• Charge up to 10 tablets, smartphones or other mobile devices
• Doubles as a USB or AC charger and storage unit, providing space to neatly
organize your devices as they charge
• Removable dividers customize the unit’s storage space according to the number
and size of devices being charged
CSD1006USB Model
• BC1.2 rapid charging with a single port is capable of providing up to 5V 2.4A
• Overcurrent protection prevents devices from pulling more power than the charger
is capable of supporting
• Overcharging protection stops charging when a device battery is full
CSD1006AC Model
• 2880-joule surge suppression rating
• EMI/RFI noise filtering
• Diagnostic LED indicates Protected (green) and Grounded (red)
• Automatic shutoff cuts power to outlets when the protection circuit has been
compromised
• $25,000 Ultimate Lifetime Insurance for connected equipment
(U.S., Canada, and Puerto Rico only)
Package Contents
CSD1006USB
• USB Charger
• External Power Supply with 5-15P
Plug (Input: 100V-240V, 50/60 Hz;
Max Output: 12V, 8A)
• Enclosure unit with locking lid
• USB charger enclosure mount
• Keys
• Combination cable lock
• Owner’s Manual
17-01-037-93362C-EN.indd 21/5/2017 5:07:12 PM
CSD1006AC
• 10-Outlet AC Surge Protector
• Enclosure unit with locking lid
• Keys
• Combination cable lock
• Owner’s Manual
2
Optional Accessories
• M100-Series USB to Lightning™ Cables
• M110-Series USB to Apple® 30-Pin Cables
Important Safety Warnings
• Always read the safety instructions carefully.
• Keep these instructions for future reference.
• Do not install near any heat sources such as radiators, heat registers, stoves, or
other equipment (including amplifiers) that produces heat.
• Unplug the unit when unused for extended periods of time.
• To reduce the risk of fire or electric shock, do not expose this unit to rain or
moisture, including any dripping or splashing.
• Objects filled with liquids, such as vases, should never be placed on or near the
unit.
• The unit presents an electric shock hazard; do not open.
• The outlet used to power the unit should be easily accessible and located near
the equipment.
• The power supply cord is for indoor use only.
•
Maximum ambient temperature around the adapter must not exceed 104°F (40°C).
• The power supply cord’s plug and inlet are used as the disconnect device for
the unit and its connected peripherals. The power supply cord should be easily
accessible during operation.
• Refer to the marking label on the unit for input and output ratings. Do not
overload the power supply.
• Use of this equipment in life support applications where failure of this equipment
can reasonably be expected to cause the failure of the life support equipment or
to significantly affect its safety or effectiveness is not recommended.
3
17-01-037-93362C-EN.indd 31/5/2017 5:07:12 PM
Setup
Both Models
1
After removing the protective packing, locate the separate box at the
rear of the enclosure unit containing the USB or AC charger. Remove the
USB charger or surge protector from its box.
2
Remove the enclosure lid by pushing out and lifting up.
4
17-01-037-93362C-EN.indd 41/5/2017 5:07:13 PM
Setup
3
Lift and remove the storage shelf from the enclosure.
4
Attach the charging unit to the enclosure:
CSD1006USB Model
Slide the included mounting bracket onto the enclosure’s rear slots.
A
5
17-01-037-93362C-EN.indd 51/5/2017 5:07:13 PM
Setup
CSD1006USB Model (continued)
Insert the USB charging unit into the mounting bracket with the USB ports
B
facing upward.
Connect USB charging cables appropriate for the number and type of
C
devices. The slots located at the top and front of the enclosure base allow for
convenient cable routing.
6
17-01-037-93362C-EN.indd 61/5/2017 5:07:13 PM
Setup
CSD1006USB Model (continued)
Once all desired USB cables are connected, place the storage shelf on top of
D
the enclosure base.
Note: To remove or adjust storage
shelf dividers, refer to pg. 11.
Connect the electronic devices to the USB power cables and place items inside
E
the shelf tray.
Use the included power supply to connect the charging unit to a Tripp Lite
F
surge protector or AC wall outlet.
Proceed to step 5.
G
7
17-01-037-93362C-EN.indd 71/5/2017 5:07:14 PM
Setup
CSD1006AC Model
Insert the AC surge protector into the enclosure’s rear slots. Make sure the AC
A
outlets are facing outward.
Connect the AC power cables appropriate for the number and type of
B
devices. The slots located at the top and front of the enclosure base allow for
convenient cable routing.
8
17-01-037-93362C-EN.indd 81/5/2017 5:07:14 PM
Setup
CSD1006AC Model (continued)
Once all desired AC power cables are connected, place the storage shelf on top
C
of the enclosure base.
Note: To remove or adjust storage
shelf dividers, refer to pg. 11.
Connect the electronic devices to the AC power cables and place items inside
D
the shelf tray.
Plug the charging unit into an AC wall outlet.
E
Proceed to step 5.
F
9
17-01-037-93362C-EN.indd 91/5/2017 5:07:15 PM
Setup
Both Models
To prevent device tampering and theft, reattach the enclosure lid to the
5
top of the enclosure. Use the included key to lock the barrel lock.
Secure the enclosure unit to a desk using the included combination
6
cable lock.
10
17-01-037-93362C-EN.indd 101/5/2017 5:07:15 PM
Adjusting Storage Shelf Dividers (All Models)
Remove the enclosure lid, then remove any personal electronic devices stored on
the shelf tray. Lift the shelf tray. Once the shelf is removed, push in the three tabs
securing the divider to the bottom of the tray A, then pull the divider upward to
disengage from the shelf tray B. Repeat as necessary for additional shelf dividers.
A
B
11
17-01-037-93362C-EN.indd 111/5/2017 5:07:15 PM
Specifications
CSD1006USB
Ports(x10) USB A Female
External Power Supply
USB OutputCapable of providing up to 5V 2.4A to a single port.
Operating Temperature41° to 95°F (5° to 35°C)
Storage Temperature-4° to 122°F (-20° to 50°C)
Relative Humidity20% to 80%
Regulatory ApprovalsCE, FCC, RoHS, REACH, WEEE
CSD1006AC
Outlets(x10) 5-15R
Input Connection TypeNEMA 5-15P Plug
Input Cord Length6 ft. (1.83 m)
AC Surge Suppression Rating 2880 joules
Operating Temperature41° to 95°F (5° to 35°C)
Storage Temperature-4° to 122°F (-20° to 50°C)
Relative Humidity20% to 80%
Regulatory ApprovalsUL1449 3rd Edition, RoHS
Input: 100-240V, 50/60 Hz; Max Output: 12V 8A
12
17-01-037-93362C-EN.indd 121/5/2017 5:07:15 PM
Product Registration
Visit www.tripplite.com/warranty today to register your new Tripp Lite product. You’ll be automatically
entered into a drawing for a chance to win a FREE Tripp Lite product!*
* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.
1-Year Limited Warranty (CSD1006USB Model)
TRIPP LITE warrants its products to be free from defects in materials and workmanship for a period
of one (1) year from the date of initial purchase. TRIPP LITE’s obligation under this warranty is limited
to repairing or replacing (at its sole option) any such defective products. To obtain service under
this warranty, you must obtain a Returned Material Authorization (RMA) number from TRIPP LITE or
an authorized TRIPP LITE service center. Products must be returned to TRIPP LITE or an authorized
TRIPP LITE service center with transportation charges prepaid and must be accompanied by a brief
description of the problem encountered and proof of date and place of purchase. This warranty does
not apply to equipment, which has been damaged by accident, negligence or misapplication or has
been altered or modified in any way.
EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid
limitation(s) or exclusion(s) may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT,
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT,
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, TRIPP LITE is not liable for any
costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software,
loss of data, costs of substitutes, claims by third parties, or otherwise.
13
17-01-037-93362C-EN.indd 131/5/2017 5:07:15 PM
Lifetime Limited Warranty (CSD1006AC Model)
Seller warrants this product, if used in accordance with all applicable instructions, to be free from
original defects in material and workmanship for its lifetime. If the product should prove defective
in material or workmanship within that period, Seller will repair or replace the product, in its sole
discretion. Service under this Warranty can only be obtained by your delivering or shipping the product
(with all shipping or delivery charges prepaid) to: Tripp Lite, 1111 W. 35th St., Chicago, IL 60609.
Seller will pay return shipping charges.
The warranties of all TRIPP LITE surge protectors are null and void if they have been connected to the
output of any UPS system. The warranties of all TRIPP LITE UPS Systems are null and void if a surge
protector has been connected to its output receptacles.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT,
MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE
WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE
LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS,
ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY
EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. (Some states do not allow
limitations on how long an implied warranty lasts, and some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitations or exclusions may not apply
to you. This Warranty gives you specific legal rights, and you may have other rights which vary from
jurisdiction to jurisdiction.)
WARNING: The individual user should take care to determine prior to use whether this device is
suitable, adequate or safe for the use intended. Since individual applications are subject to great
variation, the manufacturer makes no representation or warranty as to the suitability or fitness of these
devices for any specific application.
14
17-01-037-93362C-EN.indd 141/5/2017 5:07:15 PM
Ultimate Lifetime Insurance Policy
(CSD1006AC Model Only)
This is a limited warranty valid in the U.S., Canada and Puerto Rico only.
Tripp Lite warrants, for the lifetime of the product, (at Tripp Lite’s option) to repair or replace (on a pro
rata basis) directly connected equipment that is damaged due to power transients while properly connected to Tripp Lite products offering the Ultimate Lifetime Insurance Policy. Power transients include
spikes and surges on the AC power, data or telephone lines that the Tripp Lite products have been
designed to protect against (as recognized by industry standards). The following four paragraphs are
conditions that must be complied with before the warranty becomes valid; failure to comply with these
requirements will void the warranty.
AC Power Line Transients: To claim damages, the Tripp Lite product must be plugged into a properly
wired and grounded outlet. No extension cords or other electrical connections may be used. The
installation must comply with all applicable electrical and safety codes set forth by the National Electrical Code (NEC). Except as provided above, this warranty does not cover any damage to properly connected electronic equipment resulting from a cause other than an “AC power transient”. If user meets
all of the above requirements, Tripp Lite will repair or replace (at Tripp Lite’s option) equipment up to
the specified value (See Ultimate Lifetime Insurance Policy Limits). No coverage is allowed for damage
entering from telephone or data lines, unless they are separately protected, as described below.
Telephone and Data Line Transients: Tripp Lite will repair or replace directly connected equipment that
is damaged by transients on telephone and/or data lines only when all such paths are protected by a
Tripp Lite protection product(s) and the AC power (utility) line is simultaneously protected by a Tripp
Lite power protection device (UPS, surge suppressor or line conditioner) with Ultimate Lifetime Insurance coverage. Additional telephone and/or data line connected devices downstream must have their
own telephone and/or dataline protectors.
Reimbursement dollar limits will be equal to that of the Tripp Lite power protection protector. Coverage
is excluded where a suitable environment for the protection device is not provided, including, but not
limited to, lack of a proper safety ground. Telephone service equipment must also include a properly
installed and operating “primary protection” device at the telephone service entrance (such devices
are normally added during telephone line installation).
All above warranties are null and void if the Tripp Lite product has been improperly installed, tampered
with or altered in any way, or if the connected equipment was not used under normal operating conditions or in accordance with any labels or instructions. All claims under this warranty must be submitted
in writing to Tripp Lite within 30 days of the occurrence or the claim will not be considered. This warranty does not include damage resulting from accident or misuse, and applies to the domestic (USA &
Canada) use of these products only. Tripp Lite reserves the right to determine whether the damage to
the connected equipment is due to malfunction of the Tripp Lite product by requesting the equipment
in question be sent to Tripp Lite for examination. This policy is above and beyond, only to the extent
needed, of that provided by any coverage of connected equipment provided by other sources, including, but not limited to, any manufacturer’s warranty and/or any extended warranties.
EXCEPT AS PROVIDED ABOVE, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do
not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to purchaser. EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE
LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT
OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use
of equipment, loss of software, loss of data, costs of substitutes, claims by third parties or otherwise.
Coverage also does not apply to connected medical and industrial equipment.
To receive service under this warranty, you must be the original purchaser/user of the product in question. You must obtain a Returned Material Authorization (RMA) number from Tripp Lite. Products must
be returned to Tripp Lite with transportation charges prepaid and must be accompanied by a brief
description of the problem encountered and proof of date and place of purchase.
Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
15
17-01-037-93362C-EN.indd 151/5/2017 5:07:16 PM
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
16
17-01-037-93362C-EN.indd 161/5/2017 5:07:16 PM
17-01-037 93-362C_RevB
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.