PROFESSIONAL LED Lighting USER MANUAL
WALLY 136
KEEP THIS MANUAL FOR FUTURE NEEDS

CAUTION!
For your own safety, please read this user manual carefully before you initial start-up.
Every person involved with the installation, operation and maintenance of this
device has to
- be qualified
- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire service life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the Internet
INTRODUCTION:
Thank you for having chosen this professional LED lighting.
You will see you have acquired a powerful and versatile device.
Unpack the device. Inside the box you should find:
1. The fixture device
2. One power cables
3. One XLR connection cable
4. One safety rope and this manual
5. bar-door
6. frost filter
Please check carefully that there is no damage caused by transportation. Should
there be any, consult your dealer and don’t install this device.

DESCRIPTION OF THE DEVICE
Features
• 3, 4 or 6 DMX channels selectable for numerous applications
• Equipped with 36 x 1 W LEDS: 12 x red, 12 x blue, 12 x green
• 100 000 hours LED life
• The LEDS can be controlled individually
• Switch-mode power supply
• Automatic power supply adaption between 100 and 240 Volts without power
selector
• Stepless RGB colour changing
• Programmable color-change speed and strobe effect
• DMX-controlled operation or stand alone operation with Master/Slave-function
• Strobe-effect with 1-18 flashes per second
• Programmed chaser
• Rainbow-effect with adjustable speed
• Advantages of LED-technology: Extremely long life, low power consumption,
minimal heat emission, defact maintenance free with brilliant light radiation
• DMX-control via every standard DMX-controller

(1) Housing
(2) LEDS
(3) Floor-stand
(4) Menu-button
(5) Up-button
(6) Down-button
(7) Enter-button
(8) Power input
(9) DMX output
(10) DMX-input

This device has left the factory in perfect condition. In order to maintain
this condition and to ensure a safe operation, it is absolutely necessary
for the user to follow the safety instructions and warning notes written in
this user manual.
Important:
Damages caused by the disregard of this user manual are not subject to warranty. The dealer
If the device has been exposed to temperature changes due to
environmental changes, do not switch it on immediately. The arising
condensation could damage the device. Leave the device switched off
until it has reached room temperature.
This device falls under protection-class I. Therefore it is essential that
the device be earthed.
The electric connection must carry out by qualified person.
The device shall only be used with rate voltage and frequency.
Make sure that the available voltage is not higher than stated at the end
of this manual.
Make sure the power cord is never crimped or damaged by sharp edges.
If this would be the case, replacement of the cable must be done by an
authorized dealer.
Always disconnect from the mains, when the device is not in use or
before cleaning it. Only handle the power cord by the plug. Never pull

out the plug by tugging the power cord.
During initial start-up some smoke or smell may arise. This is a normal
process and does not necessarily mean that the device is defective, it
should decrease gradually.
Please don't project the beam onto combustible substances.
Fixtures cannot be installed on combustible substances, keep more than
50cm distance with wall for smooth air flow, so there should be no
shelter for fans and ventilation for heat radiation.
If the external flexible cable or cord of this luminaire is damaged, it shall
be exclusively replaced by the manufacturer or his service agent or a
similar qualified person in order to avoid a hazard.
Please be aware that damages caused by manual modifications to the
device are not subject to warranty. Keep away from children and
non-professionals.
GENERAL GUIDELINES
This device is a lighting effect for professional use on stages, in
discotheques, theatres, etc.
This fixture is only allowed to be operated with the max alternating

current which stated in the technical specifications in the last page of this
manual, the device was designed for indoor use only.
Lighting effects are not designed for permanent operation. Consistent
operation breaks may ensure that the device will serve you for a long
time without defects. Do not shake the device.
Avoid brute force when installing or operating the device.
The device shall only be used complete with its protective shield.
While choosing the installation-spot, please make sure that the device is
not exposed to extreme heat, moisture or dust. The minimum distance
between light-output from the projector and the illuminated surface must
be more than 0.1 meter.
Operate the device only after having familiarized with its functions. Do
not permit operation by persons not qualified for operating the device.
Most damages are the result of unprofessional operation.
Please use the original packaging if the device is to be transported.
For safety reasons, please be aware that all modifications on the device
are forbidden.
If this device will be operated in any way different to the one described
in this manual, the product may suffer damages and the guarantee
becomes void. Furthermore, any other operation may lead to
short-circuit, burns, electric shock, lamp explosion, crash, etc.

INSTALLATION INSTRUCTIONS
Mounting the device
The installation of the effect has to be built and constructed in a way that it can
hold 10 times the weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an
appropriate safety rope.
Never stand directly below the device when mounting, removing or servicing the
fixture.
The operator has to make sure the safety relating and machine technical
installations are approved by an expert before taking the device into operation for
the first time.
These installations have to be approved by a skilled person once a year.

Cautions:
The effect should be installed outside areas where persons may reach it, walk by or
be seated.
Overhead mounting requires extensive experience, including amongst others
calculating working load limits, installation material being used, and periodic
safety inspection of all installation material and the device. If you lack these
qualifications, do not attempt the installation yourself. Improper installation can
result in bodily injury.
Before mounting make sure that the installation area can hold a minimum point
load of 10 times the device’s weight.
Connect the fixture to the mains with the power plug.

Overhead rigging
Screw the bolt of the clamp into the hold of the bracket, and tighten the screw
underneath.
Pull the safety-rope through the holes on the bracket of the base and over the
trussing system or a safe fixation spot. Insert the end in the carabine and tighten the
safety screw.

DMX-512 control connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller
and the other side to the male 3-pin XLR input of the LED lighting. You can chain
multiple LED lighting together through serial linking. The cable needed should be
two core, screened cable with XLR input and output connectors. Please refer to the
diagram below.
DMX-512 connection with DMX terminator
For installations where the DMX cable has to run a long distance or is in an
electrically noisy environment, such as in a discotheque, it is recommended to use
a DMX terminator. This helps in preventing corruption of the digital control signal
by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω
resistor connected between pins 2 and 3,which is then plugged into the output XLR
socket of the last fixture in the chain. Please see illustrations below.

OPERATION
1: Display menu:
Display “Blackout” function. When activated the
display will automatically blackout when not in use
FLIP( )
When “ON” this function rotate the display 180°
3 CH( )
3 dmx channels (rgb)
4 CH( )
4 dmx channels (rgb+master dim)
Unit functions as slave
MAST( )
Unit functions as master
CNTL( )
Unit functions in stand alone
BLAC( )

Sound-controlled run as Master
Sound-controlled run in Stand Alone
Microphone sensitivity
MOD1 ( )
Standard dimming option
MOD2( )
Acquiescence dimming option
EBOC( )
Change DMX address via external controller
HIGH( )
Restore factory default settings
Display's current software version
Remark:
1) You can control the fixture no matter in which mode. When the DMX signal is
out, the fixture will keep the last status of the DMX, and the manual mode would
be unavailable.
2) Instruction for the SPED and the FADE function in CHAS:
SPEED: The time one step would stay
FADE: The time that one step altered to next step

Example: we set SPEED ==1second, and FADE ==1second, the 1st step is Red
100% open, the 2nd step is green 100% open, the 3rd step is Blue 100% open. So,
the Chase would come out as:
1, The Red 100% open and stay for 1second (SPEED)
2, Then Red drop down from 100% to 0%, the same time Green from 0% to
100%, in 1second (FADE)
3, The Green stay 100% for 1second
4, Then Green drop down from 100% to 0%, the same time Blue from 0% to
100%, in 1second (FADE)
5, Blue stay 100% for 1second.
6,Then Blue drop down from 100% to 0%, the Red come up from 0% to 100%
3) Remote DMX addressing (RDMX) - This function allows the DMX address to
be changed remotely from a DMX console. This setting requires special settings
for both the controller and the fixture.
1. RDMX function may be turned on and off, and is “ON” be default. Follow the
procedure listed below to access the RDMX functions:
2. Fixture Settings:
a. Access the main menu and use the UP or DOWN to get to the “OTHr” menu,
then press ENTER
b. Once in the “OTHr” menu, tap the UP or Down to get to the “EBOC“ menu,
press ENTER.
c. “EBOC” is the function that turn the RDMX function on and off. Press ENTER
and be sure the function is turned on.

d. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
e. Press ENTER to confirm.
f. Press MODE/ESC to return to the main menu.
3. Controller Settings:
a. Set the DMX value of channel 1 to a value of 7.
b. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to
"7" you can adjust the starting address between 1 and 255. When set to "8" you can
adjust the starting address between 256 and 512.
c. Use channel 3 to set your desired DMX starting address. For example: If you
want to set the starting address to 57, set channel 1 to a value of “7,” set channel 2
to a value of “7” and use channel 3 to set your address to 57 by selecting a channel
value of 57. Example 2: If you want to set the starting address to 420, set channel 1
to a value of “7,” channel 2 to "8" and channel 3 to "164" (256+164=420).
4. Wait for approximately 20 seconds for the unit to complete the address reset
function.

DMX channel´s functions and their values (6 DMX channels):
Red ( 0-Black , 255-100% Red )
Green ( 0-Black , 255-100% Green )
Blue ( 0-Black , 255- 100% Blue )
dimming( 0-Black , 255- 100% )
No function (shutter open)
Strobe effect slow to fast
No function (shutter open)
Pulse-effect in sequences
No function (shutter open)

Random strobe effect slow to fast
No function (shutter open)
dimming( 0-Black , 255- 100% )
speed from slow to fast /when running internal
speed from slow to fast /when running gradient
effect
Instructions for installing the bar-door and frost filter:
For this device, the bar door and the frost filter can be istalled separately or
together.
1.When only install the frost filter, use the rotating clips on the lens cover to fix it.
2.When only install the bar door, release the 2 M4 screws on the lens cover, put on
the bar door and tighten the screws.
3.When install the bar door and frost filter together, release the 2 M4 screws, put
on the frost filter and the bar door one by one, then tighten the screws.

CLEANING AND MAINTENANCE
We recommend a frequent cleaning of the device. Please use a soft lint-free and
moistened cloth. Never use alcohol or solvents!
There are no servicable parts inside the device. Maintenance and service operations
are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by
authorized dealers only in order to avoid hazards.
Should you have further questions, please contact your dealer.
INSTALLATION
This device is only constructed for a standing installation. The device must only be
installed absolutely planar at a vibration-free, oscilation-free and fire-resistant
location. Make sure that the device is installed absolutely planar by using a
water-level.
TECHNICAL SPECIFICATIONS
Power supply: 100V~240V AC,50 / 60Hz
Power consumption: max. 60 W
Packing dimensions: 40 x 30 x 48 CM
Net weight: 7 KGS
Gross weight: 10KGS
Remark: errors and omissions for every information given in this manual except. All information
is subject to change without prior notice.