Tripp Lite OMNI500ISO User Manual

Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA
Customer Support: (773) 869-1234 • www.tripplite.com
Important Safety Instructions
2
Quick Installation
3
Basic Operation
4
7
Warranty Registration
8
OMNISMART
Full Isolation UPS Systems
• Full Isolation (Less than 300µA Leakage)
• Line-Interactive Operation
• 120V Input
Not suitable for mobile applications.
Copyright ©2006 Tripp Lite. All rights reserved. OmniSmartis a trademark of Tripp Lite.
Warranty
Registration:
register online today for a chance
to win a FREE Tripp Lite product—
www.tripplite.com/warranty
Español
9
Français
18
Important Safety Instructions
2
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.
• For best performance, keep the indoor temperature between between 32º F and 104º F (0º C and 40º C).
• Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
• Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself; this will damage the UPS.
• Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s ground connection.
• Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be voided if anything other than Tripp Lite surge suppressors are used to connect your UPS to an outlet.
• If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output.
Equipment Connection Warnings
• Do not use Tripp Lite UPS Systems for life-support appliances in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life-support device.
• Do not connect surge suppressors or extension cords to the output of your UPS. This may damage the UPS and will void the surge suppressor and UPS warranties.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your UPS for any reason. There are no user-serviceable parts inside.
• Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the UPS before performing battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery replacement should be performed only by authorized service personnel using the same number and type of batteries (Sealed Lead-Acid). The batteries are recyclable. Refer to your local codes for disposal requirements or in the USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-822-8837) or visit www.rbrc.com for recycling information. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at www.tripplite.com/support/battery/index.cfm to locate the specific replacement battery for your UPS.
• Do not attempt to add external batteries.
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty.
3
Quick Installation
Connect your UPS to an electrical outlet.
Your UPS will run a self-test after it is plugged in. See Basic Operation to understand the results of its self-test.
Plug your computer, monitor and other equipment into the UPS system.
Your UPS is designed to support only com­puter equipment. You will overload your UPS if you connect high power draw equipment such as household appliances or laser printers to outlets providing UPS battery backup. Select models feature special outlets (clearly labeled on the rear panel) which provide surge-only (not battery backup) protection designed for laser printers and other heavy­draw devices.
Select UPS Operating Mode.*
Press the ON/OFF button to toggle your UPS between the UPS (“ ” LED lit) and the CHARGE ONLY (“ ” LED flashing) modes. Choose the operating mode based on your location:
USA, Canada & Western Europe:
• Leave the UPS in the UPS mode at all times. All other countries:
• Put the UPS in the CHARGE ONLY mode when you are not
using connected
equipment.
(WARNING! When set to “CHARGE ONLY,” the UPS will not provide battery backup during a blackout or brownout)
• Put the UPS in the UPS mode when you are
using connected equipment.
*See Basic Operation section for a complete explanation of each mode.
3
2
1
1
2
3
Model Shown: OMNI500ISO