Tripp Lite S3M40KXD User Manual

SmartOnline S3MX Series 3-Phase 380/400/415V 40kVA 36kW On-Line Double-Conversion UPS, Parallel for Capacity and Redundancy, Single & Dual AC Input
MODEL NUMBER: S3M40KXD
Highlights
Best-in-class footprint and power density minimize space requirements for up to 40kVA
Intuitive LCD interface offers key performance, configuration and diagnostics info
High efficiency (94% on-line, 98% ECO mode) helps reduce operating costs
Add optional WEBCARDLX with latest version of PADM20 for enhanced remote management
Parallel for capacity and redundancy up to 3 units
Single and dual AC input capability
Highly efficient 94% on-line UPS with compact design protects mission-critical equipment against downtime due to power disturbances.
Features
supports the continuous availability of your most important loads through all power conditions, providing a compact backup power platform that’s easy to manage and inexpensive to operate. Sophisticated voltage and frequency independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 40kVA of clean, continuous power, this 3-phase UPS system is perfect for critical applications in IT, communications, corporate, commercial, retail, financial, security, transportation, emergency and edge infrastructure environments. Best-in-Class Footprint for Easy Integration into Your Network ApplicationThis on-line double­conversion UPS system has a very small footprint of just 0.24 square meters. It requires less valuable space in your facility, and you can install the UPS system in spaces that would previously have required expensive retrofitting. Efficient Operation and Design Reduces Cost of OwnershipThis UPS benefits from highly efficient transformer-free double-conversion technology that delivers operating cost savings. It achieves 94% efficiency in double-conversion mode and up to 98% in ECO mode, reducing your power and cooling costs. A low THDi (<3%) improves generator compatibility. A low THDv (2%) and active power factor correction improve output performance. The hardware and firmware platform design reduces the number of unique boards, improving mean time to repair (MTTR) and resulting in reduced downtime. Built-in static and maintenance bypass transfer UPS load to utility power during faults, overloads and maintenance, which also avoids costly system downtime. Supplies Reliable Battery Backup with Expandable Runtime OptionsInternal 10Ah batteries provide 15 minutes of support at half load and five minutes at full load with zero transfer time. Adding external battery cabinets, such as BP480V10 (sold separately), provides extended runtime. The S3M40KX automatically restarts after a lengthy power outage. Intuitive LCD Interface Delivers Important Performance Information at a GlanceThe interactive front­panel LCD interface displays critical operating conditions and diagnostic data, including operating mode, input/output voltage, load, battery voltage, backup runtime and fault conditions. Four LEDs provide information about line, bypass, battery and fault status. Network Management Card Offers Remote Monitoring and ControlThe optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for
Applications
Save space in tight data center environments with best-in-class small footprint
Back up essential equipment in network, telecom, financial and edge infrastructure applications
Maintain critical server-room operations during all power conditions, including short blackouts
Package Includes
S3M40KXD SmartOnline S3MX Series 3-Phase 380/400/415V 40kVA 36kW On-Line Double­Conversion UPS
RS-232 cable
Paralleling cable kit
Owner’s manual
1 / 5
expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. Parallel Capability Provides Additional CapacityConnect up to three S3M40KXD units in parallel using separate/shared battery cabinets for increased capacity or for redundancy. 2-Year Warranty Provides Peace of MindThe S3M40KXD is backed by a 2-year warranty, ensuring reliability and performance.
Specifications
OVERVIEW
UPC Code 037332239761 UPS Type On-Line
INPUT
Rated input current (Maximum Load) 61A Nominal Input Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye Nominal Input Voltage Description 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G) UPS Input Connection Type Hardwire Input Circuit Breakers 80A (3 pole) Input Phase 3-Phase Power Factor (Input) .99PF (100% load) THDi <3% (100% load)
OUTPUT
Output Volt Amp Capacity (VA) 40000 Output kVA Capacity (kVA) 40.00 Output Watt Capacity (Watts) 36000 Output kW Capacity (kW) 36.00 Output Capacity Details Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to
Power Factor 0.9 Crest Factor 3:1 Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details Automatic frequency selection Output Voltage Regulation (Line
Mode) Output Voltage Regulation
(Economy Line Mode)
130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to less than 70%; Configuration options support up to 3 S3M30KX systems wired in parallel for increased capacity or fault-tolerant, redundant operation
+/- 1%
+/-11V of nominal
2 / 5
Output Voltage Regulation (Battery Mode)
+/- 1%
Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery
Mode) Nominal Output Voltage(s)
Supported
Pure Sine wave
220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
Output Receptacles Hardwire Individually Controllable Load Banks No
BATTERY
Full Load Runtime (min.) 5 min. (36kW) Half Load Runtime (min.) 14 min. (18kW) Expandable Battery Runtime Supports extended runtime with optional external battery packs Expandable Runtime Yes External Battery Pack Compatibility  <a class="productLink" href="//www.tripplite.com/external-ups-battery-pack-80-10-Ah-
battery~BP480V10">BP480V10</a>  DC System Voltage (VDC) +/- 240 Battery Recharge Rate (Included
Batteries)
9 hours to 90% (Internal batteries)
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online
mode
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation
and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input /
output voltage & frequency, estimated runtime and more (see user manual for a detailed listing) Switches ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON:
turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test
operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm
and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for
1 second to enter or exit the settings menu (See user manual for detailed information) Audible Alarm Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY
MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second),
OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except
OVERLOAD & OTHER WARNINGS conditions LED Indicators 4 LEDs report BYPASS / LINE / BATTERY / FAULT modes
PHYSICAL
Cooling Method Fans Installation Form Factors Supported
with Included Accessories
Tower
Primary Form Factor Tower
3 / 5
Primary UPS Depth (mm) 815 Primary UPS Height (mm) 1,000 Primary UPS Width (mm) 300 Shipping Dimensions (hwd / in.) 47.44 x 16.90 x 36.22 Shipping Weight (kg) 321.60 UPS Housing Material Steel UPS Power Module Dimensions
(Height x Width x Depth, mm) UPS Power Module Dimensions
(hwd, in.)
1000 x 300 x 815
39.37 x 11.81 x 32.08
UPS Power Module Weight (kg) 315.70 UPS Power Module Weight (lbs.) 696
ENVIRONMENTAL
Operating Temperature Range 0 to +40C (32-104F) Storage Temperature Range 0 to +35C (32 to 95F) with battery; -15 to 60C (5 to +140F) without battery Relative Humidity 5 to 95%, non-condensing Operating Elevation (ft.) < 3280ft (Capacity de-rates by 1% for every 328ft over 3280ft ) Audible Noise <60dBA at 1meter Operating Elevation (m) < 1000m (Capacity de-rates by 1% for every 100m over 1000m)
COMMUNICATIONS
Network Management Cards  <a class="productLink" href="//www.tripplite.com/Web-Management-Accessory-
Card~WEBCARDLX">WEBCARDLX</a> ;  <a class="productLink"
href="//www.tripplite.com/Programmable-RS-485-Management-Accessory-Card-for-Select-3-Phase-UPS-
Systems~MODBUSCARDSV">MODBUSCARDSV</a> ;  <a class="productLink"
href="//www.tripplite.com/Programmable-Relay-I-O-Card-Tripp-Lite-SVTX-SVX-SV-UPS-
Systems~RELAYCARDSV">RELAYCARDSV</a>  Network Monitoring Port Description Card accessory slot supports network management interface or programmable I/O relay card options Communications Cable DB9/RS-232 cable included Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
LINE / BATTERY TRANSFER
Transfer Time Zero transfer time Online to Battery, Inverter to Bypass 0ms (Synchronous), and Inverter to ECO mode < 10ms. Low Voltage Transfer to Battery
Power (Setpoint) High Voltage Transfer to Battery
Power (Setpoint)
120V (Ph-N), 208V (Ph-Ph) @50% load / 176V (Ph-N), 305V (Ph-Ph) @100% load
276V (Ph-N), 478V (Ph-Ph) @ 50% or 100% load.
SPECIAL FEATURES
Grounding Lug Yes
4 / 5
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
High Availability UPS Features Automatic inverter bypass; Manual bypass switch; Auto Probe Monitoring (requires WEBCARDLX); Zero transfer
Green Energy-Saving Features High efficiency economy mode operation
STANDARDS & COMPLIANCE
UPS Certifications CE Certification Details IEC/EN 62040-1:2008+A1 (Safety); IEC/EN 62040-2:2006 (Category C3)
WARRANTY
Product Warranty Period (U.S. & Canada)
Product Warranty Period (International)
Product Warranty Period (Mexico) 2-year limited warranty Product Warranty Period (Puerto
Rico) 3-Phase Warranty Statement Tripp Lite 3-Phase UPS Factory Warranty
time; On-Line/Double-Conversion
2-year limited warranty
2-year limited warranty
2-year limited warranty
© 2021 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies: https://www.tripplite.com/products/product-certification-agencies
5 / 5