Tripp Lite UPS System User Manual

Multiple Outlet Strips (Relocatable Power Taps)
(p. 2 - 3)
HEAVY-DUTY ELECTRICAL
HEAVY-DUTY ELECTRICAL
COMMERCIAL/INDUSTRIAL PRODUCTS
COMMERCIAL/INDUSTRIAL PRODUCTS
Heavy-Duty Electrical Commercial/Industrial Products
Rack/Bench/Wall/Floor Mount Options
Tripp Lite's superior quality products, unmatched customer support and 85+ year
service history have built a trusted reputation for reliability among distributors
Maintenance, Education/Government and Healthcare.
Surge Suppressors
(p. 4 - 5)
DC-to-AC Power Solutions
(p. 8)
Circuit
Tester
(p. 5)
Heavy-Duty Electrical Commercial/Industrial Products • Heavy-Duty Electrical
Commercial/Industrial Products • Heavy-Duty Electrical Commercial/Industrial Products
Heavy-Duty Electrical Commercial/Industrial Products • Heavy-Duty Electrical
Commercial/Industrial Products • Heavy-Duty Electrical Commercial/Industrial Products
Heavy-Duty Electrical Commercial/Industrial Products • Heavy-Duty Electrical
Commercial/Industrial Products • Heavy-Duty Electrical Commercial/Industrial Products
Heavy-Duty Electrical Commercial/Industrial Products • Heavy-Duty Electrical
Commercial/Industrial Products • Heavy-Duty Electrical Commercial/Industrial Products
UPS Systems, PDUs, DC Power
Heavy-Duty Electrical Commercial/Industrial Products • Heavy-Duty Electrical
Supplies & AC Line Conditioners
(p. 7)
Commercial/Industrial Products • Heavy-Duty Electrical Commercial/Industrial Products
Heavy-Duty Electrical Commercial/Industrial Products • Heavy-Duty Electrical
Commercial/Industrial Products • Heavy-Duty Electrical Commercial/Industrial Products
Heavy-Duty Electrical Commercial/Industrial Products • Heavy-Duty Electrical
Commercial/Industrial Products • Heavy-Duty Electrical Commercial/Industrial Products
Heavy-Duty Electrical Commercial/Industrial Products • Heavy-Duty Electrical
Commercial/Industrial Products • Heavy-Duty Electrical Commercial/Industrial Products
Heavy-Duty Electrical Commercial/Industrial Products • Heavy-Duty Electrical
Healthcare Market/ Medical OEM Products
(p. 3 & 6)
UL 60601-1 Compliance Solutions
Commercial/Industrial Products • Heavy-Duty Electrical Commercial/Industrial Products •
Multiple Outlet Strips
(Relocatable Power Taps)
• Heavy-Duty Metal Housings
• Variety of Grades & Lengths
• Mount On Any Surface
4 – 24 outlets 7.38 – 72 in. long (including 19-in. rack)
19 rack/workbench/wall/floor mount models available!
AB
D
C
D
C
B
A
PS2408
AB
PS3612
• 3 – 24 Outlets
FEATURES
See page 3 for features of specific models.
Heavy-Duty Metal Housings
A
Stand up to the most demanding environments.
Illuminated On/Off Switch
B
Locking Switch Safety Cover
C
Prevents accidental shutoff.
D
Circuit Breaker
Guards against overloads.
E
Adjustable Mounting Clips
Provide secure mounting positions along the entire length of the outlet strip.
Adjustable Mounting Hardware
F
Provides secure rack, workbench, wall or floor mount.
G
Keyhole Slots or Flanges
Provide secure mounting.
Grounding Post
H
End-Mounted Outlet
I
Internal Fault Protection
J
Ensures UL 60601-1 compliance.
Hospital-Grade Outlets
K
D
D
B
D
C
B
C
E
Adjustable Mounting Clips
G
Keyhole Slots
C
C
PS4816
A
A
C
Locking Switch Safety Cover
PS6020
PS7224-20T
F
H
A
RS-1215 (front and rear panel)
3 – 10 outlets 7.38 – 17.5 in. long
15 workbench/wall/floor mount models available!
D
C
D
B
B
C
A
A
B
C
A
B CD
D
B
A
ORDERING:
Contact Tripp Lite to order Multiple Outlet Strips through a distributor near you: (773) 869-1234 • www.tripplite.com
2
Locking Switch Safety Cover
A
UL800CB-15
Mounting Options
Snap Mount Keyhole Mount
Measure and mark a
straight line. Mount clips.
G
3SP
C
B
D
F
G
6SP
6SPDX
G
UL17CB-15
Adjustable Mounting Clips (Snap/Keyhole) Adjustable clips included with "PS"*
and "SS" models are slide-adjustable to allow an infinite number of mounting positions along the entire length of the outlet strip. Snap mount or keyhole mount.
through the housing.
Snap outlet strip
into clips.
Measure and mark a
straight line. Drive screws.
* Except hardwire models, which permanently mount
Snap outlet strip
into clips.
Slide the mounting clips’ key-
hole slots over screw heads.
I
4 – 24 outlets 7.38 – 72 in. long (including 19-in. rack)
rack/workbench/wall/floor mount models
(A)
FEATURES
Model # L x W x D (in) Quantity NEMA Type Centers (in) Rating
Corded Models—UL1363
ABCDE PS2408 24 x 1.5 x 1.5 8 5-15R 2.48 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P Gray Adjustable Clip None ABCDE PS3612 36 x 1.5 x 1.5 12 5-15R 2.638 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P Gray Adjustable Clip None ABCDE PS4816 48 x 1.5 x 1.5 16 5-15R 2.717 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P Gray Adjustable Clip None ABCDE PS6020 60 x 1.5 x 1.5 20 5-15R 2.795 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P Gray Adjustable Clip None ABCDE PS7224 72 x 1.5 x 1.5 24 5-15R 2.795 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P Gray Adjustable Clip None A B C D E PS7224-20 72 x 1.5 x 1.5 24 5-15/ 20R 2.795 2400W (20A) Lighted/Protected 20A 15 ft. 12/3 5-20P Gray Adjustable Clip None
A B C D E PS7224-20T 72 x 1.5 x 1.5 24 5-15/ 20R 2.795 2400W (20A) Lighted/Protected 20A 15 ft. 12/3 L5-20P Gray Adjustable Clip None
Corded Models (with Surge Suppression)—UL1449
A B C D E SS7415-15 48 x 1.5 x 1.5 16 5-15R 2.717 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P Gray Adjustable Clip 450 Joules A B C D E SS7619-15 72 x 1.5 x 1.5 24 5-15R 2.795 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P Gray Adjustable Clip 450 Joules
Hardwire Models—UL5
A PS3612-20HW 36 x 1.5 x 1.5 12 5-15/ 20R 2.99 2400W (20A) Beige Permanent Mount None
A PS7224-20HW 72 x 1.5 x 1.5 24 5-15/ 20R 2.795 2400W (20A) Beige Permanent Mount None
19 In. Rackmount Models—UL-Recognized
ABCDFH RS-1215 (1U) 12 5-15R 1.776 (front) 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P Black Adjustable Hardware None
ABCDFH RS-1215-20 (1U) 12 5-15/ 20R 2.176 (front) 2400W (20A) Lighted/Protected 20A 15 ft. 12/3 5-20P Black Adjustable Hardware None
ABCDFH RS-1215-RA (1U) 12 5-15R 2.176 (front) 1800W (15A) Lighted/Protected 15A 15 f t. 14/3 5-15P Black Adjustable Hardware None
ABCDFH RS-1215-HG (1U) 12 5-15R HG
Hospital-Grade
(D)
Power Strips - UL1363 (See p. 6 for additional information.)
ADGK PS-415-HG 7.38 x 2.5 x 1.5 4 5-15R HG 1.51 1800W (15A) None 15A 15 ft. 14/3 5-15P HG White Keyhole/Flanges None ADGK PS-602-HG 12.5 x 2.5 x 1.5 6 5-15R HG 1.51 1800W (15A) None 15A 1.5 ft. 14/3 5-15P HG White Keyhole/Flanges None ADGK PS-606-HG 12.5 x 2.5 x 1.5 6 5-15R HG 1.51 1800W (15A) None 15A 6 ft. 14/3 5-15P HG White Keyhole/Flanges None ADGK PS-615-HG 12.5 x 2.5 x 1.5 6 5-15R HG 1.51 1800W (15A) None 15A 15 ft. 14/3 5-15P HG White Keyhole/Flanges None
Medical-Grade Power Strip - UL 60601-1 Tested, Certified and Compliant (See p. 6 for additional information.)
ADGJK PS-415-HGULTRA 13.75 x 2.5 x 1.5 4 5-15R HG 1.51 1800W (15A) None 15A 15 ft. 14/3 5-15P HG White Keyhole/Flanges None
(A)
See page 2 for key to features.
(Note: Multiple Outlet Strips do not provide surge suppression.) The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
Dimensions Outlet Outlet Outlet Electrical Circuit Cord Cord Plug Housing MOUNTING Surge Sup-
(C)
1.75 x 19
1.75 x 19
1.75 x 19
1.7 x 19
(B)
All models are rated to 120V AC, 50/60 Hz.
x 4 (6 front/6 rear) 4.995 (rear) (rack/bench/wall/floor)
(C)
x 4 (6 front/6 rear) 2.846 (rear) (rack/bench/wall/floor)
(C)
x 4 Right-Angled 2.846 (rear) (rack/bench/wall/floor)
(C)
x 3.5 (6 front/6 rear) 4.995 (rear) (rack/bench/wall/floor)
(6 front/6 rear)
(C)
(D)
1.776 (front) 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P HG Black Adjustable Hardware None
Designed for standard 19 in. racks. Unit width without mounting hardware is 17.5 inches.
(B)
Switch Breaker Length Type (SJT) NEMA-Type Color OPTIONS pression
(twist lock)
None (Hardwired)
None (Hardwired)
(D)
Not for use where NEC requires hospital-grade receptacles.
Through Housing
Through Housing
3 – 10 outlets 7.38 – 17.5 in. long
workbench/wall/floor mount models
FEATURES
(A)
Model # Quantity NEMA Type Centers (in.) Rating
Outlet Outlet Outlet Electrical Circuit Cord Type NEMA- Housing MOUNTING L x W x D (in)
(B)
Switch Breaker Length (SJT) Type Color OPTIONS (case only)
Commercial/Industrial Grade—UL1363
ABCDG 3SP 3 5-15R 1.75 1800W (15A) Lighted/Protected 15A 6 ft. 14/3 5-15P Blue/Gray Keyhole/Flanges 7.38 x 2.5 x 1.5 A B C D G UL603CB-6 4 5-15R 1.25 1800W (15A) Lighted/Protected 15A 6 ft. 14/3 5-15P Blue/Gray Keyhole/Flanges 7.38 x 2.5 x 1.5 ADG 602 5 5-15R 1.188 1800W (15A) None 15A 6 ft. 14/3 5-15P Blue/Gray Keyhole/Flanges 7.38 x 2.5 x 1.5 A D G 602-15 5 5-15R 1.188 1800W (15A) None 15A 15 ft. 14/3 5-15P Blue/Gray Keyhole/Flanges 7.38 x 2.5 x 1.5 ABCDG 6SP 6 5-15R 1.625 1800W (15A) Lighted/Protected 15A 6 ft. 14/3 5-15P Blue/Gray Keyhole/Flanges 12.5 x 2.5 x 1.5 A B C D G UL24CB-15 6 5-15R 1.625 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P Blue/Gray Keyhole/Flanges 12.5 x 2.5 x 1.5 A B C D G UL24RA-15 6 5-15R A B C D G UL620-15 6 5-15R/ 20R 1.625 2400W (20A) Lighted/Protected 20A 15 ft. 12/3 5-20P Blue/Gray Keyhole/Flanges 12.5 x 2.5 x 1.5 A B C D G I UL17CB-15 9
(D)
(C)
1.625 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P Blue/Gray Keyhole/Flanges 12.5 x 2.5 x 1.5
5-15R 1.125 1800W (15A) Lighted/Protected 15A 15 f t. 14/3 5-15P Blue/Gray Keyhole/Flanges 12.5 x 2.5 x 1.5
ABCDF UL800CB-15 10 5-15R Tandem 1800W (15A) Lighted/Protected 15A 15 ft. 14/3 5-15P Black Flanges 17.5 x 4 x 1.75
Office-Grade (Premium)—UL1363
A B D G 4SPDX 4 5-15R 1.250 1800W (15A) Lighted 15A, in switch 6 ft. 14/3 5-15P Beige Keyhole 7.38 x 2.5 x 1.5 A B G 6SPDX 6 5-15R 1.520 1800W (15A) Lighted 15A, in switch 6 ft. 14/3 5-15P Beige Keyhole 12.5 x 2.5 x 1.5 A B D G 6SPDX-15 6 5-15R 1.520 1800W (15A) Lighted 15A, in switch 15 ft. 14/3 5-15P Beige Keyhole 12.5 x 2.5 x 1.5
Office-Grade (Commercial)—UL1363
A B D G 6NX6 6 5-15R 1.520 1800W (15A) Lighted 15A, in switch 6 ft. 14/3 5-15P Beige Keyhole 12.5 x 2.5 x 1.5 D G PS6 6 5-15R 1.0 1800W (15A) Unlit 15A 4 ft. 14/3 5-15P White Keyhole 9.5 x 1.5 x 1
(A)
See page 2 for key to features.
(Note: Multiple Outlet Strips do not provide surge suppression.) The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
(B)
All models are rated to 120V AC, 50/60 Hz.
(C)
Features right-angled outlets to accept transformer blocks without covering other outlets.
Adjustable Mounting Hardware (Rack/Bench/Wall/Floor Mount)
Removable, adjustable hardware included with "RS" models and UL800CB-15 provides 4 separate secure mounting methods for a variety of applications, including rack, workbench, wall or floor mount.
Rack Mount
Bench Mount Wall Mount Floor Mount
Cord Plug Dimensions
(D)
UL17CB-15 features a single end-mounted outlet.
Keyhole Slots Keyhole slots on the bottom of all
Waber by Tripp Lite models provide secure mounting. Mounting Centers: all 7.38 inch long strips = 5 inches; all 9.5 inch long strips = 6.25; all 12.5 inch long strips = 8 inches.
Mount to rack using
rack screws.
Remove, reorient and reinstall hardware along
sides of outlet strip. Mount under bench.
Remove, reorient and reinstall hardware
along sides of outlet strip. Mount on wall.
Remove, reorient and reinstall hardware along
one side of outlet strip. Mount on floor.
Measure and mark a straight
line. Drive screws.
Slide the outlet strip’s keyhole
slots over screw heads.
3
Surge Suppressors
• Up to 3690 Joules
• Heavy-Duty Metal or Plastic Housings
• Mount On Any Surface
• 2 - 14 Outlets
FEATURES
See “Features” column in charts on page 5 for features of specific models.
Surge Suppression
A
All AC outlets protect against damaging surges and disruptive EMI/ RFI line noise.* Widely spaced outlets accept multiple transformers.
Heavy-Duty Metal Housings
B
Heavy-duty steel or extruded aluminum housings stand up to the most demanding environments.**
C
Standard-Duty Plastic Housings
High-impact plastic provides a durable, economical alternative in demanding environments.
Isolated Filter Banks
D
Premium-grade Isobar models feature isolated banks of receptacles that eliminate interference between connected equipment, reducing data errors and audio/video signal distortion.
E
Illuminated On/Off Switch
F
Locking Safety Cover Circuit Breaker
G
(Separate or Integrated)
Diagnostic LEDs***
H
Tel/Modem, Ethernet and/or
I
Cable/Satellite Surge Protection
Protects equipment from damaging surges on telephone/modem, network and/or cable/satellite lines.
Right-Angle Plug
J
Allows equipment and furniture to be moved flush against the wall.
Adjustable Mounting Hardware
K
Removable, adjustable hardware included with rackmount models provides secure mounting for a variety of applications including rack, workbench, wall or floor mount.
Keyhole Slots
L
Provide secure mounting for a variety of applications.
M
Grounding Post
Rackmount Heavy-Duty Metal Housing Surge Suppressors
12-14 outlets, 5 models available!
A
B
K
M
A D A D
ISOBAR12ULTRA (front and rear panel)
D
H
G
E
F
Metal Heavy-Duty Housing Surge Suppressors
4 – 8 outlets, 13 models available!
F
B
G
E
A D
H
ISOTEL6ULTRA DG115-SI
J
Right-Angle Plug
(select models)
I
L
Keyhole Slots
(all models)
B
A
E G
H
Plastic Standard-Duty Housing Surge Suppressors
2 – 10 outlets, 21 models available!
H
G
C
E
G
A
A
I
A
H
C
TLP810NETTLP1008TELTV
A
I
J
Right-Angle Plug
(select models)
L
Keyhole Slots
(select models)
C
G
C
H
A
I
SUPER7TEL TLP602
G
A
* DRS-1215 and DG206 do not provide EMI/RFI line noise filtering. **All metal housings are steel, except Isobar models which are extruded aluminum. *** TLP810NET, TLP810SAT and TLP808TELTV also include an audible alarm.
ORDERING:
Contact Tripp Lite to order Surge Suppressors through a distributor near you: (773) 869-1234 • www.tripplite.com
4
Mounting Options
Rack Mount Bench Mount Wall Mount Floor Mount
Mount to rack using
rack screws.
Adjustable Mounting Hardware (Rack/Bench/Wall/Floor Mount)
Removable, adjustable hardware included with rack mount models provides 4 separate secure mounting methods for a variety of applications, including rack, workbench, wall or floor mount.
Reorient hardware and reinstall along
sides of outlet strip. Mount under bench.
Reorient hardware and reinstall along
sides of outlet strip. Mount on wall.
Reorient hardware and reinstall along one
side of outlet strip. Mount on floor.
Rack Mount Heavy-Duty Metal Housing Surge Suppressors
OUTLET Surge UL1449 Isolated Plug
FEATURES Model # Qty. NEMA Type Rating edition) Height Rating Switch LEDs
Premium-Grade Isobar®—UL-Recognized
ABDEFGHKM ISOBAR12ULTRA 12 5-15R (2 front, 10 rear) 1280 330 1U 1800W (15A) Lighted/Protected 3 2 15 ft. 5-15P Black (1U) 1.75 x 19 x 3.75 ABDEFGHKM IBAR12 12 5-15R (2 front, 10 rear) 1280 400 1U 1800W (15A) Lighted/Protected 3 2 15 ft. 5-15P Black (1U) 1.75 x 19 x 3.75 A B E F G H K M IBAR12/20ULTRA 12 5-15R
(2 front) 1280 330 1U 2400W (20A) Lighted/Protected 3 15 ft. 5-20 P Black (1U) 1.75 x 19 x 3.75
5-15/ 20R (10 rear)
A B E F G H K M IBAR12-20T 12 5-15R
(2 front) 1280 330 1U 2400W (20A) Lighted/Protected 3 15 ft. L5- 20 P Black (1U) 1.75 x 19 x 3.75
5-15/ 20R (10 rear) (twist lock)
Commercial-Grade—UL-Recognized
A B E F G H K M DRS-1215
(A)
Models with 3 LEDs: Fault (indicates absence of proper outlet grounding); Line OK (indicates presence of AC power); Protection Present (indicates presence of sufficient surge suppression). Models with 1 LED: Protection Present (indicates presence of sufficient surge suppression). is 17.5 inches. subject to change without notice.
(D)
DRS-1215 includes 6 safety covers for use with unused outlets. All models include EMI/RFI line noise filtering (except DRS-1215). The policy of Tripp Lite is one of continuous improvement. Specifications are
(D)
14 5-15R (6 front/8 rear) 1050 400 1U 1800W (15A) Lighted/Protected 1 15 ft. 5-15P Black (1U) 1.75 x 19 x 3.75
(B)
15-amp models feature 14/3 SJT cord types; 20-amp models feature 12/3 SJT cord types.
Joules
Suppression (2nd Rack Electrical Filter Cord (NEMA Housing Dimensions
(C)
(A)
Banks Length
Designed for standard 19 inch racks. Unit width without mounting hardware
(B)
Type) Color L x W x D (in)
(C)
Metal Heavy-Duty Housing Surge Suppressors
Joules Surge Tel/Modem Isolated
Suppression UL1449 Surge Filter Cord Plug Housing Dimensions
FEATURES Model # Outlets
(A)
Rating (2nd edition) Protection Switch LEDs
Premium-Grade Tripp Lite Isobar®—UL1449
ABDEGHJL ISOBAR8ULTRA 8 2350 330 Lighted 3 4 12 ft. Right-Angle Beige 9 x 3.5 x 2.5 ABDEGHJL ISOBAR825ULTRA 8 2350 330 Lighted 3 4 25 ft. Right-Angle Beige 9 x 3.5 x 2.5 ABDEGHIJL ISOTEL8ULTRA 8 2850 330 1 line Lighted 3 4 12 ft. Right-Angle Beige 9 x 3.5 x 2.5 ABDEFGHJL ISOBAR6ULTRA 6 2350 330 Lighted/Protected 3 3 6 ft. Right-Angle Beige 7 x 3.5 x 2.5 ABDEFGHIJL ISOTEL6ULTRA 6 2850 330 2 line Lighted/Protected 3 3 6 ft. Right-Angle Beige 7 x 3.5 x 2.5 ABDEFGHJL ISOBAR4ULTRA 4 2200 330 Lighted/Protected 3 2 6 ft. Right-Angle Beige 6 x 3.5 x 2.5 ABDEFGHIJL ISOTEL4ULTRA 4 2700 330 1 line Lighted/Protected 3 2 6 ft. Right-Angle Beige 6 x 3.5 x 2.5
Commercial-Grade Waber-by-Tripp Lite—UL1449
A B E G H L DG115-SI 6 600 400 Lighted 1 6 ft. Straight White 12.5 x 2.5 x 1.5 A B E G H L DG206 6 450 400 Lighted 1 6 ft. Straight White 12.5 x 2.5 x 1.5 ABEGH PM6SN1 6 450 400 Lighted 1 6 ft. Straight Beige 12.5 x 2.5 x 1.5 ABEGH PM6NS 6 450 400 Lighted 1 6 ft. Straight Beige 12.5 x 2.5 x 1.5
Premium-Grade with Hospital-Grade Plug & Receptacles
ABDEFGHL ISOBAR6ULTRAHG 6 600 330 Lighted/Protected 3 1 15 ft. Hospital-Grade Beige 7 x 3.5 x 2.5
Commercial-Grade with Hospital-Grade Plug & Receptacles
ABGHL SPS-615-HG 6 450 400 None 1 15 ft. Hospital-Grade White 12.5 x 2.5 x 1.5
(A)
All outlets are NEMA 5-15R except on models ISOBAR6ULTRAHG and SPS-615-HG (NEMA 5-15R HG, hospital-grade). All models feature 14/3 SJT cord types. All "ISOBAR" models include safety covers for use with unused outlets.
(B)
Models with 3 LEDs: Fault (indicates absence of proper outlet grounding); Line OK (indicates presence of AC power); Protection Present (indicates presence of sufficient surge suppression). Models with 1 LED: Protection Present (indicates presence of sufficient surge suppression). are rated to 120V AC, 50/60 Hz. with an 1800W (15A) electrical rating and include EMI/RFI line noise filtering (except DG206). The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
(C)
All plugs are NEMA 5-15P except on models ISOBAR6ULTRAHG and SPS-615-HG (NEMA 5-15P HG, hospital-grade).
(D)
—UL1449
(D)
—UL1449
(B)
Banks Length Style
(D)
Not for use where NEC requires hospital-grade receptacles. All models
(C)
Color L x W x D (in)
Plastic Standard-Duty Housing Surge Suppressors
Joules Surge UL1449 Tel/Modem Coaxial Ethernet
Suppression (2nd Surge Surge Surge Cord Plug Housing Dimensions
FEATURES Model # Outlets
(A)
Rating edition) Protection Protection
Office-Grade Tripp Lite—UL1449
ACGHIJL TLP1008TELTV 10 3345 330 1 in/2 out 1 in/1 out Unlit 2 - 8 ft. Right-Angle Silver 11.6 x 5 x 2.25 ACGHIJL TLP1008TEL 10 2395 330 1 in/2 out Unlit 2 - 8 ft. Right-Angle Silver 11.6 x 5 x 2.25 ACEGHIJL TLP810NET 8 3690 330 2-line (1 in/1out) 1 in/1 out 1 in/1 out Lighted 2 Yes 10 ft. Right-Angle Black 9.25 x 4.25 x 1.5 ACEGHIJL TLP810SAT 8 3570 330 1 in/1 out 2 in/2 out Lighted 2 Yes 10 ft. Right-Angle Black 9.25 x 4.25 x 1.5 ACEGHIJL TLP808TELTV 8 3500 330 1 in/2 out 1 in/1 out Lighted 2 Yes 8 ft. Right-Angle Gray 9.25 x 4.25 x 1.5 ACEGHIJL TLP808TEL 8 2820 330 1 in/2 out Lighted 2 8 ft. Right-Angle White 9.25 x 4.25 x 1.5 ACEGHJL TLP808 8 1900 330 Lighted 2 8 f t. Right-Angle White 9.25 x 4.25 x 1.5 ACGHIJL SUPER7TEL15 7 2720 330 1 in/1 out Unlit 2 15 ft. Right-Angle White 10.25 x 2.75 x 1.5 ACGHIJL SUPER7TEL 7 2470 330 1 in/1 out Unlit 2 7 ft. Right-Angle White 10.25 x 2.75 x 1.5 ACGHIJL SUPER7COAX 7 2350 330 1 in/1 out Unlit 2 7 ft. Right-Angle White 10.25 x 2.75 x 1.5 ACGHJL SUPER7 7 2350 330 Unlit 2 7 ft. Right-Angle White 10.25 x 2.75 x 1.5 A C E G H I J TLP707TEL 7 1270 330 1 in/1 out Lighted 2 - 7 ft. Right-Angle Silver 10.75 x 2.25 x 1.5 ACGHIL SUPER6TEL12 7 1270 330 1 in/1 out Unlit 1 12 ft. Straight White 10.25 x 2.75 x 1.5 ACGHIL SUPER6TEL 7 1270 330 1 in/1 out Unlit 1 6 ft. Straight White 10.25 x 2.75 x 1.5 ACEGHL TLP712 7 1000 330 Lighted 1 12 ft. Straight White 11.25 x 2.1 x 1.5 ACEGHL STRIKER 7 750 330 Lighted 1 6 ft. Straight White 11.25 x 2.1 x 1.5 ACEGHIL TLP604TEL 6 870 330 1 in/1 out Lighted 1 4 ft. Straight White 10.5 x 1.6 x 1.25 ACGL TLP604 6 720 330 Unlit 4 ft. Straight White 10.5 x 1.6 x 1.25 ACGL TLP602 6 250 330 Unlit 2 ft. Straight White 9.5 x 1.5 x 1.5 ACHI TRAVELER 2 1050 330 1 in/1 out None 2 Retractable Black 3.5 x 1.75 x 2.5 ACHI
(A)
All outlets are NEMA 5-15R. All 8 and 10 outlet models include outlets with sliding safety covers. suppression). Models with 1 LED: Protected (indicates presence of sufficient surge suppression). electrical rating and include EMI/RFI line noise filtering. to change without notice.
TRAVELER100BT
2 1050 330 1 in/1 out
(D)
RJ45 jacks protect either Tel/Modem or Ethernet line, but not both lines simultaneously. The policy of Tripp Lite is one of continuous improvement. Specifications are subject
(D)
(B)
Models with 2 LEDs: Grounded (indicates presence of proper outlet grounding); Protected (indicates presence of sufficient surge
(C)
All plugs are NEMA 5-15P. All models feature 14/3 SJT cord types. All models are rated to 120V AC, 50/60 Hz. with an 1800W (15A)
Keyhole Slots Keyhole slots on the bottom of all models (except rack mount) provide secure mounting.
METAL HOUSING MODEL MOUNTING CENTERS
ISOBAR8ULTRA / ISOTEL8ULTRA, ISOBAR25ULTRA = 8.3125 in.; ISOBAR6ULTRA / ISOTEL6ULTRA / ISOBAR6ULTRAHG = 6.8125 in.; ISOBAR4ULTRA / ISOTEL4ULTRA = 5.25 in.; DG115-SI / DG206 / SPS-615-HG = 8 in. (Note: PM6SN1 and PM6NS do not feature keyhole mounting slots.)
PLASTIC HOUSING MODEL MOUNTING CENTERS
TLP1008TELTV / TLP1008TEL = 3.375 in.; TLP810NET / TLP810SAT / TLP808TELTV / TLP808TEL / TLP808 / SUPER7TEL15 / SUPER7TEL / SUPER7COAX / SUPER7 / SUPER6TEL12 / SUPER6TEL = 3.4375 in.; TLP604 / TLP604TEL / TLP602 = 4.5 in.; STRIKER / TLP712 = 5.625 in. (Note: TRAVELER, TRAVELER100BT and TLP707TEL do not feature keyhole mounting slots.)
(F)
Protection Switch LEDs
1 in/1 out
Measure, mark and drive
screws along straight line.
(B)
Alarm Length Style
(D)
None 2 Retractable Black 3.5 x 1.75 x 2.5
(C)
Color L x W x D (in)
AC Outlet Circuit Tester
• Instantly detects faulty wiring in standard 3-wire, 120V AC wall outlets
• Easy-to-read display signals open ground, neutral or hot; and hot/ground or
Slide keyhole slots over
screw heads.
hot/neutral reversals
Model: CT120
5
MEDICAL-GRADE PRODUCTS
Tripp Lite Medical-Grade Products Facilitate UL 60601-1 Compliance
Why is UL 60601-1 important?
The safety of patients and staff depends on it. UL 60601-1 is a shock­prevention measure specified by NEC (National Electrical Code) requirements, covering all electronic devices in patient-care areas. Tripp Lite's Medical-Grade products are tested and certified for full UL 60601-1 compliance.
Can you meet UL 60601-1 standards and stay under budget?
Tripp Lite Medical-Grade products provide UL 60601-1 compliance for all connected devices, allowing you to continue using your existing hardware. Compared to upgrading site wiring and replacing equipment, that's a major savings!
Medical-Grade UPS Systems
Application: provide battery backup and surge/noise protection for computers and equipment in patient-care areas
• UL 60601-1 & 1778 listed
• Internal isolation transformer limits cumulative current leakage
• Reliable, long-lasting battery backup
• Automatic Voltage Regulation (AVR) and surge/noise protection
• Communication port(s) and PowerAlert
SMART1200XLHG
Model # (VA/Watts) Runtime
OMNISMART350HG 330/225 18/46 4 10.75 x 5.25 x 7.5 25 SMART700HG 700/450 18/42 4 12.75 x 7.5 x 9.5 44.2 SMART1200XLHG 1000/750 16/34+ 4 12.75 x 7.5 x 9.25 46.4
(A)
All models include one RS-232 (DB9) communication port. SMART700HG and SMART1200XLHG also include one USB port. PowerAlert included with SMART1200XLHG; available as a FREE download for other models. runtime varies with load, battery condition and other factors. SMART1200XLHG runtime is expandable with external battery packs (model BP36V27, sold separately). NEMA 5-15P HG plug.
Capacity Full/Half Load Dimensions Weight
Data-Saving Software
(B)
(min) Outlets
(C)
All models include NEMA 5-15R HG outlets and 6 ft. cord with
(A)
(C)
H x W x D (in) (lb)
(B)
Medical-Grade Isolation Transformers
Application: provide full line isolation and surge/noise protection for computers and equipment in patient-care areas
• UL 60601-1 & 1012 listed
• Faraday shield limits cumulative current leakage to <100 µA
• Surge/noise protection
IS1800HG
Model # (Watts) Outlets
IS250HG 250 2 4.5 x 4.75 x 7.75 13.2 IS500HG 500 4 5.75 x 6.25 x 9.25 22.2 IS1000HG 1000 4 7.25 x 7.25 x 10 36.8 IS1800HG 1800 6 7.75 x 8.25 x 12.25 54
(A)
IS1800HG includes NEMA 5-15/20R HG outlets. Other models include NEMA 5-15R HG outlets. IS1800HG's 6 ft. cord
includes a NEMA 5-20P HG plug. Other models include a 6 ft. cord with NEMA 5-15P HG plug.
Capacity Dimensions Weight
Life Support Statement: Use of this equipment in life support
applications where failure of this equipment can reasonably be
expected to cause the failure of the life support equipment or to
significantly affect its safety or effectiveness is not recommended.
Do not use this equipment in the presence of a flammable anesthetic
mixture with air, oxygen or nitrous oxide.
All Tripp Lite Healthcare Power Solutions are rated for 120V electrical service
and include Hospital-Grade plugs and outlets. The policy of Tripp Lite is one
6
of continuous improvement. Specifications are subject to change without notice.
(A)
H x W x D (in) (lb)
Estimated
Medical-Grade Mobile Power Retrofit Kit – NEW!
Application: provide battery backup and surge/noise protection for computers and equipment on mobile carts in patient-care areas
• UL 60601-1 and 1778 listed
HCRK
• Adds reliable, long-lasting AC power to non-powered medical carts
• Mounting hardware supports installation with the most popular carts
• Built-in USB port and Included PowerAlert Data-Saving Software
Model # (VA/Watts) (hr) Outlets
HCRK 350/300 Up to 12 3 Power Supply: Power Supply:
(A)
Estimated runtime in standard configuration. Runtime varies with load, battery condition and other factors. Additional runtime
solutions available (contact Tripp Lite).
Capacity Runtime
(B)
NEMA 5-15R HG outlets and coiled 10 ft. cord with NEMA 5-15P HG plug.
• Internal isolation transformer limits cumulative current leakage
(A)
Dimensions Weight
(B)
H x W x D (in) (lb)
3.5 x 11.5 x 6 14.4
Battery Module: Battery Module:
7 x 14.5 x 8.5 61.5
Medical-Grade Power Strip – NEW!
Application: provide convenient outlets in patient-care areas
• UL 60601-1 and 60950-1 listed
• Integrated outlet safety covers
• Site wiring fault protection
PS-415-HGULTRA
Model # Outlets
PS-415-HGULTRA 3 15 1.5 x 13.75 x 2.5
(A)
Wiring fault protection resets automatically. Patent pending. Also includes 15A circuit breaker.
NEMA 5-15R HG outlets and NEMA 5-15P HG plug.
• Accidental shutoff protection
(C)
Cord Length (ft) Dimensions H x W x D (in)
(A)
(B)
(B)
Switchless design.
PRODUCTS WITH HOSPITAL-GRADE
PLUGS & RECEPTACLES
Hospital-Grade Power Strips
Application: provide convenient hospital-grade outlets
• UL 1363 listed
• Accidental shutoff protection
PS-606-HG
Model # Outlets PS-415-HG 4 15 1.5 x 8.65 x 2.5 PS-602-HG 6 1.5 1.5 x 13.75 x 2.5 PS-606-HG 6 6 1.5 x 13.75 x 2.5 PS-615-HG 6 15 1.5 x 13.75 x 2.5 RS-1215-HG 12 15 1.75 x 19
(A)
All models are switchless, except RS-1215-HG, which includes illuminated switch with protective cover.
include NEMA 5-15R HG outlets and NEMA 5-15P HG plug. Not for use where NEC requires hospital-grade receptacles.
(C)
Designed for standard 19-inch racks. Unit without mounting hardware is 17.5 inches.
(B)
Cord Length (ft) Dimensions H x W x D (in)
(A)
(C)
x 4
(B)
All models
Hospital-Grade Surge Suppressors
Application: provide convenient hospital­grade outlets with surge protection
• UL 1449 & 1363 listed
ISOBAR6ULTRAHG
Model Outlets SPS-615-HG 6 450 15 1.5 x 13.75 x 2.5 ISOBAR6ULTRAHG 6 600 15 2.5 x 7 x 3.5
(A)
SPS-615-HG is switchless; ISOBAR6ULTRAHG includes illuminated switch with protective cover. NEMA 5-15R HG outlets and NEMA 5-15P HG plug. Not for use where NEC requires hospital-grade receptacles. ISOBAR6ULTRAHG includes exclusive isolated filter banks.
• Accidental shutoff protection
(B)
Joule Rating Cord Length (ft) Dimensions H x W x D (in)
(A)
(B)
All models include
(C)
UPS SYSTEMS & POWER DISTRIBUTION UNITS
All Tripp Lite UPS systems provide reliable battery backup to support equipment during blackouts and other power failures. All models also include line noise filtering and network-grade surge suppression to protect equipment against everything from catastrophic hardware damage to irreparable data corruption. Most models include communication ports and support automatic unattended shutdown of connected computers during extended blackouts. For more information about Tripp Lite UPS systems, request our full-color UPS brochure or go to www.tripplite.com.
BEST PROTECTION AVAILABLE
SmartOnline
• True on-line operation with continuous AC-to-DC-to-AC conversion isolates equipment from all power problems
• Pure sine wave power and zero transfer time to battery enables maximum compatibility and equipment stability
• Capacities from 750VA to 10kVA (600W to 8kW); 3-phase models from 20-30kVA (16-24kW)
• 2U to 10U total rack size with versatile rack/tower cabinets; tower models also available
• Extended runtime options available
Model shown: SU2200RTXL2Ua
UPS Systems
Application: protect and support mission-critical servers, network hardware and other equipment
INTERMEDIATE PROTECTION
Digital, AVR & OmniSmart
Application: protect and support computers, workstations, peripherals, A/V components and other equipment
• Automatic voltage regulation protects against brownouts and other voltage problems
• Capacities from 300VA to 1500VA (180W to 980W)
• Tower and low-profile desktop cabinets
Model shown: SMART1000LCD
UPS Systems
ADVANCED PROTECTION
SmartPro
• Advanced automatic voltage regulation protects against brownouts and other voltage problems
• Most models offer pure sine wave power
• Capacities from 500VA to 5kVA (300W to 4kW)
• 1U to 6U total rack size with versatile rack/tower cabinets; tower models also available
• Extended runtime options available
Model shown: SMART1500RMXL2Ua
®
UPS Systems
Application: protect and support servers, workstations, network hardware and other equipment
BASIC PROTECTION
Internet Office
®
& BC Series UPS Systems
Application: protect and support SOHO computers, peripherals and other office equipment
• Reliable battery backup and surge protection
• Capacities from 300VA to 1400VA (150W to 940W)
• Tower and low-profile desktop cabinets
Model shown: INTERNET750U
POWER DISTRIBUTION UNITS (PDUs)
Application: distribute power to rackmount and other equipment in IT and industrial environments
Standard PDUs Model # 1U Amps Plug Outlets PDU1215 Y 15A 5-15P 13 (5-15R) PDU1220 Y 20A 5-20P 13 (5-15/20R) PDU1220T Y 20A L5-20P 13 (5-15/20R)
• 1U rack (select models), 0U rack (vertical) or surface (wall, counter, workbench) installation
• Metal enclosures and 10-15 ft. cords
• Metered PDUs include digital load meters that display the current drawn by connected equipment (in amps)
Model shown: PDUMH15
PDU2430 Y 30A L5-30P 24 (5-15R) PDU1230 Y 30A L6-30P 2 (C19), 16 (C13) PDU1415 N 15A 5-15P 14 (5-15R) PDU1420T N 20A L5-20P 14 (5-15/20R) PDU40TDUAL N 2 x 20A 2 x L5-20P PDUNV Y 16A Multiple PDU12IEC Y 16A C20 inlet 12 (C13), 2 (C19)
PDUs are rated for 120V input/output, except PDU1230 (200-240V), PDUNV and PDU12IEC (100-240V).
(B)
Includes L5-20P to 5-20P adapter(s).
monitored and controlled via Ethernet. "AT" models are upgradeable to "ATNET" models.
LINE CONDITIONERS
Application: protect equipment in manufacturing and other industrial environments
• 89-147V input voltage regulated to 120V output
• EMI/RFI line noise filtration and surge suppression
Model Shown: LC1800
Model # Format Capacity (Watts) Outlets LS606M Tower 600 6 5.5 x 4.75 x 4.75 3.8
LC1200 Tower 1200 4 6.75 x 5.75 x 6.75 8 LC1800 Tower 1800 6 6.75 x 5.75 x 6.75 9.6 LC2400 Tower 2400 6 6.75 x 5.75 x 6.75 11.2 LS604WM Wallmount 600 4 4 x 5 x 5.75 8.3 LC1200WM Wallmount 1200 4 5 x 5 x 7.25 10 LCR2400 Rackmount 1200 14 5.25 x 19 x 7.75 18.2
All models are rated to 120V AC, 60 Hz. output. NEMA 5-15/20R outlets. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
Output Dimensions
(A)
All outlets are NEMA 5-15R except LC2400 which includes two
ORDERING:Contact Tripp Lite to order through a distributor near you: (773) 869-1234 • www.tripplite.com
(A)
H x W x D (in) Weight (lb)
(A, B)
40 (5-15/20R)
(C)
12 (C13), 2 (C19)
(C)
Includes C14, 5-15P, 5-20P, L5-20P and L6-20P plugs.
PRECISION-REGULATED DC POWER SUPPLIES
PR7: Our most popular model!
Model # Amps (ICS/Continuous) Dimensions H x W x D (in) Weight (lb) PR3UL 4.5/3 4.25 x 3 x 7.5 4 PR4.5 4.5/3 3.25 x 3 x 8.25 5 PR7 7/5 3.75 x 6.5 x 7.5 7 PR10 10/7.5 4.5 x 6.75 x 7.75 10 PR15 15/12 4.5 x 6 x 10 13 PR25 25/20 6.75 x 6.25 x 10.25 19 PR40 40/32 6.75 x 10.5 x 11.5 27
All models are rated to 120V AC, 60 Hz. input and 13.8V DC (± .5V) output. Additional models with ICS ratings from 3 to 60 amps are available.
PDUs with Digital Load Meters Model # 1U Amps Plug Outlets PDUMH15 Y 15A 5-15P 13 (5-15R) PDUMV15 N 15A 5-15P 16 (5-15R) PDUMV20 N 20A L5-20P PDUMV40 N 2 x 20A 2 x L5-20P PDUMH15AT Y 15A 5-15P 8 (5-15R) PDUMH20AT Y 20A 2 x L5-20P PDUMH15ATNET Y 15A 5-15P 8 (5-15R) PDUMH20ATNET Y 20A 2 x L5-20P
(D)
Includes redundant inputs with automatic transfer switch. "ATNET" models can be
Application: power test benches, 2-way radios, ham radios and point-of-sale displays
• Regulated output and overvoltage protection
• Quality filtering and current-limiting feature
(A)
20 (5-15/20R)
(B, D)
32 (5-15/20R)
(B, D)
16 (5-15/20R)
(B, D)
16 (5-15/20R)
(A)
Dual independent power circuits with dual cords, plugs and circuit breakers.
7
DC-to-AC EMERGENCY BACKUP/STANDBY POWER
Automatic Switchover Inverter/Chargers
E
Application: run 120V AC sump pumps, emergency lighting and security systems during extended power failures
• Provide medium- to long-term support by converting DC battery power to AC power, ensuring continuous facility safety and security
• Deliver PEAK SURGE output (up to 200% of continuous rating) to handle both equipment start-up and the fluctuating demands of motor-driven devices
• Accept user-supplied batteries for unlimited runtime
• Recharge batteries and run equipment when power is present
• Automatically switch to battery power during blackouts
• Clean, quiet operation—superior to gas generators
Input Watts Out Watts Out OverPower™ Peak Surge Watts Out DoubleBoost™ Peak Surge Outlet Dimensions Shipping
Model # (DC/AC) APS750 12V/120V, 60Hz 750 1125 1500 2 7 x 8.75 x 9 19
APS1250 12V/120V, 60Hz 1250 1875 2500 2 7 x 8.75 x 9 32 APS2012 12V/120V, 60Hz 2000 3000 4000 Hardwire 7.25 x 8.5 x 16.25 36 APS2424 24V/120V, 60Hz 2400 3600 4800 Hardwire 7.25 x 8.5 x 16.25 43 APS2448UL 48V/120V, 60Hz 2400 3600 4800 Hardwire 7.25 x 8.5 x 16.25 44 APS3636VR 36V/120V, 60Hz 3600 5400 7200 Hardwire 7.25 x 8.5 x 16.25 62 APSRM4 Remote Control LED/Switch Module and 50 ft. cord for all APS models 1 x 4 x 1.5 0.5 98-121 12V DC, 75 Amp Hour Sealed, Maintenance-Free Battery 9 x 10.25 x 7 58 BP260 Battery Case with Cables. Holds Two 98-121 Batteries 10.5 x 10.5 x 17.75 15
(A)
Charger capacities: APS750 (20A); APS1250 (30A); APS2012 (100/25A, selectable); APS2424 (55/14A, selectable); APS2448UL (15A); APS3636VR (30A). when batteries are properly charged. Actual output wattage levels and durations for OverPower and DoubleBoost Peak Surge Output varies depending on battery age, battery charge level and ambient temperature. APS1250 outlets are NEMA 5-15R.
(A)
Continuous
(B)
(150% of Cont. up to 1 hr.)
(B)
(200% of Cont. up to 10 sec.)
APS1250
A
C
(B)
Quantity
(B)
Maximum output power (Continuous or Peak Surge) only available
D
(C)
H x W x D (in) Weight (lb)
(C)
APS750 and
I
H
G
F
DC-to-AC MOBILE POWER
Compact/Lightweight Inverters
Application: run 120V AC power tools, lighting, test equipment and computers used in mobile environments
• Provide mobile power support by converting DC vehicle battery power to 120V, 60Hz AC power
G
• Deliver PEAK SURGE output (up to 200% of continuous rating) INSTANTANEOUSLY to handle equipment start-up
D
B
• Easy connection: lighter plug (PV150, PV375) or user-supplied cables (all other models)
• Clean, quiet operation—superior to gas generators
Watts Watts Out
Model # (DC) uous Portable Models PV150 12V 150 300 1 1.75 x 3.75 x 5.75 2 PV375 12V 375 600 2 2 x 4.25 x 7 3 PV700 12V 700 1400 3 2.75 x 5 x 8.25 3.5 Permanent-Mount Models PV1000HF 12V 1000 2000 4 4.25 x 6 x 13 7 PV1800HF 12V 1800 3600 4 4 x 6 x 15 8 PV3000HF 12V 3000 6000 4 4.5 x 11 x 14 16 APSRM4 Remote Control LED/Switch Module and cord 1 x 3.9 x 2.1 2.5
(A)
Actual output wattage levels and durations for Peak Surge Output varies depending on battery age, battery charge level and ambient temperature. includes two NEMA 5-15R and two NEMA 5-15/20R outlets.
Input Contin- (Instanta- Outlet H x W x D Weight
for PV1000HF and PV1800HF. Included FREE with PV3000HF.
Maximum output power (Continuous or Peak Surge) only available when batteries are properly charged.
FEATURES: High-Impact Polycarbonate Housing Heavy-Duty Metal Housing Keyhole or Flange Mount DC Input
E F G H
LEDs AC Input
I J
Remote Control Jack External Fuse
The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice. All trademarks are the sole property of their respective owners.
Out Peak Surge Dimensions Shipping
(A)
(A)
neous)
(B)
All models include NEMA 5-15R outlets except PV3000HF which
Quantity
(B)
(in) (lb)
A B C D
(Cord or Hardwired) AC Outlets Circuit Breakers (All Inverter/Chargers, Heavy-Duty Inverters and PV3000HF)
(PV150 and PV375).
J
PV375
Heavy-Duty Inverters
Application: run heavy-duty 120V AC power tools, lighting, test equipment and computers used in mobile environments
• Provide mobile power support by converting DC vehicle battery power to 120V, 60Hz AC power
• Deliver PEAK SURGE output (up to 200% of continuous rating) to handle both equipment start-up and the fluctuating demands of motor-driven devices
• Easy connection and mounting with user-supplied cables and hardware
• Clean, quiet operation—superior to gas generators
Watts Out Watts Out
OverPower™ DoubleBoost™
Watts Peak Surge Peak Surge Ship-
Out (150% of (200% of Outlet Dimensions ping
Model # (DC) uous PV750FC 12V 750 1125 1500 2 7 x 8.75 x 9 18 PV1250FC 12V 1250 1875 2500 2 7 x 8.75 x 9 25 PV2000FC 12V 2000 3000 4000 2 7.3 x 8.5 x 16.5 41 PV2400FC 24V 2400 3600 4800 2 7.3 x 8.5 x 16.5 44 APSRM4 Remote Control LED/Switch Module and 50 ft. 1 x 3.9 x 2.1 2.5
(A)
Actual output wattage levels and durations for OverPower and DoubleBoost Peak Surge Output varies depending on battery age, battery charge level and ambient temperature. are NEMA 5-15R. PV2000FC and PV2400FC outlets are NEMA 5-15/20R.
Input Contin- Cont. up to Cont. up to Quan- H x W x D Weight
Maximum output power (Continuous or Peak Surge) only available when batteries are properly charged.
(A)
1 hr.)
cord for all PV models in this chart.
Visit www.tripplite.com for complete specifications
on more than 1,000 quality products.
A
PV2400FC
D
C
(A)
10 sec.)
(A)
(B)
tity
(B)
PV750FC and PV1250FC outlets
(in) (lb)
8
5
YEARS
E
I
H
G
Distributed By:
1111 W. 35th Street, Chicago, IL 60609 • (773) 869-1234 • www.tripplite.com