SmartOnline SV Series 60kVA Medium-Frame Modular Scalable 3-Phase On-Line Double­Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Modules
MODEL NUMBER: SV60KM3P0B
3-phase 60kVA UPS system offers network-grade power protection in a highly configurable, modular and scalable medium-chassis rack-width frame. External batteries required to operate.
Description
Highlights
Scalable capacity up to 80kVA (or 60kVA with N+1 fault tolerance)
Economy mode option helps reduce operating and cooling costs
Pre-installed WEBCARDLX network interface for 24/7 remote access
DSP/IGBT technology and 1% output voltage regulation
External batteries required to operate
Package Includes
SV60KM3P0B SmartOnline SV Series 60kVA 3-Phase On-Line Double-Conversion UPS System Pre-installed WEBCARDLX network interface (3) SV20PM 20kVA power modules (shipped separately) Owner’s manual
The SV60KM3P0B includes pre-installed input, bypass and output breakers, as well as a static transfer switch (STS) and three 20kVA SV20PM power modules. Space is included for one additional user­installable SV20PM power module. External ±120VDC battery options, such as BP240V370 or EBP240VXXX series battery cabinets, are available from Tripp Lite for extended runtime.
The Java-free HTML5-based WEBCARDLX interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network.
With up to 92% efficiency in standard mode and up to 99% efficiency in optional economy mode, this 60kVA UPS system helps you reduce operating and cooling costs. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. Front­panel display offers full UPS condition and status reporting.
Features
60kVA 54kW 3-Phase Medium-Chassis UPS SystemSupports 208/120V or 220/127V AC 50/60Hz Wye
4-wire plus Earth hardwire input and output wiringDual hardwire input design enables operation from up to 2 power sourcesNetwork-grade sine-wave AC output with 1% output voltage regulation and less than 1% output total harmonic distortionTested to UL 1778 (U.S.), CSA (Canada) and NOM (Mexico) standardsHigh 0.9 power factor for maximum power to the connected load Pre-Installed WEBCARDLX Network InterfaceAllows full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSHSupports 10/100 Mbps auto-sensing for communication with an Ethernet networkOptional EnviroSense2 sensors (sold separately) enable site monitoring of temperature, humidity and contact-closure statusNo Java
1 / 6
required Modular, Scalable Design for Maximum FlexibilityModular configuration with hot-swappable power modules and batteries enables easy, fast maintenance with zero downtimeOpen slot for 1 additional 20kVA SV20PM power module accommodates increased capacity up to 80kVA (or 60kVA with N+1 fault tolerance)Supports external ±120VDC battery options for extended runtimes Optional Economy ModeUp to 99% efficient in optional economy mode to lower operating and cooling costs Wide Input/Narrow Output Voltage Operating RangeEnables full continuous online operation during brownouts as low as 121V and overvoltages up to 253VRegulates output voltage within 1% of the selected nominal output voltage in on-line double-conversion mode Advanced IGBT Inverter with Digital Signal Processor (DSP) TechnologyProvides for less than 2% input total harmonic distortion (THDi) to support 1:1 generator sizing and prevent the need to oversize generator systems relative to UPS capacity Automatic and Manual Bypass OptionsKeep connected equipment operational during routine maintenance or critical power module failure
Specifications
OVERVIEW
UPC Code 037332237477 UPS Type On-Line
INPUT
Rated input current (Maximum Load) SV60KM3P0B 60kVA Configuration: 180A; Maximum 80kVA Configuration: 240A; 306A maximum inrush current Nominal Input Voltage(s) Supported 120/208V 3-PH Wye; 127/220V 3-PH Wye Nominal Input Voltage Description Set of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, G) inputs from two separate power
UPS Input Connection Type Hardwire Input Circuit Breakers MAIN and ALTERNATE AC inputs are each protected by 300A 3 pole magnetic breakers Input Phase 3-Phase Input Frequency 40 to 70Hz (online mode); 50/60Hz Auto-selectable Power Factor (Input) Greater than 0.99 (full load) THDi Less than 2% (full linear load)
OUTPUT
Output Volt Amp Capacity (VA) 60000 Output kVA Capacity (kVA) 60 Output Watt Capacity (Watts) 54000 Output kW Capacity (kW) 54 Output Capacity Details OVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1
Power Factor 0.9
sources
minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less
Crest Factor 3:1
2 / 6