Highlights
12V DC or 120VAC input; 120V AC output; 2 NEMA 5-15R hospital-grade
outlets
1250 watts continuous, 1875 watts OverPower™ and 2500 watts
DoubleBoost™ inverter output
3 stage, 14/55 amp selectable wet/dry cell battery charger
Auto Transfer Switching option for battery backup / UPS operation - includes
wired APSRM4 remote control switch
Tested to vehicular inverter standards UL458 (USA) and CSA-C22.2 No.
107.1-01 (Canada). Meets GSA Ambulance Specification KKK-A-1822
Hospital-grade AC plug and GFCI outlets; Anderson quick connect DC wiring
terminals
Description
Tripp Lite's EMS1250UL inverter with integrated charging system provides automatic, uninterruptible DC-to-AC power for critical on-board
equipment. Ideal for installation by ambulance/EMS vehicle manufacturers, dealer or EMS service for OEM, replacements and upgrades. Supplies
up to 1250 watts of continuous 120V AC power to 2 AC outlets from any 12V battery or automotive DC source. When AC cable is connected to a
shore power source, commercial power passes through to connected equipment and the battery set is recharged via 3 stage, 14/55 amp selectable
charging system. This unit can also function as a UPS system, responding to blackouts and voltage fluctuations with a near instantaneous automatic
transfer to battery-derived AC output. Convenient Anderson DC input quick connector on the unit with extra Anderson DC input connector included in
the box (user supplies batteries and cabling). Reliable large transformer design with efficient PWM sine wave output and frequency control powers
resistive electronic loads or large inductive motors, compressors and other items with high current needs on startup. Included APSRM4 wired remote
power switch with full status LEDs provides remote power inverter on/off switching and continuous status information (APSRM4 included). Supports
an unlimited amount of runtime with any number of user-supplied batteries connected. Highly adaptable to a variety of applications and site
conditions with adjustable charger settings for wet/gel battery types and selectable line to battery power transfer voltages. Includes AC input surge
suppression. Includes hospital grade plug and outlets with GFI (ground fault interrupter) protection. TUV tested to UL458 (mobile inverter) and
CAN/CSA-C22.2 No. 107.1-01. Meets GSA ambulance specification KKK-A-1822.
Applications
Versatile inverter/charger system with auto-transfer switching serves as an automotive inverter for EMS applications (ambulance,
emergency or police vehicles); a standalone alternative power source for backup power operation and as an uninterruptible power supply
(UPS) for items compatible with a 16.6 millisecond transfer time.
Package Includes
EMS1250UL Inverter/Charger
Instruction manual with warranty information
Wired Remote Switch with full LED status indicators (model APSRM4)
2 Anderson DC connectors (1 on the unit and 1 included in the box)
Features
EMS1250UL serves as an automotive or stationary DC-to-AC inverter with automatic line-to-battery transfer and integrated battery charger
Supports 120V AC output from a 120V AC line power source or 12V DC battery source
16.6 millisecond automatic transfer between line and battery power supports UPS protection during blackouts and voltage fluctuations for
equipment compatible with a one cycle transfer time
1250 watts continuous AC output in inverter mode, 1440 watts continuous AC output in AC mode
Double Boost™ inverter output supports momentary startup loads up to 200% of the continuous rating for up to 10 seconds
OverPower™ inverter output supports longer duration overloads to 150% for 1-60 minutes under ideal battery and temperature conditions.
(For best results, utilize OverPower usage for as short of a duration as possible, ensure battery bank and cabling is able to provide full
nominal DC voltage under load and allow inverter/charger to fully cool before and after OverPower usage.)
3 stage, selectable 14/55 amp battery charger with adjustable settings for wet/gel battery types offers fast, reliable battery recharging
Anderson quick connect DC wiring terminals safely accept input from attached battery bank
Protected hardwire output passes 120V line power or inverter output through to connected equipment
Reliability enhanced large-transformer design tested to UL (USA) and CSA (Canada) standards
Moisture-resistant construction enables vehicular or marine operation in high humidity environments
3 position operating mode switch supports "AUTO" mode to enable automatic transfer between DC and AC modes, CHARGE-ONLY to
maintain a full battery charge when AC is present without auto transfer and SYSTEM OFF settings
Set of six front panel LEDs display AC/DC operational modes, overload status, DC voltage level, shutdown status and system fault status
Set of 4 configuration dipswitches support wet/gel battery charging profiles, adjustable 135/145V high voltage auto transfer during
overvoltages and selectable 75/85/95/105V AC low voltage auto transfer during brownouts
Set of 4 additional configuration dipswitches support 4 levels of charger limiting relative to output load size, a battery equalization program
and battery charger low/high/off settings
Resettable 12A charger AC input breaker and resettable 12A AC output breaker and automatic 2 speed cooling fan protect the inverter from
load and temperature related failures
Grounding lug properly connects the inverter/charger system to earth ground or vehicle grounding system
Automatic overload and thermal shutoff safely turns off inverter as excessive loads or overheating conditions develop
Front panel remote control connector enables remote off/on switching (APSRM4 remote control switch with status LED display and 50 ft
cable included). APSRM4 accessory also includes user configurable jacks to support inverter shutoff or startup as a vehicle ignition is
engaged
Load sensing control dial enables adjustable load threshold required to automatically turn the inverter on and off in DC mode as load
conditions change
Specifications
OVERVIEW
Intended Application EMS/Ambulance
SYSTEM OVERVIEW
Voltage compatibility 12VDC / 120VAC
Frequency compatibility
60 Hz
OUTPUT
Output watts 1250W (continuous) / 2500W (peak)
Output nominal voltage
120V
Output voltage regulation
LINE POWER (AC): Maintains 120V nominal sine wave output from line power source. INVERTER POWER (AC): Maintains PWM sine wave output voltage of 120 V AC (+/-5%).
Output frequency regulation
60 Hz (+/- 0.3 Hz)
Outlet quantity / type 2 AC outlets
Outlet details 2 Hospital-Grade GFCI duplex outlets
Overload protection Includes 12A input breaker dedicated to the charging system and 12A output breaker for AC output loads
Continuous output capacity (watts)
1250
Peak output capacity (watts)
2500
INPUT