Tripp Lite SRFC5STR48, SRFC5STR72, SRFC10STR48, SRFC10STR72 Installation Manual

Installation Guide
Straight Channel Section for
Fiber Routing System
Models: SRFC5STR48, SRFC5STR72, SRFC10STR48, SRFC10STR72
Español 5 • Français 9 • Русский 13
WARRANTY REGISTRATION
tripplite.com/warranty
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2020 Tripp Lite. All rights reserved.
1
Parts List
Straight Channel Section, x1
Models and Dimensions
Before proceeding with installation, first confirm your model and dimensions.
Model Cross-Sectional View Height Interior Width Length
SRFC5STR48
SRFC5STR72
SRFC10STR48
SRFC10STR72
4.6 in.
(118 mm)
4.6 in.
(118 mm)
4.6 in.
(118 mm)
4.6 in.
(118 mm)
4.8 in.
(120 mm)
4.8 in.
(120 mm)
9.5 in.
(241 mm)
9.5 in.
(241 mm)
48 in.
(1219 mm)
72 in.
(1829 mm)
48 in.
(1219 mm)
72 in.
(1829 mm)
2
Additional Accessories
All accessories are sold separately.
Accessory Model Number
5 in. (120 mm) System 10 in. (240 mm) System
SRFC5CPL5 SRFC10CPL10 Coupler Kit to Connect Channels and Fittings
SRFC5RAMP SRFC10RAMP Up/Down Ramp to Change Level of a Horizontal Run
SRFC5ELBOW SRFC10ELBOW 90-Degree Fitting to Create Elbow in a Horizontal Run
SRFC5JUNT SRFC10JUNT T-Shaped Fitting to Create 90-Degree Branch from a Straight Run
SRFC5JUNT4 SRFC10JUNT4 4-Way Cross Fitting to Create a Junction with 2 Horizontal Exits
Accessory Description and Function
SRFC5DROP SRFC10DROP
SRFC4WTRFL
SRFC4WTRFL36
SRFC4WTRFL48
SRFC5CAP SRFC10CAP
SRFC5CPL10
Trumpet Drop-Out Kit to Limit Bend Radius at an Exit from a Channel, Horizontal T or Vertical T
Movable Waterfall Adapter to Enable Cable to Cascade over the Side at a Horizontal Exit
Movable Waterfall Adapter with Pipe to Enable Cable to Cascade over the Side into 36 in. Corrugated Plastic Pipe at a Horizontal Exit
Movable Waterfall Adapter with Pipe to Enable Cable to Cascade over the Side into 48 in. Corrugated Plastic Pipe at a Horizontal Exit
End Cap Kit to Close off the End of a Channel for a Professional, Finished Look
Adapter to Combine 5 in. (120 mm) Components with 10 in. (240 mm) Components
3
Installation
Straight channel sections carry fiber cables horizontally through the system. Connect to additional straight channel sections or other fittings using SRFC5CPL5 or SRFC10CPL10 couplers, sold separately. Tighten screws and nuts by hand, no tools necessary.
1
Coupler kit
sold separately
2
1
1
2
2
Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Photos and illustrations may differ slightly from actual products.
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
4
20-01-081 93-3BD8_revA
Guía de Instalación
Sección de Canal Recto para
Sistema de Conducción de Fibra
Modelos: SRFC5STR48, SRFC5STR72, SRFC10STR48, SRFC10STR72
English 1 • Français 9 • Русский 13
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2020 Tripp Lite. Todos los derechos reservados.
5
Loading...
+ 11 hidden pages