Tripp Lite's SMART 2200NET intelligent, line interactive large tower UPS system protects servers, networking
accessories and telecommunications equipment from blackouts, voltage fluctuations and transient surges. Large
internal batteries offer 27 minutes half load runtime and 11 minutes fully loaded. Runtime is expandable with optional BP24V28-2U(limit 1) and BP24V70-3U
external battery packs. 2200VA/1700 watt power handling capability supports a variety of networking, telecom and other sensitive electronic applications.
Includes 6 protected outlets. Supports remote monitoring of UPS and site power conditions via built-in RS-232 enabled monitoring port, plus standard UPS
monitoring via 2 built in contact closure ports. Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling. Built-in audible
alarm and front panel LEDs indicate line power, battery power, battery charge level, load level, plus voltage regulation status. Network grade AC surge
suppression protects equipment from damage and performance problems resulting from transient surges.
Features
SMART 2200NET line interactive UPS offers battery derived AC output during power outages, voltage regulation during brownouts and overvoltages, plus
network-grade AC surge suppression
2200VA/1700 watt power handling capability supports a variety of networking, telecom and other sensitive electronic devices
Large internal batteries offer runtimes of 27 minutes at half load(1100VA/850 watts) and 11 minutes at full load(2200VA/1700 watts)
Runtime is further expandable with optional external BP24V28-2U(limit 1) and BP24V70-3U(multi-pack compatible) battery packs
Intelligent battery management system extends battery life
Automatic Voltage Regulation(AVR) circuits maintain 120V nominal output over an input voltage range of 87-140V
Includes 6 fully protected NEMA 5-15R outlets with 2 single outlet load banks that can be individually powered off and back on again via software interface
PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, email notification, event logging and
running user defined script commands
Offers simultaneous monitoring of up to 3 directly connected devices through included DB9 contact closure and RS-232 enabled interfaces, or the
monitoring of any number of additional servers over IP with included PowerAlert monitoring software
In addition to the contact closure monitoring of on battery, low battery and power restored messaging, built-in RS-232 interface supports messaging of
UPS and line power status, including AC line voltage, DC battery voltage and remaining battery capacity
Supports activate self-test and UPS output power control for delayed or immediate reboot of connected equipment
Output Capacity Details1200W max output with 1-2 external battery packs; 800W max output with 3 or more external battery packs
Power Factor0.8
Nominal Output Voltage(s)
Supported
Nominal Voltage Details120v nominal output in battery mode
Frequency Compatibility60 Hz
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles(6) 5-15R
Load Management ReceptaclesTwo switchable single outlet 5-15R load banks
Output AC Waveform (AC Mode)Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
INPUT
Rated input current (Maximum Load)15A
Nominal Input Voltage(s) Supported120V AC
UPS Input Connection Type5-15P
Input Circuit Breakers20A
UPS Input Cord Length (ft.)8
110V; 115V; 120V
-13% / +5%
+/- 5%
UPS Input Cord Length (m)2.4
Recommended Electrical Service20A 120V
Input Cord Length (ft.)8
Input Cord Length (m)2.4
Input PhaseSingle-Phase
BATTERY
Full Load Runtime (min.)11 min. (1700w)
Half Load Runtime (min.)27 min. (850w)
Expandable Battery RuntimeExtended runtime supported via optional external battery packs
External Battery Pack Compatibility
DC System Voltage (VDC)24
Battery Recharge Rate (Included
Batteries)
Expandable RuntimeYes
VOLTAGE REGULATION
Voltage Regulation DescriptionAutomatic voltage regulation (AVR) maintains line power operation with an input voltage range of 87 to 140
Overvoltage CorrectionInput voltages between 127 and 140 are reduced by 12%
Undervoltage CorrectionInput voltages between 95 and 105 are boosted by 10%
Severe Undervoltage CorrectionInput voltages between 87 and 94 are boosted by 22%
USER INTERFACE, ALERTS & CONTROLS
Switches
Alarm Cancel Operation
Audible AlarmAudible alarm indicates power-failure and low-battery conditions
LED Indicators5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
BP24V28-2U
Less than 9 hours from 10% to 90% (typical, full load discharge)
2 Switches control off/on power status and alarm-cancel/self-test operation; set of 4 rear-panel switches control
system enable and contact closure port inverter shutoff commands
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status
(limit 1);
BP24V70-3U
(multi-pack compatible)
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating720
UPS AC Suppression Response
Time
EMI / RFI AC Noise SuppressionYes
PHYSICAL
Primary Form FactorTower
UPS Power Module Dimensions
(hwd, in.)
UPS Power Module Dimensions
(hwd, cm)
UPS Power Module Weight (lbs.)80
UPS Power Module Weight (kg)36.3
UPS Shipping Dimensions (hwd / in.) 22.2 x 12.8 x 16.5
UPS Shipping Dimensions (hwd /
cm)
Instantaneous
17 x 9 x 12.5
43.2 x 22.9 x 31.8
56.5 x 32.4 x 41.9
Shipping Weight (lbs.)87
Shipping Weight (kg)39.5
UPS Housing MaterialPolycarbonate
ENVIRONMENTAL
Operating Temperature Range+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius