Factory Reset
Firmware Update lot FW Update
Firmware : V_0 . 3
Factory Reset
Press “’ENTER to reset to factory settings
Factory Reset
Factory Reset
com p le te
Please restart
System Reset
Device Reset Factory Reset
Firmware Update
lot FW Update
Firmware : V_0 . 3
Firmware Update
Press “’ENTER to reset to factory settings
Warning : No SD card De tec ted
Pl ea se insert SD card
System Reset
Device Reset Factory Reset Firmware Update
lot FW Update
Firmware : V_0 . 3
lot FW Update
Press ENTER to check wlan_ iot . hex and update iot module f irmware
lot FW Update
No SD card de tec ted
Pl ea se insert SD card
NOTE : For the Firmware Update and Iot FW Update, make sure to
insert the MicroSD card with the latest version of upgrade software.
Calibration
Cal i b ra t e EC
Calibrate pH 7 . 0 Calibrate pH 4. 0
Cal i b r a te EC
EC: 0 . 0
cal i b ra te EC
to 1 . 4
Press “’ENTER to confirm
Calibration su cces s fu l
Calibration
Cal i b ra t e EC
Calibrate pH 7 . 0
Calibrate pH 4. 0
Calibrate pH
EC: 7. 9
cal i b ra te EC
to 7 . 0
Press “’ENTER to confirm
Calibration
error
Out of range
Calibration
Cal i b ra t e EC Calibrate pH 7 . 0
Calibrate pH 4. 0
Calibrate pH
EC: 7. 0
cal i b ra te EC
to 4. 0
Press “’ENTER to confirm
NOTES:
1). Please note there are two results for the calibration. One is successful, the other is unsuccessful (failure).
2). Please calibrate pH7.0 first. Calibration pH4.0 should be processed after the calibration pH7.0 within half an hour.
3). Before calibration, the corresponding probe should be placed in the corresponding standard solution and allowed to stand for more than 1 minute.
30 31
f. Emergency Stop
The Emergency Stop function can be selected when there is abnormal condition found on the Control Boards. Press the DOWN button to select “Emergency Stop” and then press the ENTER button to confirm your selection. The LCD screen of Aqua-X will show “Auto Resume in 30 min” and then show “Resume” automatically in 30 minutes. If without midway intervention by pressing the ENTER button.
On the same interface, press the ENTER button again, the Emergency Stop function will be activated again.
Sy ste m
Temp Format Time Setting Serial Numb er
Board
System Reset Calibration
Em erg e nc y S top
F
Auto Resume
Board
in 30 min
Sy ste m
Temp Format Time Setting Serial Numb er
Board
System Reset Calibration
Resume
F
NOTES:
1. When the “Emergency Stop” function is selected, all devices on the all boards(24V & 110V ) will stop working for half an hour and then resume to work in 30 minutes.
Press the ENTER button again and all
devices on the all boards will stop working for another half an hour.
2. In the stop mode, press the ENTER button within 30 minutes and the stop mode will be cancelled immediately, and return to normal working state.
GENERAL INFORMATION
WARRANTY
Aqua-X Irrigation Controller (NFS-1) only uses high quality components. Under normal operating conditions, the mechanical and electronic components are covered by a three-year warranty from the original date of purchase. For service return the NFS-1 Irrigation Controller in the original packaging to your shop with the original sales receipt.
Components that are excluded from warranty are components that have failed due to abnormal usage.
In the case of defects of the Aqua-X Irrigation Controller (NFS-1), the Controller will either be replaced or repaired using new or reconditioned products or parts. If the Controller will be replaced this limited warranty shall apply to the replacement product for the remaining initial warranty period, i.e. (three) 3 years from the dateof purchase of the original product.
32 33
REGISTRATION
TrolMaster Agro Instruments Co., Ltd. will occasionally release
updated firmware for the Aqua-X Irrigation Controller (NFS-1) .
By registering your NFS-1 Irrigation controller on our website
www.trolmaster.com, we can notify you when an update is available.
TROUBLESHOOTING
Some of the most common issues or problems can be found within this section.
Before returning the unit for service, please consult the troubleshooting points
below, additional information can be found online at www.trolmaster.com
We will not sell, rent or share your personal information.
The Aqua-X Irrigation Controller (NFS-1) is
connected to power, but it does not seem
to be working / no display.
The Temperature, pH, EC values on the main
screen display horizontal line or flashing.
BELL icon is flashing.
OA6-24, OA6-110, DSP-1 or WD-1 can not
be added to the Aqua-X Controller.
Water sensor associated output failed.
The setting parameters are cleared.
The total number of three devices OA6-24,
OA6-110 & DSP-1 is less than 5pcs, but can
not continue to add a new device.
Check the low-volt power supply is plugged
incorrectly to the Aqua-X Irrigation Controller
(NFS-1).
Horizontal line indicates the corresponding
s
ensor error, flashing indicates the corresponding
value exceeds the alarm range.
It indicates that there is an alarm state. Alarm
status includes temperature, pH, EC value
exceeds range orwater sensor alarm.
Check if mix up input ports. 24 CONTROL
port for OA6-24, 110V CONTROL port for
OA-110 & DSP-1, WATER DETECTOR port
for WD-1. Check if the number of connected
device exceeds its maximum (max. 30pcs for
WD-1, max. 5pcs for 24 or 110V Control
Board & DSP-1).
The same output can only be associated with
a water sensor.
If the added board is offline and a new board
is added at the same position, the setting
parameters of that board and the setting
parameters of its associated water sensor will
be cleared.
Remove one or more devices with the same
voltage after adding 5 devices (110V or 24V,
DSP-1 belongs to 110V device), it is no longer
possible to add any device with the same
voltage. If need to add more, you need to process “System Reset Device Reset ” to
clear all device addresses.
34 35
Cannot connect to the network.
SPECIFICATIONS
Please make sure that the network path is
workable (you can check whether the network
cable is workable to any Internet-connected device).
The microSD card is damaged.
Please do not pull out the microSD card on the
main interface (displaying current temperature,
pH, EC values).
Aqua
Aqua
OA6-24 24V Control Board:
OA6-110 110V Control Board:
DSP-1 Program Device Station:
AMP-2 Sensor Board:
PCT-1 or PCT-2 EC/Temp Sensor:
PPH-1 or PPH-2 pH Sensor: WD-1 Water Detector : Max. 30pcs per set
pH Alarm Setpoint Range 0~14
EC Alarm Setpoint Range 0~5
Temp Alarm Setpoint Range 32°- 122°F
pH Alarm Default Value 5~7
EC Alarm Default Value 1~2.5
Temp Alarm Default Value 63°- 70°F
Max Distance to Device to be connected
Max. 5pcs per set
Max. 5pcs per set
Max. 5pcs per set
Note: combination application
is workable for the three
components, but the total qty
can not exceed 5pcs.
Max. 1pc per set
Max. 1pc per set
Max. 1pc per set
1000 meters
Remarks: combined application is available for 24V Control Board (6 outputs each), 110V Control Board (6 outputs each) and Program Device Station (1 output each) but control up to 30 outputs per set.
36 37
Loading...