OmniSmart 120V 330VA 225W UL 60601-1 Medical
Highlights
330VA line interactive tower UPS
Maintains sine-wave 120V
nominal output over an input
range of 83 to 132V
Professional features include
serial port, hospital grade plug &
outlets, built-in isolation
transformer and UL60601-1 listing
Input: Hospital-grade NEMA
5-15P (120V 15A) / Output: 4
Hospital-grade NEMA 5-15R
(120V)
2 line phone suppression for
TEL/DSL line protection
Leakage current less than 100
microamps
Package Includes
OMNI SMART 350HG Hospital
Grade UPS System
Serial cable for remote monitoring
Warranty information
Instruction manual
Grade Line-Interactive UPS, Tower, DB9 Serial
MODEL NUMBER: OMNISMART350HG
Description
Tripp Lite's OMNI SMART 350HG offers medical-grade UPS protection with built-in line interactive voltage
regulation, intelligent monitoring and unattended shutdown capability. Hospital-grade plug & outlets, plus built-in
isolation transformer with Faraday shield offers full isolation and removes common mode noise equal to 100
microamps. UL 60601-1 listed as medical electrical equipment. 330VA power handling capacity supports
computers, inter-networking equipment and other critical loads during commercial power failures. Line interactive
voltage regulation corrects brownouts as low as 83V back to normal 120V levels, saving battery reserves for use only during complete power failures. Includes,
2 line phone surge suppression and built-in DB-9 communications port that works with PowerAlert Software and cabling to provide automatic unattended
shutdown of connected network and PC applications.
Features
Ideal UPS protection for applications in medical patient-care areas where UL 60601-1 listed electrical medical equipment is required
Line-interactive voltage regulation corrects brownouts as low as 83V without using battery power
Hospital-grade plug and outlets offer added degree of safety and reliability to input/output connections
Full line isolation prevents shock potential and operational problems in sensitive electronic equipment
Resistant to electrostatic discharge
Supports loads up to 330VA/225 watts
46 minutes half load runtime (with 165VA load), 18 minutes full load runtime (with 330VA load)
4 protected hospital-grade outlets; 6-ft. cord
1-DB9 serial port for network interface
Complete surge protection, line isolation and EMI/RFI noise filtering
2 phone line surge suppression for modems, fax machines and other phone accessories
Complete remote monitoring cabling included, PowerAlert UPS management software available via free download
4 diagnostic LEDs indicate AC present, on battery, voltage correction & battery low/replace
Battery replacement door and back panel grounding lug
Specifications
OUTPUT
Output Volt Amp Capacity (VA) 330
Output Watt Capacity (Watts) 225
Nominal Output Voltage(s)
Supported
Frequency Compatibility 60 Hz
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles (4) 5-15R
Output Receptacle Details Hospital grade output receptacles
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
INPUT
Rated input current (Maximum Load) 2.3A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type 5-15P-HG
Input Circuit Breakers 3.5A
UPS Input Cord Length (ft.) 6
UPS Input Cord Length (m) 1.8
120V
-18%, +8%
+/- 5%
Recommended Electrical Service 15A 120V
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 18 min. (225w)
Half Load Runtime (min.) 46 min. (115w)
DC System Voltage (VDC) 12
Battery Recharge Rate (Included
Batteries)
Internal UPS Replacement Battery
Cartridge
Battery Access Battery access door
Battery Replacement Description Hot-swappable, user replaceable batteries
Less than 4.5 hours from 10% to 90%
(quantity 2)
RBC52