SmartOnline S3MX Series 3-Phase 380/400/415V

160kVA 144kW On-Line Double-Conversion UPS

MODEL NUMBER: S3M160KX

Highly efficient 94% on-line UPS with compact design protects mission-critical equipment against downtime due to power disturbances.

Features

Battery Backup and VFI Operation Protect Critical LoadsThe SmartOnline® S3M160KX IGBT UPS supports the continuous availability of your most important loads through all power conditions, providing a compact backup power platform that’s easy to manage and inexpensive to operate. Sophisticated voltage and frequency independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 160kVA of clean, continuous power, this 3-phase

UPS system is perfect for critical applications in IT, communications, corporate, commercial, retail, financial, security, transportation, emergency and light industrial environments.

Best-in-Class Footprint for Easy Integration into Your Network ApplicationThis on-line doubleconversion UPS system has a very small footprint of just 0.56 square meters. It requires less valuable space in your data center, and you can install the UPS system in spaces that would previously have required expensive retrofitting.

Efficient Operation and Design Reduces Cost of OwnershipThis IGBT UPS benefits from highly efficient transformer-free double-conversion technology that delivers operating cost savings. It achieves 94% efficiency in double-conversion mode and up to 98% in ECO mode, reducing your power and cooling costs. A low THDi (<3%) improves generator compatibility. A low THDv (2%) and active power factor correction improve output performance. The hardware and firmware platform design reduces the number of unique boards, improving mean time to repair (MTTR) and resulting in reduced downtime. Built-in static and maintenance bypass transfer UPS load to utility power during faults, overloads and maintenance, which also avoids costly system downtime.

External Batteries Supply Reliable Backup with Expandable Runtime OptionsThe S3M160KX uses external scalable battery cabinets, such as BP480V65 and BP480V100 (sold separately), to provide up to three hours of backup support in case of a power failure. Add the optional TEMPC100200 thermostat kit to enable temperature-compensated charging for optimized battery lifespan. The UPS system automatically restarts after a lengthy power outage.

Intuitive Color Touchscreen Display Delivers Important Performance Information at a GlanceThe large (25.4 cm/10 inches) front-panel color interface enables comprehensive local monitoring and control capability. It displays critical operating conditions and diagnostic data, such as phase load levels, available runtime, alarm status, battery charge, and voltage and frequency values. Six LEDs indicate bypass, online, inverter, battery and alarm/fault modes.

Network Management Card Offers Remote Monitoring and ControlThe optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. Auto Probe allows a UPS with switched loads to automatically reboot

Highlights

Best-in-class footprint and power density minimize space requirements for up to 160kVA

Large (25.4 cm/10 in.) color touchscreen display enables user-friendly local management

High efficiency (94% on-line, 98% ECO mode) helps reduce operating costs

Optional WEBCARDLX with latest version of PADM20 supports Auto Probe feature

Parallel capability provides increased capacity and fault tolerance

Applications

Fit 160kVA UPS in best-in-class footprint to save space for revenue-generating equipment

Back up critical IT equipment and data in network, telecom, financial and light industrial applications

Maintain data-center operations during all power conditions

Package Includes

S3M160KX SmartOnline S3MX Series 3-Phase 380/400/415V 160kVA 144kW On-Line Double-Conversion UPS

P100200KIT parallel cable kit

RS-232 cable

Owner’s manual

1 / 5

devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.

Parallel Capability Provides Additional CapacityConnect two S3M160KX units in parallel using separate/shared battery cabinets for increased capacity and fault tolerance (N+1 redundancy).

Specifications

OVERVIEW

UPC Code

037332225443

 

 

UPS Type

On-Line

 

 

INPUT

 

Rated input current (Maximum Load)

275A

 

 

Nominal Input Voltage(s) Supported

220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye

 

 

Nominal Input Voltage Description

3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G)

 

 

UPS Input Connection Type

Hardwire

 

 

Input Circuit Breakers

400A (3 pole)

 

 

Input Phase

3-Phase

 

 

Power Factor (Input)

.99PF (100% load)

 

 

THDi

<3% (100% load)

 

 

OUTPUT

 

Output Volt Amp Capacity (VA)

160000

 

 

Output kVA Capacity (kVA)

160.00

 

 

Output Watt Capacity (Watts)

144000

 

 

Output kW Capacity (kW)

144.00

 

 

Output Capacity Details

Supports up to 100% load continuously in double conversion mode; Supports up to 110% load for 60 minutes, up to

 

to 125% load for 10 minutes, up to 150% load for 1min and greater than 150% for 1 milliseconds before switching to

 

bypass mode; Inverter mode is automatically restored as load levels are reduced to less than 100%; Configuration

 

options support up to 2 S3M160KX systems wired in parallel for increased capacity, or redundancy (N+1) to increase

 

fault-tolerant and redundant operation

 

 

Power Factor

0,9

 

 

Crest Factor

3:1

 

 

Frequency Compatibility

50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion

 

 

Frequency Compatibility Details

Automatic frequency selection

 

 

Output Voltage Regulation (Line

+/- 1%

Mode)

 

 

 

Output Voltage Regulation

+/-15V of nominal

(Economy Line Mode)

 

 

 

Output Voltage Regulation (Battery

+/- 1%

Mode)

 

 

 