Tripp Lite 93-2642 User Manual

Owner’s Manual
Quiet Mobile Power
Congratulations! You've purchased the most advanced, feature-rich Inverter/Charger designed for recreational applications. Tripp Lite MRV Inverter/Chargers are the quiet alternative to generators—with no fumes, fuel or noise to deal with! You get AC electricity anywhere and anytime you need it: away from shore power, rolling down the highway, dry camping in majestic back country or overnighting at a non-electric site. Your Tripp Lite Inverter/Charger provides your appliances, equipment and electronics with utility- or generator-supplied AC electricity (filtered through premium ISOBAR®surge protection) whenever available. In addition, it automatically powers your craft's 12V system and recharges your connected battery bank—doing what traditional converter/chargers do. Whenever power blackouts, brownouts or high voltages occur, your Inverter/Charger immediately and automatically switches over to inverting battery output to power connected AC equipment.
Better for Your Equipment Premium Protection Levels
• Built-In ISOBAR®Surge Protection
• Automatic Overload Protection
Ideal Output for All Loads
• Frequency-Controlled Output
• Automatic Load Switching
• Balanced Load Sharing
Better for Your Batteries Faster Battery Recharge
• High-Amp, 3-Stage Battery Charger (adjustable)
Critical Battery Protection
• Battery Charge Conserver (Load Sense)
• Battery Temperature Sensing
• High-Efficiency DC-to-AC Inversion
Better for You Quiet, Simple, Maintenance-Free Operation
• Multi-Function Lights & Switches
• Automatic Generator Starting
• Moisture-Resistant Construction*
Safety 2 Feature Identification 3 Operation 4-5 Configuration 5-7 Battery Selection 8 Mounting 9
Battery Connection 10 AC Input/Output Connection 11 Service/Maintenance 11 Troubleshooting 12 Warranty/Warranty Registration 12
Français 13
PowerVerter
®
MRV DC-to-AC
Inverter/Charger
Input Output
Invert: 12 VDC 120V, 60 Hz. AC Charge: 120V, 60 Hz. AC 12 VDC
1111 W. 35th Street, Chicago, IL 60609 USA
Customer Support: (773) 869-1234
www.tripplite.com
* Inverter/Chargers are moisture-resistant, not waterproof.
Copyright © 2007. All rights reserved. PowerVerter
®
is a registered trademark of Tripp Lite.
Contents
WARRANTY
REGISTRATION
Register online today for
a chance to win a FREE Tripp Lite
product! www.tripplite.com/warranty
2R
Important Safety Instructions
Caution: If your Inverter/Charger is mounted in a location that lack proper ventilation, the surface of the metal enclosure could become hot. Allow to cool before touching. If the Inverter/Charger must be installed in a location that lacks proper ventilation, mount the unit in such a way that the top of the metal enclosure will not be subjected to accidental contact during operation.
SAVE THESE INSTRUCTIONS!
This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite Inverter/Chargers.
Location Warnings
• Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might accumulate. Mounting should be in the driest location available.
• Leave a minimum of 2" clearance at front and back of the Inverter/Charger for proper ventilation. To avoid automatic Inverter/Charger shutdown due to overtemperature, any compartment that contains the Inverter/Charger must be properly ventilated with adequate outside air flow. The heavier the load of connected equipment, the more heat will be generated by the unit.
• Do not install the Inverter/Charger directly near magnetic storage media, as this may result in data corruption.
• Do not install near flammable materials, fuel or chemicals.
Battery Connection Warnings
• The Inverter/Charger will not operate (with or without utility power) until batteries are connected.
• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.
• Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be installed (whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some ventilation to outside air.
• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.
• Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury or property damage could result.
Equipment Connection Warnings
Do not use a Tripp Lite MRV Inverter/Charger in life support or healthcare applications where a malfunction or failure of a Tripp Lite MRV Inverter/Charger could cause failure of, or significantly alter the performance of, a life support device or medical equipment.
• You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of the Inverter/Charger.
• Tripp Lite recommends wiring the AC output to a GFCI protector (ground fault circuit interrupter).
• The main grounding lug should be connected to the vehicle chassis with an 8 AWG wire (minimum).
Operation Warnings
• Your Inverter/Charger does not require routine maintenance. Do not open the device for any reason. There are no user serviceable parts inside.
• Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply and/or AC input are connected. During any service work, the battery supply and AC input connection (if any) should therefore be disconnected.
• Do not connect or disconnect batteries while the Inverter/Charger is operating in either inverting or charging mode. Operating Mode Switch should be in the OFF position. Dangerous arcing may result.
Caution: Some models have a failsafe AC pass-through feature where the AC output will be live (if AC input is available) even though the operating mode switch is set to DC OFF.
3R
Feature Identification
Identify the premium features on your specific model and quickly locate instructions on how to maximize their use.
Configuration DIP Switches: optimize Inverter/Charger operation depending on your application. See Configuration section for setting instructions.
Operating Mode Switch: controls Inverter/Charger operation. The “AUTO/REMOTE” setting ensures your equipment receives constant, uninterrupted AC power. It also enables the Inverter/Charger to be remotely monitored and controlled with an optional remote module (Tripp Lite model APSRM4, sold separately). The “CHARGE ONLY” setting allows your batteries to return to full charge faster by turning the inverter off which halts battery discharging. See Operation section for setting instructions.*
“LINE”, “INVERT”, “LOAD” LEDs: intuitive “traffic light” signals show whether the Inverter/Charger is operating from AC line power or DC battery power. It also warns you if the connected equipment load is too high. See Operation section for instructions on reading the indicator lights.
"BATT VOLTAGE" LEDs: these three lights will turn ON in several sequences to show approximate battery level. See Operation section for instructions on reading the indicator lights.
DC Power Terminals: connect to your battery terminals. See Battery Connection section for instructions.
Hardwire AC Input/Output Terminals: securely connect the Inverter/Charger to vehicle or facility electrical system input and recommended GFCI protected output. See AC Input/Output Connection section for instructions.
Resettable Circuit Breaker: protect your Inverter/Charger against damage due to charger failure. See Operation section for resetting instructions.
Remote Control Module Connector: allows remote monitoring and control with an optional module (Tripp Lite model APSRM4, sold separately). See remote module owner’s manual for connection instructions.
Battery Charge Conserver (Load Sense) Dial: conserves battery power by setting the low-load level at which the Inverter/Charger’s inverter automatically shuts off. See Configuration section for setting instructions.
Main Ground Lug: properly grounds the Inverter/Charger to vehicle grounding system or to earth ground. See Configuration section for instructions.
Multi-Speed Cooling Fan: quiet, efficient fan prolongs equipment service life.
Hardwire AC Input/Output Cover Plate Battery Temperature Sensing Connector: prolongs battery life
by adjusting charge based on battery temperature. Use with cable (included on select models). See Configuration section for details.
Automatic Generator Start Connector: automatically cycles generator based on battery voltage. Use with user-supplied cable. See Configuration section for details.
Ignition Switch Control Jack: use to connect the Inverter to your vehicle's ignition switch (with user supplied cable) in order to automatically control the Inverter with the vehicle's ignition switch. See Operation section.
1
2
3
4
5
6
7
8
9
1
24 3
5
7
6
Front View
10
Rear View
Side Mounted, Not Shown
Side Mounted, Not Shown
10
11
12
13
11
8
9 13 14
12
14
* OFF - De-energizes unit and AC output on most models.
DC OFF - De-energizes unit and connects AC OUT to AC IN on select models.
15
Side Mounted, Not Shown
15
“FOR USE WITH COPPER WIRE ONLY”
HOT IN
NEUTRAL IN
GROUND IN
GROUND OUT
HOT OUT
NEUTRAL OUT
4R
Operation
Switch Modes
After configuring, mounting and connecting your Inverter/Charger, you are able to operate it by switching between the following operating modes as appropriate to your situation:
AUTO/REMOTE: Switch to this mode when you need constant, uninterrupted AC power for connected appliances and equipment. The Inverter/Charger will continue to supply AC power to connected equipment and to charge your connected batteries while utility­or generator-supplied AC power is present. Since the inverter is ON (but in Standby) in this mode, it will automatically switch to your battery system to supply AC power to connected equipment in the absence of a utility/generator source or in over/under voltage situations. “AUTO/REMOTE” also enables an optional remote control module (Tripp Lite model APSRM4, sold separately) to function when connected to the unit.
CHARGE ONLY: Switch to this mode when you are not using connected appliances and equipment in order to conserve battery power by disabling the inverter. The Inverter/Charger will continue to supply AC power to connected equipment and charge connected batteries while utility- or generator-supplied AC power is present. However, since the inverter is OFF in this mode, it WILL NOT supply AC power to connected equipment in the absence of a utility/generator source or in over/under voltage situations.
OFF (most models): Switch to this mode to shut down the Inverter/Charger completely, preventing the inverter from drawing power from the batteries, and preventing utility AC from passing through to connected equipment or charging the batteries. Use this switch to automatically reset the unit if it shuts down due to overload or overheating. First remove the excessive load or allow the unit to sufficiently cool (applicable to your situation). Switch to “OFF”, then back to “AUTO/REMOTE” or “CHARGE ONLY” as desired. If unit fails to reset, remove more load or allow unit to cool further and retry. Use an optional remote control module (Tripp Lite model APSRM4, sold separately) to reset unit due to overload and overtemperature.
DC OFF (select models): De-energizes unit and connects AC
OUT
to AC IN.
Indicator Lights
Your Inverter/Charger (as well as an optional Tripp Lite Remote Control Module, sold separately) is equipped with a simple, intuitive, user-friendly set of indicator lights. These easily­remembered “traffic light” signals will allow you, shortly after first use, to tell at a glance a wide variety of operating details.
“LINE Green LED”: If the operating mode switch is set to “AUTO/REMOTE”, this light will ILLUMINATE CONTINUOUSLY when your connected equipment is receiving continuous AC power supplied from a utility/generator source.
If the operating mode switch is set to “CHARGE ONLY”, this light will BLINK to alert you that the unit’s inverter is OFF and will NOT supply AC power in the absence of a utility/generator source or in over/under voltage situations.
“INV” (Inverting) Yellow LED: This light will ILLUMINATE CONTINUOUSLY whenever connected equipment is receiving battery-supplied, inverted AC power (in the absence of a utility/generator source or in over/under voltage situations). This light will be off when AC power is supplying the load. This light will BLINK to alert you if the load is less than the Battery Charge Conserver (Load Sense) setting.
“LOAD” Red LED: This red light will ILLUMINATE CONTINUOUSLY whenever the inverter is functioning and the power demanded by connected appliances and equipment exceeds 100% of load capacity. The light will BLINK to alert you when the inverter shuts down due to a severe overload or overheating. If this happens, turn the operating mode switch “OFF”; remove the overload and let the unit cool. You may then turn the operating mode switch to either “AUTO/REMOTE” or “CHARGE ONLY” after it has adequately cooled. This light will be off when AC power is supplying the load.
“BATT VOLTAGE” LEDs: If the operating mode switch is in the "AUTO/REMOTE" or "Charge Only" position, the LEDs indicate the approximate charge level and voltage of your connected battery bank and alert you to several fault conditions. See Chart for charge and voltage levels.
LED Function with Switch in “AUT
O/REMOTE” or
“CHARGE ONLY” Position
Approximate Battery Charge Level*
LEDs Battery Capacity Illuminated (Charging/Discharging)
Green 91%–Full Green & Yellow 81%–90% Yellow 61%–80% Yellow & Red 41%–60% Red 21%–40% All three lights off 1%–20% Flashing red 0% (Inverter
shutdown)**
* Charge levels listed are approximate. Actual conditions vary depending on battery condition and load. ** Inverter shutdown protects battery against damage due to excessive discharge.
Fault Condition
LEDs Fault Illuminated Condition
All three lights Excessive discharge flash slowly* (Inverter shutdown)
All three lights Overcharge (Charger flash quickly** shutdown)
*Approximately ½ second on, ½ second off. See Troubleshooting section. Inverter shutdown protects battery against damage due to excessive discharge.** Approximately ¼ second on, ¼ second off. Charger shutdown protects battery against damage due to overcharge. May also indicate a battery charger fault exists. See Troubleshooting section.