Tripp Lite TLP808TELTV, TLP810NET Users Manual

Owner’s Manual
1111 W. 35th Street Chicago, IL 60609 USA
Customer Support: (773) 869-1234 • www.tripplite.com
Installation
2
FCC Part 68 Notice
3
Lifetime Limited Warranty
3
4
Protect It!
Surge Suppressors
Español
4
Copyright © 2007. All rights reserved. Protect It!
is a trademark of Tripp Lite.
Warranty Registration
4
WARRANTY
REGISTRATION:
register online today for a chance
to win a FREE Tripp Lite product—
www.tripplite.com/warranty
Français
7
Important Safety Instructions
1
CUS
U
L
SAVE THESE INSTRUCTIONS
CAUTION! DO NOT connect to an ungrounded outlet. DO NOT use with 2-wire
extension cords or adapters.This surge suppressor is designed for indoor use only. Install the surge suppressor away from heat-emitting appliances such as radiators or heat registers. Do not install where excessive moisture is present. Do not plug extension cords into it. Never install electrical, telephone, network or coaxial wiring during a lightning storm. Do not drill into any part of the housing or open the housing for any reason. There are no user-serviceable parts inside.
Important Safety Instructions
2
Installation
Mount Your Surge Suppressor (Optional Installation. Available on Select Models Only):
If desired, mount your surge suppressor on a wall or other sturdy, vertical surface. However, you must mount the surge suppressor prior to connecting your equipment. Place a sheet of paper over the surge suppressor’s mounting holes and mark their centers with a push pin. Next, place this template over the desired area and mark with the push pins. Install screws (user supplied) into the marks until ¼ in. (0.6 cm) of the screw heads are exposed. Mount the surge suppressor over the screw heads and slide into place.
Connect Your Surge Suppressor to the AC Power Line: Plug the surge suppressor’s power cord into a standard, 3-wire grounded 120V AC outlet.
Turn Your Surge Suppressor ON: Press the surge suppressor’s power switch to “ON” or “RESET” (depending on model). Select models feature an illuminated switch.
Check Your Surge Suppressor’s Diagnostic Indicator Lights (Available on Select Models Only): If your surge suppressor features diagnostic LEDs, check them prior to connecting your
equipment. They will indicate various operating conditions when the surge suppressor is plugged into a live 120V AC outlet and the surge suppressor’s power switch is on.
“PROTECTED” LED: Indicates the surge suppression components are intact and providing complete protection against surges. If this LED does not illuminate, some of the surge suppression components are not functioning, and the unit should be replaced. Call Tripp Lite Customer Support at (773) 869-1234.
“GROUNDED” LED: Indicates wall outlet is grounded and surge protection can properly function. If this light DOES NOT illuminate and power is present, consult a qualified electrician to examine your outlet’s wiring.
“LINE OK” LED (select models): Indicates 120V AC power is present with no wiring faults detected.
Connect Your Equipment to the Surge Suppressor’s AC Outlets: Plug your equipment’s power cords (including 2-wire devices) into the surge suppressor’s AC outlets. Select models feature integrated safety covers which cover the outlets when not in use. Other models feature special widely-spaced outlets to accommodate transformers without covering other outlets. DO NOT plug in extension cords. DO NOT OVERLOAD the surge suppressor’s outlets. The surge suppressor can accommodate a total equipment load of up to 15 amps (whether plugged into a single outlet or spread out over multiple outlets). If the load on the surge suppressor exceeds 15 amps, the circuit breaker* will trip and the outlets will stop providing power. If the circuit breaker trips, reduce the load by unplugging some devices. Depress the circuit breaker to reset.
* Circuit breakers are integrated into the power switch on select models and offered as a separate feature on other models.
Connect Your Equipment to the Surge Suppressor’s Phone Jacks (Optional Installation. Available on Select Models Only): Connect a phone cable from the wall jack directly to the
surge suppressor’s RJ-style phone jack labeled “IN.” Connect a phone cable from the surge suppressor’s RJ-style phone jack labeled “OUT” directly to the device to be protected. Select models feature two “OUT” jacks; either one or both of the jacks may be used, but protection is for a device or devices sharing a single line only. All models with phone line surge protection, except the TLP810NET, protect devices on a single line only. TLP810NET models feature a single set of RJ-style phone jacks which protect devices on two lines. The surge suppressor must always be the first item connected in line from the wall jack. The surge suppressor must be plugged into a 3-wire, grounded AC outlet for phone line surge protection to work.
Connect Your Equipment to the Surge Suppressor’s Network Jacks* (Optional Installation. Available on Select Models Only): Connect a data cord from the wall jack or
cable/DSL modem directly to the surge suppressor’s network jack labeled “IN.” Connect a data
* 10/100 BaseT/TX, Token Ring. Not compatible with PoE (Power Over Ethernet) applications.
3
Installation
(continued)
cord from the surge suppressor’s network jack labeled “OUT” directly to the device to be protected (typically a computer’s network interface card). The surge suppressor must always be the first item connected in line from the Ethernet source (typically a wall jack). The surge suppressor must be plugged into a 3-wire grounded AC outlet for network line surge protection to work.
Connect Your Equipment to the Surge Suppressor’s Coaxial Jacks (Optional Installation. Available on Select Models Only): Connect a coaxial cable from the wall jack directly to the
surge suppressor’s “F” style coaxial jack labeled “IN.” Connect a coaxial cable from the surge suppressor’s “F” style coaxial jack labeled “OUT” directly to the device to be protected. Select models include a second set of coaxial jacks for simultaneous connection and protection of devices on two separate lines (cable, antenna or satellite). The surge suppressor must always be the first item connected in line from the coaxial wall jack. The surge suppressor must be plugged into a 3-wire grounded AC outlet for coaxial line surge protection to work.
If your Modem/Fax Protection causes harm to the telephone network, the telephone company may temporarily discontinue your service. If possible, they will notify you in advance. If advance notice isn't practical, you will be notified as soon as possible. You will be advised of your right to file a complaint with the FCC. Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect the proper operation of your equipment. If it does, you will be given advance notice to give you an opportunity to maintain uninterrupted service. If you experience trouble with this equipment's Modem/Fax Protection, please call Tripp Lite Technical Support at (773) 869-1234 for repair/warranty information. The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure the equipment is not malfunctioning. There are no repairs that can be made by the customer to the Modem/Fax Protection. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. (Contact your state public utility commission or corporation commission for information.)
Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and workmanship for its lifetime. If the product should prove defective in material or workmanship within that period, Seller will repair or replace the product, in its sole discretion. Service under this Warranty can only be obtained by your delivering or shipping the product (with all shipping or delivery charges prepaid) to: Tripp Lite, 1111 W. 35th St., Chicago, IL 60609. Seller will pay return shipping charges.
The warranties of all TRIPP LITE surge suppressors are null and void if they have been connected to the output of any UPS system. The warranties of all TRIPP LITE UPS Systems are null and void if a surge suppressor has been connected to its output receptacles.
THIS WARRANTY DOES NOTAPPLY TO NORMALWEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. (Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from jurisdiction to jurisdiction.)
WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application.
The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to the series number. The series number should not be confused with the marking name or model number of the product.
FCC Part 68 Notice
(United States Only)
Lifetime Limited Warranty
Loading...
+ 5 hidden pages